HBHeinz R. Bruppacher

Heinz R. Bruppacher

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Heinz R. Bruppacher has a total of 96 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Top Cited Papers
    Open Access

    Prospective validation of classification of intraoperative adverse events (ClassIntra): international, multicentre cohort study

    by Salome Dell-Kuster, Nuno V Gomes, Larsa Gawria, Soheila Aghlmandi, Maame Aduse-Poku, Ian Bissett, Catherine Blanc, Christian Brandt, Richard B Ten Broek, Heinz R Bruppacher, et al.

    Objective To prospectively assess the construct and criterion validity of ClassIntra version 1.0, a newly developed classification for assessing intraoperative adverse events. Design International, multicentre cohort study. Setting 18 secondary and tertiary centres from 12 countries in Europe, Oceania, and North America. Participants The cohort study included a representative sample of 2520 patients in hospital having any type of surgery, followed up until discharge. A follow-up to assess mortality at 30 days was performed in 2372 patients (94%). A survey was sent to a representative sample of 163 surgeons and anaesthetists from participating centres. Main outcome measures Intraoperative complications were assessed according to ClassIntra. Postoperative complications were assessed daily until discharge from hospital with the Clavien-Dindo classification. The primary endpoint was construct validity by investigating the risk adjusted association between the most severe intraoperative and postoperative complications, measured in a multivariable hierarchical proportional odds model. For criterion validity, inter-rater reliability was evaluated in a survey of 10 fictitious case scenarios describing intraoperative complications. Results Of 2520 patients enrolled, 610 (24%) experienced at least one intraoperative adverse event and 838 (33%) at least one postoperative complication. Multivariable analysis showed a gradual increase in risk for a more severe postoperative complication with increasing grade of ClassIntra: ClassIntra grade I versus grade 0, odds ratio 0.99 (95% confidence interval 0.69 to 1.42); grade II versus grade 0, 1.39 (0.97 to 2.00); grade III versus grade 0, 2.62 (1.31 to 5.26); and grade IV versus grade 0, 3.81 (1.19 to 12.2). ClassIntra showed high criterion validity with an intraclass correlation coefficient of 0.76 (95% confidence interval 0.59 to 0.91) in the survey (response rate 83%). Conclusions ClassIntra is the first prospectively validated classification for assessing intraoperative adverse events in a standardised way, linking them to postoperative complications with the well established Clavien-Dindo classification. ClassIntra can be incorporated into routine practice in perioperative surgical safety checklists, or used as a monitoring and outcome reporting tool for different surgical disciplines. Future studies should investigate whether the tool is useful to stratify patients to the appropriate postoperative care, to enhance the quality of surgical interventions, and to improve long term outcomes of surgical patients. Trial registration ClinicalTrials.gov NCT03009929.


  • Oropharyngeal leak pressure of the LMA Protector™ vs the LMA Supreme™; a prospective, randomized, controlled clinical trial

    by Berthold Moser, Christian Keller, Laurent Audigé, Heinz R. Bruppacher

    Background: Clinical characteristics such as oropharyngeal leak pressure (OLP) and ventilation peak pressure are important factors for successful use of supraglottic airway devices in general anaesthesia. We hypothesized that the LMA Protector™ compared to the LMA Supreme™ may develop a higher OLP, which could be of clinical significance.Methods: Ninety‐six patients were randomized to the LMA Protector™ or LMA Supreme™ groups. We measured oropharyngeal leak pressure within 5 minutes after insertion of the supraglottic airway device with a standardized cuff pressure at 60 cm H2O. Secondary parameters, such as insertion time of the supraglottic airway device, the number of attempts inserting the supraglottic airway device and the gastric tube, volume of gastric contents, and maximum airway pressure, as well as pulse oximetry throughout the operation were measured. Further, blood staining after removal of the supraglottic airway device and postoperative airway morbidity 3 hours after surgery were determined.Results: The mean difference of oropharyngeal leak pressure was 5.2 (95% CI 2.8‐7.6), ie, 30.9 (7.4) cmH2O for the LMA Protector™ vs 25.6 (4.4) cmH2O for the LMA Supreme™ (P < 0.001; mean(SD)). Similarly, there was a mean difference between OLP and maximal ventilation peak pressure 5.6 (95% CI 3.1‐8.2) ie 19.6 (7.7) cmH2O for the LMA Protector™ vs 14.0 (4.4) cmH2O for the LMA Supreme™ (P < 0.001). No difference was found between the groups for other secondary parameters, as well as postoperative airway morbidity.Conclusion: The LMA Protector™ enabled a higher OLP compared to the LMA Supreme™. This finding may be important for patients requiring a higher peak pressure for sufficient supraglottic airway device ventilation.


  • Fiberoptic intubation of severely obese patients through supraglottic airway: A prospective, randomized trial of the Ambu® AuraGain™ laryngeal mask vs the i‐gel™ airway

    by Berthold Moser, Christian Keller, Laurent Audigé, Mital H. Dave, Heinz R. Bruppacher

    Introduction: Airway management in severely obese patients remains a challenging issue for anaesthetists and may lead to life‐threatening situations. Supraglottic airway devices, such as the i‐gel™ or the AuraGain™, were developed, with the possibility to ventilate the patient or use them as a conduit for endotracheal intubation.Methods: In our randomized prospective trial, we hypothesized a 10 seconds faster fiberoptic trans‐device intubation time through the AuraGain™ laryngeal mask compared to the i‐gel™ laryngeal mask in severely obese patients. We randomly assigned 44 patients to the AuraGain or i‐gel group and measured trans‐device intubation time after 5 minutes of successful ventilation through the device. Secondary parameters relating to the trans‐device intubation success, oropharyngeal leak pressure, and parameters regarding insertion of the supraglottic airway devices were measured. Postoperative airway morbidity was determined 5 hours after surgery.Results: Mean (SD) intubation time was 55.7 (5.8) seconds for the AuraGain™ vs 54.1 (8.5) for i‐gel™ mask (95% CI −2.7 to 5.9; P = 0.474), respectively, on a mean body mass index (BMI) of 39.4 kg/m2 in the AuraGain™ group vs 38.9 kg/m2 in i‐gel™ group. No difference could be found in the other studied parameters.Conclusions: Time for intubation through both supraglottic airway devices was similar. Attributed to fast possibility of securing the airway with both supraglottic airway devices, we believe that both, AuraGain™ and i‐gel™, can be a good alternative in the airway management in obese patients.


  • A prospective, randomized trial of the Ambu AuraGain™ laryngeal mask versus the LMA® protector airway in paralyzed, anesthetized adult men

    by Berthold Moser, Laurent Audigé, Christian Keller, Joseph Brimacombe, Lukas Gasteiger, Heinz R. Bruppacher

    Article: A prospective, randomized trial of the Ambu AuraGain™ laryngeal mask versus the LMA® protector airway in paralyzed, anesthetized adult men - Minerva Anestesiologica 2018 June;84(6):684-92 - Minerva Medica - Journals


  • Flexible bronchoscopic intubation through the AuraGain™ laryngeal mask versus a slit Guedel tube: a non-inferiority randomized-controlled trial

    by Berthold Moser, Laurent Audigé, Christian Keller, Joseph Brimacombe, Lukas Gasteiger, Heinz R. Bruppacher

    AuraGainTM, a novel third-generation laryngeal mask, can facilitate insertion of a gastric tube and provide the potential advantage of intubation. Data are lacking on intubation through the AuraGain laryngeal mask.


  • Open Access

    Transfer of skills and comparison of performance between king vision® video laryngoscope and macintosh blade following an AHA airway management course

    by Lukas E. Wolf, José A. Aguirre, Christian Vogt, Christian Keller, Alain Borgeat, Heinz R. Bruppacher

    To potentially optimize intubation skill teaching in an American Heart Association® Airway Management Course® for novices, we investigated the transfer of skills from video laryngoscopy to direct laryngoscopy and vice versa using King Vision® and Macintosh blade laryngoscopes respectively. Ninety volunteers (medical students, residents and staff physicians) without prior intubation experience were randomized into three groups to receive intubation training with either King Vision® or Macintosh blade or both. Afterwards they attempted intubation on two human cadavers with both tools. The primary outcome was skill transfer from video laryngoscopy to direct laryngoscopy assessed by first attempt success rates within 60 s. Secondary outcomes were skill transfer in the opposite direction, the efficacy of teaching both tools, and the success rates and esophageal intubation rates of Macintosh blade versus King Vision®. Performance with the Macintosh blade was identical following training with either Macintosh blade or King Vision® (unadjusted odds ratio [OR] 1.09, 95% confidence interval [95% CI] 0.5–2.6). Performance with the King Vision® was significantly better in the group that was trained on it (OR 2.7, 95% CI 1.2–5.9). Success rate within 60 s with Macintosh blade was 48% compared to 52% with King Vision® (OR 0.85, 95% CI 0.4–2.0). Rate of esophageal intubations with Macintosh blade was significantly higher (17% versus 4%, OR 5.0, 95% CI 1.1–23). We found better skill transfer from King Vision® to Macintosh blade than vice versa and fewer esophageal intubations with video laryngoscopy. For global skill improvement in an airway management course for novices, teaching only video laryngoscopy may be sufficient. However, success rates were low for both devices.


  • Looking in the mirror: Self-debriefing versus instructor debriefing for simulated crises*

    by Sylvain Boet, M. Dylan Bould, Heinz R. Bruppacher, François Desjardins, Deven B. Chandra, Viren N. Naik

    To examine the effectiveness of self-debriefing as compared to instructor debriefing in the change of nontechnical skills performance of anesthesiology residents. Prospective, randomized, controlled study. A university hospital simulation center. : Fifty anesthesiology residents. Subjects were instructed in the principles of nontechnical skills for crisis management. Subsequently, each resident participated in a high-fidelity simulated anesthesia crisis scenario (pretest). Participants were randomized to either a video-assisted self-debriefing or instructor debriefing. In the self-debriefing group, subjects reviewed their pretest scenario by themselves, guided by the Anesthetists' Non-Technical Skills scale. The instructor debriefing group reviewed their pretest scenario guided by an expert instructor also using the Anesthetists' Non-Technical Skills scale as a framework. Immediately following their respective debriefings, subjects managed a second simulated crisis (post-test). After all data were collected, two blinded experts independently rated videos of all performances in a random order using the Anesthetists' Non-Technical Skills scale. Performance significantly improved from pretest to post-test (p < .01) regardless of the type of debriefing received. There was no significant difference in the degree of improvement between self-debriefing and instructor debriefing (p = .58). Nontechnical skills for crisis resource management improved with training, as measured by the Anesthetists' Non-Technical Skills scale. Crisis resource management can be taught, with measurable improvements. Effective teaching of nontechnical skills can be achieved through formative self-assessment even when instructors are not available.


  • First, do no harm: using simulated patient death to enhance learning?

    by Heinz R. Bruppacher, Ruth P. Chen, Kevin Lachapelle