    Experimental Validation of Large Eddy Simulation as a Benchmark for Reynolds-Averaged Navier-Stokes Flow Modeling in a Magnetically Levitated Blood Pump

    by Jonas Abeken, Utku Gülan, Kai von Petersdorff-Campen, Vasileios Charitatos, Marianne Schmid Daners, Mirko Meboldt, Markus Holzner, Diane de Zélicourt, Vartan Kurtcuoglu

    Purpose: This study investigates the potential of large eddy simulation (LES) as a benchmark for validating Reynolds-averaged Navier-Stokes (RANS) models in the CentriMag centrifugal blood pump. We compare velocity field predictions from LES and RANS against particle image velocimetry (PIV) and quantify previously unreported non-rotatory components in the motion of the magnetically levitated impeller, assessing their impact on flow dynamics. Methods: We performed PIV on an optically accessible pump replica and compared phase-averaged velocity fields with computational fluid dynamics (CFD) predictions from LES and three unsteady RANS models. In addition, using custom optical trackers embedded in the PIV setup, we quantified the three-dimensional impeller motion and replicated its main non-rotatory components in the simulations. Results: The impeller exhibited complex but small deviations from ideal rotation. When incorporated into the CFD model, these had negligible impact on the flow field. LES predictions agreed well with PIV data, with root-mean-square velocity errors of approximately 3%, while the RANS models showed larger local deviations, particularly in the outlet region. Conclusion: LES demonstrated close agreement with PIV and proved to be a reliable reference for validating RANS models in this study. Although the analysis was limited to a single pump, LES warrants further consideration as a potential benchmark method that could reduce reliance on extensive experimental flow validation. Consistent with previous findings, the transition from the volute to the outlet emerged as a particularly sensitive region for RANS modeling and validation. The quantified non-rotatory impeller motion had negligible impact on the flow field, supporting the continued use of idealized rotor motion in CFD modeling of similar magnetically levitated devices.


  • Incorporating Unresolved Stresses in Blood Damage Modeling: Energy Dissipation More Accurate Than Reynolds Stress Formulation

    by Jonas Abeken, Diane de Zélicourt, Vartan Kurtcuoglu

    Objective: Reynolds Averaged Navier Stokes (RANS) models are often used as the basis for modeling blood damage in turbulent flows. To predict blood damage by turbulence stresses that are not resolved in RANS, a stress formulation that represents the corresponding scales is required. Here, we compare two commonly employed stress formulations: a scalar stress representation that uses Reynolds stresses as a surrogate for unresolved fluid stresses, and an effective stress formulation based on energy dissipation. Methods: We conducted unsteady RANS simulations of the CentriMag blood pump with three different closure models and a Large Eddy Simulation (LES) for reference. We implemented both stress representations in all models and compared the resulting total stress distributions in Eulerian and Lagrangian frameworks. Results: The Reynolds-stress-based approach overestimated the contribution of unresolved stresses in RANS, with differences between closure models of up to several orders of magnitude. With the dissipation-based approach, the total stresses predicted with RANS deviated by about 50% from the LES reference, which was more accurate than only considering resolved stresses. Conclusion: The Reynolds-stress-based formulation proved unreliable for estimating scalar stresses in our RANS simulations, while the dissipation-based approach provided an accuracy improvement over simply neglecting unresolved stresses. Significance: Our results suggest that dissipation-based inclusion of unresolved stresses should be the preferred choice for blood damage modeling in RANS.


  • Open Access

    Insights Into the Low Rate of In-Pump Thrombosis With the HeartMate 3: Does the Artificial Pulse Improve Washout?

    by Peng Fang, Jianjun Du, Andrea Boraschi, Silvia Bozzi, Alberto Redaelli, Marianne Schmid Daners, Vartan Kurtcuoglu, Filippo Consolo, Diane de Zélicourt

    While earlier studies reported no relevant effect of the HeartMate 3 (HM3) artificial pulse (AP) on bulk pump washout, its effect on regions with prolonged residence times remains unexplored. Using numerical simulations, we compared pump washout in the HM3 with and without AP with a focus on the clearance of the last 5% of the pump volume. Results were examined in terms of flush-volume (Vf, number of times the pump was flushed with new blood) to probe the effect of the AP independent of changing flow rate. Irrespective of the flow condition, the HM3 washout scaled linearly with flush volume up to 70% washout and slowed down for the last 30%. Flush volumes needed to washout 95% of the pump were comparable with and without the AP (1.3–1.4 Vf), while 99% washout required 2.1–2.2 Vf with the AP vs. 2.5 Vf without the AP. The AP enhanced washout of the bend relief and near-wall regions. It also transiently shifted or eliminated stagnation regions and led to rapid wall shear stress fluctuations below the rotor and in the secondary flow path. Our results suggest potential benefits of the AP for clearance of fluid regions that might elicit in-pump thrombosis and provide possible mechanistic rationale behind clinical data showing very low rate of in-pump thrombosis with the HM3. Further optimization of the AP sequence is warranted to balance washout efficacy while limiting blood damage.


  • Thrombotic Risk of Rotor Speed Modulation Regimes of Contemporary Centrifugal Continuous-flow Left Ventricular Assist Devices

    by Andrea Boraschi, Silvia Bozzi, Bente Thamsen, Marcus Granegger, Lena Wiegmann, Federico Pappalardo, Marvin J. Slepian, Vartan Kurtcuoglu, Alberto Redaelli, Diane De Zélicourt, et al.

    Contemporary centrifugal continuous-flow left ventricular assist devices (LVADs) incorporate dynamic speed modulation algorithms. Hemocompatibility of these periodic unsteady pump operating conditions has been only partially explored. We evaluated whether speed modulation induces flow alterations associated with detrimental prothrombotic effects. For this aim, we evaluated the thrombogenic profile of the HeartWare ventricular assist device (HVAD) Lavare Cycle (LC) and HeartMate3 (HM3) artificial pulse (AP) via comprehensive numerical evaluation of (i) pump washout, (ii) stagnation zones, (iii) shear stress regimens, and (iv) modeling of platelet activation status via the platelet activity state (PAS) model. Data were compared between different simulated operating scenarios, including: (i) constant rotational speed and pump pressure head, used as reference; (ii) unsteady pump pressure head as induced by cardiac pulsatility; and (iii) unsteady rotor speed modulation of the LC (HVAD) and AP (HM3). Our results show that pump washout did not improve across the different simulated scenarios in neither the HVAD nor the HM3. The LC reduced but did not eliminate flow stagnation (–57%) and did not impact metrics of HVAD platelet activation (median PAS: +0.4%). The AP reduced HM3 flow stagnation by up to 91% but increased prothrombotic shear stress and simulated platelet activation (median PAS: +124%). Our study advances understanding of the pathogenesis of LVAD thrombosis, suggesting mechanistic implications of rotor speed modulation. Our data provide rationale criteria for the future design optimization of next generation LVADs to further reduce hemocompatibility-related adverse events.


  • In Vitro Testing and Comparison of Additively Manufactured Polymer Impellers for the CentriMag Blood Pump

    by Kai von Petersdorff-Campen, Jonas Abeken, Diane de Zélicourt, Vartan Kurtcuoglu, Mirko Meboldt, Marianne Schmid Daners

    Additive manufacturing (AM) is an effective tool for accelerating knowledge gain in development processes, as it enables the production of complex prototypes at low cost and with short lead times. In the development of mechanical circulatory support, the use of cheap polymer-based AM techniques for prototype manufacturing allows more design variations to be tested, promoting a better understanding of the respective system and its optimization parameters. Here, we compare four commonly used AM processes for polymers with respect to manufacturing accuracy, surface roughness, and shape fidelity in an aqueous environment. Impeller replicas of the CentriMag blood pump were manufactured with each process and integrated into original pump housings. The assemblies were tested for hydraulic properties and hemolysis in reference to the commercially available pump. Computational fluid dynamic simulations were carried out to support the transfer of the results to other applications. In hydraulic testing, the deviation in pressure head and motor current of all additively manufactured replicas from the reference pump remained below 2% over the entire operating range of the pump. In contrast, significant deviations of up to 620% were observed in hemolysis testing. Only the replicas produced by stereolithography showed a nonsignificant deviation from the reference pump, which we attribute to the low surface roughness of parts manufactured thereby. The results suggest that there is a flow-dependent threshold of roughness above which a surface strongly contributes to cell lysis by promoting a hydraulically rough boundary flow.


  • Open Access

    Hypoxia sensing by hepatic stellate cells leads to VEGF-dependent angiogenesis and may contribute to accelerated liver regeneration

    by Konstantin Dirscherl, Martin Schläpfer, Birgit Roth Z’graggen, Roland H Wenger, Christa Booy, Renata Flury-Frei, Rita Fatzer, Costica Aloman, Birke Bartosch, Romain Parent, et al.

    Portal vein ligation (PVL) induces liver growth prior to resection. Associating liver partition and portal vein ligation (PVL plus transection=ALPPS) or the addition of the prolyl-hydroxylase inhibitor dimethyloxalylglycine (DMOG) to PVL both accelerate growth via stabilization of HIF-α subunits. This study aims at clarifying the crosstalk of hepatocytes (HC), hepatic stellate cells (HSC) and liver sinusoidal endothelial cells (LSEC) in accelerated liver growth. In vivo, liver volume, HC proliferation, vascular density and HSC activation were assessed in PVL, ALPPS, PVL+DMOG and DMOG alone. Proliferation of HC, HSC and LSEC was determined under DMOG in vitro. Conditioned media experiments of DMOG-exposed cells were performed. ALPPS and PVL+DMOG accelerated liver growth and HC proliferation in comparison to PVL. DMOG alone did not induce HC proliferation, but led to increased vascular density, which was also observed in ALPPS and PVL+DMOG. Activated HSC were detected in ALPPS, PVL+DMOG and DMOG, again not in PVL. In vitro, DMOG had no proliferative effect on HC, but conditioned supernatant of DMOG-treated HSC induced VEGF-dependent proliferation of LSEC. Transcriptome analysis confirmed activation of proangiogenic factors in hypoxic HSC. Hypoxia signaling in HSC induces VEGF-dependent angiogenesis. HSC play a crucial role in the cellular crosstalk of rapid liver regeneration.


  • Open Access

    Rapid Cellular Perception of Gravitational Forces in Human Jurkat T Cells and Transduction into Gene Expression Regulation

    by Cora Sandra Thiel, Swantje Christoffel, Svantje Tauber, Christian Vahlensieck, Diane de Zélicourt, Liliana E. Layer, Beatrice Lauber, Jennifer Polzer, Oliver Ullrich

    Cellular processes are influenced in many ways by changes in gravitational force. In previous studies, we were able to demonstrate, in various cellular systems and research platforms that reactions and adaptation processes occur very rapidly after the onset of altered gravity. In this study we systematically compared differentially expressed gene transcript clusters (TCs) in human Jurkat T cells in microgravity provided by a suborbital ballistic rocket with vector-averaged gravity (vag) provided by a 2D clinostat. Additionally, we included 9× g centrifuge experiments and rigorous controls for excluding other factors of influence than gravity. We found that 11 TCs were significantly altered in 5 min of flight-induced and vector-averaged gravity. Among the annotated clusters were G3BP1, KPNB1, NUDT3, SFT2D2, and POMK. Our results revealed that less than 1% of all examined TCs show the same response in vag and flight-induced microgravity, while 38% of differentially regulated TCs identified during the hypergravity phase of the suborbital ballistic rocket flight could be verified with a 9× g ground centrifuge. In the 2D clinostat system, doing one full rotation per second, vector effects of the gravitational force are only nullified if the sensing mechanism requires 1 s or longer. Due to the fact that vag with an integration period of 1 s was not able to reproduce the results obtained in flight-induced microgravity, we conclude that the initial trigger of gene expression response to microgravity requires less than 1 s reaction time. Additionally, we discovered extensive gene expression differences caused by simple handling of the cell suspension in control experiments, which underlines the need for rigorous standardization regarding mechanical forces during cell culture experiments in general.


  • Fluid Dynamics in the HeartMate 3: Influence of the Artificial Pulse Feature and Residual Cardiac Pulsation

    by Lena Wiegmann, Bente Thamsen, Diane de Zélicourt, Marcus Granegger, Stefan Boës, Marianne Schmid Daners, Mirko Meboldt, Vartan Kurtcuoglu

    Ventricular assist devices (VADs), among which the HeartMate 3 (HM3) is the latest clinically approved representative, are often the therapy of choice for patients with end‐stage heart failure. Despite advances in the prevention of pump thrombosis, rates of stroke and bleeding remain high. These complications are attributed to the flow field within the VAD, among other factors. One of the HM3’s characteristic features is an artificial pulse that changes the rotor speed periodically by 4000 rpm, which is meant to reduce zones of recirculation and stasis. In this study, we investigated the effect of this speed modulation on the flow fields and stresses using high‐resolution computational fluid dynamics. To this end, we compared Eulerian and Lagrangian features of the flow fields during constant pump operation, during operation with the artificial pulse feature, and with the effect of the residual native cardiac cycle. We observed good washout in all investigated situations, which may explain the low incidence rates of pump thrombosis. The artificial pulse had no additional benefit on scalar washout performance, but it induced rapid variations in the flow velocity and its gradients. This may be relevant for the removal of deposits in the pump. Overall, we found that viscous stresses in the HM3 were lower than in other current VADs. However, the artificial pulse substantially increased turbulence, and thereby also total stresses, which may contribute to clinically observed issues related to hemocompatibility.


  • Virtual surgical planning, flow simulation, and 3-dimensional electrospinning of patient-specific grafts to optimize Fontan hemodynamics

    by Dominik Siallagan, Yue-Hin Loke, Laura Olivieri, Justin Opfermann, Chin Siang Ong, Diane de Zélicourt, Anastasios Petrou, Marianne Schmid Daners, Vartan Kurtcuoglu, Mirko Meboldt, et al.