Manuel Rijo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Manuel Rijo has a total of 32 co-authors. Here are the top co-authors by number of shared publications:
- Luís Rato
VISTA Lab, ALGORITMI Research Center/LASI, University of Évora, 7000-671 Evora, Portugal
7 shared publications - Joao Miranda Lemos
INESC-ID, Instituto Superior Tcnico, Universidade de Lisboa, Lisbon, Portugal
5 shared publications Carina Arranja
Hydraulic Professor, Hydraulics and Canal Control Center, Departamento Engenharia Rural, Universidade de Évora, Apartado 94, 7002-554 Évora, Portugal
3 shared publications- Miguel Ayala Botto
IDMEC, Instituto Superior Técnico, Universidade de Lisboa, Av. Rovisco Pais 1, 1049-001 Lisboa, Portugal
3 shared publications - João Figueiredo
Department of Mechatronics, IDMEC, University of Évora, 7000-645 Évora, Portugal
2 shared publications - António Betâmio de Almeida
Instituto Superior Técnico da Universidade de Lisboa
1 shared publication
Latest Publications
- 1 June 2017
- Published by American Society of Civil Engineers (ASCE) in Journal of Irrigation and Drainage Engineering
- Vol. 143 (6)
Flow Rate Measurements under Sluice Gates
Sluice gates are commonly used in canals for control and measurement of the flow. The discharge under sluice gates can be determined through the energy-momentum method (EM), the orifice flow rate equations and the application of the -theorem of the dimensional analysis. The different discharge methods available, for free and submerged hydraulic jump including the transition between flows, were compared with experimental data. The performance of the different calibration methods was analyzed. The test program was conducted in the laboratory flume and in the experimental irrigation canal of the University of Évora, Portugal. The test program shows that the evaluation of the discharge under sluice gates for free and submerged flows and for the transition between both flows through the methods based in the EM were those who had better results. For the studied gates openings, the results also show that the methods that consider the division of the submerged flow in partial and totally submerged did not improve the discharge results.- 1 June 2017
- Published by American Society of Civil Engineers (ASCE) in Journal of Irrigation and Drainage Engineering
- Vol. 143 (6)
Flow Rate Measurements under Sluice Gates
Sluice gates are commonly used in canals for control and measurement of the flow. The discharge under sluice gates can be determined through the energy-momentum method (EM), the orifice flow rate equations and the application of the -theorem of the dimensional analysis. The different discharge methods available, for free and submerged hydraulic jump including the transition between flows, were compared with experimental data. The performance of the different calibration methods was analyzed. The test program was conducted in the laboratory flume and in the experimental irrigation canal of the University of Évora, Portugal. The test program shows that the evaluation of the discharge under sluice gates for free and submerged flows and for the transition between both flows through the methods based in the EM were those who had better results. For the studied gates openings, the results also show that the methods that consider the division of the submerged flow in partial and totally submerged did not improve the discharge results.- 1 March 2016
- Published by Associacao Portuguesa dos Recursos Hidricos (APRH) in Revista Recursos Hídricos
- Vol. 37 (1) , 59-72
Supervisão e controlo de um sistema de canais de rega. Parte I – Definição e apresentação geral
- 1 March 2016
- Published by Associacao Portuguesa dos Recursos Hidricos (APRH) in Revista Recursos Hídricos
- Vol. 37 (1) , 59-72
Supervisão e controlo de um sistema de canais de rega. Parte I – Definição e apresentação geral
- 1 October 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 21621195,p. 432-437
Actuator fault tolerant LQG control of a water delivery canal
The problem of reconfiguration of the control system to mitigate the effects of actuator faults in a water delivery canal is addressed in this paper. When a fault in an actuator is detected and isolated, the controller is reconfigured by changing the set of manipulated and process variables and using a different controller, associated to a different plant model, in a hybrid systems framework. In order to prevent instability that may be associated with switching among controllers, a dwell time condition is used. Both centralized and distributed LQG controllers are considered. In the case of distributed control, a game approach is followed to coordinate the different local controllers. Experimental results are presented.
- 1 October 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 21621195,p. 432-437
Actuator fault tolerant LQG control of a water delivery canal
The problem of reconfiguration of the control system to mitigate the effects of actuator faults in a water delivery canal is addressed in this paper. When a fault in an actuator is detected and isolated, the controller is reconfigured by changing the set of manipulated and process variables and using a different controller, associated to a different plant model, in a hybrid systems framework. In order to prevent instability that may be associated with switching among controllers, a dwell time condition is used. Both centralized and distributed LQG controllers are considered. In the case of distributed control, a game approach is followed to coordinate the different local controllers. Experimental results are presented.
- 1 October 2013
- Published by American Society of Civil Engineers (ASCE) in Journal of Irrigation and Drainage Engineering
- Vol. 139 (10) , 855-863
Multivariable and Distributed LQG Control of a Water Delivery Canal
This paper addresses the problem of the development of a distributed linear quadratic Gaussian (LQG) controller for a water delivery canal. The control structure proposed relies on a set of LQG control agents interconnected through a communication network. Each of these local control agents controls a canal reach made of a pool and the corresponding downstream gate and receives information (output signal and control moves) only from the corresponding canal reach and the ones that are adjacent to it. An algorithm is proposed to achieve coordinated action of the different local control agents. This distributed control structure is compared with centralized multivariable LQG control. Several aspects with incidence on performance are addressed, including the modification of the quadratic cost to ensure a constraint on closed-loop poles, the use of a nonlinear filter to limit noise effects, and the impact of a quantization commonly forced in gate position. Experimental results obtained in a pilot canal are presented.
- 1 October 2013
- Published by American Society of Civil Engineers (ASCE) in Journal of Irrigation and Drainage Engineering
- Vol. 139 (10) , 855-863
Multivariable and Distributed LQG Control of a Water Delivery Canal
This paper addresses the problem of the development of a distributed linear quadratic Gaussian (LQG) controller for a water delivery canal. The control structure proposed relies on a set of LQG control agents interconnected through a communication network. Each of these local control agents controls a canal reach made of a pool and the corresponding downstream gate and receives information (output signal and control moves) only from the corresponding canal reach and the ones that are adjacent to it. An algorithm is proposed to achieve coordinated action of the different local control agents. This distributed control structure is compared with centralized multivariable LQG control. Several aspects with incidence on performance are addressed, including the modification of the quadratic cost to ensure a constraint on closed-loop poles, the use of a nonlinear filter to limit noise effects, and the impact of a quantization commonly forced in gate position. Experimental results obtained in a pilot canal are presented.
- 1 June 2013
- Published by Elsevier in Control Engineering Practice
- Vol. 21 (6) , 870-886
SCADA system with predictive controller applied to irrigation canals
- 1 June 2013
- Published by Elsevier in Control Engineering Practice
- Vol. 21 (6) , 870-886
SCADA system with predictive controller applied to irrigation canals
- 1 July 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 722-727
Distributed LQG control of a water delivery canal with feedforward from measured consumptions
This work addresses the design of distributed LQG controllers for water delivery canals that include feedforward from local farmer water consumptions. The proposed architecture consists of a network of local control agents, each connected to one of the canal pools and sharing information with their neighbors in order to act in a coordinated way. In order to improve performance, the measurement of the outflow from each pool is used as a feedforward signal. Although the feedforward action is local, it propagates due to the coordination procedure. The paper presents the distributed LQG algorithm with feedforward and experimental results in a large scale pilot water delivery canal.
- 1 July 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 722-727
Distributed LQG control of a water delivery canal with feedforward from measured consumptions
This work addresses the design of distributed LQG controllers for water delivery canals that include feedforward from local farmer water consumptions. The proposed architecture consists of a network of local control agents, each connected to one of the canal pools and sharing information with their neighbors in order to act in a coordinated way. In order to improve performance, the measurement of the outflow from each pool is used as a feedforward signal. Although the feedforward action is local, it propagates due to the coordination procedure. The paper presents the distributed LQG algorithm with feedforward and experimental results in a large scale pilot water delivery canal.
- 1 June 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 21 (07431619) , 3346-3351
Control of a water delivery canal with cooperative distributed MPC
This article addresses the problem of controlling pool levels in a water delivery canal using a novel cooperative distributed MPC control algorithm that incorporates stability constraints. According to a distributed control strategy, a local control agent is associated to all canal gates (actuators). In order to achieve cooperative action, each control agent computes the corresponding gate position (manipulated variable) by performing the minimization of a cost function that considers not only its local control objectives, but also the ones of their immediate neighbors. For this purpose, a MPC algorithm with stability constraints is used (SIORHC). At the beginning of each sampling interval, local control agents exchange information with their neighbors and adjust their decisions in an iterative way. The resulting distributed MPC is denoted D-SIORHC and yields a stable closed-loop. Experimental results are provided to show the influence of the controller configuration parameters on the resulting performance.
- 1 June 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 21 (07431619) , 3346-3351
Control of a water delivery canal with cooperative distributed MPC
This article addresses the problem of controlling pool levels in a water delivery canal using a novel cooperative distributed MPC control algorithm that incorporates stability constraints. According to a distributed control strategy, a local control agent is associated to all canal gates (actuators). In order to achieve cooperative action, each control agent computes the corresponding gate position (manipulated variable) by performing the minimization of a cost function that considers not only its local control objectives, but also the ones of their immediate neighbors. For this purpose, a MPC algorithm with stability constraints is used (SIORHC). At the beginning of each sampling interval, local control agents exchange information with their neighbors and adjust their decisions in an iterative way. The resulting distributed MPC is denoted D-SIORHC and yields a stable closed-loop. Experimental results are provided to show the influence of the controller configuration parameters on the resulting performance.
- 1 January 2011
- Published by Elsevier in IFAC Proceedings Volumes
- Vol. 44 (1) , 7885-7890
Multi-Platform Controller Interface for SCADA Application
- 1 January 2011
- Published by Elsevier in IFAC Proceedings Volumes
- Vol. 44 (1) , 7885-7890
Multi-Platform Controller Interface for SCADA Application
- 1 January 2011
- Published by INSTICC
- p. 142-147
FLEXIBLE FRAMEWORK FOR MODELING WATER CONVEYANCE NETWORKS
The SCITEPRESS Digital Library offers online access to all papers presented at INSTICC conferences, as well as a few conferences organized by others.
- 1 January 2011
- Published by INSTICC
- p. 142-147
FLEXIBLE FRAMEWORK FOR MODELING WATER CONVEYANCE NETWORKS
The SCITEPRESS Digital Library offers online access to all papers presented at INSTICC conferences, as well as a few conferences organized by others.
- 1 January 2010
- Published by American Society of Civil Engineers (ASCE) in Journal of Irrigation and Drainage Engineering
- Vol. 136 (1) , 3-10
Supervision and Water Depth Automatic Control of an Irrigation Canal
A supervisory and control system developed for a Portuguese irrigation canal system equipped with motorized sluice gates and buffer reservoirs is presented. The article discusses the development and tuning of the canal system’s controllers: manual controllers for direct control of gate position and gate flow controllers, which maintain discharge at predefined values; automatic controllers for water depth control upstream from check structures. System hydraulics was simulated using an unsteady flow open-channel model based on the complete Saint-Venant equations. After field calibration and validation, the model was used for tuning the water depth controllers. The automatic upstream water depth control is based on local proportional-integral controllers. Controller gains were determined using optimization tools provided by the hydraulic simulator. These procedures tune the controller parameters globally, considering a given set of inflow variations. Finally, the paper presents simulated control tests results and an analysis of controller performances. Under the test conditions, the controller was able to drive water levels back to their setpoint rapidly and without instabilities and also guaranteeing stable gates movement.
- 1 January 2010
- Published by American Society of Civil Engineers (ASCE) in Journal of Irrigation and Drainage Engineering
- Vol. 136 (1) , 3-10
Supervision and Water Depth Automatic Control of an Irrigation Canal
A supervisory and control system developed for a Portuguese irrigation canal system equipped with motorized sluice gates and buffer reservoirs is presented. The article discusses the development and tuning of the canal system’s controllers: manual controllers for direct control of gate position and gate flow controllers, which maintain discharge at predefined values; automatic controllers for water depth control upstream from check structures. System hydraulics was simulated using an unsteady flow open-channel model based on the complete Saint-Venant equations. After field calibration and validation, the model was used for tuning the water depth controllers. The automatic upstream water depth control is based on local proportional-integral controllers. Controller gains were determined using optimization tools provided by the hydraulic simulator. These procedures tune the controller parameters globally, considering a given set of inflow variations. Finally, the paper presents simulated control tests results and an analysis of controller performances. Under the test conditions, the controller was able to drive water levels back to their setpoint rapidly and without instabilities and also guaranteeing stable gates movement.