Akira Sugiura
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Akira Sugiura has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
Keizo Yonemori
Graduate School of Agriculture, Kyoto University, Sakyo-ku, Kyoto 606-8502, Japan
2 shared publicationsSuranant Subhadrabandhu
Graduate School of Agriculture, Kyoto University, Sakyo-ku, Kyoto 606-8502, Japan
2 shared publications- Chitose Honsho
Faculty of Agriculture, University of Miyazaki
1 shared publication Fujio Amemiya
NTT Advanced Technology Corporation, Tokyo, Japan
1 shared publicationFumiaki Nakatsubo
Kyoto University
1 shared publication- Jun Ito
Department of Applied Physics, Graduate School of Engineering, Tohoku University, Sendai, Miyagi 980-8579, Japan
1 shared publication
Latest Publications
- 10 January 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electromagnetic Compatibility
- Vol. 62 (5) , 1830-1839
Differential-/Common-Mode Conversion Loss and LCL/TCL Measurement Methods
In wired signal transmission, conversion between the differential and common modes deteriorates the quality of the transmitted signal and also causes electromagnetic compatibility problems in the environment. Therefore, the transmission-line components are requested to be tested on their conversion loss characteristics, such as the longitudinal conversion loss (LCL), transverse conversion loss (TCL), and mixed-mode S-parameters. Theoretical investigations are carried out to analyze the mode conversion of a differential one-port device in order to express the conversion loss parameters in terms of the modal impedances of the device. Consequently, the mutual relationships among the parameters are derived using the modal impedances. In addition, a new LCL measurement method is proposed that can accurately determine LCL values of a device under test by using a vector network analyzer instead of a traditional balun-transformer measuring instrument. Furthermore, it is found that the ratio of the TCL to LCL is not constant but varies with device characteristics. Therefore, a new definition of the TCL is proposed in place of the conventional one. The validity of these theoretical results is confirmed through SPICE simulation and measurements.
- 10 January 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electromagnetic Compatibility
- Vol. 62 (5) , 1830-1839
Differential-/Common-Mode Conversion Loss and LCL/TCL Measurement Methods
In wired signal transmission, conversion between the differential and common modes deteriorates the quality of the transmitted signal and also causes electromagnetic compatibility problems in the environment. Therefore, the transmission-line components are requested to be tested on their conversion loss characteristics, such as the longitudinal conversion loss (LCL), transverse conversion loss (TCL), and mixed-mode S-parameters. Theoretical investigations are carried out to analyze the mode conversion of a differential one-port device in order to express the conversion loss parameters in terms of the modal impedances of the device. Consequently, the mutual relationships among the parameters are derived using the modal impedances. In addition, a new LCL measurement method is proposed that can accurately determine LCL values of a device under test by using a vector network analyzer instead of a traditional balun-transformer measuring instrument. Furthermore, it is found that the ratio of the TCL to LCL is not constant but varies with device characteristics. Therefore, a new definition of the TCL is proposed in place of the conventional one. The validity of these theoretical results is confirmed through SPICE simulation and measurements.
- 26 May 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electromagnetic Compatibility
- Vol. 58 (5) , 1526-1534
Technical Problems of the Shunt-Type Asymmetric Artificial Network
Theoretical and experimental investigations were carried out on the characteristics of the shunt-type asymmetric artificial network (AAN). The findings are as follows: 1) The theoretical formulas for the differential- and common-mode impedances as well as the longitudinal conversion loss (LCL) were derived for the shunt-type AAN in terms of the AAN circuit parameters. 2) The common-mode disturbance voltage estimated from the measured voltage is not proportional to the actual common-mode current flowing in the network cable of the equipment under test (EUT). 3) For the common-mode EUT, the shunt-type AAN with a low LCL of less than about 42 dB yields incorrect measurement results with an error greater than 0.5 dB. 4). A more crucial problem is that, for the differential-mode EUT, the measured disturbance voltage decreases as the EUT common-mode impedance decreases.
- 26 May 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electromagnetic Compatibility
- Vol. 58 (5) , 1526-1534
Technical Problems of the Shunt-Type Asymmetric Artificial Network
Theoretical and experimental investigations were carried out on the characteristics of the shunt-type asymmetric artificial network (AAN). The findings are as follows: 1) The theoretical formulas for the differential- and common-mode impedances as well as the longitudinal conversion loss (LCL) were derived for the shunt-type AAN in terms of the AAN circuit parameters. 2) The common-mode disturbance voltage estimated from the measured voltage is not proportional to the actual common-mode current flowing in the network cable of the equipment under test (EUT). 3) For the common-mode EUT, the shunt-type AAN with a low LCL of less than about 42 dB yields incorrect measurement results with an error greater than 0.5 dB. 4). A more crucial problem is that, for the differential-mode EUT, the measured disturbance voltage decreases as the EUT common-mode impedance decreases.
- Open Access
- 1 January 2004
- Published by American Society for Horticultural Science in Journal of the American Society for Horticultural Science
- Vol. 129 (1) , 42-45
Durian Floral Differentiation and Flowering Habit
Flower bud differentiation and the flowering habit of durian (Durio zibethinus Murray) `Mon Thong' from budbreak to anthesis were investigated at the Chantaburi Horticultural Research Center in Thailand. Clusters of flower buds appeared at the end of November on primary or secondary scaffold branches near where a flower cluster occurred the previous year. Anatomical observations revealed that the development of floral organs was acropetal; the five fused epicalyx forming a large, elongated envelope enclosing the sepals, petals, stamen and fused multi-carpellate pistil. Floral organ development was completed in early January. The mature flower bud more than doubled in size one day before anthesis, with anthesis starting around 1600 hr and ending ≈1900 hr. The anthers did not dehisce until the completion of flowering. This change induced heterostyly in this cultivar, which promoted out-crossing by reducing the possibility of self-pollination. Aromatic nectar that attracted insects to the flower was secreted during anthesis. This is the first report to have clarified the overall flowering process in durian and provides the basic information for elucidating reproductive biology of durian in future research.
- 1 January 2004
- Published by American Society for Horticultural Science in Journal of the American Society for Horticultural Science
- Vol. 129 (1) , 42-45
Open AccessDurian Floral Differentiation and Flowering Habit
Flower bud differentiation and the flowering habit of durian (Durio zibethinus Murray) `Mon Thong' from budbreak to anthesis were investigated at the Chantaburi Horticultural Research Center in Thailand. Clusters of flower buds appeared at the end of November on primary or secondary scaffold branches near where a flower cluster occurred the previous year. Anatomical observations revealed that the development of floral organs was acropetal; the five fused epicalyx forming a large, elongated envelope enclosing the sepals, petals, stamen and fused multi-carpellate pistil. Floral organ development was completed in early January. The mature flower bud more than doubled in size one day before anthesis, with anthesis starting around 1600 hr and ending ≈1900 hr. The anthers did not dehisce until the completion of flowering. This change induced heterostyly in this cultivar, which promoted out-crossing by reducing the possibility of self-pollination. Aromatic nectar that attracted insects to the flower was secreted during anthesis. This is the first report to have clarified the overall flowering process in durian and provides the basic information for elucidating reproductive biology of durian in future research.
- 1 October 1998
- Published by Springer Nature in Economic Botany
- Vol. 52 (4) , 343-351
Diospyros species in Thailand: Their distribution, fruit morphology and uses
- 1 October 1998
- Published by Springer Nature in Economic Botany
- Vol. 52 (4) , 343-351
Diospyros species in Thailand: Their distribution, fruit morphology and uses
- Open Access
- 1 January 1994
- Published by Japanese Society for Horticultural Science in Engei gakkai zasshi (Journal of the Japanese Society for Horticultural Science)
- Vol. 63 (3) , 537-541
Comparison of Growth and Rooting Characteristics of Micropropagated Adult Plants and Juvenile Seedlings of Persimmon (Diospyros kaki L.)
- 1 January 1994
- Published by Japanese Society for Horticultural Science in Engei gakkai zasshi (Journal of the Japanese Society for Horticultural Science)
- Vol. 63 (3) , 537-541
Open AccessComparison of Growth and Rooting Characteristics of Micropropagated Adult Plants and Juvenile Seedlings of Persimmon (Diospyros kaki L.)