Enas Mohamed Abou-Taleb
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Enas Mohamed Abou-Taleb has a total of 29 co-authors. Here are the top co-authors by number of shared publications:
- Mohamed Saad Hellal
Water Pollution Research Department, National Research Centre, Cairo, Egypt
5 shared publications - Kholod Hamdy Kamal
Water Pollution Research Department, National Research Centre, Cairo, Egypt
4 shared publications - Sohair I. Abou-Elela
National Research Centre
4 shared publications - Hanan Sayed Abdel-Rahman
National Research Centre
2 shared publications A.M. Hilmy
1 shared publicationA.Y. Daabees
1 shared publication
Latest Publications
- Open Access
- 15 August 2025
- Published by Springer Nature in Discover Sustainability
- Vol. 6 (1) , 1-16
Assessment of a pilot-scale electrooxidation system for enhanced phenol removal from petroleum refinery wastewater streams
This study demonstrates the successful scale-up of an electro-oxidation (EOX) system for phenol removal from petroleum refinery wastewater, transitioning from laboratory validation to pilot-scale operation. The optimized system, comprising ten parallel reactors with graphite anodes and stainless-steel cathodes, achieved exceptional treatment efficiency across two distinct wastewater streams. During continuous 3-month operation, the system removed 99.9% of phenol at 10 V within 20 min retention time, while simultaneously reducing COD by 50%, BOD by 45–49%, and oil content by 35–50% with initial concentrations of 248 mg/L, 84 mg/L and 13 mg/L, respectively. Performance assessment revealed optimal operation at current densities of 4–6 A/m², with energy consumption averaging 0.45 kWh/m³ for high-TDS streams (1800 mg/L) and 0.25 kWh/m3 for lower-TDS streams (1025 mg/L). Economic analysis showed favorable operating costs of 120–150 kWh per kg of phenol removed, with minimal electrode degradation (< 5% weight change after 3 months).The total operating cost was 0.13–0.15 $/m3 including electricity (0.11$/m3), electrode depreciation (0.05$/ m3), maintenance and cleaning ( 0.08 $/m3) and flow pumping (0.02$/m3). The system maintained stable performance across varying wastewater conditions (pH 6.8–10.3, temperature 21–22 °C), demonstrating its robustness for industrial applications. These findings establish the technical and economic viability of EOX technology for full-scale implementation in petroleum refineries, offering both high removal efficiency and cost-effective operation compared to conventional treatment methods.
- 15 August 2025
- Published by Springer Nature in Discover Sustainability
- Vol. 6 (1) , 1-16
Open AccessAssessment of a pilot-scale electrooxidation system for enhanced phenol removal from petroleum refinery wastewater streams
This study demonstrates the successful scale-up of an electro-oxidation (EOX) system for phenol removal from petroleum refinery wastewater, transitioning from laboratory validation to pilot-scale operation. The optimized system, comprising ten parallel reactors with graphite anodes and stainless-steel cathodes, achieved exceptional treatment efficiency across two distinct wastewater streams. During continuous 3-month operation, the system removed 99.9% of phenol at 10 V within 20 min retention time, while simultaneously reducing COD by 50%, BOD by 45–49%, and oil content by 35–50% with initial concentrations of 248 mg/L, 84 mg/L and 13 mg/L, respectively. Performance assessment revealed optimal operation at current densities of 4–6 A/m², with energy consumption averaging 0.45 kWh/m³ for high-TDS streams (1800 mg/L) and 0.25 kWh/m3 for lower-TDS streams (1025 mg/L). Economic analysis showed favorable operating costs of 120–150 kWh per kg of phenol removed, with minimal electrode degradation (< 5% weight change after 3 months).The total operating cost was 0.13–0.15 $/m3 including electricity (0.11$/m3), electrode depreciation (0.05$/ m3), maintenance and cleaning ( 0.08 $/m3) and flow pumping (0.02$/m3). The system maintained stable performance across varying wastewater conditions (pH 6.8–10.3, temperature 21–22 °C), demonstrating its robustness for industrial applications. These findings establish the technical and economic viability of EOX technology for full-scale implementation in petroleum refineries, offering both high removal efficiency and cost-effective operation compared to conventional treatment methods.
- 7 February 2022
- Published by Egyptian Knowledge Bank in Egyptian Journal of Chemistry
- Vol. 65 (9) , 201-209
Minimize environmental impact of dairy production through improve the life cycle. Part 1: Pollution load from Dairy wastewater in 6 of October Industrial City.
In this study, characterizations of wastewaters produced from Dairy products facilities were investigated. 6th of October industrial zone has been selected as it is the biggest industrial city which includes 2000 registered companies distributed along eleven zones. Dairy industrial sector represents 12 % of total facilities (220 manufacturing facilities) .The main objective of this study is to estimate pollution load produced from dairy industry in different industrial area. Multiple Dairy products are represented such as milk, butter, cheese… etc. The analysis parameters , such as Chemical Oxygen Demand (COD), Biochemical Oxygen Demand (BOD5) , Total Suspended Solids (TSS), alkalinity, turbidity, color and phosphorus. Final effluents were displaying higher values of organic matter than the allowed discharge limits according to the national standards. 90 % of the load from dairy industries is mainly of BOD and COD, which is caused by Lactose concentration. In addition, Cheese whey wastewaters have increased concentrations of BOD and organic matter. In case of discharge, this wastewater, without appropriate treatment, will contaminate water bodies, reducing the lifespan of sewage networks and the efficiency of wastewater treatment plant. Egyptian government has forced exceptionally strict rules Law 93 for the year 1962 and it's Ministerial Decree 44 for the year 2000 and the Egyptian Prime Minister’s law 1012 for the year 2018 for the cost of industrial waste purification. Finally dairy wastewater is heavily polluted with organic load and should be treated before discharging.
- 7 February 2022
- Published by Egyptian Knowledge Bank in Egyptian Journal of Chemistry
- Vol. 65 (9) , 201-209
Minimize environmental impact of dairy production through improve the life cycle. Part 1: Pollution load from Dairy wastewater in 6 of October Industrial City.
In this study, characterizations of wastewaters produced from Dairy products facilities were investigated. 6th of October industrial zone has been selected as it is the biggest industrial city which includes 2000 registered companies distributed along eleven zones. Dairy industrial sector represents 12 % of total facilities (220 manufacturing facilities) .The main objective of this study is to estimate pollution load produced from dairy industry in different industrial area. Multiple Dairy products are represented such as milk, butter, cheese… etc. The analysis parameters , such as Chemical Oxygen Demand (COD), Biochemical Oxygen Demand (BOD5) , Total Suspended Solids (TSS), alkalinity, turbidity, color and phosphorus. Final effluents were displaying higher values of organic matter than the allowed discharge limits according to the national standards. 90 % of the load from dairy industries is mainly of BOD and COD, which is caused by Lactose concentration. In addition, Cheese whey wastewaters have increased concentrations of BOD and organic matter. In case of discharge, this wastewater, without appropriate treatment, will contaminate water bodies, reducing the lifespan of sewage networks and the efficiency of wastewater treatment plant. Egyptian government has forced exceptionally strict rules Law 93 for the year 1962 and it's Ministerial Decree 44 for the year 2000 and the Egyptian Prime Minister’s law 1012 for the year 2018 for the cost of industrial waste purification. Finally dairy wastewater is heavily polluted with organic load and should be treated before discharging.
- 6 July 2020
- Published by Wiley in Water and Environment Journal
- Vol. 35 (1) , 259-268
Electro‐oxidation of phenol in petroleum wastewater using a novel pilot‐scale electrochemical cell with graphite and stainless‐steel electrodes
This work investigated the removal of phenol from petroleum wastewater by the electro‐oxidation process. The experimental design was developed on a pilot‐scale electro‐oxidation system equipped with a cylindrical shape of graphite electrodes as an anode and stainless‐steel electrodes as a cathode. An initial study was performed based on operating variables such as current density and time on real petroleum wastewater. The optimum conditions were obtained as a current density of 3 mA/cm2 and time 15 min. Under these applied optimum conditions, complete phenol removal from an initial concentration of about 6.8 mg/L was achieved. Also, 50–60% removal of organic matter in terms of chemical oxygen demand (COD) and biological oxygen demand (BOD). The removal of organic matter using electro‐oxidation requires a long reaction time. Also, the economic study indicated that the energy consumption was determined to be 0.79 kWh/m3 and the operating cost was 0.051 $/m3 which is very economical compared with conventional methods.
- 6 July 2020
- Published by Wiley in Water and Environment Journal
- Vol. 35 (1) , 259-268
Electro‐oxidation of phenol in petroleum wastewater using a novel pilot‐scale electrochemical cell with graphite and stainless‐steel electrodes
This work investigated the removal of phenol from petroleum wastewater by the electro‐oxidation process. The experimental design was developed on a pilot‐scale electro‐oxidation system equipped with a cylindrical shape of graphite electrodes as an anode and stainless‐steel electrodes as a cathode. An initial study was performed based on operating variables such as current density and time on real petroleum wastewater. The optimum conditions were obtained as a current density of 3 mA/cm2 and time 15 min. Under these applied optimum conditions, complete phenol removal from an initial concentration of about 6.8 mg/L was achieved. Also, 50–60% removal of organic matter in terms of chemical oxygen demand (COD) and biological oxygen demand (BOD). The removal of organic matter using electro‐oxidation requires a long reaction time. Also, the economic study indicated that the energy consumption was determined to be 0.79 kWh/m3 and the operating cost was 0.051 $/m3 which is very economical compared with conventional methods.
- 1 July 2020
- Published by Egyptian Knowledge Bank in Egyptian Journal of Chemistry
- Vol. 63 (7) , 2661-2672
Potential of Food Processing Wastewater Treatment for Reuse
THIS study aimed to investigate the most effective treatment technique for the wastewater generated from food processing factory to be reused according to Egyptian standards. The discharged wastewater was highly polluted by organic load. As presented by average chemical oxygen demands (COD) value of 4950 mgO(2)L(-1). Four treatment scenarios were investigated to select the most appropriate module for reuse of wastewater. Chemical coagulation-flocculation followed by adsorption onto granular activated carbon (GAC) achieved 84% of COD removal. The Fenton oxidation followed by adsorption onto GAC achieved COD removal of 91%.The Aerobic treatment followed by adsorption onto GAC reached to 92% COD removals. The quality of treated effluent using the previous modules was far less than the required values stated in Egyptian code for reuse in agriculture (Grade A). Integration of the studied different treatment modules in the form of sedimentation then chemical coagulation-flocculation followed by aerobic treatment then sandwich filter using adsorption/filtration (Sand/GAC/Sand) produced water quality complying with the Egyptian code for reuse in agriculture with COD removal of 99.8%.
- 1 July 2020
- Published by Egyptian Knowledge Bank in Egyptian Journal of Chemistry
- Vol. 63 (7) , 2661-2672
Potential of Food Processing Wastewater Treatment for Reuse
THIS study aimed to investigate the most effective treatment technique for the wastewater generated from food processing factory to be reused according to Egyptian standards. The discharged wastewater was highly polluted by organic load. As presented by average chemical oxygen demands (COD) value of 4950 mgO(2)L(-1). Four treatment scenarios were investigated to select the most appropriate module for reuse of wastewater. Chemical coagulation-flocculation followed by adsorption onto granular activated carbon (GAC) achieved 84% of COD removal. The Fenton oxidation followed by adsorption onto GAC achieved COD removal of 91%.The Aerobic treatment followed by adsorption onto GAC reached to 92% COD removals. The quality of treated effluent using the previous modules was far less than the required values stated in Egyptian code for reuse in agriculture (Grade A). Integration of the studied different treatment modules in the form of sedimentation then chemical coagulation-flocculation followed by aerobic treatment then sandwich filter using adsorption/filtration (Sand/GAC/Sand) produced water quality complying with the Egyptian code for reuse in agriculture with COD removal of 99.8%.
- 1 February 2020
- Published by Egyptian Knowledge Bank in Egyptian Journal of Chemistry
- Vol. 63 (2) , 405-415
Sustainable solutions for urban wastewater management and remediation
Sustainable development with environmental protection is one of the greatest challenges of the 21st century. There is a growing consideration of the sustainable development and environmental management in new industrial cities. Investigational aspects were carried out in El Obour city as Egyptian new industrial city for estimating the current wastewater problems as well as applying mitigation actions. Industrial inventory was constructed for selected industrial sectors as food, chemical and textile sectors including water consumption, materials and energy resources. Wastewater samples from different factories and lifting stations were analyzed for estimating the industrial effluent loads. The obtained data revealed that food sector represents the highest load for BOD and TSS with values of 80 ton BOD/day and 2.33 ton SS/day. For selected industrial sectors, cost-effective technology is applied to reduce the loads on the centralized wastewater treatment plant (WWTP) as well as on the lifting stations. Inorganic polymeric ferric chloride (POFC) coagulant gives higher removal efficiency for TSS and COD without pH control. Moreover, the chemicals cost for treating wastewater is reduced by 40 % with using POFC instead of conventional coagulants.
- 1 February 2020
- Published by Egyptian Knowledge Bank in Egyptian Journal of Chemistry
- Vol. 63 (2) , 405-415
Sustainable solutions for urban wastewater management and remediation
Sustainable development with environmental protection is one of the greatest challenges of the 21st century. There is a growing consideration of the sustainable development and environmental management in new industrial cities. Investigational aspects were carried out in El Obour city as Egyptian new industrial city for estimating the current wastewater problems as well as applying mitigation actions. Industrial inventory was constructed for selected industrial sectors as food, chemical and textile sectors including water consumption, materials and energy resources. Wastewater samples from different factories and lifting stations were analyzed for estimating the industrial effluent loads. The obtained data revealed that food sector represents the highest load for BOD and TSS with values of 80 ton BOD/day and 2.33 ton SS/day. For selected industrial sectors, cost-effective technology is applied to reduce the loads on the centralized wastewater treatment plant (WWTP) as well as on the lifting stations. Inorganic polymeric ferric chloride (POFC) coagulant gives higher removal efficiency for TSS and COD without pH control. Moreover, the chemicals cost for treating wastewater is reduced by 40 % with using POFC instead of conventional coagulants.
- 25 December 2019
- Published by Egyptian Knowledge Bank in International Journal of Development
- Vol. 8 (1) , 81-83
Methylene blue removal from wastewater using silica/corncob nanocomposite
Silica/corncob nanocomposite was prepared for remove of methylene blue. Fourier transform infrared (FTIR) spectrophotometry, X-ray diffraction (XRD), Scanning electron microscopy (SEM), dispersive energy x-ray spectrometer (EDX), High-resolution transmission electron microscopy (HR-TEM), and Zeta potential measurements were performed to reveal functionality, crystal structure, morphology, and point of zero charge of the synthesized sorbents. The effect of contact time, initial dye concentration, pH and sorbent dose were evaluated to study the removal efficiency and the adsorption capacity for silica/corncob nanocomposite. The equilibrium concentration of dye was measured by spectrophotometer. Adsorption isotherms and kinetics were also evaluated and reported. The removal efficiency of silica/corncob nanocomposite was (98%).
- 25 December 2019
- Published by Egyptian Knowledge Bank in International Journal of Development
- Vol. 8 (1) , 81-83
Methylene blue removal from wastewater using silica/corncob nanocomposite
Silica/corncob nanocomposite was prepared for remove of methylene blue. Fourier transform infrared (FTIR) spectrophotometry, X-ray diffraction (XRD), Scanning electron microscopy (SEM), dispersive energy x-ray spectrometer (EDX), High-resolution transmission electron microscopy (HR-TEM), and Zeta potential measurements were performed to reveal functionality, crystal structure, morphology, and point of zero charge of the synthesized sorbents. The effect of contact time, initial dye concentration, pH and sorbent dose were evaluated to study the removal efficiency and the adsorption capacity for silica/corncob nanocomposite. The equilibrium concentration of dye was measured by spectrophotometer. Adsorption isotherms and kinetics were also evaluated and reported. The removal efficiency of silica/corncob nanocomposite was (98%).
- 1 June 2018
- Published by Egyptian Knowledge Bank in Egyptian Journal of Chemistry
- Vol. 61 (3) , 320-330
Investigation of effective treatment techniques for Olive mill wastewater
Selection of cost-effective treatment modules for high saline wastewater produced from the olive mill is a challenging task. The aim of this study is to select the most effective technology applied to treat Olive mill wastewater. Several trials using various techniques were carried out to treat wastewater produced from pickling olives and olive oil manufacturing; for instance, anaerobic-aerobic, coagulation/flocculation, and electrocoagulation. The characteristics of olive manufacturing raw wastewater in terms of total dissolved solids (TDS), chemical oxygen demand (COD) and oil and grease were 10032, 9174, and 914.8 mg/l respectively. The results showed that electro-coagulation technique with aluminum electrodes and operating parameters of 30 voltage and 1.5 hours achieved COD removal rate 84%. However, the residual concentration (900 mgO2/l) still needs further treatment. Aerobic treatment using activated sludge was applied after electrocoagulation. The results showed that the use aerobic treatment after electrocoagulation is more efficient than the use of anaerobic. Analysis of the treated water showed that the maximum COD removal efficiencies were 98% at optimum conditions. The effluent quality meets the discharge regulatory standard. Consequently, the electrocoagulation followed by aerobic process can be considered as a reliable, safe and cost-effective method for the treatment of olive mill wastewater.
- 1 June 2018
- Published by Egyptian Knowledge Bank in Egyptian Journal of Chemistry
- Vol. 61 (3) , 320-330
Investigation of effective treatment techniques for Olive mill wastewater
Selection of cost-effective treatment modules for high saline wastewater produced from the olive mill is a challenging task. The aim of this study is to select the most effective technology applied to treat Olive mill wastewater. Several trials using various techniques were carried out to treat wastewater produced from pickling olives and olive oil manufacturing; for instance, anaerobic-aerobic, coagulation/flocculation, and electrocoagulation. The characteristics of olive manufacturing raw wastewater in terms of total dissolved solids (TDS), chemical oxygen demand (COD) and oil and grease were 10032, 9174, and 914.8 mg/l respectively. The results showed that electro-coagulation technique with aluminum electrodes and operating parameters of 30 voltage and 1.5 hours achieved COD removal rate 84%. However, the residual concentration (900 mgO2/l) still needs further treatment. Aerobic treatment using activated sludge was applied after electrocoagulation. The results showed that the use aerobic treatment after electrocoagulation is more efficient than the use of anaerobic. Analysis of the treated water showed that the maximum COD removal efficiencies were 98% at optimum conditions. The effluent quality meets the discharge regulatory standard. Consequently, the electrocoagulation followed by aerobic process can be considered as a reliable, safe and cost-effective method for the treatment of olive mill wastewater.
- 25 February 2018
- Published by Wiley in Water and Environment Journal
- Vol. 32 (3) , 404-411
Electrochemical treatment of chemical oxygen demand in produced water using flow‐by porous graphite electrode
Produced water is the largest wastewater stream generated in the oil and gas industries. In this study, experiments were carried out using a bench‐scale electrochemical cell using flow‐by porous graphite electrode, for oxidation of organic matter in produced water which was collected from natural gas processing field (real sample). The effect of anodic current density and influent feed flow rate on chemical oxygen demand (COD) removal efficiency, and energy consumption were investigated. The maximum removal efficiency of 66.52% was obtained for a flow rate of 50 mL/min, current density of 1.41 mA/cm2 and pH of 7.3 for an influent COD of 2845 mg O2/L. The energy consumption at these conditions was 2.12 kWh/kgCOD.
- 25 February 2018
- Published by Wiley in Water and Environment Journal
- Vol. 32 (3) , 404-411
Electrochemical treatment of chemical oxygen demand in produced water using flow‐by porous graphite electrode
Produced water is the largest wastewater stream generated in the oil and gas industries. In this study, experiments were carried out using a bench‐scale electrochemical cell using flow‐by porous graphite electrode, for oxidation of organic matter in produced water which was collected from natural gas processing field (real sample). The effect of anodic current density and influent feed flow rate on chemical oxygen demand (COD) removal efficiency, and energy consumption were investigated. The maximum removal efficiency of 66.52% was obtained for a flow rate of 50 mL/min, current density of 1.41 mA/cm2 and pH of 7.3 for an influent COD of 2845 mg O2/L. The energy consumption at these conditions was 2.12 kWh/kgCOD.
- 1 December 2013
- Published by Elsevier in Ecological Engineering
- Vol. 61, 460-468
Municipal wastewater treatment in horizontal and vertical flows constructed wetlands
- 1 December 2013
- Published by Elsevier in Ecological Engineering
- Vol. 61, 460-468
Municipal wastewater treatment in horizontal and vertical flows constructed wetlands
- 13 April 2010
- Published by Taylor & Francis in Polymer-Plastics Technology and Engineering
- Vol. 49 (5) , 454-461
Synthesis and Characterization of Novel Thermoplastic Films for Removal of Heavy Metal Ions
The main objective of this study is to establish the applicability of novel thermoplastic films based on extracted gelatins from bovine (Gb) and bird (Gc) bones in addition to hide powder (HP), which blended with modified polyethylene (MPE) for the removal of heavy metal ions such as copper (II), chromium (VI), nickel (II) and zinc (II) from aqueous media. The chemical reaction between 2-oxoglutaric acid with furfural in presence of methyl amine, via Mannich reaction mechanism, resulted in chemical compound I. The chemical structure of product I was confirmed by different spectroscopic tools such as: nuclear magnetic resonance (13C- and 1H-NMR) and Fourier transform infrared spectroscopy (FT-IR). The synthesized chemical product I was used as compatibilizing agent for blending Gb, Gc and Hp with MPE to obtain thermoplastic films using a polymer melting technique. The efficiency of the prepared films for absorption of different heavy metal ions from aqueous solution was investigated. The results indicated that the compatibilized films (MPE/I/HP) illustrated a maximum removal of zinc metal ions (∼100%) under conditions of initial metal concentration about 240 mg/l. While, at initial metal concentration of about 150 mg/l, they exhibited excellent efficiency for removal of mixed metal ions of about 97–100% relative to the uncompatibilized ones (MPE/HP) 0%.
- 13 April 2010
- Published by Taylor & Francis in Polymer-Plastics Technology and Engineering
- Vol. 49 (5) , 454-461
Synthesis and Characterization of Novel Thermoplastic Films for Removal of Heavy Metal Ions
The main objective of this study is to establish the applicability of novel thermoplastic films based on extracted gelatins from bovine (Gb) and bird (Gc) bones in addition to hide powder (HP), which blended with modified polyethylene (MPE) for the removal of heavy metal ions such as copper (II), chromium (VI), nickel (II) and zinc (II) from aqueous media. The chemical reaction between 2-oxoglutaric acid with furfural in presence of methyl amine, via Mannich reaction mechanism, resulted in chemical compound I. The chemical structure of product I was confirmed by different spectroscopic tools such as: nuclear magnetic resonance (13C- and 1H-NMR) and Fourier transform infrared spectroscopy (FT-IR). The synthesized chemical product I was used as compatibilizing agent for blending Gb, Gc and Hp with MPE to obtain thermoplastic films using a polymer melting technique. The efficiency of the prepared films for absorption of different heavy metal ions from aqueous solution was investigated. The results indicated that the compatibilized films (MPE/I/HP) illustrated a maximum removal of zinc metal ions (∼100%) under conditions of initial metal concentration about 240 mg/l. While, at initial metal concentration of about 150 mg/l, they exhibited excellent efficiency for removal of mixed metal ions of about 97–100% relative to the uncompatibilized ones (MPE/HP) 0%.