Khalid Z. Rajab
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Khalid Z. Rajab has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
- Akram Alomainy
School of Electronic Engineering and Computer Science, Queen Mary University of London, London, U.K.
3 shared publications - Yang Hao
School of Electronic Engineering and Computer Science, Queen Mary University of London, London, UK
3 shared publications - Elif Dogu
School of Electronic Engineering and Computer Science, Queen Mary University of London, London, UK
2 shared publications - Janelle M. Jones
Centre for Brain and Behaviour, Department of Psychology, School of Biological and Behavioural Sciences, Queen Mary University of London, London, UK
2 shared publications - Jose A. Paredes
School of Computing, Engineering, University of Roehampton, Roehampton Lane, London, United Kingdom
2 shared publications - Miles Hansard
School of EECS, Center for Advanced Robotics (ARQ), Queen Mary University of London, London, U.K.
2 shared publications
Latest Publications
- 1 July 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Internet of Things Journal
- Vol. 13 (13) , 28379-28391
Millimeter-Wave Radar for Remote Health Monitoring: Analyzing Digital Biomarkers for Real-Time Insights
- 1 July 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Internet of Things Journal
- Vol. 13 (13) , 28379-28391
Millimeter-Wave Radar for Remote Health Monitoring: Analyzing Digital Biomarkers for Real-Time Insights
- Open Access
- 5 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in TechRxiv
Millimetre-Wave Radar for Remote Health Monitoring: Analysing Digital Biomarkers for Real-Time Insights
Millimetre-wave (mm-wave) radar technology holds transformative potential in healthcare by enabling continuous, unobtrusive health monitoring, thereby supporting preventative medicine and promoting independent living. Existing remote monitoring approaches, such as wearable devices and mobile applications, face challenges related to user compliance, discomfort, and maintenance, limiting their effectiveness for long-term deployment. This paper presents a mm-wave radar-based system evaluated through a six-month proof-of-concept study in a residential care apartment, demonstrating its real-world feasibility and reliability for continuous long-term home monitoring. The system extracts behavioural parameters and digital biomarkers including room occupancy, movement patterns, gait speed, and activity levels, providing real-time, privacy-preserving insights into an individual’s daily routines and mobility without requiring user interaction. Over the six-month period, the radar sensors successfully tracked mean daily distances moved of 38.6 m in the bedroom and 39.1 m in the living room, while gait speed distributions revealed temporal and spatial variations, with daily median speeds ranging from 0.25–0.55 m/s depending on the time of day. The mean of the daily maximum gait speeds was 0.78 m/s. These findings highlight the system’s capacity for reliable, long-term operation in real-world conditions and its potential as a scalable, maintenance-free solution for continuous health and well-being monitoring in older adults.
- 5 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in TechRxiv
Open AccessMillimetre-Wave Radar for Remote Health Monitoring: Analysing Digital Biomarkers for Real-Time Insights
Millimetre-wave (mm-wave) radar technology holds transformative potential in healthcare by enabling continuous, unobtrusive health monitoring, thereby supporting preventative medicine and promoting independent living. Existing remote monitoring approaches, such as wearable devices and mobile applications, face challenges related to user compliance, discomfort, and maintenance, limiting their effectiveness for long-term deployment. This paper presents a mm-wave radar-based system evaluated through a six-month proof-of-concept study in a residential care apartment, demonstrating its real-world feasibility and reliability for continuous long-term home monitoring. The system extracts behavioural parameters and digital biomarkers including room occupancy, movement patterns, gait speed, and activity levels, providing real-time, privacy-preserving insights into an individual’s daily routines and mobility without requiring user interaction. Over the six-month period, the radar sensors successfully tracked mean daily distances moved of 38.6 m in the bedroom and 39.1 m in the living room, while gait speed distributions revealed temporal and spatial variations, with daily median speeds ranging from 0.25–0.55 m/s depending on the time of day. The mean of the daily maximum gait speeds was 0.78 m/s. These findings highlight the system’s capacity for reliable, long-term operation in real-world conditions and its potential as a scalable, maintenance-free solution for continuous health and well-being monitoring in older adults.
- 11 April 2025
- Published by Springer Nature
- p. 246-255
An IoT System for Continuous Fall Risk Screening at Home with Millimetre-Wave Radar
- 11 April 2025
- Published by Springer Nature
- p. 246-255
An IoT System for Continuous Fall Risk Screening at Home with Millimetre-Wave Radar
- 30 April 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24 (12) , 19407-19416
Spatial Calibration of Millimeter-Wave Radar for Close-Range Object Location
Accurate object detection and location systems are essential for many robotic applications, including autonomous grasping and manipulation systems. In some cases, the target object may be obscured from view, in clutter, packaging, or debris. Millimetre wave radar is a potential alternative to visual sensing in such scenarios, owing to its ability to penetrate typical low-density non-metallic materials. However, this approach requires accurate spatial calibration of the radar signal, over the robot workspace. We propose to achieve this with reference to visual data, which provides ground truth locations for initial training of the system. Specifically, we describe a commodity millimetre wave radar system for detecting and localizing static metallic objects, over a 2D workspace. We compare similarity, affine, and thin-plate spline models of the spatial transformation from radar estimates to actual locations. Experiments were performed with a frequency modulated continuous wave (FMCW)multiple-inputmultiple-output (MIMO) device, using a starting frequency of 60 GHz and a bandwidth of 3.4 GHz. It is shown that the spline model performs best, achieving an average spatial error of 7 mm, which is an order of magnitude lower than that of the uncalibrated system.
- 30 April 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24 (12) , 19407-19416
Spatial Calibration of Millimeter-Wave Radar for Close-Range Object Location
Accurate object detection and location systems are essential for many robotic applications, including autonomous grasping and manipulation systems. In some cases, the target object may be obscured from view, in clutter, packaging, or debris. Millimetre wave radar is a potential alternative to visual sensing in such scenarios, owing to its ability to penetrate typical low-density non-metallic materials. However, this approach requires accurate spatial calibration of the radar signal, over the robot workspace. We propose to achieve this with reference to visual data, which provides ground truth locations for initial training of the system. Specifically, we describe a commodity millimetre wave radar system for detecting and localizing static metallic objects, over a 2D workspace. We compare similarity, affine, and thin-plate spline models of the spatial transformation from radar estimates to actual locations. Experiments were performed with a frequency modulated continuous wave (FMCW)multiple-inputmultiple-output (MIMO) device, using a starting frequency of 60 GHz and a bandwidth of 3.4 GHz. It is shown that the spline model performs best, achieving an average spatial error of 7 mm, which is an order of magnitude lower than that of the uncalibrated system.
- Open Access
- 17 August 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 22 (19) , 18218-18227
A Radar-Based Human Activity Recognition Using a Novel 3-D Point Cloud Classifier
This article provides a new benchmark dataset for 3-D point cloud classification in which the manually labeled human activity data exceeds 100 point clouds per frame and is capable of meeting the training needs for data-intensive learning approaches. In this study, a case study is considered for evaluating the benchmark using a deep long short-term memory (LSTM) neural network, which demonstrated a significant performance improvement over the state-of-the-art human activity recognition (HAR) area. To date, numerous types of collection devices have been used in the recognition of human activities. However, due to the scarcity of training data, the task of 3-D point cloud labeling has not yet made significant progress. To overcome this challenge, it is aimed to deduce this data requirements gap, allowing deep-learning methods to reach their full potential in 3-D point cloud tasks. The dataset used for this process is comprised of dense point clouds acquired with the static ground sensor by the NodeNs company-supported multiple input multiple output (MIMO) radar (NodeNs ZERO 60 GHz IQ radar). It contains multiple types of human being data ranging from one to four individuals and encompasses a range of human action scenarios, including standing, sitting, picking up, falling, and walking. Furthermore, it also investigated sensor locations and requirements for human being data collection that is from a single subject to multiple subjects, as well as identified and analyzed various sensing devices and applications that collect activity data. In this regard, a thorough study is conducted on several benchmark datasets, examining sensors, characteristics, activity categories, and other data. Finally, it compares and analyzes the activity recognition methods used in several benchmark datasets based on the current study. Unlike existing devices, the new NodeNs sensor provides more accessible and straightforward point cloud data to capture human movement information. Depending on an advanced detection algorithm to process point cloud data, it achieved more than 95% accuracy on the benchmark dataset.
- 17 August 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 22 (19) , 18218-18227
Open AccessA Radar-Based Human Activity Recognition Using a Novel 3-D Point Cloud Classifier
This article provides a new benchmark dataset for 3-D point cloud classification in which the manually labeled human activity data exceeds 100 point clouds per frame and is capable of meeting the training needs for data-intensive learning approaches. In this study, a case study is considered for evaluating the benchmark using a deep long short-term memory (LSTM) neural network, which demonstrated a significant performance improvement over the state-of-the-art human activity recognition (HAR) area. To date, numerous types of collection devices have been used in the recognition of human activities. However, due to the scarcity of training data, the task of 3-D point cloud labeling has not yet made significant progress. To overcome this challenge, it is aimed to deduce this data requirements gap, allowing deep-learning methods to reach their full potential in 3-D point cloud tasks. The dataset used for this process is comprised of dense point clouds acquired with the static ground sensor by the NodeNs company-supported multiple input multiple output (MIMO) radar (NodeNs ZERO 60 GHz IQ radar). It contains multiple types of human being data ranging from one to four individuals and encompasses a range of human action scenarios, including standing, sitting, picking up, falling, and walking. Furthermore, it also investigated sensor locations and requirements for human being data collection that is from a single subject to multiple subjects, as well as identified and analyzed various sensing devices and applications that collect activity data. In this regard, a thorough study is conducted on several benchmark datasets, examining sensors, characteristics, activity categories, and other data. Finally, it compares and analyzes the activity recognition methods used in several benchmark datasets based on the current study. Unlike existing devices, the new NodeNs sensor provides more accessible and straightforward point cloud data to capture human movement information. Depending on an advanced detection algorithm to process point cloud data, it achieved more than 95% accuracy on the benchmark dataset.
- 1 December 2021
- Published by Elsevier in Expert Systems with Applications
- Vol. 185
A Gaussian Process model for UAV localization using millimetre wave radar
- 1 December 2021
- Published by Elsevier in Expert Systems with Applications
- Vol. 185
A Gaussian Process model for UAV localization using millimetre wave radar
- 19 July 2021
- Published by AIP Publishing in Applied Physics Letters
- Vol. 119 (3) , 034101
Multi-target tracking and activity classification with millimeter-wave radar
The millimeterwave radar has made possible high resolution tracking, activity classification, and vital signs detection, at higher precisions than is possible with most other wireless approaches. However, detecting multiple moving targets is a challenge, as dynamic scene with a lot of motion leads to clutter and noise, which interfere with the responses of targets of interest. We present a digital beamforming approach using the MIMO radar, with a range resolution of 6.4 cm and a Doppler resolution of 0.18 m/s, which reduces interference between closely neighboring targets. Thus, measurements of individual target micro-Doppler signatures are possible, even in the presence of multiple other moving targets, and the signatures are, thereby, used to train a Deep Neural Network (DNN) for activity classification. The DNN has been applied to recognize six exercise-based classes, correctly predicting with over 95% classification accuracy for all classes, but that is extendable to fall detection and other activities.
- 19 July 2021
- Published by AIP Publishing in Applied Physics Letters
- Vol. 119 (3) , 034101
Multi-target tracking and activity classification with millimeter-wave radar
The millimeterwave radar has made possible high resolution tracking, activity classification, and vital signs detection, at higher precisions than is possible with most other wireless approaches. However, detecting multiple moving targets is a challenge, as dynamic scene with a lot of motion leads to clutter and noise, which interfere with the responses of targets of interest. We present a digital beamforming approach using the MIMO radar, with a range resolution of 6.4 cm and a Doppler resolution of 0.18 m/s, which reduces interference between closely neighboring targets. Thus, measurements of individual target micro-Doppler signatures are possible, even in the presence of multiple other moving targets, and the signatures are, thereby, used to train a Deep Neural Network (DNN) for activity classification. The DNN has been applied to recognize six exercise-based classes, correctly predicting with over 95% classification accuracy for all classes, but that is extendable to fall detection and other activities.
- Open Access
- 15 October 2019
- Published by Optica Publishing Group in Optics Express
- Vol. 27 (22) , 31363-31375
Noise figure of electromagnetic systems with parity and time-reversal symmetry
The primary bottlenecks in designing and implementing PT-symmetric systems at microwave frequency ranges are noise and instability which can weakly break PT-symmetry resulting in system performance degradation. Practical implementation of such systems and devices require significant level of control and stability and it is crucial to analyze the noise performance of such systems in terms of noise figure and signal-to-noise ratio. We describe and develop a simulation model to calculate noise figure of PT-symmetric system and evaluate the performance degradation. We also discuss application design and circuit configurations that could reduce the noise figure resulting in better performance.
- 15 October 2019
- Published by Optica Publishing Group in Optics Express
- Vol. 27 (22) , 31363-31375
Open AccessNoise figure of electromagnetic systems with parity and time-reversal symmetry
The primary bottlenecks in designing and implementing PT-symmetric systems at microwave frequency ranges are noise and instability which can weakly break PT-symmetry resulting in system performance degradation. Practical implementation of such systems and devices require significant level of control and stability and it is crucial to analyze the noise performance of such systems in terms of noise figure and signal-to-noise ratio. We describe and develop a simulation model to calculate noise figure of PT-symmetric system and evaluate the performance degradation. We also discuss application design and circuit configurations that could reduce the noise figure resulting in better performance.
- Open Access
- 11 December 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Antennas and Wireless Propagation Letters
- Vol. 17 (1) , 126-129
FDTD Modeling of Nonlinear Phenomena in Wave Transmission Through Graphene
A novel finite-difference time-domain modeling method is proposed to simulate the nonlinear electrodynamic responses of graphene at terahertz frequencies. The relation between currents in graphene and electromagnetic waves is governed by a ${J - E}$ characteristic formula at the frequencies where the conductivity of graphene exhibits resonant behavior. Simulation results demonstrate nonlinear phenomena in wave transmission through graphene including odd-harmonic generation and frequency-mixing effect. The proposed modeling method can be used as a full-wave solution to the design of nonlinear graphene-based structures.- 11 December 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Antennas and Wireless Propagation Letters
- Vol. 17 (1) , 126-129
Open AccessFDTD Modeling of Nonlinear Phenomena in Wave Transmission Through Graphene
A novel finite-difference time-domain modeling method is proposed to simulate the nonlinear electrodynamic responses of graphene at terahertz frequencies. The relation between currents in graphene and electromagnetic waves is governed by a ${J - E}$ characteristic formula at the frequencies where the conductivity of graphene exhibits resonant behavior. Simulation results demonstrate nonlinear phenomena in wave transmission through graphene including odd-harmonic generation and frequency-mixing effect. The proposed modeling method can be used as a full-wave solution to the design of nonlinear graphene-based structures. - Open Access
- 1 November 2017
- Published by Institution of Engineering and Technology (IET) in Electronics Letters
- Vol. 53 (23) , 1526-1528
Optically reconfigurable unit cell for Ka‐band reflectarray antennas
A new method for achieving amplitude reconfiguration in a reflectarray antenna is presented in this Letter. An individual unit cell is a compact multilayer structure, including a silver inkjet‐printed layer for rapid prototyping of the reflectarray. A small infrared light emitting diode (IR‐LED) illuminating a silicon wafer provides the reconfiguration in the system. Various illumination intensities of the IR‐LED allow for differing magnitudes of reflection from the unit cell. This provides the potential for radiation pattern tapering or amplitude modifications of the gain of the reflectarray. Simulation and measurement results for a single unit cell are presented here, with the matching between measurement and simulation also allowing for the change in the values of conductivity of the silicon to be extracted.
- 1 November 2017
- Published by Institution of Engineering and Technology (IET) in Electronics Letters
- Vol. 53 (23) , 1526-1528
Open AccessOptically reconfigurable unit cell for Ka‐band reflectarray antennas
A new method for achieving amplitude reconfiguration in a reflectarray antenna is presented in this Letter. An individual unit cell is a compact multilayer structure, including a silver inkjet‐printed layer for rapid prototyping of the reflectarray. A small infrared light emitting diode (IR‐LED) illuminating a silicon wafer provides the reconfiguration in the system. Various illumination intensities of the IR‐LED allow for differing magnitudes of reflection from the unit cell. This provides the potential for radiation pattern tapering or amplitude modifications of the gain of the reflectarray. Simulation and measurement results for a single unit cell are presented here, with the matching between measurement and simulation also allowing for the change in the values of conductivity of the silicon to be extracted.