Yew Ming Yeap
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Yew Ming Yeap has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Abhisek Ukil
University of Auckland
21 shared publications - Kuntal Satpathi
Energy Exemplar (Singapore) Pte Ltd., 9 Battery Road, Singapore 049910, Singapore
12 shared publications Nagesh Geddada
7 shared publicationsAbhisek Ukil
4 shared publications- Dongyu Li
School of Electrical and Automation Engineering, East China Jiaotong University, Nanchang, China
2 shared publications Duong Tran
2 shared publications
Latest Publications
- 19 November 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 68 (11) , 11014-11025
Hilbert–Huang Transform Based Transient Analysis in Voltage Source Converter Interfaced Direct Current System
Due to the rapid discharging of the dc-link capacitors, the short-circuit fault normally results in a fastgrowing transient current in the voltage source converter (VSC) based dc power system. Therefore, a fast and sensitive fault detection method is required. In this paper, the feasibility of Hilbert-Huang transform (HHT) for fault detection in VSC-HVDC systems is analyzed. The instantaneous energy density level is used as the fault detection criterion, which emphasizes the fault characteristics in a predefined frequency range and suppresses the effect of steady-state ripple components. The theory of the proposed HHT based fault detection method is presented in detail. Its effectiveness is tested on an OPAL-RT based multi-terminal dc system and a point-to-point experimental dc system. A response delay within 2 ms after the fault inception is achieved. The comparison with other popular frequency-domain based fault detection methods including the wavelet transform, the short time Fourier transform, the S transform and the existing HHT based analysis, using amplitude frequency coefficient as detection criterion underline the performance of the proposed method.
- 19 November 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 68 (11) , 11014-11025
Hilbert–Huang Transform Based Transient Analysis in Voltage Source Converter Interfaced Direct Current System
Due to the rapid discharging of the dc-link capacitors, the short-circuit fault normally results in a fastgrowing transient current in the voltage source converter (VSC) based dc power system. Therefore, a fast and sensitive fault detection method is required. In this paper, the feasibility of Hilbert-Huang transform (HHT) for fault detection in VSC-HVDC systems is analyzed. The instantaneous energy density level is used as the fault detection criterion, which emphasizes the fault characteristics in a predefined frequency range and suppresses the effect of steady-state ripple components. The theory of the proposed HHT based fault detection method is presented in detail. Its effectiveness is tested on an OPAL-RT based multi-terminal dc system and a point-to-point experimental dc system. A response delay within 2 ms after the fault inception is achieved. The comparison with other popular frequency-domain based fault detection methods including the wavelet transform, the short time Fourier transform, the S transform and the existing HHT based analysis, using amplitude frequency coefficient as detection criterion underline the performance of the proposed method.
- 21 April 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 68 (6) , 5024-5035
Improved S Transform-Based Fault Detection Method in Voltage Source Converter Interfaced DC System
The short circuit fault in dc power system typically generate fast-growing transient current which may cause serious damage for dc grid and power electronic equipment. Besides, the protection of dc system is not as mature as the ac system. Thus, dc grid requires a high speed and robust fault detection method. In this paper, a frequency-domain fault detection method is proposed based on S transform (ST), which is able to detect faults within 0.3~ms. It consists of high-frequency detection, which is responsible for fast response due to high time resolution, and low-frequency detection which is used to differentiate faults from other transient conditions. The high-frequency spectrum is obtained by introducing a correction factor into a Gaussian function in the calculation process of ST. This theoretical background of the ST-based fault detection method is presented in details. It is applied to a multi-terminal dc (MTDC) system on MATLAB/Simulink. The simulation results are verified on a point-to-point (P2P) experimental setup with scaled-down voltage. Comparative analysis of the detection time with other dc fault detection methods, namely, based on wavelet transform (WT) and short-time Fourier transform (STFT) substantiates the effectiveness of this method.
- 21 April 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 68 (6) , 5024-5035
Improved S Transform-Based Fault Detection Method in Voltage Source Converter Interfaced DC System
The short circuit fault in dc power system typically generate fast-growing transient current which may cause serious damage for dc grid and power electronic equipment. Besides, the protection of dc system is not as mature as the ac system. Thus, dc grid requires a high speed and robust fault detection method. In this paper, a frequency-domain fault detection method is proposed based on S transform (ST), which is able to detect faults within 0.3~ms. It consists of high-frequency detection, which is responsible for fast response due to high time resolution, and low-frequency detection which is used to differentiate faults from other transient conditions. The high-frequency spectrum is obtained by introducing a correction factor into a Gaussian function in the calculation process of ST. This theoretical background of the ST-based fault detection method is presented in details. It is applied to a multi-terminal dc (MTDC) system on MATLAB/Simulink. The simulation results are verified on a point-to-point (P2P) experimental setup with scaled-down voltage. Comparative analysis of the detection time with other dc fault detection methods, namely, based on wavelet transform (WT) and short-time Fourier transform (STFT) substantiates the effectiveness of this method.
- 14 April 2020
- Published by Springer Nature
- p. 271-302
Introduction to Directional Protection and Communication Assisted Protection Systems
- 14 April 2020
- Published by Springer Nature
- p. 271-302
Introduction to Directional Protection and Communication Assisted Protection Systems
- 14 April 2020
- Published by Springer Nature
- p. 243-270
Non-unit Protection Strategies for DC Power Systems
- 14 April 2020
- Published by Springer Nature
- p. 243-270
Non-unit Protection Strategies for DC Power Systems
- 14 April 2020
- Published by Springer Nature
- p. 169-193
Time-Domain Based Fault Detection in DC Grids
- 14 April 2020
- Published by Springer Nature
- p. 39-81
Components and Architectures of DC Grid for Various Applications
- 14 April 2020
- Published by Springer Nature
- p. 39-81
Components and Architectures of DC Grid for Various Applications
- 14 April 2020
- Published by Springer Nature
- p. 83-122
Modeling and Control of Generation System for DC Grid Applications
- 14 April 2020
- Published by Springer Nature
- p. 83-122
Modeling and Control of Generation System for DC Grid Applications
- 14 April 2020
- Published by Springer Nature
- p. 303-324
Fault Isolation in DC Grids
- 1 October 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 474-479
Analysis of Driving Behavior’s Impact on Battery Discharge Rate for Electric Vehicles
A robust battery management system (BMS) is important for electric vehicle (EV) to preserve the battery health. As EV is gaining popularity as a mode of public transport, the fleet operator should be concerned of optimizing the usage of a fully charged battery, this boils down to the driving behavior. This paper investigates the relation of driving parameters to the battery discharge rate. The driving behavior is associated with vehicle speed, motor speed, throttle position and brake pressure. The data is collected from experiment where the EV is operated through urban roads in Singapore. Principal Component Analysis (PCA) is used to reduce dimensionality of data. We identified an interesting feature in the data distribution, which can be quantified by centroid. Using this feature, we conduct the regression analysis and find out that the centroid has a linear relationship with the duration of battery retaining its state of charge (SOC), which is supported by Pearson correlation coefficient of 0.89 obtained in the analysis.
- 1 October 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 474-479
Analysis of Driving Behavior’s Impact on Battery Discharge Rate for Electric Vehicles
A robust battery management system (BMS) is important for electric vehicle (EV) to preserve the battery health. As EV is gaining popularity as a mode of public transport, the fleet operator should be concerned of optimizing the usage of a fully charged battery, this boils down to the driving behavior. This paper investigates the relation of driving parameters to the battery discharge rate. The driving behavior is associated with vehicle speed, motor speed, throttle position and brake pressure. The data is collected from experiment where the EV is operated through urban roads in Singapore. Principal Component Analysis (PCA) is used to reduce dimensionality of data. We identified an interesting feature in the data distribution, which can be quantified by centroid. Using this feature, we conduct the regression analysis and find out that the centroid has a linear relationship with the duration of battery retaining its state of charge (SOC), which is supported by Pearson correlation coefficient of 0.89 obtained in the analysis.