Rui Pedro A. G. Teixeira
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Rui Pedro A. G. Teixeira has a total of 121 co-authors. Here are the top co-authors by number of shared publications:
- Joseph Hajnal
Research Department of Early Life Imaging, School of Biomedical Engineering and Imaging Sciences, King’s College London, London, UK
12 shared publications - Shaihan J. Malik
School of Biomedical Engineering and Imaging Sciences King's College London London UK
12 shared publications - Anthony N. Price
King's College London
8 shared publications - Jana Hutter
Early Life Imaging Department School of Biomedical Engineering and Imaging Sciences, King's College London London UK
5 shared publications Joseph V. Hajnal
Department of Biomedical Engineering School of Biomedical Engineering and Imaging Sciences King’s College London, St. Thomas’ Hospital London United Kingdom
4 shared publications- Lucilio Cordero-Grande
Research Department of Early Life Imaging, School of Biomedical Engineering and Imaging Sciences, King’s College London, London, UK
4 shared publications
Latest Publications
- Open Access
- 8 October 2025
- Published by MIT Press in Imaging Neuroscience
- Vol. 3
Repeatability and reproducibility of rapid T1 mapping of brain tissues at 64 mT: A multicentre study
Very-low-field MRI (<100 mT) holds promise for Point-of-Care brain imaging applications, including stroke and multiple sclerosis, with T1 mapping emerging as a key biomarker for brain development and pathology. However, current low-field T1 mapping protocols suffer from long acquisition times and limited multi-site repeatability. This study aimed to improve T1 mapping at 64 mT using a clinically feasible 10-minute protocol and assess repeatability and reproducibility across sites. We present an analysis of the repeatability and reproducibility of rapid T1 measurements in a commercially available phantom and in 60 volunteers, scanned with a portable 64 mT MRI systems at six sites. T1 mapping was performed using an undersampled 3D inversion-recovery turbo spin-echo sequence with a 10.8-minute scan time, and reconstructed with a locally low-rank approach. Our results in phantom demonstrated high reproducibility in T1 measurements (below 3% differences from the average), with non-significant differences between sites. Longitudinal measurements demonstrated high repeatability over time both in vivo and in phantom settings in one site, with minimal variability (average Coefficient of Variation of 0.6%). Average in vivo T1 values for white matter and cortex were 290 ± 6 ms and 332 ± 8 ms, respectively and the values demonstrated high reproducibility, with differences of less than 4% from the average across sites. Our results demonstrate the feasibility of multi-site in vivo T1 mapping at 64 mT, providing normative T1 values at this field strength and supporting its use as a quantitative biomarker in clinical applications.
- 8 October 2025
- Published by MIT Press in Imaging Neuroscience
- Vol. 3
Open AccessRepeatability and reproducibility of rapid T1 mapping of brain tissues at 64 mT: A multicentre study
Very-low-field MRI (<100 mT) holds promise for Point-of-Care brain imaging applications, including stroke and multiple sclerosis, with T1 mapping emerging as a key biomarker for brain development and pathology. However, current low-field T1 mapping protocols suffer from long acquisition times and limited multi-site repeatability. This study aimed to improve T1 mapping at 64 mT using a clinically feasible 10-minute protocol and assess repeatability and reproducibility across sites. We present an analysis of the repeatability and reproducibility of rapid T1 measurements in a commercially available phantom and in 60 volunteers, scanned with a portable 64 mT MRI systems at six sites. T1 mapping was performed using an undersampled 3D inversion-recovery turbo spin-echo sequence with a 10.8-minute scan time, and reconstructed with a locally low-rank approach. Our results in phantom demonstrated high reproducibility in T1 measurements (below 3% differences from the average), with non-significant differences between sites. Longitudinal measurements demonstrated high repeatability over time both in vivo and in phantom settings in one site, with minimal variability (average Coefficient of Variation of 0.6%). Average in vivo T1 values for white matter and cortex were 290 ± 6 ms and 332 ± 8 ms, respectively and the values demonstrated high reproducibility, with differences of less than 4% from the average across sites. Our results demonstrate the feasibility of multi-site in vivo T1 mapping at 64 mT, providing normative T1 values at this field strength and supporting its use as a quantitative biomarker in clinical applications.
- Open Access
- 16 April 2024
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 92 (2) , 715-729
In vivo T2 measurements of the fetal brain using single‐shot fast spin echo sequences
Purpose: We propose a quantitative framework for motion‐corrected T2 fetal brain measurements in vivo and validate the single‐shot fast spin echo (SS‐FSE) sequence to perform these measurements.Methods: Stacks of two‐dimensional SS‐FSE slices are acquired with different echo times (TE) and motion‐corrected with slice‐to‐volume reconstruction (SVR). The quantitative T2 maps are obtained by a fit to a dictionary of simulated signals. The sequence is selected using simulated experiments on a numerical phantom and validated on a physical phantom scanned on a 1.5T system. In vivo quantitative T2 maps are obtained for five fetuses with gestational ages (GA) 21–35 weeks on the same 1.5T system.Results: The simulated experiments suggested that a TE of 400 ms combined with the clinically utilized TEs of 80 and 180 ms were most suitable for T2 measurements in the fetal brain. The validation on the physical phantom confirmed that the SS‐FSE T2 measurements match the gold standard multi‐echo spin echo measurements. We measured average T2s of around 200 and 280 ms in the fetal brain grey and white matter, respectively. This was slightly higher than fetal T2* and the neonatal T2 obtained from previous studies.Conclusion: The motion‐corrected SS‐FSE acquisitions with varying TEs offer a promising practical framework for quantitative T2 measurements of the moving fetus.
- 16 April 2024
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 92 (2) , 715-729
Open AccessIn vivo T2 measurements of the fetal brain using single‐shot fast spin echo sequences
Purpose: We propose a quantitative framework for motion‐corrected T2 fetal brain measurements in vivo and validate the single‐shot fast spin echo (SS‐FSE) sequence to perform these measurements.Methods: Stacks of two‐dimensional SS‐FSE slices are acquired with different echo times (TE) and motion‐corrected with slice‐to‐volume reconstruction (SVR). The quantitative T2 maps are obtained by a fit to a dictionary of simulated signals. The sequence is selected using simulated experiments on a numerical phantom and validated on a physical phantom scanned on a 1.5T system. In vivo quantitative T2 maps are obtained for five fetuses with gestational ages (GA) 21–35 weeks on the same 1.5T system.Results: The simulated experiments suggested that a TE of 400 ms combined with the clinically utilized TEs of 80 and 180 ms were most suitable for T2 measurements in the fetal brain. The validation on the physical phantom confirmed that the SS‐FSE T2 measurements match the gold standard multi‐echo spin echo measurements. We measured average T2s of around 200 and 280 ms in the fetal brain grey and white matter, respectively. This was slightly higher than fetal T2* and the neonatal T2 obtained from previous studies.Conclusion: The motion‐corrected SS‐FSE acquisitions with varying TEs offer a promising practical framework for quantitative T2 measurements of the moving fetus.
- Open Access
- 21 August 2021
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 87 (1) , 220-235
An MR fingerprinting approach for quantitative inhomogeneous magnetization transfer imaging
Purpose: Magnetization transfer (MT) and inhomogeneous MT (ihMT) contrasts are used in MRI to provide information about macromolecular tissue content. In particular, MT is sensitive to macromolecules, and ihMT appears to be specific to myelinated tissue. This study proposes a technique to characterize MT and ihMT properties from a single acquisition, producing both semiquantitative contrast ratios and quantitative parameter maps.Theory and Methods: Building on previous work that uses multiband RF pulses to efficiently generate ihMT contrast, we propose a cyclic steady‐state approach that cycles between multiband and single‐band pulses to boost the achieved contrast. Resultant time‐variable signals are reminiscent of an MR fingerprinting acquisition, except that the signal fluctuations are entirely mediated by MT effects. A dictionary‐based low‐rank inversion method is used to reconstruct the resulting images and to produce both semiquantitative MT ratio and ihMT ratio maps, as well as quantitative parameter estimates corresponding to an ihMT tissue model.Results: Phantom and in vivo brain data acquired at 1.5 Tesla demonstrate the expected contrast trends, with ihMT ratio maps showing contrast more specific to white matter, as has been reported by others. Quantitative estimation of semisolid fraction and dipolar T1 was also possible and yielded measurements consistent with literature values in the brain.Conclusion: By cycling between multiband and single‐band pulses, an entirely MT‐mediated fingerprinting method was demonstrated. This proof‐of‐concept approach can be used to generate semiquantitative maps and quantitatively estimate some macromolecular‐specific tissue parameters.
- 21 August 2021
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 87 (1) , 220-235
Open AccessAn MR fingerprinting approach for quantitative inhomogeneous magnetization transfer imaging
Purpose: Magnetization transfer (MT) and inhomogeneous MT (ihMT) contrasts are used in MRI to provide information about macromolecular tissue content. In particular, MT is sensitive to macromolecules, and ihMT appears to be specific to myelinated tissue. This study proposes a technique to characterize MT and ihMT properties from a single acquisition, producing both semiquantitative contrast ratios and quantitative parameter maps.Theory and Methods: Building on previous work that uses multiband RF pulses to efficiently generate ihMT contrast, we propose a cyclic steady‐state approach that cycles between multiband and single‐band pulses to boost the achieved contrast. Resultant time‐variable signals are reminiscent of an MR fingerprinting acquisition, except that the signal fluctuations are entirely mediated by MT effects. A dictionary‐based low‐rank inversion method is used to reconstruct the resulting images and to produce both semiquantitative MT ratio and ihMT ratio maps, as well as quantitative parameter estimates corresponding to an ihMT tissue model.Results: Phantom and in vivo brain data acquired at 1.5 Tesla demonstrate the expected contrast trends, with ihMT ratio maps showing contrast more specific to white matter, as has been reported by others. Quantitative estimation of semisolid fraction and dipolar T1 was also possible and yielded measurements consistent with literature values in the brain.Conclusion: By cycling between multiband and single‐band pulses, an entirely MT‐mediated fingerprinting method was demonstrated. This proof‐of‐concept approach can be used to generate semiquantitative maps and quantitatively estimate some macromolecular‐specific tissue parameters.
- Open Access
- 26 July 2021
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 66 (15) , 15NT02
Efficiency analysis for quantitative MRI of T1 and T2 relaxometry methods
This study presents a comparison of quantitative MRI methods based on an efficiency metric that quantifies their intrinsic ability to extract information about tissue parameters. Under a regime of unbiased parameter estimates, an intrinsic efficiency metric η was derived for fully-sampled experiments which can be used to both optimize and compare sequences. Here we optimize and compare several steady-state and transient gradient-echo based qMRI methods, such as magnetic resonance fingerprinting (MRF), for joint T 1 and T 2 mapping. The impact of undersampling was also evaluated, assuming incoherent aliasing that is treated as noise by parameter estimation. In vivo validation of the efficiency metric was also performed. Transient methods such as MRF can be up to 3.5 times more efficient than steady-state methods, when spatial undersampling is ignored. If incoherent aliasing is treated as noise during least-squares parameter estimation, the efficiency is reduced in proportion to the SNR of the data, with reduction factors of 5 often seen for practical SNR levels. In vivo validation showed a very good agreement between the theoretical and experimentally predicted efficiency. This work presents and validates an efficiency metric to optimize and compare the performance of qMRI methods. Transient methods were found to be intrinsically more efficient than steady-state methods, however the effect of spatial undersampling can significantly erode this advantage.
- 26 July 2021
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 66 (15) , 15NT02
Open AccessEfficiency analysis for quantitative MRI of T1 and T2 relaxometry methods
This study presents a comparison of quantitative MRI methods based on an efficiency metric that quantifies their intrinsic ability to extract information about tissue parameters. Under a regime of unbiased parameter estimates, an intrinsic efficiency metric η was derived for fully-sampled experiments which can be used to both optimize and compare sequences. Here we optimize and compare several steady-state and transient gradient-echo based qMRI methods, such as magnetic resonance fingerprinting (MRF), for joint T 1 and T 2 mapping. The impact of undersampling was also evaluated, assuming incoherent aliasing that is treated as noise by parameter estimation. In vivo validation of the efficiency metric was also performed. Transient methods such as MRF can be up to 3.5 times more efficient than steady-state methods, when spatial undersampling is ignored. If incoherent aliasing is treated as noise during least-squares parameter estimation, the efficiency is reduced in proportion to the SNR of the data, with reduction factors of 5 often seen for practical SNR levels. In vivo validation showed a very good agreement between the theoretical and experimentally predicted efficiency. This work presents and validates an efficiency metric to optimize and compare the performance of qMRI methods. Transient methods were found to be intrinsically more efficient than steady-state methods, however the effect of spatial undersampling can significantly erode this advantage.
- 6 July 2021
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 86 (5) , 2426-2440
Improving parametric estimation in the brain from multispin‐echo sequences using a fusion bootstrap moves solver
Purpose To simultaneously estimate the field (along with the T2) in the brain with multispin-echo (MSE) sequences and dictionary matching. Methods T2 mapping provides clinically relevant information such as in the assessment of brain degenerative diseases. It is commonly obtained with MSE sequences, and accuracy can be further improved by matching the MSE signal to a precomputed dictionary of echo-modulation curves. For additional T1 quantification, transmit field knowledge is also required. Preliminary work has shown that although simultaneous brain estimation along with T2 is possible, it presents a bimodal distribution with the main peak coinciding with the true value. By taking advantage of this, the maps are expected to be spatially smooth by applying an iterative method that takes into account each pixel neighborhood known as the fusion bootstrap moves solver (FBMS). The effect of the FBMS on accuracy and piecewise smoothness is investigated and different spatial regularization levels are compared. Total variation regularization was used for both and T2 simultaneous estimation because of its simplicity as an initial proof-of-concept; future work could explore non edge-preserving regularization independently for . Results Improvements in accuracy (up to 45.37% and 16.81% error decrease) and recovery of spatially homogeneous maps are shown in simulations and in vivo 3.0T brain data, respectively. Conclusion Accurate estimated values can be obtained from widely available MSE sequences while jointly estimating T2 maps with the use of echo-modulation curve matching and FBMS at no further cost.
- 6 July 2021
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 86 (5) , 2426-2440
Improving parametric estimation in the brain from multispin‐echo sequences using a fusion bootstrap moves solver
Purpose To simultaneously estimate the field (along with the T2) in the brain with multispin-echo (MSE) sequences and dictionary matching. Methods T2 mapping provides clinically relevant information such as in the assessment of brain degenerative diseases. It is commonly obtained with MSE sequences, and accuracy can be further improved by matching the MSE signal to a precomputed dictionary of echo-modulation curves. For additional T1 quantification, transmit field knowledge is also required. Preliminary work has shown that although simultaneous brain estimation along with T2 is possible, it presents a bimodal distribution with the main peak coinciding with the true value. By taking advantage of this, the maps are expected to be spatially smooth by applying an iterative method that takes into account each pixel neighborhood known as the fusion bootstrap moves solver (FBMS). The effect of the FBMS on accuracy and piecewise smoothness is investigated and different spatial regularization levels are compared. Total variation regularization was used for both and T2 simultaneous estimation because of its simplicity as an initial proof-of-concept; future work could explore non edge-preserving regularization independently for . Results Improvements in accuracy (up to 45.37% and 16.81% error decrease) and recovery of spatially homogeneous maps are shown in simulations and in vivo 3.0T brain data, respectively. Conclusion Accurate estimated values can be obtained from widely available MSE sequences while jointly estimating T2 maps with the use of echo-modulation curve matching and FBMS at no further cost.
- Open Access
- 5 April 2021
- Published by Oxford University Press (OUP) in Cerebral Cortex
- Vol. 31 (8) , 3665-3677
Phenotyping the Preterm Brain: Characterizing Individual Deviations From Normative Volumetric Development in Two Large Infant Cohorts
The diverse cerebral consequences of preterm birth create significant challenges for understanding pathogenesis or predicting later outcome. Instead of focusing on describing effects common to the group, comparing individual infants against robust normative data offers a powerful alternative to study brain maturation. Here we used Gaussian process regression to create normative curves characterizing brain volumetric development in 274 term-born infants, modeling for age at scan and sex. We then compared 89 preterm infants scanned at term-equivalent age with these normative charts, relating individual deviations from typical volumetric development to perinatal risk factors and later neurocognitive scores. To test generalizability, we used a second independent dataset comprising of 253 preterm infants scanned using different acquisition parameters and scanner. We describe rapid, nonuniform brain growth during the neonatal period. In both preterm cohorts, cerebral atypicalities were widespread, often multiple, and varied highly between individuals. Deviations from normative development were associated with respiratory support, nutrition, birth weight, and later neurocognition, demonstrating their clinical relevance. Group-level understanding of the preterm brain disguises a large degree of individual differences. We provide a method and normative dataset that offer a more precise characterization of the cerebral consequences of preterm birth by profiling the individual neonatal brain.
- 5 April 2021
- Published by Oxford University Press (OUP) in Cerebral Cortex
- Vol. 31 (8) , 3665-3677
Open AccessPhenotyping the Preterm Brain: Characterizing Individual Deviations From Normative Volumetric Development in Two Large Infant Cohorts
The diverse cerebral consequences of preterm birth create significant challenges for understanding pathogenesis or predicting later outcome. Instead of focusing on describing effects common to the group, comparing individual infants against robust normative data offers a powerful alternative to study brain maturation. Here we used Gaussian process regression to create normative curves characterizing brain volumetric development in 274 term-born infants, modeling for age at scan and sex. We then compared 89 preterm infants scanned at term-equivalent age with these normative charts, relating individual deviations from typical volumetric development to perinatal risk factors and later neurocognitive scores. To test generalizability, we used a second independent dataset comprising of 253 preterm infants scanned using different acquisition parameters and scanner. We describe rapid, nonuniform brain growth during the neonatal period. In both preterm cohorts, cerebral atypicalities were widespread, often multiple, and varied highly between individuals. Deviations from normative development were associated with respiratory support, nutrition, birth weight, and later neurocognition, demonstrating their clinical relevance. Group-level understanding of the preterm brain disguises a large degree of individual differences. We provide a method and normative dataset that offer a more precise characterization of the cerebral consequences of preterm birth by profiling the individual neonatal brain.
- Open Access
- 17 November 2020
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 85 (4) , 2069-2083
Quantitative magnetization transfer imaging for non‐contrast enhanced detection of myocardial fibrosis
Purpose: To develop a novel gadolinium‐free model‐based quantitative magnetization transfer (qMT) technique to assess macromolecular changes associated with myocardial fibrosis.Methods: The proposed sequence consists of a two‐dimensional breath‐held dual shot interleaved acquisition of five MT‐weighted (MTw) spoiled gradient echo images, with variable MT flip angles (FAs) and off‐resonance frequencies. A two‐pool exchange model and dictionary matching were used to quantify the pool size ratio (PSR) and bound pool T2 relaxation (). The signal model was developed and validated using 25 MTw images on a bovine serum albumin (BSA) phantom and in vivo human thigh muscle. A protocol with five MTw images was optimized for single breath‐hold cardiac qMT imaging. The proposed sequence was tested in 10 healthy subjects and 5 patients with myocardial fibrosis and compared to late gadolinium enhancement (LGE).Results: PSR values in the BSA phantom were within the confidence interval of previously reported values (concentration 10% BSA = 5.9 ± 0.1%, 15% BSA = 9.4 ± 0.2%). PSR and in thigh muscle were also in agreement with literature (PSR = 10.9 ± 0.3%, = 6.4 ± 0.4 us). In 10 healthy subjects, global left ventricular PSR was 4.30 ± 0.65%. In patients, PSR was reduced in areas associated with LGE (remote: 4.68 ± 0.70% vs. fibrotic: 3.12 ± 0.78 %, n = 5, P < .002).Conclusion: In vivo model‐based qMT mapping of the heart was performed for the first time, with promising results for non‐contrast enhanced assessment of myocardial fibrosis.
- 17 November 2020
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 85 (4) , 2069-2083
Open AccessQuantitative magnetization transfer imaging for non‐contrast enhanced detection of myocardial fibrosis
Purpose: To develop a novel gadolinium‐free model‐based quantitative magnetization transfer (qMT) technique to assess macromolecular changes associated with myocardial fibrosis.Methods: The proposed sequence consists of a two‐dimensional breath‐held dual shot interleaved acquisition of five MT‐weighted (MTw) spoiled gradient echo images, with variable MT flip angles (FAs) and off‐resonance frequencies. A two‐pool exchange model and dictionary matching were used to quantify the pool size ratio (PSR) and bound pool T2 relaxation (). The signal model was developed and validated using 25 MTw images on a bovine serum albumin (BSA) phantom and in vivo human thigh muscle. A protocol with five MTw images was optimized for single breath‐hold cardiac qMT imaging. The proposed sequence was tested in 10 healthy subjects and 5 patients with myocardial fibrosis and compared to late gadolinium enhancement (LGE).Results: PSR values in the BSA phantom were within the confidence interval of previously reported values (concentration 10% BSA = 5.9 ± 0.1%, 15% BSA = 9.4 ± 0.2%). PSR and in thigh muscle were also in agreement with literature (PSR = 10.9 ± 0.3%, = 6.4 ± 0.4 us). In 10 healthy subjects, global left ventricular PSR was 4.30 ± 0.65%. In patients, PSR was reduced in areas associated with LGE (remote: 4.68 ± 0.70% vs. fibrotic: 3.12 ± 0.78 %, n = 5, P < .002).Conclusion: In vivo model‐based qMT mapping of the heart was performed for the first time, with promising results for non‐contrast enhanced assessment of myocardial fibrosis.
- Open Access
- 10 September 2020
- Published by Cold Spring Harbor Laboratory in medRxiv
Evaluation of DISORDER: retrospective image motion correction for volumetric brain MRI in a pediatric setting
Background and Purpose: Head motion causes image degradation in brain MRI examinations, negatively impacting image quality, especially in pediatric populations. Here, we used a retrospective motion correction technique in children and assessed image quality improvement for 3D MRI acquisitions.Material and Methods: We prospectively acquired brain MRI at 3T using 3D sequences, T1-weighted MPRAGE, T2-weighted Turbo Spin Echo and FLAIR, in 32 unsedated children, including 7 with epilepsy (age range 2–18 years). We implemented a novel motion correction technique: Distributed and Incoherent Sample Orders for Reconstruction Deblurring using Encoding Redundancy (DISORDER). For each subject and modality, we obtained 3 reconstructions: as acquired (Aq), after DISORDER motion correction (Di), and Di with additional outlier rejection (DiOut).We analyzed 288 images quantitatively, measuring 2 objective no-reference image quality metrics: Gradient Entropy (GE) and MPRAGE White Matter Homogeneity (WM-H). As a qualitative metric, we presented blinded and randomized images to 2 expert neuroradiologists who scored them for clinical readability.Results: Both image quality metrics improved after motion correction for all modalities and improvement correlated with the amount of intrascan motion. Neuroradiologists also considered the motion corrected images as of higher quality (Wilcoxon’s z = −3.164 MPRAGE, z = −2.066 TSE, z = −2.645 FLAIR, for all p < 0.05).Conclusions: Retrospective image motion correction with DISORDER increased image quality both from an objective and qualitative perspective. In 75% of sessions, at least one sequence was improved by this approach, indicating the benefit of this technique in unsedated children for both clinical and research environments.
- 10 September 2020
- Published by Cold Spring Harbor Laboratory in medRxiv
Open AccessEvaluation of DISORDER: retrospective image motion correction for volumetric brain MRI in a pediatric setting
Background and Purpose: Head motion causes image degradation in brain MRI examinations, negatively impacting image quality, especially in pediatric populations. Here, we used a retrospective motion correction technique in children and assessed image quality improvement for 3D MRI acquisitions.Material and Methods: We prospectively acquired brain MRI at 3T using 3D sequences, T1-weighted MPRAGE, T2-weighted Turbo Spin Echo and FLAIR, in 32 unsedated children, including 7 with epilepsy (age range 2–18 years). We implemented a novel motion correction technique: Distributed and Incoherent Sample Orders for Reconstruction Deblurring using Encoding Redundancy (DISORDER). For each subject and modality, we obtained 3 reconstructions: as acquired (Aq), after DISORDER motion correction (Di), and Di with additional outlier rejection (DiOut).We analyzed 288 images quantitatively, measuring 2 objective no-reference image quality metrics: Gradient Entropy (GE) and MPRAGE White Matter Homogeneity (WM-H). As a qualitative metric, we presented blinded and randomized images to 2 expert neuroradiologists who scored them for clinical readability.Results: Both image quality metrics improved after motion correction for all modalities and improvement correlated with the amount of intrascan motion. Neuroradiologists also considered the motion corrected images as of higher quality (Wilcoxon’s z = −3.164 MPRAGE, z = −2.066 TSE, z = −2.645 FLAIR, for all p < 0.05).Conclusions: Retrospective image motion correction with DISORDER increased image quality both from an objective and qualitative perspective. In 75% of sessions, at least one sequence was improved by this approach, indicating the benefit of this technique in unsedated children for both clinical and research environments.
- Open Access
Phenotyping the preterm brain: characterising individual deviations from normative volumetric development in two large infant cohorts
The diverse cerebral consequences of preterm birth create significant challenges for understanding pathogenesis or predicting later outcome. Instead of focusing on describing effects common to the group, comparing individual infants against robust normative data offers a powerful alternative to study brain maturation. Here we used Gaussian process regression to create normative curves characterising brain volumetric development in 274 term-born infants, modelling for age at scan and sex. We then compared 89 preterm infants scanned at termequivalent age to these normative charts, relating individual deviations from typical volumetric development to perinatal risk factors and later neurocognitive scores. To test generalisability, we used a second independent dataset comprising of 253 preterm infants scanned using different acquisition parameters and scanner. We describe rapid, non-uniform brain growth during the neonatal period. In both preterm cohorts, cerebral atypicalities were widespread, often multiple, and varied highly between individuals. Deviations from normative development were associated with respiratory support, nutrition, birth weight, and later neurocognition, demonstrating their clinical relevance. Group-level understanding of the preterm brain disguise a large degree of individual differences. We provide a method and normative dataset that offer a more precise characterisation of the cerebral consequences of preterm birth by profiling the individual neonatal brain.
Open AccessPhenotyping the preterm brain: characterising individual deviations from normative volumetric development in two large infant cohorts
The diverse cerebral consequences of preterm birth create significant challenges for understanding pathogenesis or predicting later outcome. Instead of focusing on describing effects common to the group, comparing individual infants against robust normative data offers a powerful alternative to study brain maturation. Here we used Gaussian process regression to create normative curves characterising brain volumetric development in 274 term-born infants, modelling for age at scan and sex. We then compared 89 preterm infants scanned at termequivalent age to these normative charts, relating individual deviations from typical volumetric development to perinatal risk factors and later neurocognitive scores. To test generalisability, we used a second independent dataset comprising of 253 preterm infants scanned using different acquisition parameters and scanner. We describe rapid, non-uniform brain growth during the neonatal period. In both preterm cohorts, cerebral atypicalities were widespread, often multiple, and varied highly between individuals. Deviations from normative development were associated with respiratory support, nutrition, birth weight, and later neurocognition, demonstrating their clinical relevance. Group-level understanding of the preterm brain disguise a large degree of individual differences. We provide a method and normative dataset that offer a more precise characterisation of the cerebral consequences of preterm birth by profiling the individual neonatal brain.
- Open Access
- 3 January 2020
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 84 (2) , 713-726
Motion‐corrected MRI with DISORDER: Distributed and incoherent sample orders for reconstruction deblurring using encoding redundancy
Purpose: To enable rigid body motion‐tolerant parallel volumetric magnetic resonance imaging by retrospective head motion correction on a variety of spatiotemporal scales and imaging sequences.Theory and methods: Tolerance against rigid body motion is based on distributed and incoherent sampling orders for boosting a joint retrospective motion estimation and reconstruction framework. Motion resilience stems from the encoding redundancy in the data, as generally provided by the coil array. Hence, it does not require external sensors, navigators or training data, so the methodology is readily applicable to sequences using 3D encodings.Results: Simulations are performed showing full inter‐shot corrections for usual levels of in vivo motion, large number of shots, standard levels of noise and moderate acceleration factors. Feasibility of inter‐ and intra‐shot corrections is shown under controlled motion in vivo. Practical efficacy is illustrated by high‐quality results in most corrupted of 208 volumes from a series of 26 clinical pediatric examinations collected using standard protocols.Conclusions: The proposed framework addresses the rigid motion problem in volumetric anatomical brain scans with sufficient encoding redundancy which has enabled reliable pediatric examinations without sedation.
- 3 January 2020
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 84 (2) , 713-726
Open AccessMotion‐corrected MRI with DISORDER: Distributed and incoherent sample orders for reconstruction deblurring using encoding redundancy
Purpose: To enable rigid body motion‐tolerant parallel volumetric magnetic resonance imaging by retrospective head motion correction on a variety of spatiotemporal scales and imaging sequences.Theory and methods: Tolerance against rigid body motion is based on distributed and incoherent sampling orders for boosting a joint retrospective motion estimation and reconstruction framework. Motion resilience stems from the encoding redundancy in the data, as generally provided by the coil array. Hence, it does not require external sensors, navigators or training data, so the methodology is readily applicable to sequences using 3D encodings.Results: Simulations are performed showing full inter‐shot corrections for usual levels of in vivo motion, large number of shots, standard levels of noise and moderate acceleration factors. Feasibility of inter‐ and intra‐shot corrections is shown under controlled motion in vivo. Practical efficacy is illustrated by high‐quality results in most corrupted of 208 volumes from a series of 26 clinical pediatric examinations collected using standard protocols.Conclusions: The proposed framework addresses the rigid motion problem in volumetric anatomical brain scans with sufficient encoding redundancy which has enabled reliable pediatric examinations without sedation.