Arnoud Frumau
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Arnoud Frumau has a total of 361 co-authors. Here are the top co-authors by number of shared publications:
- Simon O'DOherty
School of Chemistry, University of Bristol, Bristol, UK
18 shared publications - Kieran M. Stanley
School of Chemistry, University of Bristol, Bristol, UK
16 shared publications - Alistair Manning
Hadley Centre, Met Office, Exeter, UK
15 shared publications - Dickon Young
School of Chemistry, University of Bristol, Bristol BS8 1TS, United Kingdom
15 shared publications - Anita L. Ganesan
School of Geographical Sciences, University of Bristol, Bristol, UK
14 shared publications - Joseph Pitt
School of Chemistry, University of Bristol, Bristol, UK
14 shared publications
Latest Publications
- Open Access
- 29 October 2026
- Published by Copernicus GmbH in Atmospheric Measurement Techniques
- Vol. 19 (20) , 6823-6856
Review of the Radon Tracer Method for GHG emission estimates: development, application guidelines, improvements, and caveats
The Radon Tracer Method (RTM) is an established, independent top-down method that can be used to cross-check bottom-up greenhouse gas (GHG) emission estimates. Furthermore, as uncertainties of Atmospheric Transport Models are reduced, the RTM can provide a convenient means of quantifying continual improvement of inversion-based top-down GHG emission estimates. While the accessibility and perceived simplicity of the RTM drive its popularity, the technique is better suited to assessing long-term relative changes in GHG emissions than absolute changes, due to short-term soil moisture influences on simulated radon flux uncertainty. Considerations for applying the RTM, based on fundamental assumptions of the technique's development, are application and season specific, making the development of a “standard protocol” for its use challenging. After proposing a novel alternative means of applying the nocturnal accumulation RTM, which improves interpretation of findings, we use measurements from a range of contrasting sites to discuss the significance of the technique's eight key considerations: (i) nocturnal window definition, (ii) radon and target gas accumulation thresholds, (iii) radon-to-target gas regression linearity thresholds, (iv) measurement height, (v) the contributing fetch, (vi) spatial and temporal radon flux variability, (vii) RTM temporal resolution, and (viii) application specific selection of a suitable radon monitor. The insight provided by these examples to the flexibility (or otherwise) of the technique's considerations will clarify the implications if users choose to relax or ignore them, potentially making future RTM studies more directly comparable.
- 29 October 2026
- Published by Copernicus GmbH in Atmospheric Measurement Techniques
- Vol. 19 (20) , 6823-6856
Open AccessReview of the Radon Tracer Method for GHG emission estimates: development, application guidelines, improvements, and caveats
The Radon Tracer Method (RTM) is an established, independent top-down method that can be used to cross-check bottom-up greenhouse gas (GHG) emission estimates. Furthermore, as uncertainties of Atmospheric Transport Models are reduced, the RTM can provide a convenient means of quantifying continual improvement of inversion-based top-down GHG emission estimates. While the accessibility and perceived simplicity of the RTM drive its popularity, the technique is better suited to assessing long-term relative changes in GHG emissions than absolute changes, due to short-term soil moisture influences on simulated radon flux uncertainty. Considerations for applying the RTM, based on fundamental assumptions of the technique's development, are application and season specific, making the development of a “standard protocol” for its use challenging. After proposing a novel alternative means of applying the nocturnal accumulation RTM, which improves interpretation of findings, we use measurements from a range of contrasting sites to discuss the significance of the technique's eight key considerations: (i) nocturnal window definition, (ii) radon and target gas accumulation thresholds, (iii) radon-to-target gas regression linearity thresholds, (iv) measurement height, (v) the contributing fetch, (vi) spatial and temporal radon flux variability, (vii) RTM temporal resolution, and (viii) application specific selection of a suitable radon monitor. The insight provided by these examples to the flexibility (or otherwise) of the technique's considerations will clarify the implications if users choose to relax or ignore them, potentially making future RTM studies more directly comparable.
- Open Access
- 14 September 2026
- Published by Copernicus GmbH
- Vol. 2025, 1-48
Reply on RC2
The Radon Tracer Method (RTM) is an established, independent top-down method that can be used to cross-check bottom-up greenhouse gas (GHG) emission estimates. Furthermore, as uncertainties of Atmospheric Transport Models are reduced, the RTM can provide a convenient means of quantifying continual improvement of inversion-based top-down GHG emission estimates. While the accessibility and perceived simplicity of the RTM drive its popularity, the technique is better suited to assessing long-term relative changes in GHG emissions than absolute changes, due to short-term soil moisture influences on simulated radon flux uncertainty. Considerations for applying the RTM, based on fundamental assumptions of the technique's development, are application and season specific, making the development of a "standard protocol" for its use challenging. After proposing a novel alternative means of applying the nocturnal accumulation RTM, which improves interpretation of findings, we use measurements from a range of contrasting sites to discuss the significance of the technique's eight key considerations: (i) nocturnal window definition, (ii) radon and target gas accumulation thresholds, (iii) radon-to-target gas regression linearity thresholds, (iv) measurement height, (v) the contributing fetch, (vi) spatial and temporal radon flux variability, (vii) RTM temporal resolution, and (viii) application specific selection of a suitable radon monitor. The insight provided by these examples to the flexibility (or otherwise) of the technique's considerations will clarify the implications if users choose to relax or ignore them, potentially making future RTM studies more directly comparable.
- 14 September 2026
- Published by Copernicus GmbH
- Vol. 2025, 1-48
Open AccessReply on RC2
The Radon Tracer Method (RTM) is an established, independent top-down method that can be used to cross-check bottom-up greenhouse gas (GHG) emission estimates. Furthermore, as uncertainties of Atmospheric Transport Models are reduced, the RTM can provide a convenient means of quantifying continual improvement of inversion-based top-down GHG emission estimates. While the accessibility and perceived simplicity of the RTM drive its popularity, the technique is better suited to assessing long-term relative changes in GHG emissions than absolute changes, due to short-term soil moisture influences on simulated radon flux uncertainty. Considerations for applying the RTM, based on fundamental assumptions of the technique's development, are application and season specific, making the development of a "standard protocol" for its use challenging. After proposing a novel alternative means of applying the nocturnal accumulation RTM, which improves interpretation of findings, we use measurements from a range of contrasting sites to discuss the significance of the technique's eight key considerations: (i) nocturnal window definition, (ii) radon and target gas accumulation thresholds, (iii) radon-to-target gas regression linearity thresholds, (iv) measurement height, (v) the contributing fetch, (vi) spatial and temporal radon flux variability, (vii) RTM temporal resolution, and (viii) application specific selection of a suitable radon monitor. The insight provided by these examples to the flexibility (or otherwise) of the technique's considerations will clarify the implications if users choose to relax or ignore them, potentially making future RTM studies more directly comparable.
- Open Access
- 27 August 2026
- Published by Copernicus GmbH
- Vol. 2025, 1-48
Comment on egusphere-2025-5042
The Radon Tracer Method (RTM) is an established, independent top-down method that can be used to cross-check bottom-up greenhouse gas (GHG) emission estimates. Furthermore, as uncertainties of Atmospheric Transport Models are reduced, the RTM can provide a convenient means of quantifying continual improvement of inversion-based top-down GHG emission estimates. While the accessibility and perceived simplicity of the RTM drive its popularity, the technique is better suited to assessing long-term relative changes in GHG emissions than absolute changes, due to short-term soil moisture influences on simulated radon flux uncertainty. Considerations for applying the RTM, based on fundamental assumptions of the technique's development, are application and season specific, making the development of a "standard protocol" for its use challenging. After proposing a novel alternative means of applying the nocturnal accumulation RTM, which improves interpretation of findings, we use measurements from a range of contrasting sites to discuss the significance of the technique's eight key considerations: (i) nocturnal window definition, (ii) radon and target gas accumulation thresholds, (iii) radon-to-target gas regression linearity thresholds, (iv) measurement height, (v) the contributing fetch, (vi) spatial and temporal radon flux variability, (vii) RTM temporal resolution, and (viii) application specific selection of a suitable radon monitor. The insight provided by these examples to the flexibility (or otherwise) of the technique's considerations will clarify the implications if users choose to relax or ignore them, potentially making future RTM studies more directly comparable.
- 27 August 2026
- Published by Copernicus GmbH
- Vol. 2025, 1-48
Open AccessComment on egusphere-2025-5042
The Radon Tracer Method (RTM) is an established, independent top-down method that can be used to cross-check bottom-up greenhouse gas (GHG) emission estimates. Furthermore, as uncertainties of Atmospheric Transport Models are reduced, the RTM can provide a convenient means of quantifying continual improvement of inversion-based top-down GHG emission estimates. While the accessibility and perceived simplicity of the RTM drive its popularity, the technique is better suited to assessing long-term relative changes in GHG emissions than absolute changes, due to short-term soil moisture influences on simulated radon flux uncertainty. Considerations for applying the RTM, based on fundamental assumptions of the technique's development, are application and season specific, making the development of a "standard protocol" for its use challenging. After proposing a novel alternative means of applying the nocturnal accumulation RTM, which improves interpretation of findings, we use measurements from a range of contrasting sites to discuss the significance of the technique's eight key considerations: (i) nocturnal window definition, (ii) radon and target gas accumulation thresholds, (iii) radon-to-target gas regression linearity thresholds, (iv) measurement height, (v) the contributing fetch, (vi) spatial and temporal radon flux variability, (vii) RTM temporal resolution, and (viii) application specific selection of a suitable radon monitor. The insight provided by these examples to the flexibility (or otherwise) of the technique's considerations will clarify the implications if users choose to relax or ignore them, potentially making future RTM studies more directly comparable.
- Open Access
- 13 August 2026
- Published by Copernicus GmbH in Atmospheric Chemistry and Physics
- Vol. 26 (15) , 11421-11448
Using high frequency observations of δ 13 C-CH 4 and δ 2 H-CH 4 and uncertain regional isotopic signatures to estimate sources of UK methane emissions
Methane is emitted from a range of anthropogenic and natural sources, and identifying these sources is important for emissions monitoring and mitigation. Different sources emit methane with different isotopic signatures. However, these signatures can vary spatially and temporally and are often not well understood. Top-down inverse methods can be used with measurements of methane mole fractions to estimate total emissions of methane from all sources. Here, we present an inverse system for concurrently estimating regional fossil-fuel (FF) and non-fossil-fuel (non-FF) emissions, using isotope ratio observations and considering uncertainty in the isotopic signatures. This method is highly adaptable and could be used to estimate emissions from any number of sources. Synthetic data tests with this method show that this inverse system can accurately estimate FF and non-FF methane emissions across the UK, when isotopic source signatures are fixed at known values. However, emissions estimation becomes less accurate when source signature uncertainties are increased to over approximately 50 % of their likely ranges. In a real-world test of this method, we estimated south-east UK FF and non-FF emissions using high-frequency δ 13 C-CH 4 and δ 2 H-CH 4 observations from one UK site, with source signature uncertainties reflecting our current understanding of these values. Results show only a limited impact on emissions uncertainty and magnitude, when compared with a methane-only inversion. This suggests that both an expansion of the UK network of isotope ratio observations and an improved understanding of isotopic signatures is required for this method to be effective in estimating UK FF and non-FF methane emissions with reduced uncertainty compared to traditional inverse methods.
- 13 August 2026
- Published by Copernicus GmbH in Atmospheric Chemistry and Physics
- Vol. 26 (15) , 11421-11448
Open AccessUsing high frequency observations of δ 13 C-CH 4 and δ 2 H-CH 4 and uncertain regional isotopic signatures to estimate sources of UK methane emissions
Methane is emitted from a range of anthropogenic and natural sources, and identifying these sources is important for emissions monitoring and mitigation. Different sources emit methane with different isotopic signatures. However, these signatures can vary spatially and temporally and are often not well understood. Top-down inverse methods can be used with measurements of methane mole fractions to estimate total emissions of methane from all sources. Here, we present an inverse system for concurrently estimating regional fossil-fuel (FF) and non-fossil-fuel (non-FF) emissions, using isotope ratio observations and considering uncertainty in the isotopic signatures. This method is highly adaptable and could be used to estimate emissions from any number of sources. Synthetic data tests with this method show that this inverse system can accurately estimate FF and non-FF methane emissions across the UK, when isotopic source signatures are fixed at known values. However, emissions estimation becomes less accurate when source signature uncertainties are increased to over approximately 50 % of their likely ranges. In a real-world test of this method, we estimated south-east UK FF and non-FF emissions using high-frequency δ 13 C-CH 4 and δ 2 H-CH 4 observations from one UK site, with source signature uncertainties reflecting our current understanding of these values. Results show only a limited impact on emissions uncertainty and magnitude, when compared with a methane-only inversion. This suggests that both an expansion of the UK network of isotope ratio observations and an improved understanding of isotopic signatures is required for this method to be effective in estimating UK FF and non-FF methane emissions with reduced uncertainty compared to traditional inverse methods.
- Open Access
- 17 July 2026
- Published by Copernicus GmbH
- p. 1-48
Reply on RC1
The Radon Tracer Method (RTM) is an established, independent top-down method that can be used to cross-check bottom-up greenhouse gas (GHG) emission estimates. Furthermore, as uncertainties of Atmospheric Transport Models are reduced, the RTM can provide a convenient means of quantifying continual improvement of inversion-based top-down GHG emission estimates. While the accessibility and perceived simplicity of the RTM drive its popularity, the technique is better suited to assessing long-term relative changes in GHG emissions than absolute changes, due to short-term soil moisture influences on simulated radon flux uncertainty. Considerations for applying the RTM, based on fundamental assumptions of the technique's development, are application and season specific, making the development of a "standard protocol" for its use challenging. After proposing a novel alternative means of applying the nocturnal accumulation RTM, which improves interpretation of findings, we use measurements from a range of contrasting sites to discuss the significance of the technique's eight key considerations: (i) nocturnal window definition, (ii) radon and target gas accumulation thresholds, (iii) radon-to-target gas regression linearity thresholds, (iv) measurement height, (v) the contributing fetch, (vi) spatial and temporal radon flux variability, (vii) RTM temporal resolution, and (viii) application specific selection of a suitable radon monitor. The insight provided by these examples to the flexibility (or otherwise) of the technique's considerations will clarify the implications if users choose to relax or ignore them, potentially making future RTM studies more directly comparable.
- 17 July 2026
- Published by Copernicus GmbH
- p. 1-48
Open AccessReply on RC1
The Radon Tracer Method (RTM) is an established, independent top-down method that can be used to cross-check bottom-up greenhouse gas (GHG) emission estimates. Furthermore, as uncertainties of Atmospheric Transport Models are reduced, the RTM can provide a convenient means of quantifying continual improvement of inversion-based top-down GHG emission estimates. While the accessibility and perceived simplicity of the RTM drive its popularity, the technique is better suited to assessing long-term relative changes in GHG emissions than absolute changes, due to short-term soil moisture influences on simulated radon flux uncertainty. Considerations for applying the RTM, based on fundamental assumptions of the technique's development, are application and season specific, making the development of a "standard protocol" for its use challenging. After proposing a novel alternative means of applying the nocturnal accumulation RTM, which improves interpretation of findings, we use measurements from a range of contrasting sites to discuss the significance of the technique's eight key considerations: (i) nocturnal window definition, (ii) radon and target gas accumulation thresholds, (iii) radon-to-target gas regression linearity thresholds, (iv) measurement height, (v) the contributing fetch, (vi) spatial and temporal radon flux variability, (vii) RTM temporal resolution, and (viii) application specific selection of a suitable radon monitor. The insight provided by these examples to the flexibility (or otherwise) of the technique's considerations will clarify the implications if users choose to relax or ignore them, potentially making future RTM studies more directly comparable.
- Open Access
- 17 June 2026
- Published by Copernicus GmbH
- Vol. 2025, 1-48
Comment on egusphere-2025-5042
The Radon Tracer Method (RTM) is an established, independent top-down method that can be used to cross-check bottom-up greenhouse gas (GHG) emission estimates. Furthermore, as uncertainties of Atmospheric Transport Models are reduced, the RTM can provide a convenient means of quantifying continual improvement of inversion-based top-down GHG emission estimates. While the accessibility and perceived simplicity of the RTM drive its popularity, the technique is better suited to assessing long-term relative changes in GHG emissions than absolute changes, due to short-term soil moisture influences on simulated radon flux uncertainty. Considerations for applying the RTM, based on fundamental assumptions of the technique's development, are application and season specific, making the development of a "standard protocol" for its use challenging. After proposing a novel alternative means of applying the nocturnal accumulation RTM, which improves interpretation of findings, we use measurements from a range of contrasting sites to discuss the significance of the technique's eight key considerations: (i) nocturnal window definition, (ii) radon and target gas accumulation thresholds, (iii) radon-to-target gas regression linearity thresholds, (iv) measurement height, (v) the contributing fetch, (vi) spatial and temporal radon flux variability, (vii) RTM temporal resolution, and (viii) application specific selection of a suitable radon monitor. The insight provided by these examples to the flexibility (or otherwise) of the technique's considerations will clarify the implications if users choose to relax or ignore them, potentially making future RTM studies more directly comparable.
- 17 June 2026
- Published by Copernicus GmbH
- Vol. 2025, 1-48
Open AccessComment on egusphere-2025-5042
The Radon Tracer Method (RTM) is an established, independent top-down method that can be used to cross-check bottom-up greenhouse gas (GHG) emission estimates. Furthermore, as uncertainties of Atmospheric Transport Models are reduced, the RTM can provide a convenient means of quantifying continual improvement of inversion-based top-down GHG emission estimates. While the accessibility and perceived simplicity of the RTM drive its popularity, the technique is better suited to assessing long-term relative changes in GHG emissions than absolute changes, due to short-term soil moisture influences on simulated radon flux uncertainty. Considerations for applying the RTM, based on fundamental assumptions of the technique's development, are application and season specific, making the development of a "standard protocol" for its use challenging. After proposing a novel alternative means of applying the nocturnal accumulation RTM, which improves interpretation of findings, we use measurements from a range of contrasting sites to discuss the significance of the technique's eight key considerations: (i) nocturnal window definition, (ii) radon and target gas accumulation thresholds, (iii) radon-to-target gas regression linearity thresholds, (iv) measurement height, (v) the contributing fetch, (vi) spatial and temporal radon flux variability, (vii) RTM temporal resolution, and (viii) application specific selection of a suitable radon monitor. The insight provided by these examples to the flexibility (or otherwise) of the technique's considerations will clarify the implications if users choose to relax or ignore them, potentially making future RTM studies more directly comparable.
- Open Access
- 1 June 2026
- Published by Copernicus GmbH in Atmospheric Chemistry and Physics
- Vol. 26 (10) , 7647-7675
European HFC emissions evaluated with multiple atmospheric inverse models and UNFCCC national inventories
Hydrofluorocarbons (HFCs) are potent greenhouse gases widely used in refrigeration, air-conditioning, and heat pump systems. Accurate monitoring of HFC emissions is essential to evaluate compliance with climate regulations and inform mitigation strategies. This study presents trends of HFC emissions across north-western Europe between 2013 and 2024, derived from atmospheric inverse modelling combining atmospheric measurements at eleven monitoring stations with two transport models (NAME and FLEXPART) and three Bayesian inversion systems (InTEM, ELRIS, RHIME). Although global emissions continue to rise for most HFCs, in north-western Europe our results show an overall steady decline in total HFC emissions from 40 ± 3 Tg CO 2 -eq yr −1 in 2016 (prior to enhanced regulation) to 29 ± 2 Tg CO 2 -eq yr −1 in 2023, following EU F-gas Regulations. This reduction is driven primarily by decreasing emissions of HFC-134a, HFC-143a and HFC-125 despite increasing HFC-32 emissions due to its adoption as a lower-global-warming-potential alternative refrigerant. Comparisons with national inventories reported to the United Nations Framework Convention on Climate Change (UNFCCC) show generally good agreement over north-western Europe but reveal discrepancies for specific compounds and countries, particularly for HFC-134a and HFC-125 in France and Germany during the earlier years of the study period. The recent expansion of the European measurement network demonstrates potential to improve spatial coverage and resolution of inverse emission estimates, especially in southern and central Europe. This study highlights the value of multi-model inversions to provide robust emission estimates with realistic, hence actionable, uncertainty characterisation.
- 1 June 2026
- Published by Copernicus GmbH in Atmospheric Chemistry and Physics
- Vol. 26 (10) , 7647-7675
Open AccessEuropean HFC emissions evaluated with multiple atmospheric inverse models and UNFCCC national inventories
Hydrofluorocarbons (HFCs) are potent greenhouse gases widely used in refrigeration, air-conditioning, and heat pump systems. Accurate monitoring of HFC emissions is essential to evaluate compliance with climate regulations and inform mitigation strategies. This study presents trends of HFC emissions across north-western Europe between 2013 and 2024, derived from atmospheric inverse modelling combining atmospheric measurements at eleven monitoring stations with two transport models (NAME and FLEXPART) and three Bayesian inversion systems (InTEM, ELRIS, RHIME). Although global emissions continue to rise for most HFCs, in north-western Europe our results show an overall steady decline in total HFC emissions from 40 ± 3 Tg CO 2 -eq yr −1 in 2016 (prior to enhanced regulation) to 29 ± 2 Tg CO 2 -eq yr −1 in 2023, following EU F-gas Regulations. This reduction is driven primarily by decreasing emissions of HFC-134a, HFC-143a and HFC-125 despite increasing HFC-32 emissions due to its adoption as a lower-global-warming-potential alternative refrigerant. Comparisons with national inventories reported to the United Nations Framework Convention on Climate Change (UNFCCC) show generally good agreement over north-western Europe but reveal discrepancies for specific compounds and countries, particularly for HFC-134a and HFC-125 in France and Germany during the earlier years of the study period. The recent expansion of the European measurement network demonstrates potential to improve spatial coverage and resolution of inverse emission estimates, especially in southern and central Europe. This study highlights the value of multi-model inversions to provide robust emission estimates with realistic, hence actionable, uncertainty characterisation.
- Open Access
- 22 May 2026
- Published by Copernicus GmbH in Atmospheric Chemistry and Physics
- Vol. 26 (10) , 6993-7012
Global Observations and European emissions of the halogenated olefins HFO-1234yf, HFO-1234ze(E), and HCFO-1233zd(E) from the AGAGE (Advanced Global Atmospheric Gases Experiment) network
Hydrofluoroolefins (HFOs) are important synthetic compounds replacing other halocarbons in phase-down from usage (e.g., as refrigerants, propellants, foam blowing). Little is known about their atmospheric abundance, distribution and trends, nor about their emissons. Here, we report atmospheric observations of the widely used HFO-1234yf (2,3,3,3-tetrafluoroprop-1-ene), and HFO-1234ze(E) (E-1,3,3,3-tetrafluoroprop-1-ene), and the hydrochlorofluoroolefin (HCFO) HCFO-1233zd(E) (E-1-chloro-3,3,3-trifluoroprop-1-ene) observed as part of the Advanced Global Atmospheric Gases Experiment (AGAGE) network. Over the observational period 2011–2025, pollution events have grown in magnitude and frequency at sites which are influenced by regional emissions, while remote stations show first appearances of these substances. By 2024/2025 winter peak mole fractions in background northern hemisphere air have reached ∼ 0.25 ppt (picomol mol −1 , parts-per-trillion in dry air) for HFO-1234yf and HFO-1234ze(E) and ∼ 0.45 ppt for HCFO-1233zd(E). Using European observations and the inverse modeling frameworks InTEM, ELRIS, and RHIME we determine emission trends and regional distributions. For Northwest Europe, emissions of HFO-1234yf increased steadily and rapidly from −1 in 2014 to 1.50 [1.23–1.74, range of 16–84 percentile] Gg yr −1 by 2023, presumably due to its introduction in mobile air conditioning and stationary refrigeration. HFO-1234ze(E) emissions were low during 2014–2017, followed by a rapid increase in 2018/2019, potentially due its introduction as an aerosol propellant, after which they increased more slowly to 0.96 [0.82–1.13] Gg yr −1 by 2023. HCFO-1233zd(E) emissions are derived from 2017 onward, showing a steady increase from 0.15 [0.07–0.23] to 1.04 [0.93–1.15] Gg yr −1 in 2023.
- 22 May 2026
- Published by Copernicus GmbH in Atmospheric Chemistry and Physics
- Vol. 26 (10) , 6993-7012
Open AccessGlobal Observations and European emissions of the halogenated olefins HFO-1234yf, HFO-1234ze(E), and HCFO-1233zd(E) from the AGAGE (Advanced Global Atmospheric Gases Experiment) network
Hydrofluoroolefins (HFOs) are important synthetic compounds replacing other halocarbons in phase-down from usage (e.g., as refrigerants, propellants, foam blowing). Little is known about their atmospheric abundance, distribution and trends, nor about their emissons. Here, we report atmospheric observations of the widely used HFO-1234yf (2,3,3,3-tetrafluoroprop-1-ene), and HFO-1234ze(E) (E-1,3,3,3-tetrafluoroprop-1-ene), and the hydrochlorofluoroolefin (HCFO) HCFO-1233zd(E) (E-1-chloro-3,3,3-trifluoroprop-1-ene) observed as part of the Advanced Global Atmospheric Gases Experiment (AGAGE) network. Over the observational period 2011–2025, pollution events have grown in magnitude and frequency at sites which are influenced by regional emissions, while remote stations show first appearances of these substances. By 2024/2025 winter peak mole fractions in background northern hemisphere air have reached ∼ 0.25 ppt (picomol mol −1 , parts-per-trillion in dry air) for HFO-1234yf and HFO-1234ze(E) and ∼ 0.45 ppt for HCFO-1233zd(E). Using European observations and the inverse modeling frameworks InTEM, ELRIS, and RHIME we determine emission trends and regional distributions. For Northwest Europe, emissions of HFO-1234yf increased steadily and rapidly from −1 in 2014 to 1.50 [1.23–1.74, range of 16–84 percentile] Gg yr −1 by 2023, presumably due to its introduction in mobile air conditioning and stationary refrigeration. HFO-1234ze(E) emissions were low during 2014–2017, followed by a rapid increase in 2018/2019, potentially due its introduction as an aerosol propellant, after which they increased more slowly to 0.96 [0.82–1.13] Gg yr −1 by 2023. HCFO-1233zd(E) emissions are derived from 2017 onward, showing a steady increase from 0.15 [0.07–0.23] to 1.04 [0.93–1.15] Gg yr −1 in 2023.
- Open Access
- 7 April 2026
- Published by Copernicus GmbH
- Vol. 2026, 1-40
Comment on egusphere-2026-779
Methane is emitted from a range of anthropogenic and natural sources, and identifying these sources is important for emissions monitoring and mitigation. Different sources emit methane with different isotopic signatures; however these signatures are often uncertain or vary spatially or temporally. Top-down inverse models can be used with measurement of methane mole fractions to estimate total emissions of methane from all sources. We present an inverse model for estimating regional fossil-fuel (FF) and non-fossil-fuel (non-FF) emissions concurrently, using isotope ratio observations and uncertain isotopic signatures. This method is highly adaptable and could be used to estimate emissions from any number of sources. Synthetic data tests with this method show that this model can accurately estimate FF and non-FF methane emissions across the UK, when isotopic source signatures are fixed at known values. However, emissions estimation becomes less accurate when source signature uncertainties rise above approximately 50 % of their likely ranges. In a real-world test of this method, we estimated south-east UK FF and non-FF emissions using high-frequency δ13C-CH4 and δ2H-CH4 observations from one UK site, with source signature uncertainties reflecting our current understanding of these values. Results show a limited impact on emissions uncertainty or magnitude, when compared with output from an inversion using only mole fraction observations. This suggests that both the ongoing expansion of isotope ratio observations and an improved understanding of isotopic signatures is required for this method to be used to estimate UK FF and non-FF methane emissions, with reduced uncertainty compared to traditional inverse methods.
- 7 April 2026
- Published by Copernicus GmbH
- Vol. 2026, 1-40
Open AccessComment on egusphere-2026-779
Methane is emitted from a range of anthropogenic and natural sources, and identifying these sources is important for emissions monitoring and mitigation. Different sources emit methane with different isotopic signatures; however these signatures are often uncertain or vary spatially or temporally. Top-down inverse models can be used with measurement of methane mole fractions to estimate total emissions of methane from all sources. We present an inverse model for estimating regional fossil-fuel (FF) and non-fossil-fuel (non-FF) emissions concurrently, using isotope ratio observations and uncertain isotopic signatures. This method is highly adaptable and could be used to estimate emissions from any number of sources. Synthetic data tests with this method show that this model can accurately estimate FF and non-FF methane emissions across the UK, when isotopic source signatures are fixed at known values. However, emissions estimation becomes less accurate when source signature uncertainties rise above approximately 50 % of their likely ranges. In a real-world test of this method, we estimated south-east UK FF and non-FF emissions using high-frequency δ13C-CH4 and δ2H-CH4 observations from one UK site, with source signature uncertainties reflecting our current understanding of these values. Results show a limited impact on emissions uncertainty or magnitude, when compared with output from an inversion using only mole fraction observations. This suggests that both the ongoing expansion of isotope ratio observations and an improved understanding of isotopic signatures is required for this method to be used to estimate UK FF and non-FF methane emissions, with reduced uncertainty compared to traditional inverse methods.
- Open Access
- 3 April 2026
- Published by Copernicus GmbH
- Vol. 2026, 1-40
Comment on egusphere-2026-779
Methane is emitted from a range of anthropogenic and natural sources, and identifying these sources is important for emissions monitoring and mitigation. Different sources emit methane with different isotopic signatures; however these signatures are often uncertain or vary spatially or temporally. Top-down inverse models can be used with measurement of methane mole fractions to estimate total emissions of methane from all sources. We present an inverse model for estimating regional fossil-fuel (FF) and non-fossil-fuel (non-FF) emissions concurrently, using isotope ratio observations and uncertain isotopic signatures. This method is highly adaptable and could be used to estimate emissions from any number of sources. Synthetic data tests with this method show that this model can accurately estimate FF and non-FF methane emissions across the UK, when isotopic source signatures are fixed at known values. However, emissions estimation becomes less accurate when source signature uncertainties rise above approximately 50 % of their likely ranges. In a real-world test of this method, we estimated south-east UK FF and non-FF emissions using high-frequency δ13C-CH4 and δ2H-CH4 observations from one UK site, with source signature uncertainties reflecting our current understanding of these values. Results show a limited impact on emissions uncertainty or magnitude, when compared with output from an inversion using only mole fraction observations. This suggests that both the ongoing expansion of isotope ratio observations and an improved understanding of isotopic signatures is required for this method to be used to estimate UK FF and non-FF methane emissions, with reduced uncertainty compared to traditional inverse methods.
- 3 April 2026
- Published by Copernicus GmbH
- Vol. 2026, 1-40
Open AccessComment on egusphere-2026-779
Methane is emitted from a range of anthropogenic and natural sources, and identifying these sources is important for emissions monitoring and mitigation. Different sources emit methane with different isotopic signatures; however these signatures are often uncertain or vary spatially or temporally. Top-down inverse models can be used with measurement of methane mole fractions to estimate total emissions of methane from all sources. We present an inverse model for estimating regional fossil-fuel (FF) and non-fossil-fuel (non-FF) emissions concurrently, using isotope ratio observations and uncertain isotopic signatures. This method is highly adaptable and could be used to estimate emissions from any number of sources. Synthetic data tests with this method show that this model can accurately estimate FF and non-FF methane emissions across the UK, when isotopic source signatures are fixed at known values. However, emissions estimation becomes less accurate when source signature uncertainties rise above approximately 50 % of their likely ranges. In a real-world test of this method, we estimated south-east UK FF and non-FF emissions using high-frequency δ13C-CH4 and δ2H-CH4 observations from one UK site, with source signature uncertainties reflecting our current understanding of these values. Results show a limited impact on emissions uncertainty or magnitude, when compared with output from an inversion using only mole fraction observations. This suggests that both the ongoing expansion of isotope ratio observations and an improved understanding of isotopic signatures is required for this method to be used to estimate UK FF and non-FF methane emissions, with reduced uncertainty compared to traditional inverse methods.