Collin J. McKinney
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Collin J. McKinney has a total of 118 co-authors. Here are the top co-authors by number of shared publications:
- Robert Mark Wightman
University of North Carolina at Chapel Hill
3 shared publications Y. Fares
Botany Department Phytotron, Duke University, Durham, North Carolina 27706
3 shared publicationsBrynn Brusseau
Department of Biology, University of North Carolina, Chapel Hill, USA
2 shared publicationsC. E. Magnuson
Botany Department Phytotron, Duke University, Durham, North Carolina 27706
2 shared publicationsChuqi Huang
Department of Applied Physical Sciences, University of North Carolina, Chapel Hill, USA
2 shared publications- Cory Allen Rusinek
Radiochemistry Program University of Nevada, Las Vegas Las Vegas Nevada USA
2 shared publications
Latest Publications
- Open Access
- 10 November 2026
- Published by Elsevier in Biosensors and Bioelectronics
Thin Film Conductors for Single-Molecule, Label-free Detection using Resistive Pulse Sensing
- 10 November 2026
- Published by Elsevier in Biosensors and Bioelectronics
Open AccessThin Film Conductors for Single-Molecule, Label-free Detection using Resistive Pulse Sensing
- Open Access
- 18 July 2026
- Published by Elsevier in SSRN Electronic Journal
Thin Film Conductors for Single-Molecule, Label-free Detection using Resistive Pulse Sensing
Resistive Pulse Sensing (RPS) provides label-free detection of single molecules. However, conventional RPS systems that rely on macroscopic wire electrodes suffer from mechanical instability and positional drift, which can contribute to large amounts of low-frequency noise. Integrating thin-film electrodes into RPS devices can address these issues, especially when coupled to devices that use thermoplastic substrates due to their ability to be fabricated in a high production mode. However, thin metal films patterned on polymer surfaces are limited by polymer surface energy mismatches and thermal deformation during metallization and bonding. Here, we present a monolithic integration approach for patterning thin film Ag/AgCl electrodes to a hybrid cyclic olefin polymer/copolymer (COP/COC) fluidic nanosensor. Robust interfacial adhesion was achieved utilizing Oâ plasma pretreatment of the plastic and a Titanium (Ti) adhesion layer followed by pulsed DC magnetron sputtering. A thermal fusion bonding protocol mitigated electrode step-height standoff, ensuring efficient sealing without compromising the integrity of the sub-100 nm features patterned via replication into the plastic substrate. Electrochemical characterization confirmed stable, non-polarizable operation for >3 h, while power spectral density analysis demonstrated reduced 1/f noise compared to wire electrodes. During the translocation of a 1200 nt DNA through in-plane nanopores (diameter ~10 nm), the integrated device delivered a 3.3-fold enhancement in the Signal-to-Noise Ratio compared to macro-scale wire electrodes. This performance was driven by a suppressed RMS noise floor and a 2.9-fold increase in fractional blockade amplitude. This work establishes a scalable, high-yield fabrication framework for robust, high-sensitivity solid-state nanopore sensing platforms.
- 18 July 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessThin Film Conductors for Single-Molecule, Label-free Detection using Resistive Pulse Sensing
Resistive Pulse Sensing (RPS) provides label-free detection of single molecules. However, conventional RPS systems that rely on macroscopic wire electrodes suffer from mechanical instability and positional drift, which can contribute to large amounts of low-frequency noise. Integrating thin-film electrodes into RPS devices can address these issues, especially when coupled to devices that use thermoplastic substrates due to their ability to be fabricated in a high production mode. However, thin metal films patterned on polymer surfaces are limited by polymer surface energy mismatches and thermal deformation during metallization and bonding. Here, we present a monolithic integration approach for patterning thin film Ag/AgCl electrodes to a hybrid cyclic olefin polymer/copolymer (COP/COC) fluidic nanosensor. Robust interfacial adhesion was achieved utilizing Oâ plasma pretreatment of the plastic and a Titanium (Ti) adhesion layer followed by pulsed DC magnetron sputtering. A thermal fusion bonding protocol mitigated electrode step-height standoff, ensuring efficient sealing without compromising the integrity of the sub-100 nm features patterned via replication into the plastic substrate. Electrochemical characterization confirmed stable, non-polarizable operation for >3 h, while power spectral density analysis demonstrated reduced 1/f noise compared to wire electrodes. During the translocation of a 1200 nt DNA through in-plane nanopores (diameter ~10 nm), the integrated device delivered a 3.3-fold enhancement in the Signal-to-Noise Ratio compared to macro-scale wire electrodes. This performance was driven by a suppressed RMS noise floor and a 2.9-fold increase in fractional blockade amplitude. This work establishes a scalable, high-yield fabrication framework for robust, high-sensitivity solid-state nanopore sensing platforms.
- Top Cited PapersOpen Access
- 5 June 2024
- Published by Springer Nature in Nature Communications
- Vol. 15  (1) , 1-20
Skin-inspired, sensory robots for electronic implants
Drawing inspiration from cohesive integration of skeletal muscles and sensory skins in vertebrate animals, we present a design strategy of soft robots, primarily consisting of an electronic skin (e-skin) and an artificial muscle. These robots integrate multifunctional sensing and on-demand actuation into a biocompatible platform using an in-situ solution-based method. They feature biomimetic designs that enable adaptive motions and stress-free contact with tissues, supported by a battery-free wireless module for untethered operation. Demonstrations range from a robotic cuff for detecting blood pressure, to a robotic gripper for tracking bladder volume, an ingestible robot for pH sensing and on-site drug delivery, and a robotic patch for quantifying cardiac function and delivering electrotherapy, highlighting the application versatilities and potentials of the bio-inspired soft robots. Our designs establish a universal strategy with a broad range of sensing and responsive materials, to form integrated soft robots for medical technology and beyond.
- 5 June 2024
- Published by Springer Nature in Nature Communications
- Vol. 15  (1) , 1-20
Top Cited PapersOpen AccessSkin-inspired, sensory robots for electronic implants
Drawing inspiration from cohesive integration of skeletal muscles and sensory skins in vertebrate animals, we present a design strategy of soft robots, primarily consisting of an electronic skin (e-skin) and an artificial muscle. These robots integrate multifunctional sensing and on-demand actuation into a biocompatible platform using an in-situ solution-based method. They feature biomimetic designs that enable adaptive motions and stress-free contact with tissues, supported by a battery-free wireless module for untethered operation. Demonstrations range from a robotic cuff for detecting blood pressure, to a robotic gripper for tracking bladder volume, an ingestible robot for pH sensing and on-site drug delivery, and a robotic patch for quantifying cardiac function and delivering electrotherapy, highlighting the application versatilities and potentials of the bio-inspired soft robots. Our designs establish a universal strategy with a broad range of sensing and responsive materials, to form integrated soft robots for medical technology and beyond.
- Open Access
- 22 December 2023
- Published by Springer Nature in Research Square
Skin-inspired, sensory robots for electronic implants
Living organisms with motor and sensor units integrated seamlessly demonstrate effective adaptation to dynamically changing environments. Drawing inspiration from cohesive integration of skeletal muscles and sensory skins in these organisms, we present a design strategy of soft robots, primarily consisting of an electronic skin (e-skin) and an artificial muscle, that naturally couples multifunctional sensing and on-demand actuation in a biocompatible platform. We introduce an in situ solution-based method to create an e-skin layer with diverse sensing materials (e.g., silver nanowires, reduced graphene oxide, MXene, and conductive polymers) incorporated within a polymer matrix (e.g., polyimide), imitating complex skin receptors to perceive various stimuli. Biomimicry designs (e.g., starfish and chiral seedpods) of the robots enable various motions (e.g., bending, expanding, and twisting) on demand and realize good fixation and stress-free contact with tissues. Furthermore, integration of a battery-free wireless module into these robots enables operation and communication without tethering, thus enhancing the safety and biocompatibility as minimally invasive implants. Demonstrations range from a robotic cuff encircling a blood vessel for detecting blood pressure, to a robotic gripper holding onto a bladder for tracking bladder volume, an ingestible robot residing inside stomach for pH sensing and on-site drug delivery, and a robotic patch wrapping onto a beating heart for quantifying cardiac contractility, temperature and applying cardiac pacing, highlighting the application versatilities and potentials of the nature-inspired soft robots. Our designs establish a universal strategy with a broad range of sensing and responsive materials, to form integrated soft robots for medical technology and beyond.
- 22 December 2023
- Published by Springer Nature in Research Square
Open AccessSkin-inspired, sensory robots for electronic implants
Living organisms with motor and sensor units integrated seamlessly demonstrate effective adaptation to dynamically changing environments. Drawing inspiration from cohesive integration of skeletal muscles and sensory skins in these organisms, we present a design strategy of soft robots, primarily consisting of an electronic skin (e-skin) and an artificial muscle, that naturally couples multifunctional sensing and on-demand actuation in a biocompatible platform. We introduce an in situ solution-based method to create an e-skin layer with diverse sensing materials (e.g., silver nanowires, reduced graphene oxide, MXene, and conductive polymers) incorporated within a polymer matrix (e.g., polyimide), imitating complex skin receptors to perceive various stimuli. Biomimicry designs (e.g., starfish and chiral seedpods) of the robots enable various motions (e.g., bending, expanding, and twisting) on demand and realize good fixation and stress-free contact with tissues. Furthermore, integration of a battery-free wireless module into these robots enables operation and communication without tethering, thus enhancing the safety and biocompatibility as minimally invasive implants. Demonstrations range from a robotic cuff encircling a blood vessel for detecting blood pressure, to a robotic gripper holding onto a bladder for tracking bladder volume, an ingestible robot residing inside stomach for pH sensing and on-site drug delivery, and a robotic patch wrapping onto a beating heart for quantifying cardiac contractility, temperature and applying cardiac pacing, highlighting the application versatilities and potentials of the nature-inspired soft robots. Our designs establish a universal strategy with a broad range of sensing and responsive materials, to form integrated soft robots for medical technology and beyond.
- Open Access
- 19 June 2023
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 95  (26) , 9892-9900
High Sensitivity Extended Nano-Coulter Counter for Detection of Viral Particles and Extracellular Vesicles
We present a chip-based extended nano-Coulter counter (XnCC) that can detect nanoparticles affinity-selected from biological samples with low concentration limit-of-detection that surpasses existing resistive pulse sensors by 2-3 orders of magnitude. The XnCC was engineered to contain 5 in-plane pores each with an effective diameter of 350 nm placed in parallel and can provide high detection efficiency for single particles translocating both hydrodynamically and electrokinetically through these pores. The XnCC was fabricated in cyclic olefin polymer (COP) via nanoinjection molding to allow for high-scale production. The concentration limit-of-detection of the XnCC was 5.5 Ă 103 particles/mL, which was a 1,100-fold improvement compared to a single in-plane pore device. The application examples of the XnCC included counting affinity selected SARS-CoV-2 viral particles from saliva samples using an aptamer and pillared microchip; the selection/XnCC assay could distinguish the COVID-19(+) saliva samples from those that were COVID-19(-). In the second example, ovarian cancer extracellular vesicles (EVs) were affinity selected using a pillared chip modified with a MUC16 monoclonal antibody. The affinity selection chip coupled with the XnCC was successful in discriminating between patients with high grade serous ovarian cancer and healthy donors using blood plasma as the input sample.
- 19 June 2023
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 95  (26) , 9892-9900
Open AccessHigh Sensitivity Extended Nano-Coulter Counter for Detection of Viral Particles and Extracellular Vesicles
We present a chip-based extended nano-Coulter counter (XnCC) that can detect nanoparticles affinity-selected from biological samples with low concentration limit-of-detection that surpasses existing resistive pulse sensors by 2-3 orders of magnitude. The XnCC was engineered to contain 5 in-plane pores each with an effective diameter of 350 nm placed in parallel and can provide high detection efficiency for single particles translocating both hydrodynamically and electrokinetically through these pores. The XnCC was fabricated in cyclic olefin polymer (COP) via nanoinjection molding to allow for high-scale production. The concentration limit-of-detection of the XnCC was 5.5 Ă 103 particles/mL, which was a 1,100-fold improvement compared to a single in-plane pore device. The application examples of the XnCC included counting affinity selected SARS-CoV-2 viral particles from saliva samples using an aptamer and pillared microchip; the selection/XnCC assay could distinguish the COVID-19(+) saliva samples from those that were COVID-19(-). In the second example, ovarian cancer extracellular vesicles (EVs) were affinity selected using a pillared chip modified with a MUC16 monoclonal antibody. The affinity selection chip coupled with the XnCC was successful in discriminating between patients with high grade serous ovarian cancer and healthy donors using blood plasma as the input sample.
- 14 July 2021
- Published by American Chemical Society (ACS) in ACS Photonics
- Vol. 8  (8) , 2329-2336
Lithographically Patterning Hybrid Perovskite Single Crystals by Surface-Engineered Amino-Deliquescence/Efflorescence
- 14 July 2021
- Published by American Chemical Society (ACS) in ACS Photonics
- Vol. 8  (8) , 2329-2336
Lithographically Patterning Hybrid Perovskite Single Crystals by Surface-Engineered Amino-Deliquescence/Efflorescence
- Open Access
- 26 January 2021
- Published by MDPI AG in Micromachines
- Vol. 12  (2) , 128
Next-Generation Diamond Electrodes for Neurochemical Sensing: Challenges and Opportunities
Carbon-based electrodes combined with fast-scan cyclic voltammetry (FSCV) enable neurochemical sensing with high spatiotemporal resolution and sensitivity. While their attractive electrochemical and conductive properties have established a long history of use in the detection of neurotransmitters both in vitro and in vivo, carbon fiber microelectrodes (CFMEs) also have limitations in their fabrication, flexibility, and chronic stability. Diamond is a form of carbon with a more rigid bonding structure (sp3-hybridized) which can become conductive when boron-doped. Boron-doped diamond (BDD) is characterized by an extremely wide potential window, low background current, and good biocompatibility. Additionally, methods for processing and patterning diamond allow for high-throughput batch fabrication and customization of electrode arrays with unique architectures. While tradeoffs in sensitivity can undermine the advantages of BDD as a neurochemical sensor, there are numerous untapped opportunities to further improve performance, including anodic pretreatment, or optimization of the FSCV waveform, instrumentation, sp2/sp3 character, doping, surface characteristics, and signal processing. Here, we review the state-of-the-art in diamond electrodes for neurochemical sensing and discuss potential opportunities for future advancements of the technology. We highlight our teamâs progress with the development of an all-diamond fiber ultramicroelectrode as a novel approach to advance the performance and applications of diamond-based neurochemical sensors.
- 26 January 2021
- Published by MDPI AG in Micromachines
- Vol. 12  (2) , 128
Open AccessNext-Generation Diamond Electrodes for Neurochemical Sensing: Challenges and Opportunities
Carbon-based electrodes combined with fast-scan cyclic voltammetry (FSCV) enable neurochemical sensing with high spatiotemporal resolution and sensitivity. While their attractive electrochemical and conductive properties have established a long history of use in the detection of neurotransmitters both in vitro and in vivo, carbon fiber microelectrodes (CFMEs) also have limitations in their fabrication, flexibility, and chronic stability. Diamond is a form of carbon with a more rigid bonding structure (sp3-hybridized) which can become conductive when boron-doped. Boron-doped diamond (BDD) is characterized by an extremely wide potential window, low background current, and good biocompatibility. Additionally, methods for processing and patterning diamond allow for high-throughput batch fabrication and customization of electrode arrays with unique architectures. While tradeoffs in sensitivity can undermine the advantages of BDD as a neurochemical sensor, there are numerous untapped opportunities to further improve performance, including anodic pretreatment, or optimization of the FSCV waveform, instrumentation, sp2/sp3 character, doping, surface characteristics, and signal processing. Here, we review the state-of-the-art in diamond electrodes for neurochemical sensing and discuss potential opportunities for future advancements of the technology. We highlight our teamâs progress with the development of an all-diamond fiber ultramicroelectrode as a novel approach to advance the performance and applications of diamond-based neurochemical sensors.
- 10 April 2020
- Published by American Association for the Advancement of Science (AAAS) in Science
- Vol. 368  (6487) , 177-180
Ratcheting quasi-ballistic electrons in silicon geometric diodes at room temperature
Room-temperature electron ratchets: Conventional diodes rectify current flow by forming a junction between dissimilar conductors; a metal-semiconductor diode that forms a Schottky barrier is one example. In these devices, capacitance limits operating frequency. Custer et al. describe a diode made entirely of silicon that can rectify currents up to 40 gigahertz at room temperature. They fabricated silicon nanowires with a cylindrical sawtooth profile that act as ratchets, funneling current preferentially in one direction through specular reflection of quasi-ballistic electrons. Science , this issue p. 177
- 10 April 2020
- Published by American Association for the Advancement of Science (AAAS) in Science
- Vol. 368  (6487) , 177-180
Ratcheting quasi-ballistic electrons in silicon geometric diodes at room temperature
Room-temperature electron ratchets: Conventional diodes rectify current flow by forming a junction between dissimilar conductors; a metal-semiconductor diode that forms a Schottky barrier is one example. In these devices, capacitance limits operating frequency. Custer et al. describe a diode made entirely of silicon that can rectify currents up to 40 gigahertz at room temperature. They fabricated silicon nanowires with a cylindrical sawtooth profile that act as ratchets, funneling current preferentially in one direction through specular reflection of quasi-ballistic electrons. Science , this issue p. 177
- 25 November 2019
- Published by American Chemical Society (ACS) in Journal of Chemical Education
- Vol. 97  (1) , 265-270
SweepStat: A Build-It-Yourself, Two-Electrode Potentiostat for Macroelectrode and Ultramicroelectrode Studies
- 25 November 2019
- Published by American Chemical Society (ACS) in Journal of Chemical Education
- Vol. 97  (1) , 265-270
SweepStat: A Build-It-Yourself, Two-Electrode Potentiostat for Macroelectrode and Ultramicroelectrode Studies
- Open Access
- 31 July 2018
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 165  (12) , G3087-G3092
All-Diamond Microfiber Electrodes for Neurochemical Analysis
Neurochemical sensing with implantable microelectrodes has created multiple research opportunities in the field of neuroscience. The ability to record extracellular biopotentials and detect neurotransmitters with high sensitivity has enabled deeper understanding of brain and nervous system function. Diamond has many advantages over other electrode materials such as good biocompatibility, wide potential window, low double-layer capacitance, long-term stability, resistance to corrosion/fouling, and fabrication flexibility. In this work, we present a micromachined, implantable, all-diamond microfiber capable of reliable, precise neurochemical sensing. The all-diamond fiber consists of a conductive boron-doped polycrystalline diamond (BDD) core encapsulated in layers of insulating polycrystalline diamond (PCD) cladding. The PCD serves as a biocompatible and hermetic package while also acting as a dielectric barrier to prevent signal cross-talking. The all-diamond microelectrodes were thoroughly characterized using topographical and electrochemical methods. The capability for neurotransmitter sensing was completed using dopamine (DA) as the model analyte. Fast-scan cyclic voltammetry (FSCV) of DA was also completed to demonstrate the practicality for in vivo sensing at rapid rates. The fabrication is described in great detail and the capability for batch-scale process is demonstrated. These novel all-diamond microelectrodes have commercial-scale potential, generating a powerful tool for neurochemical analysis.
- 31 July 2018
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 165  (12) , G3087-G3092
Open AccessAll-Diamond Microfiber Electrodes for Neurochemical Analysis
Neurochemical sensing with implantable microelectrodes has created multiple research opportunities in the field of neuroscience. The ability to record extracellular biopotentials and detect neurotransmitters with high sensitivity has enabled deeper understanding of brain and nervous system function. Diamond has many advantages over other electrode materials such as good biocompatibility, wide potential window, low double-layer capacitance, long-term stability, resistance to corrosion/fouling, and fabrication flexibility. In this work, we present a micromachined, implantable, all-diamond microfiber capable of reliable, precise neurochemical sensing. The all-diamond fiber consists of a conductive boron-doped polycrystalline diamond (BDD) core encapsulated in layers of insulating polycrystalline diamond (PCD) cladding. The PCD serves as a biocompatible and hermetic package while also acting as a dielectric barrier to prevent signal cross-talking. The all-diamond microelectrodes were thoroughly characterized using topographical and electrochemical methods. The capability for neurotransmitter sensing was completed using dopamine (DA) as the model analyte. Fast-scan cyclic voltammetry (FSCV) of DA was also completed to demonstrate the practicality for in vivo sensing at rapid rates. The fabrication is described in great detail and the capability for batch-scale process is demonstrated. These novel all-diamond microelectrodes have commercial-scale potential, generating a powerful tool for neurochemical analysis.