Muhammad Shoaib Almas
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Muhammad Shoaib Almas has a total of 41 co-authors. Here are the top co-authors by number of shared publications:
- Luigi Vanfretti
Rensselaer Polytechnic Institute
31 shared publications - Maxime Baudette
SmarTS Lab, KTH Royal Institute of Technology, Stockholm, Sweden
7 shared publications - Eldrich Rebello
KTH Royal Institute of Technology, Stockholm, Sweden
5 shared publications Austin White
Oklahoma Gas & Electric, Tennessee, USA
2 shared publicationsG.M. Jónsdóttir
2 shared publicationsIyad Al-Khatib
2 shared publications
Latest Publications
- Open Access
- 31 January 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 8, 25800-25810
Experimental Testing of a Real-Time Implementation of a PMU-Based Wide-Area Damping Control System
The modern power grid is being used under operating conditions of increasing stress, giving rise to grid stability issues. One of these stability issues is the phenomenon of inter-area oscillations. Simulations have demonstrated the advantages of Wide-area Measurement Signals (WAMS)-based Oscillation Damping Controls in achieving improved electromechanical mode damping compared to traditional, local signal-based Power System Stabilizers (PSS). This work takes an existing Phasor-based oscillation damping (POD) algorithm and uses it to implement a proof-of-concept, wide-area, real-time controller on National Instruments hardware. The developed prototype is tested in a real-time Hardware-in-the-loop setup (RT-HIL) using OPAL-RT's eMEGASIM real-time simulation platform and synchrophasor data from actual Phasor Measurement Units (PMUs). The prototype and experiments provide insight into the feasibility and real-world limitations of wide-area controls. Further, it is demonstrated how the proposed control architecture has applications independent of the controlled power system device. Challenges faced, the solutions implemented together with the present prototype's limitations are also discussed.
- 31 January 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 8, 25800-25810
Open AccessExperimental Testing of a Real-Time Implementation of a PMU-Based Wide-Area Damping Control System
The modern power grid is being used under operating conditions of increasing stress, giving rise to grid stability issues. One of these stability issues is the phenomenon of inter-area oscillations. Simulations have demonstrated the advantages of Wide-area Measurement Signals (WAMS)-based Oscillation Damping Controls in achieving improved electromechanical mode damping compared to traditional, local signal-based Power System Stabilizers (PSS). This work takes an existing Phasor-based oscillation damping (POD) algorithm and uses it to implement a proof-of-concept, wide-area, real-time controller on National Instruments hardware. The developed prototype is tested in a real-time Hardware-in-the-loop setup (RT-HIL) using OPAL-RT's eMEGASIM real-time simulation platform and synchrophasor data from actual Phasor Measurement Units (PMUs). The prototype and experiments provide insight into the feasibility and real-world limitations of wide-area controls. Further, it is demonstrated how the proposed control architecture has applications independent of the controlled power system device. Challenges faced, the solutions implemented together with the present prototype's limitations are also discussed.
- Open Access
Audur—A platform for synchrophasor-based power system wide-area control system implementation
- 1 July 2017
- Published by Elsevier in Electric Power Systems Research
- Vol. 148, 245-253
A WACS exploiting generator Excitation Boosters for power system transient stability enhancement
- 1 July 2017
- Published by Elsevier in Electric Power Systems Research
- Vol. 148, 245-253
A WACS exploiting generator Excitation Boosters for power system transient stability enhancement
- 7 February 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Smart Grid
- Vol. 9 (5) , 4601-4612
Vulnerability of Synchrophasor-Based WAMPAC Applications’ to Time Synchronization Spoofing
This paper experimentally assesses the impact of time synchronization spoofing attacks (TSSA) on synchrophasor-based wide-area monitoring, protection and control (WAMPAC) applications. Phase angle monitoring, anti-islanding protection, and power oscillation damping applications are investigated. TSSA are created using a real-time (RT) IRIG-B signal generator and power system models are executed using an RT simulator with commercial phasor measurement units (PMUs) coupled to them as hardware-in-the-loop. Because PMUs utilize time synchronization signals to compute synchrophasors, an error in the PMUs' time input introduces a proportional phase error in the voltage or current phase measurements provided by the PMU. The experiments conclude that a phase angle monitoring application will show erroneous power transfers, whereas the anti-islanding protection mal-operates and the damping controller introduces negative damping in the system as a result of the time synchronization error incurred in the PMUs due to TSSA. The proposed test-bench and TSSA approach can be used to investigate the impact of TSSA on any WAMPAC application and to determine the time synchronization error threshold that can be tolerated by these WAMPAC applications.
- 7 February 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Smart Grid
- Vol. 9 (5) , 4601-4612
Vulnerability of Synchrophasor-Based WAMPAC Applications’ to Time Synchronization Spoofing
This paper experimentally assesses the impact of time synchronization spoofing attacks (TSSA) on synchrophasor-based wide-area monitoring, protection and control (WAMPAC) applications. Phase angle monitoring, anti-islanding protection, and power oscillation damping applications are investigated. TSSA are created using a real-time (RT) IRIG-B signal generator and power system models are executed using an RT simulator with commercial phasor measurement units (PMUs) coupled to them as hardware-in-the-loop. Because PMUs utilize time synchronization signals to compute synchrophasors, an error in the PMUs' time input introduces a proportional phase error in the voltage or current phase measurements provided by the PMU. The experiments conclude that a phase angle monitoring application will show erroneous power transfers, whereas the anti-islanding protection mal-operates and the damping controller introduces negative damping in the system as a result of the time synchronization error incurred in the PMUs due to TSSA. The proposed test-bench and TSSA approach can be used to investigate the impact of TSSA on any WAMPAC application and to determine the time synchronization error threshold that can be tolerated by these WAMPAC applications.
- Open Access
- 18 August 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 4, 4659-4668
A Hybrid Synchrophasor and GOOSE-Based Power System Synchronization Scheme
The design and real-time hardware-in-the-loop implementation of a hybrid synchrophasors and GOOSE-based automatic synchronization algorithm are presented in this paper. Automatic synchronization is performed by utilizing the synchrophasor measurements from two commercial phasor measurement units (PMUs), while the coordinated control commands to automatic voltage regulator and/or turbine governor control and trip command to the circuit breaker are issued using IEC 61850-8-1 GOOSE messages. The algorithm is deployed inside the PMU using the protection logic equations, and direct communication between the PMUs is established to minimize the communication latencies. In addition, the algorithm is tested using a standard protection relay test-set, and automatic test sequences are executed to validate its performance. It is concluded that the hybrid synchrophasor and GOOSE-based automatic synchronization scheme ensures minimum communication latencies, reduces equipment cost, facilitates interoperability, and performs automatic reconnection adequately.
- 18 August 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 4, 4659-4668
Open AccessA Hybrid Synchrophasor and GOOSE-Based Power System Synchronization Scheme
The design and real-time hardware-in-the-loop implementation of a hybrid synchrophasors and GOOSE-based automatic synchronization algorithm are presented in this paper. Automatic synchronization is performed by utilizing the synchrophasor measurements from two commercial phasor measurement units (PMUs), while the coordinated control commands to automatic voltage regulator and/or turbine governor control and trip command to the circuit breaker are issued using IEC 61850-8-1 GOOSE messages. The algorithm is deployed inside the PMU using the protection logic equations, and direct communication between the PMUs is established to minimize the communication latencies. In addition, the algorithm is tested using a standard protection relay test-set, and automatic test sequences are executed to validate its performance. It is concluded that the hybrid synchrophasor and GOOSE-based automatic synchronization scheme ensures minimum communication latencies, reduces equipment cost, facilitates interoperability, and performs automatic reconnection adequately.
- 3 December 2015
- Published by Taylor & Francis in Electric Power Components and Systems
- Vol. 44 (2) , 123-134
A Phasor Measurement Unit Based Fast Real-time Oscillation Detection Application for Monitoring Wind-farm-to-grid Sub–synchronous Dynamics
—The increase of wind power share increasing has lead to operational challenges for its integration and impact on power grids. Regarding this, unexpected dynamic phenomena, such as oscillatory events around 13 Hz, among different wind farms were recorded in the United States Oklahoma Gas & Electric. Such interactions differ from traditional inter-area oscillations, and the ability to detect them is the beyond measurement capabilities of most of existing measurement equipment and monitoring tools in energy management systems. This article presents the development and implementation of algorithms for fast sub-synchronous oscillation detection, focusing on the aforementioned case. It proposes a real-time monitoring application that exploits synchronized phasor measurements, allowing real-time detection of sub-synchronous wind farm dynamics. This tool was built as a prototype for real-time application and utilizes phasor measurement unit data for enhanced monitoring and control. The article focuses on the tool’s design and its algorithms. Also, it will briefly present three approaches carried out for testing and validating the phasor measurement unit based application, one of which compares the proposed tool with an existing tool at Oklahoma Gas & Electric. Through such experiments, the tool presented in the article has been positively validated for real-time applications.
- 3 December 2015
- Published by Taylor & Francis in Electric Power Components and Systems
- Vol. 44 (2) , 123-134
A Phasor Measurement Unit Based Fast Real-time Oscillation Detection Application for Monitoring Wind-farm-to-grid Sub–synchronous Dynamics
—The increase of wind power share increasing has lead to operational challenges for its integration and impact on power grids. Regarding this, unexpected dynamic phenomena, such as oscillatory events around 13 Hz, among different wind farms were recorded in the United States Oklahoma Gas & Electric. Such interactions differ from traditional inter-area oscillations, and the ability to detect them is the beyond measurement capabilities of most of existing measurement equipment and monitoring tools in energy management systems. This article presents the development and implementation of algorithms for fast sub-synchronous oscillation detection, focusing on the aforementioned case. It proposes a real-time monitoring application that exploits synchronized phasor measurements, allowing real-time detection of sub-synchronous wind farm dynamics. This tool was built as a prototype for real-time application and utilizes phasor measurement unit data for enhanced monitoring and control. The article focuses on the tool’s design and its algorithms. Also, it will briefly present three approaches carried out for testing and validating the phasor measurement unit based application, one of which compares the proposed tool with an existing tool at Oklahoma Gas & Electric. Through such experiments, the tool presented in the article has been positively validated for real-time applications.
- 27 August 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 31 (3) , 1299-1309
RT-HIL Implementation of the Hybrid Synchrophasor and GOOSE-Based Passive Islanding Schemes
Real-time hardware-in-the-loop performance assessment of three different passive islanding detection methods for local and wide-area synchrophasor measurements is carried out in this paper. Islanding detection algorithms are deployed within the phasor measurement unit (PMU) using logic equations. Tripping decisions are based on local and wide-area synchrophasors as computed by the PMU, and trips are generated using IEC 61850-8-1 generic object-oriented substation event messages. The performance assessment compares these islanding detection schemes for the nondetection zone and operation speed under different operating conditions. The testbench that is demonstrated is useful for a myriad of applications where simulation exercises in power system computer-aided design software provide no realistic insight into the practical design and implementation challenges. Finally, different communication latencies introduced due to the utilization of synchrophasors and IEC 61850-8-1 GOOSE messages are determined.
- 27 August 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 31 (3) , 1299-1309
RT-HIL Implementation of the Hybrid Synchrophasor and GOOSE-Based Passive Islanding Schemes
Real-time hardware-in-the-loop performance assessment of three different passive islanding detection methods for local and wide-area synchrophasor measurements is carried out in this paper. Islanding detection algorithms are deployed within the phasor measurement unit (PMU) using logic equations. Tripping decisions are based on local and wide-area synchrophasors as computed by the PMU, and trips are generated using IEC 61850-8-1 generic object-oriented substation event messages. The performance assessment compares these islanding detection schemes for the nondetection zone and operation speed under different operating conditions. The testbench that is demonstrated is useful for a myriad of applications where simulation exercises in power system computer-aided design software provide no realistic insight into the practical design and implementation challenges. Finally, different communication latencies introduced due to the utilization of synchrophasors and IEC 61850-8-1 GOOSE messages are determined.
- 1 July 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 19325517,p. 1-5
PMU-based real-time damping control system software and hardware architecture synthesis and evaluation
Low-frequency, electromechanically induced, inter-area oscillations are of concern in the continued stability of inter-connected power systems. Wide Area Monitoring, Protection and Control (WAMPAC) systems based on wide-area measurements such as synchrophasor (C37.118) data can be exploited to address the inter-area oscillation problem. This work develops a hardware prototype of a synchrophasor-based oscillation damping control system. A Compact Reconfigurable Input Output (cRIO) controller from National Instruments is used to implement the real-time prototype. This paper presents the design process followed for the development of the software architecture. The design method followed a three step process of design proposal, design refinement and finally attempted implementation. The goals of the design, the challenges faced and the refinements necessary are presented. The design implemented is tested and validated on OPAL-RT's eMEGASIM real-time simulation platform and a brief discussion of the experimental results is included.
- 1 July 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 19325517,p. 1-5
PMU-based real-time damping control system software and hardware architecture synthesis and evaluation
Low-frequency, electromechanically induced, inter-area oscillations are of concern in the continued stability of inter-connected power systems. Wide Area Monitoring, Protection and Control (WAMPAC) systems based on wide-area measurements such as synchrophasor (C37.118) data can be exploited to address the inter-area oscillation problem. This work develops a hardware prototype of a synchrophasor-based oscillation damping control system. A Compact Reconfigurable Input Output (cRIO) controller from National Instruments is used to implement the real-time prototype. This paper presents the design process followed for the development of the software architecture. The design method followed a three step process of design proposal, design refinement and finally attempted implementation. The goals of the design, the challenges faced and the refinements necessary are presented. The design implemented is tested and validated on OPAL-RT's eMEGASIM real-time simulation platform and a brief discussion of the experimental results is included.
- Open Access
- 1 July 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
RT-SIL performance analysis of synchrophasor-and-active load-based power system damping controllers
The Icelandic power network has transmission constraints that often lead to inter-area oscillations. Although conventional stabilization methods have been applied successfully in the past, there is potential to exploit large industrial loads to enhance system stability during stringent operation conditions. This paper analyzes the performance of two damping controllers. The controllers can use both synchrophasor signals and local measurements as their inputs. Damping is achieved by load modulation generated by a phasor-based oscillation signal. Real-Time Software-in-the-Loop testing is performed using Opal-RT's eMEGAsim Real-Time Simulator to derive hardware and computational requirements of a hardware prototype that will be implemented in the future.
- 1 July 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Open AccessRT-SIL performance analysis of synchrophasor-and-active load-based power system damping controllers
The Icelandic power network has transmission constraints that often lead to inter-area oscillations. Although conventional stabilization methods have been applied successfully in the past, there is potential to exploit large industrial loads to enhance system stability during stringent operation conditions. This paper analyzes the performance of two damping controllers. The controllers can use both synchrophasor signals and local measurements as their inputs. Damping is achieved by load modulation generated by a phasor-based oscillation signal. Real-Time Software-in-the-Loop testing is performed using Opal-RT's eMEGAsim Real-Time Simulator to derive hardware and computational requirements of a hardware prototype that will be implemented in the future.