Jie Chen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Jie Chen has a total of 45 co-authors. Here are the top co-authors by number of shared publications:
Feifei Jiang
8 shared publicationsZeyang Xia
Associate professor, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences and Chinese University of Hong Kong, Hong Kong, China
5 shared publicationsShuning Li
Visiting assistant professor, Department of Mechanical Engineering, Indiana University-Purdue University, Indianapolis, Ind
4 shared publicationsGeorge Eckert
Department of Biostatistics, Indiana University, Indianapolis, Ind
3 shared publications- Amin Akbari
Department of Mechanical and Energy Engineering, Indiana University Purdue University Indianapolis, Indianapolis, Ind
2 shared publications - Da-Chun Wu
School of Mechanical Engineering, Purdue University, Indianapolis, Indiana, USA
2 shared publications
Latest Publications
- Open Access
- 12 April 2026
- Published by Association for Computing Machinery (ACM)
- p. 50-57
The Energy Consumption Graph: A Model-Based Architecture for IIoT-based Industrial Energy Auditing
- 12 April 2026
- Published by Association for Computing Machinery (ACM)
- p. 50-57
Open AccessThe Energy Consumption Graph: A Model-Based Architecture for IIoT-based Industrial Energy Auditing
- Open Access
- 6 February 2026
- Published by Association for Computing Machinery (ACM)
- p. 1-8
IEAF - A Scalable Graph-Based Energy Modeling for Real-Time Industrial Auditing
Traditional energy audits often fail to capture dynamic inefficiencies due to a fundamental gap between physical industrial processes and actionable data. This paper introduces the IIoT-based Energy Auditing Framework (IEAF), an open-source, vendor-agnostic architecture designed to provide continuous, scalable, and data-driven energy management. IEAF operationalizes facility-wide energy monitoring by instantiating the hierarchical Energy Consumption Graph (ECG), which acts as a cyber-physical model translating raw sensor streams into a structured real-time digital representation. Through multi-year case studies in industrial and academic settings, IEAF has demonstrated the ability to uncover previously hidden energy inefficiencies, enabling targeted interventions and measurable energy savings. The primary contribution of this work is a customer-specific, data-centric framework that bridges the gap between industrial operations and actionable energy insights, supporting continuous optimization and operational decision-making.
- 6 February 2026
- Published by Association for Computing Machinery (ACM)
- p. 1-8
Open AccessIEAF - A Scalable Graph-Based Energy Modeling for Real-Time Industrial Auditing
Traditional energy audits often fail to capture dynamic inefficiencies due to a fundamental gap between physical industrial processes and actionable data. This paper introduces the IIoT-based Energy Auditing Framework (IEAF), an open-source, vendor-agnostic architecture designed to provide continuous, scalable, and data-driven energy management. IEAF operationalizes facility-wide energy monitoring by instantiating the hierarchical Energy Consumption Graph (ECG), which acts as a cyber-physical model translating raw sensor streams into a structured real-time digital representation. Through multi-year case studies in industrial and academic settings, IEAF has demonstrated the ability to uncover previously hidden energy inefficiencies, enabling targeted interventions and measurable energy savings. The primary contribution of this work is a customer-specific, data-centric framework that bridges the gap between industrial operations and actionable energy insights, supporting continuous optimization and operational decision-making.
- Open Access
- 25 October 2022
- Published by Elsevier in American Journal of Orthodontics and Dentofacial Orthopedics
- Vol. 162 (6) , e328-e336
The effects of different types of periodontal ligament material models on stresses computed using finite element models
- 25 October 2022
- Published by Elsevier in American Journal of Orthodontics and Dentofacial Orthopedics
- Vol. 162 (6) , e328-e336
Open AccessThe effects of different types of periodontal ligament material models on stresses computed using finite element models
- 1 August 2022
- Published by Elsevier in American Journal of Orthodontics and Dentofacial Orthopedics
- Vol. 162 (2) , 229-237
Peak loads on teeth from a generic mouthpiece of a vibration device for accelerating tooth movement
- 1 August 2022
- Published by Elsevier in American Journal of Orthodontics and Dentofacial Orthopedics
- Vol. 162 (2) , 229-237
Peak loads on teeth from a generic mouthpiece of a vibration device for accelerating tooth movement
- 30 June 2022
- Published by Office of Scientific and Technical Information (OSTI)
Industrial Assessment Center – integration of education and practice. Final progress report
The goal of the DOE’s Industrial Assessment Center (IAC) program is twofold: first, to help US manufacturing competitiveness by providing assessments and recommendations for small and medium-sized enterprises (SMEs) on energy efficiency, productivity, sustainability and competitiveness – including measuring the impacts of these recommendations on reducing greenhouse gas emissions; and second, to address a growing shortage of engineering professionals with applied energy and manufacturing-related skills by training a diverse cross-section of engineering students through hands-on involvement in these assessments. IUPUI has an IAC, which was established in 2011, in the Department of Mechanical and Energy Engineering, Purdue School of Engineering and Technology, IUPUI. The IAC has won the awards twice. We have built the center that has the expertise and infrastructure for quality energy assessments to manufactures and commercial building owners and aligned our current research and teaching activities to the DOE’ training mission with programs to train the next generation of industrial energy efficiency experts, with theory and hands-on experience in conducting energy assessment for small and median manufacturing enterprises. We have made recommendations that have the potential to save about $20M annually. We also initiated research projects to meet DOE priorities, specifically in the areas of smart manufacturingmore » and cybersecurity. On the energy assessment side, the Center has provided energy assessments to 144 qualified companies, primarily located in Indiana. On the training side, the center has trained students in various programs, such as the department’s Bachelor of Science (BS) programs in Mechanical Engineering (ME) and BS in Energy Engineering (EEN), both are ABET accredited engineering programs, as well as a graduate level Energy Management and Assessment certificate program. At the present, the center has trained 95 students, 43 or them received the DOE issued certificates. Research projects were developed within the center to advance energy efficiency related technologies, which provided excellent opportunities for our trainees. The center has also been building a professional network with utilities, Manufacturing Extension Partnership (MEP), government agencies, and manufacturing companies, to increase our client base and promote collaborations. The center received the 2019 Center of Excellence of the Year Award and three students received the “Outstanding Achievement in Energy Engineering by an IAC Student” awards in the past five years. « less
- 30 June 2022
- Published by Office of Scientific and Technical Information (OSTI)
Industrial Assessment Center – integration of education and practice. Final progress report
The goal of the DOE’s Industrial Assessment Center (IAC) program is twofold: first, to help US manufacturing competitiveness by providing assessments and recommendations for small and medium-sized enterprises (SMEs) on energy efficiency, productivity, sustainability and competitiveness – including measuring the impacts of these recommendations on reducing greenhouse gas emissions; and second, to address a growing shortage of engineering professionals with applied energy and manufacturing-related skills by training a diverse cross-section of engineering students through hands-on involvement in these assessments. IUPUI has an IAC, which was established in 2011, in the Department of Mechanical and Energy Engineering, Purdue School of Engineering and Technology, IUPUI. The IAC has won the awards twice. We have built the center that has the expertise and infrastructure for quality energy assessments to manufactures and commercial building owners and aligned our current research and teaching activities to the DOE’ training mission with programs to train the next generation of industrial energy efficiency experts, with theory and hands-on experience in conducting energy assessment for small and median manufacturing enterprises. We have made recommendations that have the potential to save about $20M annually. We also initiated research projects to meet DOE priorities, specifically in the areas of smart manufacturingmore » and cybersecurity. On the energy assessment side, the Center has provided energy assessments to 144 qualified companies, primarily located in Indiana. On the training side, the center has trained students in various programs, such as the department’s Bachelor of Science (BS) programs in Mechanical Engineering (ME) and BS in Energy Engineering (EEN), both are ABET accredited engineering programs, as well as a graduate level Energy Management and Assessment certificate program. At the present, the center has trained 95 students, 43 or them received the DOE issued certificates. Research projects were developed within the center to advance energy efficiency related technologies, which provided excellent opportunities for our trainees. The center has also been building a professional network with utilities, Manufacturing Extension Partnership (MEP), government agencies, and manufacturing companies, to increase our client base and promote collaborations. The center received the 2019 Center of Excellence of the Year Award and three students received the “Outstanding Achievement in Energy Engineering by an IAC Student” awards in the past five years. « less
- 14 June 2022
- Published by Elsevier in Journal of the World Federation of Orthodontists
- Vol. 11 (4) , 95-106
Integrating skeletal anchorage into fixed and aligner biomechanics
- 14 June 2022
- Published by Elsevier in Journal of the World Federation of Orthodontists
- Vol. 11 (4) , 95-106
Integrating skeletal anchorage into fixed and aligner biomechanics
- 1 November 2020
- Published by The Angle Orthodontist (EH Angle Education & Research Foundation) in The Angle Orthodontist
- Vol. 90 (6) , 801-810
Mechanical environment for lower canine T-loop retraction compared to en-masse space closure with a power-arm attached to either the canine bracket or the archwire
Objectives: To assess the mechanical environment for three fixed appliances designed to retract the lower anterior segment. Materials and Methods: A cone-beam computed tomography scan provided three-dimensional morphology to construct finite element models for three common methods of lower anterior retraction into first premolar extraction spaces: (1) canine retraction with a T-loop, (2) en-masse space closure with the power-arm on the canine bracket (PAB), and (3) power-arm directly attached to the archwire mesial to the canine (PAW). Half of the symmetric mandibular arch was modeled as a linear, isotropic composite material containing five teeth: central incisors (L1), lateral incisor (L2), canine (L3), second premolar (L4), and first molar (L5). Bonded brackets had 0.022-in slots. Archwire and power-arm components were 0.016 × 0.022 in. An initial retraction force of 125 cN was used for all three appliances. Displacements were calculated. Periodontal ligament (PDL) stresses and distributions were calculated for four invariants: maximum principal, minimum principal, von Mises, and dilatational stresses. Results: The PDL stress distributions for the four invariants corresponded to the displacement patterns for each appliance. T-loop tipped the canine(s) and incisors distally. PAB rotated L3 distal in, intruded L2, and extruded L1. PAW distorted the archwire resulting in L3 extrusion as well as lingual tipping of L1 and L2. Maximum stress levels in the PDL were up to 5× greater for the PAW than the T-loop and PAB methods. Conclusions: T-loop of this type is more predictable because power-arms can have rotational and archwire distortion effects that result in undesirable paths of tooth movement.
- 1 November 2020
- Published by The Angle Orthodontist (EH Angle Education & Research Foundation) in The Angle Orthodontist
- Vol. 90 (6) , 801-810
Mechanical environment for lower canine T-loop retraction compared to en-masse space closure with a power-arm attached to either the canine bracket or the archwire
Objectives: To assess the mechanical environment for three fixed appliances designed to retract the lower anterior segment. Materials and Methods: A cone-beam computed tomography scan provided three-dimensional morphology to construct finite element models for three common methods of lower anterior retraction into first premolar extraction spaces: (1) canine retraction with a T-loop, (2) en-masse space closure with the power-arm on the canine bracket (PAB), and (3) power-arm directly attached to the archwire mesial to the canine (PAW). Half of the symmetric mandibular arch was modeled as a linear, isotropic composite material containing five teeth: central incisors (L1), lateral incisor (L2), canine (L3), second premolar (L4), and first molar (L5). Bonded brackets had 0.022-in slots. Archwire and power-arm components were 0.016 × 0.022 in. An initial retraction force of 125 cN was used for all three appliances. Displacements were calculated. Periodontal ligament (PDL) stresses and distributions were calculated for four invariants: maximum principal, minimum principal, von Mises, and dilatational stresses. Results: The PDL stress distributions for the four invariants corresponded to the displacement patterns for each appliance. T-loop tipped the canine(s) and incisors distally. PAB rotated L3 distal in, intruded L2, and extruded L1. PAW distorted the archwire resulting in L3 extrusion as well as lingual tipping of L1 and L2. Maximum stress levels in the PDL were up to 5× greater for the PAW than the T-loop and PAB methods. Conclusions: T-loop of this type is more predictable because power-arms can have rotational and archwire distortion effects that result in undesirable paths of tooth movement.
- 1 August 2019
- Published by Elsevier in American Journal of Orthodontics and Dentofacial Orthopedics
- Vol. 156 (2) , 203-209
Comparison of movement rate with different initial moment-to-force ratios
- 1 August 2019
- Published by Elsevier in American Journal of Orthodontics and Dentofacial Orthopedics
- Vol. 156 (2) , 203-209
Comparison of movement rate with different initial moment-to-force ratios
- 14 November 2018
- Published by Wiley in International Journal for Numerical Methods in Biomedical Engineering
- Vol. 35 (3) , e3169
Can interfaces at bracket‐wire and between teeth in multi‐teeth finite element model be simplified?
Objective Finite element (FE) method's correctness depends heavily on modeling method. This study aimed at determining whether the interfaces at bracket‐wire and between teeth can be simplified for multi‐teeth FE analysis. Method A three‐dimensional FE model of a mandible was created from cone‐beam computed tomography scan. Due to symmetry, only a half of the mandible was modeled, which consisted of five teeth (1st premolar extraction and only 1st molar), brackets and archwire, periodontal ligament (PDL), cortical bone and cancellous bone. All the bone, teeth, PDL were considered to be isotropic and linear. The En‐masse retraction case was simulated. A detailed model, which has contact elements between the bracket and archwire and between teeth, was developed to allow relative motion at the interfaces. A model with simplified interfacial conditions, which does not allow the relative motion, was also created. The stresses and displacements as results of the treatment on these two models were calculated and compared. Results The stress and displacement distributions from the detailed model were more close to reality based on the expected displacement pattern of the clinical case than from the simplified model. The maximum stresses from the two methods were also different. The highest stress from the detailed model is twice as high as from the simplified model. Conclusions The detailed model provides much more reasonable results than the simplified model. Thus, the simplified model should not be used to replace the detailed model if the stress magnitude and highest stress location are the expected outcomes.
- 14 November 2018
- Published by Wiley in International Journal for Numerical Methods in Biomedical Engineering
- Vol. 35 (3) , e3169
Can interfaces at bracket‐wire and between teeth in multi‐teeth finite element model be simplified?
Objective Finite element (FE) method's correctness depends heavily on modeling method. This study aimed at determining whether the interfaces at bracket‐wire and between teeth can be simplified for multi‐teeth FE analysis. Method A three‐dimensional FE model of a mandible was created from cone‐beam computed tomography scan. Due to symmetry, only a half of the mandible was modeled, which consisted of five teeth (1st premolar extraction and only 1st molar), brackets and archwire, periodontal ligament (PDL), cortical bone and cancellous bone. All the bone, teeth, PDL were considered to be isotropic and linear. The En‐masse retraction case was simulated. A detailed model, which has contact elements between the bracket and archwire and between teeth, was developed to allow relative motion at the interfaces. A model with simplified interfacial conditions, which does not allow the relative motion, was also created. The stresses and displacements as results of the treatment on these two models were calculated and compared. Results The stress and displacement distributions from the detailed model were more close to reality based on the expected displacement pattern of the clinical case than from the simplified model. The maximum stresses from the two methods were also different. The highest stress from the detailed model is twice as high as from the simplified model. Conclusions The detailed model provides much more reasonable results than the simplified model. Thus, the simplified model should not be used to replace the detailed model if the stress magnitude and highest stress location are the expected outcomes.
- Open Access
- 20 July 2018
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 23 (07) , 075008-8
Dose analysis of photobiomodulation therapy on osteoblast, osteoclast, and osteocyte
The objective of this study was to evaluate the effects of varying light doses on the viability and cellular activity of osteoblasts, osteocytes, and osteoclasts. A light application device was developed to apply 940-nm wavelength light from light-emitting diodes on three cultured cells, MC3T3-E1, MLO-A5, and RANKL-treated RAW264.7 cells. The doses (energy density) on cells were 0, 1, 5, and 7.5 J / cm2. The corresponding light power densities at the cell site were 0, 1.67, 8.33, and 12.5 mW / cm2, respectively, and the duration was 10 min. The results showed that the three cell types respond differently to light and their responses were dose dependent. Low-dose treatment (1 J / cm2) enhanced osteoblast proliferation, osteoclast differentiation, and osteoclastic bone resorption activity. Osteocyte proliferation was not affected by both low- and high-dose (5 J / cm2) treatments. While 1 J / cm2 did not affect viability of all three cell types, 5 J / cm2 significantly decreased viability of osteocytes and osteoclasts. Osteoblast viability was negatively impacted by the higher dose (7.5 J / cm2). The findings suggest that optimal doses exist for osteoblast and osteoclast, which can stimulate cell activities, and there is a safe dose range for each type of cell tested.
- 20 July 2018
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 23 (07) , 075008-8
Open AccessDose analysis of photobiomodulation therapy on osteoblast, osteoclast, and osteocyte
The objective of this study was to evaluate the effects of varying light doses on the viability and cellular activity of osteoblasts, osteocytes, and osteoclasts. A light application device was developed to apply 940-nm wavelength light from light-emitting diodes on three cultured cells, MC3T3-E1, MLO-A5, and RANKL-treated RAW264.7 cells. The doses (energy density) on cells were 0, 1, 5, and 7.5 J / cm2. The corresponding light power densities at the cell site were 0, 1.67, 8.33, and 12.5 mW / cm2, respectively, and the duration was 10 min. The results showed that the three cell types respond differently to light and their responses were dose dependent. Low-dose treatment (1 J / cm2) enhanced osteoblast proliferation, osteoclast differentiation, and osteoclastic bone resorption activity. Osteocyte proliferation was not affected by both low- and high-dose (5 J / cm2) treatments. While 1 J / cm2 did not affect viability of all three cell types, 5 J / cm2 significantly decreased viability of osteocytes and osteoclasts. Osteoblast viability was negatively impacted by the higher dose (7.5 J / cm2). The findings suggest that optimal doses exist for osteoblast and osteoclast, which can stimulate cell activities, and there is a safe dose range for each type of cell tested.