Michael H. Bierhoff
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Michael H. Bierhoff has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Hafiz Ahmed
The University of Sheffield
2 shared publications - Jose R. Espinoza
Department of Electrical Engineering, University of Concepción, Concepción, Chile
1 shared publication - Mohamed Benbouzid
Institut de Recherche Dupuy de Lôme (UMR CNRS 6027), University of Brest, 29238 Brest, France
1 shared publication - Ramy Soliman
Stralsund University of Applied Sciences, 84592 Stralsund, Mecklenburg-Vorpommern Germany
1 shared publication - Sid-Ali Amamra
School of Computing and Engineering, University of Huddersfield, Queensgate, Huddersfield HD1 3DH, UK
1 shared publication
Latest Publications
- Open Access
- 15 May 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Journal of Power Electronics
- Vol. 1, 161-169
Analysis and Design of Grid-Tied Inverter With LCL Filter
The LCL filter represents the state-of-the-art passive interface type for grid tied power converters as a cost and space reducing alternative to single coil solutions for switching harmonic attenuation. However, a simple PI controller can cause instabilities when applied to control the current of this filter. Thus a unified analytically closed approach is presented to determine the safe operating areas for both grid current control mode (GCM) and inverter current control mode (ICM), both with and without additional active damping feedback of the capacitor current. The proposed approach consequently applies the Nyquist criterion in the continuous frequency domain, facilitating the determination of very simple expressions of parameter stability limits. These design guidelines, which partially also confirm previous findings, are for the first time summarized all together as the results of a unified approach.
- 15 May 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Journal of Power Electronics
- Vol. 1, 161-169
Open AccessAnalysis and Design of Grid-Tied Inverter With LCL Filter
The LCL filter represents the state-of-the-art passive interface type for grid tied power converters as a cost and space reducing alternative to single coil solutions for switching harmonic attenuation. However, a simple PI controller can cause instabilities when applied to control the current of this filter. Thus a unified analytically closed approach is presented to determine the safe operating areas for both grid current control mode (GCM) and inverter current control mode (ICM), both with and without additional active damping feedback of the capacitor current. The proposed approach consequently applies the Nyquist criterion in the continuous frequency domain, facilitating the determination of very simple expressions of parameter stability limits. These design guidelines, which partially also confirm previous findings, are for the first time summarized all together as the results of a unified approach.
- 25 July 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 69 (6) , 2817-2825
Multiple Nonlinear Harmonic Oscillator-Based Frequency Estimation for Distorted Grid Voltage
In the presence of nonlinear loads and various disturbances, harmonics and DC bias may corrupt the grid voltage signal leading to distorted grid. Frequency estimation of distorted grid signal is a challenging issue. In this paper, multiresonant nonlinear harmonic oscillators based frequency estimation technique is reported for distorted power grid. The proposed approach has also been applied for detecting the sequences of unbalanced grid. In the proposed approach, a nonlinear harmonic oscillator is used as the proxy of the grid signal. Then using the frequency-locked loop, an adaptive approach is proposed to estimate the frequency and other parameters (sequences) in the presence of harmonics and DC component. Local stability analysis and parameter tuning are provided. Comparative experimental results are provided with two other nonlinear state of the art techniques. Experimental results demonstrated the suitability of the proposed technique.
- 25 July 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 69 (6) , 2817-2825
Multiple Nonlinear Harmonic Oscillator-Based Frequency Estimation for Distorted Grid Voltage
In the presence of nonlinear loads and various disturbances, harmonics and DC bias may corrupt the grid voltage signal leading to distorted grid. Frequency estimation of distorted grid signal is a challenging issue. In this paper, multiresonant nonlinear harmonic oscillators based frequency estimation technique is reported for distorted power grid. The proposed approach has also been applied for detecting the sequences of unbalanced grid. In the proposed approach, a nonlinear harmonic oscillator is used as the proxy of the grid signal. Then using the frequency-locked loop, an adaptive approach is proposed to estimate the frequency and other parameters (sequences) in the presence of harmonics and DC component. Local stability analysis and parameter tuning are provided. Comparative experimental results are provided with two other nonlinear state of the art techniques. Experimental results demonstrated the suitability of the proposed technique.
- 8 October 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 66 (11) , 8856-8859
Frequency-Locked Loop-Based Estimation of Single-Phase Grid Voltage Parameters
Estimation of Amplitude, instantaneous phase and frequency of single-phase grid voltage signal have been studied in this paper. The proposed approach uses a novel circular limit cycle oscillator (CLO) coupled with frequency-locked loop (FLL). Due to the nonlinear structure of the CLO, the proposed frequency adaptive CLO technique is robust against various perturbations faced in the practical settings e.g. discontinuous jump of phase, frequency and amplitude. Global stability analysis of the CLO and local stability analysis of the frequency adaptive CLO has been performed. Experimental results demonstrate the effectiveness of the proposed technique over a very recent technique proposed in the literature.
- 8 October 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 66 (11) , 8856-8859
Frequency-Locked Loop-Based Estimation of Single-Phase Grid Voltage Parameters
Estimation of Amplitude, instantaneous phase and frequency of single-phase grid voltage signal have been studied in this paper. The proposed approach uses a novel circular limit cycle oscillator (CLO) coupled with frequency-locked loop (FLL). Due to the nonlinear structure of the CLO, the proposed frequency adaptive CLO technique is robust against various perturbations faced in the practical settings e.g. discontinuous jump of phase, frequency and amplitude. Global stability analysis of the CLO and local stability analysis of the frequency adaptive CLO has been performed. Experimental results demonstrate the effectiveness of the proposed technique over a very recent technique proposed in the literature.
- 2 June 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 64 (12) , 9253-9260
A General PLL-Type Algorithm for Speed Sensorless Control of Electrical Drives
Speed control of electrical drives without additional speed sensors is preferable in terms of cost and maintenance effort. Common approaches are either simple but inaccurate with deteriorated drive performance in the low-speed range, or they offer full torque even at zero speed at the cost of high implementation effort and parameter sensitivity. Moreover, most of the suggested solutions are tailor made for specific machine types. The proposed method constitutes a simple phase-locked-loop-type sensorless algorithm that can be related to the former category. The outstanding feature of the presented method is its effectiveness and simplicity at the same time. This paper presents corresponding design guidelines for an easy to implement and robust speed sensorless control algorithm for all kinds of electrical machines that includes induction machines as well as synchronous reluctance machines with and without extra/permanent excitation.
- 2 June 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 64 (12) , 9253-9260
A General PLL-Type Algorithm for Speed Sensorless Control of Electrical Drives
Speed control of electrical drives without additional speed sensors is preferable in terms of cost and maintenance effort. Common approaches are either simple but inaccurate with deteriorated drive performance in the low-speed range, or they offer full torque even at zero speed at the cost of high implementation effort and parameter sensitivity. Moreover, most of the suggested solutions are tailor made for specific machine types. The proposed method constitutes a simple phase-locked-loop-type sensorless algorithm that can be related to the former category. The outstanding feature of the presented method is its effectiveness and simplicity at the same time. This paper presents corresponding design guidelines for an easy to implement and robust speed sensorless control algorithm for all kinds of electrical machines that includes induction machines as well as synchronous reluctance machines with and without extra/permanent excitation.