Iori Sumida
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Iori Sumida has a total of 108 co-authors. Here are the top co-authors by number of shared publications:
Kazuhiko Ogawa
Department of Radiation Oncology, Osaka University Graduate School of Medicine, 2-2 Yamada-oka, Suita, Osaka, Japan
13 shared publications- Fumiaki Isohashi
Department of Radiation Oncology Nara Medical University Kashihara Nara Japan
10 shared publications Osamu Suzuki
Department of Radiation Oncology, Osaka University Graduate School of Medicine, Osaka, 565-0871, Japan
9 shared publicationsYasuo Yoshioka
Department of Radiation Oncology, Cancer Institute Hospital of Japanese Foundation for Cancer Research, Koto-ku, Tokyo, Japan
9 shared publicationsYuji Seo
Department of Radiation Oncology, Osaka University Graduate School of Medicine, 2-2 Yamada-oka, Suita, Osaka, Japan
9 shared publicationsHajime Yamaguchi
Department of Radiation Oncology, NTT West Osaka hospital, 2-6-40 Karasugatsuji, Tennoji-ku, Osaka, Japan
8 shared publications
Latest Publications
- Open Access
- 19 April 2021
- Published by Oxford University Press (OUP) in Journal of Radiation Research
- Vol. 62 (3) , 494-501
Dose rate in the highest irradiation area of the rectum correlates with late rectal complications in patients treated with high-dose-rate computed tomography-based image-guided brachytherapy for cervical cancer
The purpose of this study was to evaluate the effect of dose rate to the rectum on late rectal complications in patients treated with computed tomography (CT)-based image-guided brachytherapy (IGBT) for cervical cancer. The subjects were 142 patients with cervical cancer who underwent Ir-192 high-dose-rate (HDR)-IGBT between March 2012 and January 2018. The dose rate to the rectum was calculated using in-house software. The minimum, mean and maximum effective dose rate (EDR) was calculated for voxels of the rectal volume covered by cumulative doses >D0.1cc, >D2cc, and > D5cc. The average EDR of three to four brachytherapy sessions was calculated (EDR for patients; EDRp). The total dose of the rectum was calculated as the biologically equivalent dose in 2-Gy fractions (EQD2). The associations between EDRp for D0.1cc, D2cc, and D5cc and the respective rectal EQD2 values with late rectal complications were then analyzed. The median follow-up period was 40 months. Patients with rectal complications of ≥Grade 1 received a significantly higher mean EDRp for D0.1cc–5cc and had a greater EQD2 for D0.1cc–5cc. Multivariate analysis was performed using the mean EDRp for D2cc, EQD2 for D2cc, heavy smoking and BMI. Of these four variables, mean EDRp for D2cc (HR = 3.38, p = 0.004) and EQD2 for D2cc (HR = 2.59, p = 0.045) emerged as independent predictors for late rectal complications. In conclusion, mean EDRp and EQD2 were associated with late rectal complications in patients treated with HDR CT-based IGBT for cervical cancer.
- 19 April 2021
- Published by Oxford University Press (OUP) in Journal of Radiation Research
- Vol. 62 (3) , 494-501
Open AccessDose rate in the highest irradiation area of the rectum correlates with late rectal complications in patients treated with high-dose-rate computed tomography-based image-guided brachytherapy for cervical cancer
The purpose of this study was to evaluate the effect of dose rate to the rectum on late rectal complications in patients treated with computed tomography (CT)-based image-guided brachytherapy (IGBT) for cervical cancer. The subjects were 142 patients with cervical cancer who underwent Ir-192 high-dose-rate (HDR)-IGBT between March 2012 and January 2018. The dose rate to the rectum was calculated using in-house software. The minimum, mean and maximum effective dose rate (EDR) was calculated for voxels of the rectal volume covered by cumulative doses >D0.1cc, >D2cc, and > D5cc. The average EDR of three to four brachytherapy sessions was calculated (EDR for patients; EDRp). The total dose of the rectum was calculated as the biologically equivalent dose in 2-Gy fractions (EQD2). The associations between EDRp for D0.1cc, D2cc, and D5cc and the respective rectal EQD2 values with late rectal complications were then analyzed. The median follow-up period was 40 months. Patients with rectal complications of ≥Grade 1 received a significantly higher mean EDRp for D0.1cc–5cc and had a greater EQD2 for D0.1cc–5cc. Multivariate analysis was performed using the mean EDRp for D2cc, EQD2 for D2cc, heavy smoking and BMI. Of these four variables, mean EDRp for D2cc (HR = 3.38, p = 0.004) and EQD2 for D2cc (HR = 2.59, p = 0.045) emerged as independent predictors for late rectal complications. In conclusion, mean EDRp and EQD2 were associated with late rectal complications in patients treated with HDR CT-based IGBT for cervical cancer.
- 14 February 2020
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 93 (1109) , 20190625
Impact of accumulated alterations in driver and passenger genes on response to radiation therapy
Objective: Although various single genetic factors have been shown to affect radiosensitivity, high-throughput DNA sequencing analyses have revealed complex genomic landscapes in many cancer types. The aim of this study is to elucidate the association between accumulated alterations in driver and passenger genes and radiation therapy response. Methods: We used 59 human solid cancer cell lines derived from 11 organ sites. Radiation-induced cell death was measured using a standard colony-forming assay delivered as a single dose ranging from 0 to 12 Gy. Comprehensive genomic data for the cell lines were acquired from the Catalogue Of Somatic Mutations In Cancer v. 80. Random forest classifiers were constructed to predict radioresistant phenotypes using genomic features. The Cancer Genome Atlas data sets were used to evaluate the clinical impact of the genomic feature following radiotherapy. Results: The 59 cancer cell lines harbored either nucleotide variations or copy number variations in a median of 157 genes per cell. Radiosensitivity of the cancer cells was correlated with neither the number of driver gene mutations nor the number of passenger gene mutations. However, the proportion of driver gene alterations to total gene alterations in gene sets selected from the Kyoto Encyclopedia Genes and Genomes predicted radioresistant cells with sensitivity of 85% and specificity of 73%. High probability of radioresistance predicted by the model was associated with worse overall survival following definitive radiotherapy in patients of The Cancer Genome Atlas data sets. Conclusion: Cellular radiosensitivity was associated with the proportion of driver to total gene alterations in the selected oncogenic pathways, which may be a biomarker candidate for response to radiation therapy. Advances in knowledge: These findings suggest that accumulated alterations in not only driver genes but also passenger genes affect radiosensitivity.
- 14 February 2020
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 93 (1109) , 20190625
Impact of accumulated alterations in driver and passenger genes on response to radiation therapy
Objective: Although various single genetic factors have been shown to affect radiosensitivity, high-throughput DNA sequencing analyses have revealed complex genomic landscapes in many cancer types. The aim of this study is to elucidate the association between accumulated alterations in driver and passenger genes and radiation therapy response. Methods: We used 59 human solid cancer cell lines derived from 11 organ sites. Radiation-induced cell death was measured using a standard colony-forming assay delivered as a single dose ranging from 0 to 12 Gy. Comprehensive genomic data for the cell lines were acquired from the Catalogue Of Somatic Mutations In Cancer v. 80. Random forest classifiers were constructed to predict radioresistant phenotypes using genomic features. The Cancer Genome Atlas data sets were used to evaluate the clinical impact of the genomic feature following radiotherapy. Results: The 59 cancer cell lines harbored either nucleotide variations or copy number variations in a median of 157 genes per cell. Radiosensitivity of the cancer cells was correlated with neither the number of driver gene mutations nor the number of passenger gene mutations. However, the proportion of driver gene alterations to total gene alterations in gene sets selected from the Kyoto Encyclopedia Genes and Genomes predicted radioresistant cells with sensitivity of 85% and specificity of 73%. High probability of radioresistance predicted by the model was associated with worse overall survival following definitive radiotherapy in patients of The Cancer Genome Atlas data sets. Conclusion: Cellular radiosensitivity was associated with the proportion of driver to total gene alterations in the selected oncogenic pathways, which may be a biomarker candidate for response to radiation therapy. Advances in knowledge: These findings suggest that accumulated alterations in not only driver genes but also passenger genes affect radiosensitivity.
- Open Access
- 24 May 2019
- Published by Oxford University Press (OUP) in Journal of Radiation Research
- Vol. 60 (5) , 586-594
Deep convolutional neural network for reduction of contrast-enhanced region on CT images
This study aims to produce non-contrast computed tomography (CT) images using a deep convolutional neural network (CNN) for imaging. Twenty-nine patients were selected. CT images were acquired without and with a contrast enhancement medium. The transverse images were divided into 64 × 64 pixels. This resulted in 14 723 patches in total for both non-contrast and contrast-enhanced CT image pairs. The proposed CNN model comprises five two-dimensional (2D) convolution layers with one shortcut path. For comparison, the U-net model, which comprises five 2D convolution layers interleaved with pooling and unpooling layers, was used. Training was performed in 24 patients and, for testing of trained models, another 5 patients were used. For quantitative evaluation, 50 regions of interest (ROIs) were selected on the reference contrast-enhanced image of the test data, and the mean pixel value of the ROIs was calculated. The mean pixel values of the ROIs at the same location on the reference non-contrast image and the predicted non-contrast image were calculated and those values were compared. Regarding the quantitative analysis, the difference in mean pixel value between the reference contrast-enhanced image and the predicted non-contrast image was significant (P < 0.0001) for both models. Significant differences in pixels (P < 0.0001) were found using the U-net model; in contrast, there was no significant difference using the proposed CNN model when comparing the reference non-contrast images and the predicted non-contrast images. Using the proposed CNN model, the contrast-enhanced region was satisfactorily reduced.
- 24 May 2019
- Published by Oxford University Press (OUP) in Journal of Radiation Research
- Vol. 60 (5) , 586-594
Open AccessDeep convolutional neural network for reduction of contrast-enhanced region on CT images
This study aims to produce non-contrast computed tomography (CT) images using a deep convolutional neural network (CNN) for imaging. Twenty-nine patients were selected. CT images were acquired without and with a contrast enhancement medium. The transverse images were divided into 64 × 64 pixels. This resulted in 14 723 patches in total for both non-contrast and contrast-enhanced CT image pairs. The proposed CNN model comprises five two-dimensional (2D) convolution layers with one shortcut path. For comparison, the U-net model, which comprises five 2D convolution layers interleaved with pooling and unpooling layers, was used. Training was performed in 24 patients and, for testing of trained models, another 5 patients were used. For quantitative evaluation, 50 regions of interest (ROIs) were selected on the reference contrast-enhanced image of the test data, and the mean pixel value of the ROIs was calculated. The mean pixel values of the ROIs at the same location on the reference non-contrast image and the predicted non-contrast image were calculated and those values were compared. Regarding the quantitative analysis, the difference in mean pixel value between the reference contrast-enhanced image and the predicted non-contrast image was significant (P < 0.0001) for both models. Significant differences in pixels (P < 0.0001) were found using the U-net model; in contrast, there was no significant difference using the proposed CNN model when comparing the reference non-contrast images and the predicted non-contrast images. Using the proposed CNN model, the contrast-enhanced region was satisfactorily reduced.
- Open Access
- 26 February 2019
- Published by Springer Nature in Radiation Oncology
- Vol. 14 (1) , 1-11
Comparison of gamma index based on dosimetric error and clinically relevant dose–volume index based on three-dimensional dose prediction in breast intensity-modulated radiation therapy
Measurement-guided dose reconstruction has lately attracted significant attention because it can predict the delivered patient dose distribution. Although the treatment planning system (TPS) uses sophisticated algorithm to calculate the dose distribution, the calculation accuracy depends on the particular TPS used. This study aimed to investigate the relationship between the gamma passing rate (GPR) and the clinically relevant dose–volume index based on the predicted 3D patient dose distribution derived from two TPSs (XiO, RayStation). Twenty-one breast intensity-modulated radiation therapy plans were inversely optimized using XiO. With the same plans, both TPSs calculated the planned dose distribution. We conducted per-beam measurements on the coronal plane using a 2D array detector and analyzed the difference in 2D GPRs between the measured and planned doses by commercial software. Using in-house software, we calculated the predicted 3D patient dose distribution and derived the predicted 3D GPR, the predicted per-organ 3D GPR, and the predicted clinically relevant dose–volume indices [dose–volume histogram metrics and the value of the tumor-control probability/normal tissue complication probability of the planning target volume and organs at risk]. The results derived from XiO were compared with those from RayStation. While the mean 2D GPRs derived from both TPSs were 98.1% (XiO) and 100% (RayStation), the mean predicted 3D GPRs of ipsilateral lung (73.3% [XiO] and 85.9% [RayStation]; p < 0.001) had no correlation with 2D GPRs under the 3% global/3 mm criterion. Besides, this significant difference in terms of referenced TPS between XiO and RayStation could be explained by the fact that the error of predicted V5Gy of ipsilateral lung derived from XiO (29.6%) was significantly larger than that derived from RayStation (− 0.2%; p < 0.001). GPR is useful as a patient quality assurance to detect dosimetric errors; however, it does not necessarily contain detailed information on errors. Using the predicted clinically relevant dose–volume indices, the clinical interpretation of dosimetric errors can be obtained. We conclude that a clinically relevant dose–volume index based on the predicted 3D patient dose distribution could add to the clinical and biological considerations in the GPR, if we can guarantee the dose calculation accuracy of referenced TPS.
- 26 February 2019
- Published by Springer Nature in Radiation Oncology
- Vol. 14 (1) , 1-11
Open AccessComparison of gamma index based on dosimetric error and clinically relevant dose–volume index based on three-dimensional dose prediction in breast intensity-modulated radiation therapy
Measurement-guided dose reconstruction has lately attracted significant attention because it can predict the delivered patient dose distribution. Although the treatment planning system (TPS) uses sophisticated algorithm to calculate the dose distribution, the calculation accuracy depends on the particular TPS used. This study aimed to investigate the relationship between the gamma passing rate (GPR) and the clinically relevant dose–volume index based on the predicted 3D patient dose distribution derived from two TPSs (XiO, RayStation). Twenty-one breast intensity-modulated radiation therapy plans were inversely optimized using XiO. With the same plans, both TPSs calculated the planned dose distribution. We conducted per-beam measurements on the coronal plane using a 2D array detector and analyzed the difference in 2D GPRs between the measured and planned doses by commercial software. Using in-house software, we calculated the predicted 3D patient dose distribution and derived the predicted 3D GPR, the predicted per-organ 3D GPR, and the predicted clinically relevant dose–volume indices [dose–volume histogram metrics and the value of the tumor-control probability/normal tissue complication probability of the planning target volume and organs at risk]. The results derived from XiO were compared with those from RayStation. While the mean 2D GPRs derived from both TPSs were 98.1% (XiO) and 100% (RayStation), the mean predicted 3D GPRs of ipsilateral lung (73.3% [XiO] and 85.9% [RayStation]; p < 0.001) had no correlation with 2D GPRs under the 3% global/3 mm criterion. Besides, this significant difference in terms of referenced TPS between XiO and RayStation could be explained by the fact that the error of predicted V5Gy of ipsilateral lung derived from XiO (29.6%) was significantly larger than that derived from RayStation (− 0.2%; p < 0.001). GPR is useful as a patient quality assurance to detect dosimetric errors; however, it does not necessarily contain detailed information on errors. Using the predicted clinically relevant dose–volume indices, the clinical interpretation of dosimetric errors can be obtained. We conclude that a clinically relevant dose–volume index based on the predicted 3D patient dose distribution could add to the clinical and biological considerations in the GPR, if we can guarantee the dose calculation accuracy of referenced TPS.
- Open Access
- 27 November 2018
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 13 (11) , e0208086
A new plan quality objective function for determining optimal collimator combinations in prostate cancer treatment with stereotactic body radiation therapy using CyberKnife
Stereotactic body radiation therapy with CyberKnife for prostate cancer has long treatment times compared with conventional radiotherapy. This arises the need for designing treatment plans with short execution times. We propose an objective function for plan quality evaluation, which was used to determine an optimal combination between small and large collimators based on short treatment times and clinically acceptable dose distributions. Data from 11 prostate cancer patients were used. For each patient, 20 plans were created based on all combinations between one small (⌀ 10–25 mm) and one large (⌀ 35–60 mm) Iris collimator size. The objective function was assigned to each combination as a penalty, such that plans with low penalties were considered superior. This function considered the achievement of dosimetric planning goals, tumor control probability, normal tissue complication probability, relative seriality parameter, and treatment time. Two methods were used to determine the optimal combination. First, we constructed heat maps representing the mean penalty values and standard deviations of the plans created for each collimator combination. The combination giving a plan with the smallest mean penalty and standard deviation was considered optimal. Second, we created two groups of superior plans: group A plans were selected by histogram analysis and group B plans were selected by choosing the plan with the lowest penalty from each patient. In both groups, the most used small and large collimators were assumed to represent the optimal combination. The optimal combinations obtained from the heat maps included the 25 mm as a small collimator, giving small/large collimator sizes of 25/35, 25/40, 25/50, and 25/60 mm. The superior-group analysis indicated that 25/50 mm was the optimal combination. The optimal Iris combination for prostate cancer treatment using CyberKnife was determined to be a collimator size between 25 mm (small) and 50 mm (large).
- 27 November 2018
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 13 (11) , e0208086
Open AccessA new plan quality objective function for determining optimal collimator combinations in prostate cancer treatment with stereotactic body radiation therapy using CyberKnife
Stereotactic body radiation therapy with CyberKnife for prostate cancer has long treatment times compared with conventional radiotherapy. This arises the need for designing treatment plans with short execution times. We propose an objective function for plan quality evaluation, which was used to determine an optimal combination between small and large collimators based on short treatment times and clinically acceptable dose distributions. Data from 11 prostate cancer patients were used. For each patient, 20 plans were created based on all combinations between one small (⌀ 10–25 mm) and one large (⌀ 35–60 mm) Iris collimator size. The objective function was assigned to each combination as a penalty, such that plans with low penalties were considered superior. This function considered the achievement of dosimetric planning goals, tumor control probability, normal tissue complication probability, relative seriality parameter, and treatment time. Two methods were used to determine the optimal combination. First, we constructed heat maps representing the mean penalty values and standard deviations of the plans created for each collimator combination. The combination giving a plan with the smallest mean penalty and standard deviation was considered optimal. Second, we created two groups of superior plans: group A plans were selected by histogram analysis and group B plans were selected by choosing the plan with the lowest penalty from each patient. In both groups, the most used small and large collimators were assumed to represent the optimal combination. The optimal combinations obtained from the heat maps included the 25 mm as a small collimator, giving small/large collimator sizes of 25/35, 25/40, 25/50, and 25/60 mm. The superior-group analysis indicated that 25/50 mm was the optimal combination. The optimal Iris combination for prostate cancer treatment using CyberKnife was determined to be a collimator size between 25 mm (small) and 50 mm (large).
- Open Access
- 31 August 2018
- Published by Springer Nature in Radiation Oncology
- Vol. 13 (1) , 1-7
Mechanical performance of a commercial knowledge-based VMAT planning for prostate cancer
This study clarified the mechanical performance of volumetric modulated arc therapy (VMAT) plans for prostate cancer generated with a commercial knowledge-based treatment planning (KBP) and whether KBP system could be applied clinically without any major problems with mechanical performance. Thirty consecutive prostate cancer patients who underwent VMAT using extant clinical plans were evaluated. The mechanical performance and dosimetric accuracy of the single optimized KBPs, which were trained with other 51 clinical plans, were compared with the clinical plans. The mechanical performance metrics were mean field area (MFA), mean asymmetry distance (MAD), cross-axis score (CAS), closed leaf score (CLS), small aperture score (SAS), leaf travel (LT), modulation complexity score (MCSv), and monitor unit (MU). The γ passing rates were evaluated with ArcCheck and EBT3 film. The mean mechanical performance metrics (clinical plan vs. KBP) were as follows: 18.28 cm2 vs. 17.25 cm2 (MFA), 21.08 mm vs. 20.47 mm (MAD), 0.54 vs. 0.55 (CAS), 0.040 vs. 0.051 (CLS), 0.20 vs. 0.23 (SAS5mm), 458.5 mm vs. 418.8 mm (LT), 0.27 vs. 0.27 (MCSv), and 618.2 vs. 622.1 (MU), respectively. Significant differences were observed for CLS and LT. The average γ passing rates (clinical plan vs. KBP) were as follows: 99.0% vs. 99.1% (3%/3 mm) and 92.4% vs. 92.5% (2%/2 mm) with ArcCHeck, and 99.5% vs. 99.4% (3%/3 mm) and 95.2% vs. 95.4% (2%/2 mm) with EBT3 film, respectively. The KBP used lower multileaf collimator (MLC) travel and more closed or small MLC apertures than the clinical plan. The KBP system of VMAT for the prostate cancer was acceptable for clinical use without any major problems.
- 31 August 2018
- Published by Springer Nature in Radiation Oncology
- Vol. 13 (1) , 1-7
Open AccessMechanical performance of a commercial knowledge-based VMAT planning for prostate cancer
This study clarified the mechanical performance of volumetric modulated arc therapy (VMAT) plans for prostate cancer generated with a commercial knowledge-based treatment planning (KBP) and whether KBP system could be applied clinically without any major problems with mechanical performance. Thirty consecutive prostate cancer patients who underwent VMAT using extant clinical plans were evaluated. The mechanical performance and dosimetric accuracy of the single optimized KBPs, which were trained with other 51 clinical plans, were compared with the clinical plans. The mechanical performance metrics were mean field area (MFA), mean asymmetry distance (MAD), cross-axis score (CAS), closed leaf score (CLS), small aperture score (SAS), leaf travel (LT), modulation complexity score (MCSv), and monitor unit (MU). The γ passing rates were evaluated with ArcCheck and EBT3 film. The mean mechanical performance metrics (clinical plan vs. KBP) were as follows: 18.28 cm2 vs. 17.25 cm2 (MFA), 21.08 mm vs. 20.47 mm (MAD), 0.54 vs. 0.55 (CAS), 0.040 vs. 0.051 (CLS), 0.20 vs. 0.23 (SAS5mm), 458.5 mm vs. 418.8 mm (LT), 0.27 vs. 0.27 (MCSv), and 618.2 vs. 622.1 (MU), respectively. Significant differences were observed for CLS and LT. The average γ passing rates (clinical plan vs. KBP) were as follows: 99.0% vs. 99.1% (3%/3 mm) and 92.4% vs. 92.5% (2%/2 mm) with ArcCHeck, and 99.5% vs. 99.4% (3%/3 mm) and 95.2% vs. 95.4% (2%/2 mm) with EBT3 film, respectively. The KBP used lower multileaf collimator (MLC) travel and more closed or small MLC apertures than the clinical plan. The KBP system of VMAT for the prostate cancer was acceptable for clinical use without any major problems.
- Open Access
- 5 April 2018
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 13 (4) , e0195296
Dosimetric impact of intra-fraction prostate motion under a tumour-tracking system in hypofractionated robotic radiosurgery
For CyberKnife-mediated prostate cancer treatment, a tumour-tracking approach is applied to correct the target location by acquiring X-ray images of implanted fiducial markers intermittently. This study investigated the dosimetric impact of intra-fraction prostate motion during CyberKnife treatment. We retrospectively analyzed 16 patients treated using the CyberKnife (35 Gy delivered in five fractions). Using log files of recorded prostate motion, the intra-fraction prostate motion was simulated. We defined the worst-case intra-fraction prostate motion as the difference between pre- and post-deviation on log files and shifted structure sets according to the corresponding offsets for each beam. The dose–volume indices were calculated and compared with the original plan in terms of clinical target volume (CTV), planning target volume (CTV plus a 2-mm margin), rectum, bladder, and urethra. Prostate motions of >3, >5, and >10 mm were observed for 31.3, 9.1, and 0.5% of the 1929 timestamps, respectively. Relative differences between the simulated and original plans were mostly less than 1%. Although significant decreases were observed in D50% and D98% of the target, absolute dose differences were <0.1 Gy compared with the planned dose. The dosimetric impact of intra-fraction prostate motion may be small even with longer treatment durations, indicating that the tumour tracking using the CyberKnife could be a robust system for examining prostate motion.
- 5 April 2018
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 13 (4) , e0195296
Open AccessDosimetric impact of intra-fraction prostate motion under a tumour-tracking system in hypofractionated robotic radiosurgery
For CyberKnife-mediated prostate cancer treatment, a tumour-tracking approach is applied to correct the target location by acquiring X-ray images of implanted fiducial markers intermittently. This study investigated the dosimetric impact of intra-fraction prostate motion during CyberKnife treatment. We retrospectively analyzed 16 patients treated using the CyberKnife (35 Gy delivered in five fractions). Using log files of recorded prostate motion, the intra-fraction prostate motion was simulated. We defined the worst-case intra-fraction prostate motion as the difference between pre- and post-deviation on log files and shifted structure sets according to the corresponding offsets for each beam. The dose–volume indices were calculated and compared with the original plan in terms of clinical target volume (CTV), planning target volume (CTV plus a 2-mm margin), rectum, bladder, and urethra. Prostate motions of >3, >5, and >10 mm were observed for 31.3, 9.1, and 0.5% of the 1929 timestamps, respectively. Relative differences between the simulated and original plans were mostly less than 1%. Although significant decreases were observed in D50% and D98% of the target, absolute dose differences were <0.1 Gy compared with the planned dose. The dosimetric impact of intra-fraction prostate motion may be small even with longer treatment durations, indicating that the tumour tracking using the CyberKnife could be a robust system for examining prostate motion.
- Open Access
- 23 February 2018
- Published by Springer Nature in Radiation Oncology
- Vol. 13 (1) , 1-8
Impact of time-related factors on biologically accurate radiotherapy treatment planning
The incomplete repair (IR) model expresses the cell repair effect from radiation-induced damage over time, which is given little consideration in actual treatment planning. By incorporating the IR model into the normal tissue complication probability (NTCP), the accuracy and safety of treatment plan evaluations concerning the effect of repair can be improved. This study aims to evaluate the impact of incorporating the IR model into the NTCP by varying time-related factors such as the repair half-time (T1/2) and the junction-shift sc3hedule in craniospinal irradiation (CSI). CSI was planned retrospectively, and the NTCP of the spinal cord was calculated with the IR model for values of T1/2 from 1 to 10 h. The NTCP in the case of changing the junction-shift schedule was also examined in the same manner. The NTCP with the IR model increased with increasing T1/2, which is prominent for the larger T1/2. By changing the junction-shift schedule, the NTCP with the IR model decreased when adjacent fields overlapped. The IR model is a valuable addition to treatment planning because it enables the NTCP to be evaluated including the effect of repair and differences in scheduling to be reflected in the NTCP. However, these are largely dependent on the value of the T1/2.
- 23 February 2018
- Published by Springer Nature in Radiation Oncology
- Vol. 13 (1) , 1-8
Open AccessImpact of time-related factors on biologically accurate radiotherapy treatment planning
The incomplete repair (IR) model expresses the cell repair effect from radiation-induced damage over time, which is given little consideration in actual treatment planning. By incorporating the IR model into the normal tissue complication probability (NTCP), the accuracy and safety of treatment plan evaluations concerning the effect of repair can be improved. This study aims to evaluate the impact of incorporating the IR model into the NTCP by varying time-related factors such as the repair half-time (T1/2) and the junction-shift sc3hedule in craniospinal irradiation (CSI). CSI was planned retrospectively, and the NTCP of the spinal cord was calculated with the IR model for values of T1/2 from 1 to 10 h. The NTCP in the case of changing the junction-shift schedule was also examined in the same manner. The NTCP with the IR model increased with increasing T1/2, which is prominent for the larger T1/2. By changing the junction-shift schedule, the NTCP with the IR model decreased when adjacent fields overlapped. The IR model is a valuable addition to treatment planning because it enables the NTCP to be evaluated including the effect of repair and differences in scheduling to be reflected in the NTCP. However, these are largely dependent on the value of the T1/2.
- Open Access
- 14 December 2017
- Published by Oxford University Press (OUP) in Journal of Radiation Research
- Vol. 59 (2) , 164-172
Dosimetric and clinical effects of interfraction and intrafraction correlation errors during marker-based real-time tumor tracking for liver SBRT
Correlation model error (CME) between the internal target and the external surrogate, and marker–tumor correlation error (MTCE) between the tumor and the implanted marker occur during marker-based real-time tumor tracking. The effects of these intrafraction and interfraction errors on the dose coverage in the clinical target volume (CTV) and on tumor control probability (TCP) for hepatocellular carcinoma (HCC) were evaluated in this study. Eight HCC patients treated with non-isocentric dose delivery by a robotic radiosurgery system were enrolled. The CMEs were extracted from the treatment log file, and the MTCEs were calculated from the preceding study. The CMEs and MTCEs were randomly added to each beam’s robot position, and the changes in the TCP and the 2%, 95% and 99% dose coverage values for the CTV (D2, D95 and D99) were simulated. The data were statistically analyzed as a function of the CTV to planning target volume (PTV) margin, the dose fraction and the marker–tumor distance. Significant differences were observed in the majority of the CTV D2, D95 and D99 values and the TCP values. However, a linear regression revealed that ∆CTV D2, D95 and D99 have a weak correlation with ∆TCP. A dose-difference metric would be unable to detect a critical error for tumor control if the coverage changes for the CTV and ∆TCP were weakly correlated. Because the simulated TCP-based parameter determination was based on the dose simulation, including predicted interfraction and intrafraction errors, we concluded that a 95th percentile TCP-based parameter determination would be a robust strategy for ensuring tumor control while reducing doses to normal structures.
- 14 December 2017
- Published by Oxford University Press (OUP) in Journal of Radiation Research
- Vol. 59 (2) , 164-172
Open AccessDosimetric and clinical effects of interfraction and intrafraction correlation errors during marker-based real-time tumor tracking for liver SBRT
Correlation model error (CME) between the internal target and the external surrogate, and marker–tumor correlation error (MTCE) between the tumor and the implanted marker occur during marker-based real-time tumor tracking. The effects of these intrafraction and interfraction errors on the dose coverage in the clinical target volume (CTV) and on tumor control probability (TCP) for hepatocellular carcinoma (HCC) were evaluated in this study. Eight HCC patients treated with non-isocentric dose delivery by a robotic radiosurgery system were enrolled. The CMEs were extracted from the treatment log file, and the MTCEs were calculated from the preceding study. The CMEs and MTCEs were randomly added to each beam’s robot position, and the changes in the TCP and the 2%, 95% and 99% dose coverage values for the CTV (D2, D95 and D99) were simulated. The data were statistically analyzed as a function of the CTV to planning target volume (PTV) margin, the dose fraction and the marker–tumor distance. Significant differences were observed in the majority of the CTV D2, D95 and D99 values and the TCP values. However, a linear regression revealed that ∆CTV D2, D95 and D99 have a weak correlation with ∆TCP. A dose-difference metric would be unable to detect a critical error for tumor control if the coverage changes for the CTV and ∆TCP were weakly correlated. Because the simulated TCP-based parameter determination was based on the dose simulation, including predicted interfraction and intrafraction errors, we concluded that a 95th percentile TCP-based parameter determination would be a robust strategy for ensuring tumor control while reducing doses to normal structures.
- 3 November 2017
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 91 (1081) , 20160777
Strategies for reducing ovarian dose in volumetric modulated arc therapy (VMAT) for postoperative uterine cervical cancer
Objective: To reduce the ovarian dose with volumetric modulated arc therapy (VMAT), an original VMAT was designed with two types of arcs to restrict angles and fields (R-VMAT). Methods: The subjects were 11 patients who underwent ovarian transposition with clips left by a surgeon. Three methods, intensity-modulated radiotherapy (IMRT), standard VMAT (S-VMAT) and R-VMAT, were optimized for assessment of the ovarian dose with the target coverage kept high. Results: The homogeneity and conformity indexes for the planning target volume (PTV) were similar for the three methods. However, the average ± SD of the ovarian mean dose (OMD) was 5.0 ± 1.5, 4.9 ± 1.9 and 3.5 ± 1.4 Gy, and the percentage of ovarian volume exceeding 5 Gy (V5) was 41.5 ± 34.1%, 34.1 ± 38.05% and 8.4 ± 20.5% for IMRT, S-VMAT and R-VMAT, respectively. The OMD and V5 were significantly smaller for R-VMAT than for the other plans (p < 0.01). Correlation values between the OMD and the lateral distance from the ovaries to the PTV surface were 0.86, 0.81 and 0.82 for IMRT, S-VMAT and R-VMAT, respectively. Conclusion: These findings suggest that R-VMAT delivered the lowest dose to the ovaries. To reduce the OMD to less than 3 Gy, ovaries should be transposed laterally 6.1 cm away from the PTV surface when R-VMAT is used. Advances in knowledge: When organs with high susceptibility to radiation, such as ovaries, are near the PTV, R-VMAT is superior to IMRT and S-VMAT.
- 3 November 2017
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 91 (1081) , 20160777
Strategies for reducing ovarian dose in volumetric modulated arc therapy (VMAT) for postoperative uterine cervical cancer
Objective: To reduce the ovarian dose with volumetric modulated arc therapy (VMAT), an original VMAT was designed with two types of arcs to restrict angles and fields (R-VMAT). Methods: The subjects were 11 patients who underwent ovarian transposition with clips left by a surgeon. Three methods, intensity-modulated radiotherapy (IMRT), standard VMAT (S-VMAT) and R-VMAT, were optimized for assessment of the ovarian dose with the target coverage kept high. Results: The homogeneity and conformity indexes for the planning target volume (PTV) were similar for the three methods. However, the average ± SD of the ovarian mean dose (OMD) was 5.0 ± 1.5, 4.9 ± 1.9 and 3.5 ± 1.4 Gy, and the percentage of ovarian volume exceeding 5 Gy (V5) was 41.5 ± 34.1%, 34.1 ± 38.05% and 8.4 ± 20.5% for IMRT, S-VMAT and R-VMAT, respectively. The OMD and V5 were significantly smaller for R-VMAT than for the other plans (p < 0.01). Correlation values between the OMD and the lateral distance from the ovaries to the PTV surface were 0.86, 0.81 and 0.82 for IMRT, S-VMAT and R-VMAT, respectively. Conclusion: These findings suggest that R-VMAT delivered the lowest dose to the ovaries. To reduce the OMD to less than 3 Gy, ovaries should be transposed laterally 6.1 cm away from the PTV surface when R-VMAT is used. Advances in knowledge: When organs with high susceptibility to radiation, such as ovaries, are near the PTV, R-VMAT is superior to IMRT and S-VMAT.