  • How does the content of the 20th I.S.P.O. World Congress align with the United Nations Sustainable Development Goals?

    by David F. Rusaw, Alix Chadwell, Liselotte Hermansson, Han Houdijk, Anton G. Johannesson, Peter Kyberd, Rune Nilsen, Pia Nolstedt, Dick Plettenburg, Erik Prinsen, et al.

  • Open Access

    Perception and control of low cable operation forces in voluntary closing body-powered upper-limb prostheses

    by Mona Hichert, David A Abbink, Alistair N Vardy, Corry K Van Der Sluis, Wim G M Janssen, Michael A H Brouwers, Dick H Plettenburg

    Operating a body-powered prosthesis can be painful and tiring due to high cable operation forces, illustrating that low cable operation forces are a desirable design property for body-powered prostheses. However, lower operation forces might negatively affect controllability and force perception, which is plausible but not known. This study aims to quantify the accuracy of cable force perception and control for body-powered prostheses in a low cable operation force range by utilizing isometric and dynamic force reproduction experiments. Twenty-five subjects with trans-radial absence conducted two force reproduction tasks; first an isometric task of reproducing 10, 15, 20, 25, 30 or 40 N and second a force reproduction task of 10 and 20 N, for cable excursions of 10, 20, 40, 60 and 80 mm. Task performance was quantified by the force reproduction error and the variability in the generated force. The results of the isometric experiment demonstrated that increasing force levels enlarge the force variability, but do not influence the force reproduction error for the tested force range. The second experiment showed that increased cable excursions resulted in a decreased force reproduction error, for both tested force levels, whereas the force variability remained unchanged. In conclusion, the design recommendations for voluntary closing body-powered prostheses suggested by this study are to minimize cable operation forces: this does not affect force reproduction error but does reduce force variability. Furthermore, increased cable excursions facilitate users with additional information to meet a target force more accurately.


  • Open Access

    Functional evaluation of a non-assembly 3D-printed hand prosthesis

    by Juan Sebastian Cuellar, Gerwin Smit, Paul Breedveld, Amir Abbas Zadpoor, Dick Plettenburg

    In developing countries, the access of amputees to prosthetic devices is very limited. In a way to increase accessibility of prosthetic hands, we have recently developed a new approach for the design and 3D printing of non-assembly active hand prostheses using inexpensive 3D printers working on the basis of material extrusion technology. This article describes the design of our novel 3D-printed hand prosthesis and also shows the mechanical and functional evaluation in view of its future use in developing countries. We have fabricated a hand prosthesis using 3D printing technology and a non-assembly design approach that reaches certain level of functionality. The mechanical resistance of critical parts, the mechanical performance, and the functionality of a non-assembly 3D-printed hand prosthesis were assessed. The mechanical configuration used in the hand prosthesis is able to withstand typical actuation forces delivered by prosthetic users. Moreover, the activation forces and the energy required for a closing cycle are considerably lower as compared to other body-powered prostheses. The non-assembly design achieved a comparable level of functionality with respect to other body-powered alternatives. We consider this prosthetic hand a valuable option for people with arm defects in developing countries.


  • Open Access

    Simplifying models and estimating grasp performance for comparing dynamic hand orthosis concepts

    by Ronald A. Bos, Dick H. Plettenburg, Just L. Herder

    While designing a dynamic hand orthosis to assist during activities of daily living, the designer has to know whether a concept will have sufficient grasp performance to support these activities. This is often estimated by measuring the interaction force at the contact interface. However, this requires a prototyping step and limits the practicality of comparing several concepts in an early design stage. Alternatively, this study presents and compares basic static and dynamic models to numerically estimate grasp performance. This was applied on an exemplary concept for a hydraulically operated hand orthosis grasping a circular object. The models were validated with an experimental set-up that does not require sensors at the contact interface. Static and dynamic model results were almost identical, where the static model could be around 10 times faster and is generally more robust to a high contact stiffness. Both models were unable to make accurate quantitative predictions, which is believed to be due to differences in used contact stiffness. However, the models were able to make correct qualitative comparisons, making it a valid method to compare and choose concepts in an early design stage.

  • Open Access

    Design of an Electrohydraulic Hand Orthosis for People with Duchenne Muscular Dystrophy Using Commercially Available Components

    by Ronald A. Bos, Kostas Nizamis, Dick H. Plettenburg, Just L. Herder

    People with Duchenne muscular dystrophy are currently in need of assistive robotics to improve their hand function and have a better quality of life. However, none of the available active hand orthoses is able to address to their specific needs. In this study, the use of hydraulic technology is proposed in the design of an active hand orthosis. Commercially available components were used to identify where customization is necessary for a new electrohydraulic hand orthosis. The presented prototype was able to move four finger modules with a single actuator. The finger modules were separable and had a total mass of only 150 g, whereas the valve manifold added another 250 g. Results revealed that the prototype was able to function well with full flexion/extension cycles up to 2 Hz, but with hysteretic losses between 37-81% of the total input energy. Specialized valves and slave cylinders are required to increase efficiency at higher speeds and to obtain more robust sealing performance.


  • Additive manufacturing of non-assembly mechanisms

    by Juan Sebastian Cuellar, Gerwin Smit, Dick Plettenburg, Amir Zadpoor


  • Open Access

    Fatigue-free operation of most body-powered prostheses not feasible for majority of users with trans-radial deficiency

    by Mona Hichert, Alistair N Vardy, Dick Plettenburg

    Y users’ maximum cable operation force and to relate this to the fatigue-free force range for the use of body-powered prostheses. Study design: Experimental trial. Methods: In total, 23 subjects with trans-radial deficiencies used a bypass prosthesis to exert maximum cable force three times during 3 s and reported discomfort or pain on a body map. Additionally, subjects’ anthropometric measures were taken to relate to maximum force. Results: Subjects generated forces ranging from 87 to 538 N. Of the 23 subjects, 12 generated insufficient maximum cable force to operate 8 of the 10 body-powered prostheses fatigue free. Discomfort or pain did not correlate with the magnitude of maximum force achieved by the subjects. Nine subjects indicated discomfort or pain. No relationships between anthropometry and maximal forces were found except for maximum cable forces and the affected upper-arm circumference for females. Conclusion: For a majority of subjects, the maximal cable force was lower than acceptable for fatigue-free prosthesis use. Discomfort or pain occurred in ~40% of the subjects, suggesting a suboptimal force transmission mechanism. Clinical relevance The physical strength of users determines whether a body-powered prosthesis is suitable for comfortable, fatigue-free long-duration use on a daily basis. High cable operation forces can provoke discomfort and pain for some users, mainly in the armpit. Prediction of the users’ strength by anthropometric measures might assist the choice of a suitable prosthesis....


  • Open Access

    Ipsilateral Scapular Cutaneous Anchor System

    by Mona Hichert, Dick H. Plettenburg

    Body-powered prosthesis users frequently complain about the poor cosmesis and comfort of the traditional shoulder harness. The Ipsilateral Scapular Cutaneous Anchor System offers an alternative, but it remains unclear to what extent it affects the perception and control of cable operation forces compared to the traditional shoulder harness. To compare cable force perception and control with the figure-of-nine harness versus the Ipsilateral Scapular Cutaneous Anchor System and to investigate force perception and control at different force levels. Experimental trial. Ten male able-bodied subjects completed a cable force reproduction task at four force levels in the range of 10–40 N using the figure-of-nine harness and the Anchor System. Perception and control of cable operating forces were quantified by the force reproduction error and the force variability. In terms of force reproduction error and force variability, the subjects did not behave differently when using the two systems. The smallest force reproduction error and force variability were found at the smallest target force level of 10 N. The Anchor System performs no differently than the traditional figure-of-nine harness in terms of force perception and control, making it a viable alternative. Furthermore, users perceive and control low operation forces better than high forces. The Ipsilateral Scapular Cutaneous Anchor System offers an alternative for the traditional harness in terms of cable operation force perception and control and should therefore be considered for clinical use. Low cable operation forces increase the perception and control abilities of users.