Kenneth K. C. Lee
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Kenneth K. C. Lee has a total of 44 co-authors. Here are the top co-authors by number of shared publications:
- Victor Xiao Dong Yang
Ryerson Univ. (Canada)
13 shared publications Adrian Mariampillai
Biophotonics and Bioengineering Laboratory, Dept. Electrical and Computer Engineering, Ryerson University, 350 Victoria St. Toronto, ON, M5B2K3 Canada
10 shared publicationsBeau A. Standish
Ryerson Univ. (Canada)
9 shared publicationsBarry Vuong
Ryerson Univ. (Canada)
5 shared publicationsCuiru Sun
Ryerson Univ. (Canada)
5 shared publications- I. Alex Vitkin
Department of Medical Biophysics, University of Toronto, Toronto, ON, Canada
4 shared publications
Latest Publications
- 8 March 2013
- Published by SPIE-Intl Soc Optical Eng
- Vol. 8565, 85654S
Blood flow velocity measurement by endovascular Doppler optical coherence tomography
Blood flow velocity and volumetric flow measurements are important parameters for assessment of the severity of stenosis and the outcome of interventional therapy. However, feasibility of intravascular flow measurement using a rotational catheter based phase resolved Doppler optical coherence tomography (DOCT) is difficult. Motion artefacts induced by the rotating optical imaging catheter, and the radially dependent noise background of measured Doppler signals are the main challenges encountered. In this study, a custom-made data acquisition system and developed algorithms to remove non-uniform rotational distortion (NURD) induced phase shift artefact by tracking the phase shift observed on catheter sheath. The flow velocity is calculated from Doppler shift obtained by Kasai autocorrelation after motion artefact removal. Blood flow velocity profiles in porcine carotid arteries in vivo were obtained at 100 frames/s with 500 A-lines/frame and DOCT images were taken at 20 frames/s with 2500 A-lines/frame. Time-varying velocity profiles were obtained at an artery branch. Furthermore, the identification of a vein adjacent to the catheterized vessel based on the color Doppler signal was also observed. The absolute measurement of intravascular flow using a rotating fiber catheter can provide insights to different stages of interventional treatment of stenosis in carotid artery.
- 8 March 2013
- Published by SPIE-Intl Soc Optical Eng
- Vol. 8565, 85654S
Blood flow velocity measurement by endovascular Doppler optical coherence tomography
Blood flow velocity and volumetric flow measurements are important parameters for assessment of the severity of stenosis and the outcome of interventional therapy. However, feasibility of intravascular flow measurement using a rotational catheter based phase resolved Doppler optical coherence tomography (DOCT) is difficult. Motion artefacts induced by the rotating optical imaging catheter, and the radially dependent noise background of measured Doppler signals are the main challenges encountered. In this study, a custom-made data acquisition system and developed algorithms to remove non-uniform rotational distortion (NURD) induced phase shift artefact by tracking the phase shift observed on catheter sheath. The flow velocity is calculated from Doppler shift obtained by Kasai autocorrelation after motion artefact removal. Blood flow velocity profiles in porcine carotid arteries in vivo were obtained at 100 frames/s with 500 A-lines/frame and DOCT images were taken at 20 frames/s with 2500 A-lines/frame. Time-varying velocity profiles were obtained at an artery branch. Furthermore, the identification of a vein adjacent to the catheterized vessel based on the color Doppler signal was also observed. The absolute measurement of intravascular flow using a rotating fiber catheter can provide insights to different stages of interventional treatment of stenosis in carotid artery.
- Open Access
- 18 September 2012
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 3 (10) , 2600-2610
In vivo feasibility of endovascular Doppler optical coherence tomography
Feasibility of detecting intravascular flow using a catheter based endovascular optical coherence tomography (OCT) system is demonstrated in a porcine carotid model in vivo. The effects of A-line density, radial distance, signal-to-noise ratio, non-uniform rotational distortion (NURD), phase stability of the swept wavelength laser and interferometer system on Doppler shift detection limit were investigated in stationary and flow phantoms. Techniques for NURD induced phase shift artifact removal were developed by tracking the catheter sheath. Detection of high flow velocity (~51 cm/s) present in the porcine carotid artery was obtained by phase unwrapping techniques and compared to numerical simulation, taking into consideration flow profile distortion by the eccentrically positioned imaging catheter. Using diluted blood in saline mixture as clearing agent, simultaneous Doppler OCT imaging of intravascular flow and structural OCT imaging of the carotid artery wall was feasible. To our knowledge, this is the first in vivo demonstration of Doppler imaging and absolute measurement of intravascular flow using a rotating fiber catheter in carotid artery.
- 18 September 2012
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 3 (10) , 2600-2610
Open AccessIn vivo feasibility of endovascular Doppler optical coherence tomography
Feasibility of detecting intravascular flow using a catheter based endovascular optical coherence tomography (OCT) system is demonstrated in a porcine carotid model in vivo. The effects of A-line density, radial distance, signal-to-noise ratio, non-uniform rotational distortion (NURD), phase stability of the swept wavelength laser and interferometer system on Doppler shift detection limit were investigated in stationary and flow phantoms. Techniques for NURD induced phase shift artifact removal were developed by tracking the catheter sheath. Detection of high flow velocity (~51 cm/s) present in the porcine carotid artery was obtained by phase unwrapping techniques and compared to numerical simulation, taking into consideration flow profile distortion by the eccentrically positioned imaging catheter. Using diluted blood in saline mixture as clearing agent, simultaneous Doppler OCT imaging of intravascular flow and structural OCT imaging of the carotid artery wall was feasible. To our knowledge, this is the first in vivo demonstration of Doppler imaging and absolute measurement of intravascular flow using a rotating fiber catheter in carotid artery.
- Open Access
- 7 June 2012
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 3 (7) , 1557-1564
Real-time speckle variance swept-source optical coherence tomography using a graphics processing unit
Advances in swept source laser technology continues to increase the imaging speed of swept-source optical coherence tomography (SS-OCT) systems. These fast imaging speeds are ideal for microvascular detection schemes, such as speckle variance (SV), where interframe motion can cause severe imaging artifacts and loss of vascular contrast. However, full utilization of the laser scan speed has been hindered by the computationally intensive signal processing required by SS-OCT and SV calculations. Using a commercial graphics processing unit that has been optimized for parallel data processing, we report a complete high-speed SS-OCT platform capable of real-time data acquisition, processing, display, and saving at 108,000 lines per second. Subpixel image registration of structural images was performed in real-time prior to SV calculations in order to reduce decorrelation from stationary structures induced by the bulk tissue motion. The viability of the system was successfully demonstrated in a high bulk tissue motion scenario of human fingernail root imaging where SV images (512 × 512 pixels, n = 4) were displayed at 54 frames per second.
- 7 June 2012
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 3 (7) , 1557-1564
Open AccessReal-time speckle variance swept-source optical coherence tomography using a graphics processing unit
Advances in swept source laser technology continues to increase the imaging speed of swept-source optical coherence tomography (SS-OCT) systems. These fast imaging speeds are ideal for microvascular detection schemes, such as speckle variance (SV), where interframe motion can cause severe imaging artifacts and loss of vascular contrast. However, full utilization of the laser scan speed has been hindered by the computationally intensive signal processing required by SS-OCT and SV calculations. Using a commercial graphics processing unit that has been optimized for parallel data processing, we report a complete high-speed SS-OCT platform capable of real-time data acquisition, processing, display, and saving at 108,000 lines per second. Subpixel image registration of structural images was performed in real-time prior to SV calculations in order to reduce decorrelation from stationary structures induced by the bulk tissue motion. The viability of the system was successfully demonstrated in a high bulk tissue motion scenario of human fingernail root imaging where SV images (512 × 512 pixels, n = 4) were displayed at 54 frames per second.
- Open Access
- 16 May 2012
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 3 (6) , 1404-1412
Intraoperative handheld optical coherence tomography forward-viewing probe: physical performance and preliminary animal imaging
A prototype intraoperative hand-held optical coherence tomography (OCT) imaging probe was developed to provide micron resolution cross-sectional images of subsurface tissue during open surgery. This new ergonomic probe was designed based on electrostatically driven optical fibers, and packaged into a catheter probe in the form factor of clinically accepted Bayonet shaped neurosurgical probes. Optical properties of the probe were measured to have a ~20 μm spot size, 5 mm working distance and 4 mm field of view. Feasibility of this probe for structural and Doppler shift imaging was tested on porcine femoral blood vessel imaging.
- 16 May 2012
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 3 (6) , 1404-1412
Open AccessIntraoperative handheld optical coherence tomography forward-viewing probe: physical performance and preliminary animal imaging
A prototype intraoperative hand-held optical coherence tomography (OCT) imaging probe was developed to provide micron resolution cross-sectional images of subsurface tissue during open surgery. This new ergonomic probe was designed based on electrostatically driven optical fibers, and packaged into a catheter probe in the form factor of clinically accepted Bayonet shaped neurosurgical probes. Optical properties of the probe were measured to have a ~20 μm spot size, 5 mm working distance and 4 mm field of view. Feasibility of this probe for structural and Doppler shift imaging was tested on porcine femoral blood vessel imaging.
- Open Access
- 10 April 2012
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 3 (5) , 911-919
Speckle variance optical coherence tomography of the rodent spinal cord: in vivo feasibility
Optical coherence tomography (OCT) has the combined advantage of high temporal (µsec) and spatial (in vivo OCT imaging model of the rodent spinal cord. In this study we image the microvascular networks of both rats and mice using speckle variance OCT. This is the first report of depth resolved imaging of the in vivo spinal cord using an entirely endogenous contrast mechanism.
- 10 April 2012
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 3 (5) , 911-919
Open AccessSpeckle variance optical coherence tomography of the rodent spinal cord: in vivo feasibility
Optical coherence tomography (OCT) has the combined advantage of high temporal (µsec) and spatial (in vivo OCT imaging model of the rodent spinal cord. In this study we image the microvascular networks of both rats and mice using speckle variance OCT. This is the first report of depth resolved imaging of the in vivo spinal cord using an entirely endogenous contrast mechanism.
- 9 February 2012
- Published by SPIE-Intl Soc Optical Eng
- Vol. 8230, 823002
Measuring intracellular motion using dynamic light scattering with optical coherence tomography in a mouse tumor model
We present, for the first time an in vivo implementation of dynamic light scattering (DLS) adapted to optical coherence tomography (OCT). Human bladder carcinoma tumors were grown in dorsal skin-fold window chambers fitted to male nude mice and imaged at a rate of 200 Hz using OCT. Maps of speckle decorrelation times (DT) were generated for regions of skin from individual mice as well as for regions containing tumor tissue before and after treatment with chemotherapy. Variations in DT were found between individual mice exhibiting different skin anatomy (primarily due to deterioration from the window chamber implantation). A significant difference in DT was also observed between tumor regions and surrounding normal tissue. Finally, maps of DT generated for tumor tissue treated with chemotherapy indicated a drop in DT at 24 and 48 hours after treatment. These preliminary results suggest the feasibility of using DLSOCT to measure intracellular motion as an endogenous contrast mechanism in vivo.
- 9 February 2012
- Published by SPIE-Intl Soc Optical Eng
- Vol. 8230, 823002
Measuring intracellular motion using dynamic light scattering with optical coherence tomography in a mouse tumor model
We present, for the first time an in vivo implementation of dynamic light scattering (DLS) adapted to optical coherence tomography (OCT). Human bladder carcinoma tumors were grown in dorsal skin-fold window chambers fitted to male nude mice and imaged at a rate of 200 Hz using OCT. Maps of speckle decorrelation times (DT) were generated for regions of skin from individual mice as well as for regions containing tumor tissue before and after treatment with chemotherapy. Variations in DT were found between individual mice exhibiting different skin anatomy (primarily due to deterioration from the window chamber implantation). A significant difference in DT was also observed between tumor regions and surrounding normal tissue. Finally, maps of DT generated for tumor tissue treated with chemotherapy indicated a drop in DT at 24 and 48 hours after treatment. These preliminary results suggest the feasibility of using DLSOCT to measure intracellular motion as an endogenous contrast mechanism in vivo.
- 3 February 2012
- Published by SPIE-Intl Soc Optical Eng
- Vol. 8207, 82074V-82074V-8
Neurosurgical hand-held optical coherence tomography (OCT) forward-viewing probe
- 3 February 2012
- Published by SPIE-Intl Soc Optical Eng
- Vol. 8207, 82074V-82074V-8
Neurosurgical hand-held optical coherence tomography (OCT) forward-viewing probe
- Open Access
- 31 January 2012
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 3 (3) , 388-399
Endovascular optical coherence tomography intensity kurtosis: visualization of vasa vasorum in porcine carotid artery
Application of speckle variance optical coherence tomography (OCT) to endovascular imaging faces difficulty of extensive motion artifacts inherently associated with arterial pulsations in addition to other physiological movements. In this study, we employed a technique involving a fourth order statistical method, kurtosis, operating on the endovascular OCT intensity images to visualize the vasa vasorum of carotid artery in vivo and identify its flow dynamic in a porcine model. The intensity kurtosis technique can distinguish vasa vasorum from the surrounding tissues in the presence of extensive time varying noises and dynamic motions of the arterial wall. Imaging of vasa vasorum and its proliferation, may compliment the growing knowledge of structural endovascular OCT in assessment and treatment of atherosclerosis in coronary and carotid arteries.
- 31 January 2012
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 3 (3) , 388-399
Open AccessEndovascular optical coherence tomography intensity kurtosis: visualization of vasa vasorum in porcine carotid artery
Application of speckle variance optical coherence tomography (OCT) to endovascular imaging faces difficulty of extensive motion artifacts inherently associated with arterial pulsations in addition to other physiological movements. In this study, we employed a technique involving a fourth order statistical method, kurtosis, operating on the endovascular OCT intensity images to visualize the vasa vasorum of carotid artery in vivo and identify its flow dynamic in a porcine model. The intensity kurtosis technique can distinguish vasa vasorum from the surrounding tissues in the presence of extensive time varying noises and dynamic motions of the arterial wall. Imaging of vasa vasorum and its proliferation, may compliment the growing knowledge of structural endovascular OCT in assessment and treatment of atherosclerosis in coronary and carotid arteries.
- 11 February 2010
- Published by SPIE-Intl Soc Optical Eng
- p. 755418-755418-6
Simultaneous 6-channel optical coherence tomography using a high-power telescope-less polygon-based swept laser in dual-amplifier configuration
Multichannel optical coherence tomography (MOCT) imaging is demonstrated using a high-power wavelength-swept laser source. The main benefit of MOCT is faster image acquisition rates without a corresponding increase in the laser tuning speed. The wavelength-swept laser was constructed using a compact telescope-less polygon-based filter in Littman arrangement. High output power, necessary for MOCT, was achieved by incorporating two serial semiconductor optical amplifiers in a ring laser cavity in Fourier domain mode-locked configuration. The laser has a measured wavelength tuning range of 111 nm centered at 1329 nm, coherence length of 5.5 mm, and total average output power of 131 mW at 43 kHz sweeping rate. Using this laser, a six-channel imaging system was constructed. The imaging arm consisted of a multi-fiber push-on connector mounted on a galvanometer-based scanner. All channels, spaced 250 μm apart, were focused at the same depth. Six-channel OCT imaging to achieve 258 kHz scan rate is demonstrated. The increase in effective frame rate using multichannel acquisition may be beneficial for 3-dimensional in-vivo imaging where bulk tissue motion can adversely affect the image quality.
- 11 February 2010
- Published by SPIE-Intl Soc Optical Eng
- p. 755418-755418-6
Simultaneous 6-channel optical coherence tomography using a high-power telescope-less polygon-based swept laser in dual-amplifier configuration
Multichannel optical coherence tomography (MOCT) imaging is demonstrated using a high-power wavelength-swept laser source. The main benefit of MOCT is faster image acquisition rates without a corresponding increase in the laser tuning speed. The wavelength-swept laser was constructed using a compact telescope-less polygon-based filter in Littman arrangement. High output power, necessary for MOCT, was achieved by incorporating two serial semiconductor optical amplifiers in a ring laser cavity in Fourier domain mode-locked configuration. The laser has a measured wavelength tuning range of 111 nm centered at 1329 nm, coherence length of 5.5 mm, and total average output power of 131 mW at 43 kHz sweeping rate. Using this laser, a six-channel imaging system was constructed. The imaging arm consisted of a multi-fiber push-on connector mounted on a galvanometer-based scanner. All channels, spaced 250 μm apart, were focused at the same depth. Six-channel OCT imaging to achieve 258 kHz scan rate is demonstrated. The increase in effective frame rate using multichannel acquisition may be beneficial for 3-dimensional in-vivo imaging where bulk tissue motion can adversely affect the image quality.