Sang-Woo Jeon
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Sang-Woo Jeon has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
- Chong-Hyuk Choi
Arthroscopy and Joint Research Institute, Yonsei University College of Medicine, Seoul, Republic of Korea
3 shared publications - Min Jung
Arthroscopy and Joint Research Institute, Yonsei University College of Medicine, Seoul, Republic of Korea
3 shared publications - Sung-Jae Kim
Arthroscopy and Joint Research Institute, Yonsei University College of Medicine, Seoul, Republic of Korea
3 shared publications - Kang-Il Kim
Department of Orthopaedic Surgery, Kyung Hee University Hospital at Gangdong, Seoul, Republic of Korea
2 shared publications - Sang Jun Song
Department of Orthopaedic Surgery, Kyung Hee University College of Medicine, Kyung Hee University Medical Center, Seoul, Korea
2 shared publications - Sung-Hwan Kim
Yonsei University Health System, Republic of Korea
2 shared publications
Latest Publications
- Open Access
Particulated Costal Hyaline Cartilage Allograft and Microdrilling Combined with High Tibial Osteotomy Improves Early Pain Outcomes in Patients Suffering from Medial Knee Osteoarthritis with Full-Thickness Cartilage Defects: A Randomized Controlled Trial
Background and Objectives: While particulated costal hyaline cartilage allograft (PCHCA) combined with microdrilling demonstrates superior cartilage regeneration compared to microdrilling alone in high tibial osteotomy (HTO), the impact on early clinical recovery remains uncertain. The aim of this study is to compare early clinical outcomes (within 6 months) between microdrilling alone versus combined particulated costal hyaline cartilage allograft (PCHCA) with microdrilling in medial open-wedge high tibial osteotomy (MOWHTO) for medial compartment osteoarthritis, and to investigate age-related differences in treatment response. Materials and Methods: This prospective, dual-center, randomized controlled trial with blinded outcome assessment enrolled 64 patients (33 treatment and 31 control) undergoing MOWHTO with medial femoral condyle cartilage defects (ICRS III-IV, ≥200 mm2). The treatment group received PCHCA implantation combined with microdrilling, while the control group received microdrilling alone. Patients and outcome assessors were blinded to group allocation. Primary outcomes were KOOS-Pain and VAS scores at 12 and 24 weeks. Age-stratified analysis compared patients ≤ 60 years (n = 44) versus > 60 years (n = 20) Results: The treatment group showed significantly superior KOOS-Pain scores at 12 weeks (70.6 vs. 61.6, p = 0.014) and 24 weeks (82.9 vs. 71.5, p = 0.011), with corresponding VAS improvements (p = 0.010 and p = 0.004). Age-stratified analysis revealed patients ≤ 60 years achieved comparable outcomes regardless of treatment (p = 0.574), while patients > 60 years demonstrated significantly superior outcomes with PCHCA (KOOS-Pain improvement: 24.7 vs. 17.9 points, p = 0.012). BMI ≥ 26 kg/m2 significantly predicted reduced odds of achieving MCID for both pain (OR 0.88, p = 0.028) and ADL (OR 0.80, p = 0.003). Conclusions: PCHCA combined with microdrilling provides superior early pain relief compared to microdrilling alone in MOWHTO, with effects most pronounced in patients > 60 years. Age-stratified treatment selection and BMI optimization should be considered to maximize outcomes.
Open AccessParticulated Costal Hyaline Cartilage Allograft and Microdrilling Combined with High Tibial Osteotomy Improves Early Pain Outcomes in Patients Suffering from Medial Knee Osteoarthritis with Full-Thickness Cartilage Defects: A Randomized Controlled Trial
Background and Objectives: While particulated costal hyaline cartilage allograft (PCHCA) combined with microdrilling demonstrates superior cartilage regeneration compared to microdrilling alone in high tibial osteotomy (HTO), the impact on early clinical recovery remains uncertain. The aim of this study is to compare early clinical outcomes (within 6 months) between microdrilling alone versus combined particulated costal hyaline cartilage allograft (PCHCA) with microdrilling in medial open-wedge high tibial osteotomy (MOWHTO) for medial compartment osteoarthritis, and to investigate age-related differences in treatment response. Materials and Methods: This prospective, dual-center, randomized controlled trial with blinded outcome assessment enrolled 64 patients (33 treatment and 31 control) undergoing MOWHTO with medial femoral condyle cartilage defects (ICRS III-IV, ≥200 mm2). The treatment group received PCHCA implantation combined with microdrilling, while the control group received microdrilling alone. Patients and outcome assessors were blinded to group allocation. Primary outcomes were KOOS-Pain and VAS scores at 12 and 24 weeks. Age-stratified analysis compared patients ≤ 60 years (n = 44) versus > 60 years (n = 20) Results: The treatment group showed significantly superior KOOS-Pain scores at 12 weeks (70.6 vs. 61.6, p = 0.014) and 24 weeks (82.9 vs. 71.5, p = 0.011), with corresponding VAS improvements (p = 0.010 and p = 0.004). Age-stratified analysis revealed patients ≤ 60 years achieved comparable outcomes regardless of treatment (p = 0.574), while patients > 60 years demonstrated significantly superior outcomes with PCHCA (KOOS-Pain improvement: 24.7 vs. 17.9 points, p = 0.012). BMI ≥ 26 kg/m2 significantly predicted reduced odds of achieving MCID for both pain (OR 0.88, p = 0.028) and ADL (OR 0.80, p = 0.003). Conclusions: PCHCA combined with microdrilling provides superior early pain relief compared to microdrilling alone in MOWHTO, with effects most pronounced in patients > 60 years. Age-stratified treatment selection and BMI optimization should be considered to maximize outcomes.
- Open Access
- 31 July 2025
- Published by Korean Society of Animal Science and Technology in Journal of Animal Science and Technology
- Vol. 67 (4) , 853-867
Effects of polyphosphates with different chain lengths on digestive organ weight, carcass quality, and immune response, and intestinal microflora in broilers
Journal of Animal Science and Technology (JAST) is a peer-reviewed, open access journal publishing original research, review articles and notes in all fields of animal science. Topics covered by the journal include: genetics and breeding, physiology, nutrition of monogastric animals, nutrition of ruminants, animal products (milk, meat, eggs and their by-products) and their processing, grasslands and roughages, livestock environment, animal biotechnology, animal behavior and welfare.
- 31 July 2025
- Published by Korean Society of Animal Science and Technology in Journal of Animal Science and Technology
- Vol. 67 (4) , 853-867
Open AccessEffects of polyphosphates with different chain lengths on digestive organ weight, carcass quality, and immune response, and intestinal microflora in broilers
Journal of Animal Science and Technology (JAST) is a peer-reviewed, open access journal publishing original research, review articles and notes in all fields of animal science. Topics covered by the journal include: genetics and breeding, physiology, nutrition of monogastric animals, nutrition of ruminants, animal products (milk, meat, eggs and their by-products) and their processing, grasslands and roughages, livestock environment, animal biotechnology, animal behavior and welfare.
- Open Access
Optimal Tunnel Positioning and Graft Diameter to Minimize Impingement in Single-Bundle ACL Reconstruction: A 3D CT Simulation Analysis
Background and Objectives: Graft impingement against the intercondylar notch has been identified as a significant contributor to graft deterioration and suboptimal outcomes following anterior cruciate ligament (ACL) reconstruction. This study aimed to (1) identify the optimal combination of tunnel positions that minimizes impingement between the ACL graft and femoral intercondylar notch. Materials and Methods: Three-dimensional models of nine normal knees were reconstructed using computed tomography scans obtained at four knee flexion angles (0°, 45°, 90°, and 120°). Virtual ACL grafts with diameters of 7 mm and 9 mm were modeled as cylinders. Nine graft configurations were investigated by varying femoral and tibial footprint locations (anteromedial, central, and posterolateral) in all possible combinations. For each configuration, impingement volume was quantified by measuring the overlap between the intercondylar notch and the virtual graft using Boolean operators in 3D simulation software. The effects of graft diameter, footprint location, and knee flexion angle on impingement volume were analyzed. Results: Maximum impingement volumes were observed at 0° knee extension, with significant reductions at 45° flexion (p < 0.01) and negligible impingement at 90° and 120° flexion. The 9 mm diameter grafts demonstrated significantly greater impingement volumes than 7 mm grafts (p < 0.01). Impingement volumes increased progressively as footprint locations shifted from posterolateral to anteromedial positions in both femoral and tibial components. However, statistically significant differences in impingement volume across footprint locations were observed only for tibial positioning (p < 0.001), not for femoral positioning (p > 0.05). The femoral anteromedial-tibial anteromedial configuration exhibited the highest impingement volume (577.8 ± 171.3 mm3 for 9 mm grafts), while the femoral posterolateral-tibial posterolateral configuration showed the lowest (73.5 ± 85.6 mm3). Conclusions: Tunnel position, graft diameter, and knee flexion angle significantly influence impingement risk in ACL reconstruction. Tibial tunnel position appears more critical than femoral position in minimizing graft impingement. Posterolateral positioning of tunnels, particularly on the tibial side, may reduce impingement volume. Clinical Relevance: This study provides quantitative evidence to guide surgeons in optimizing tunnel placement and graft selection for anatomical single-bundle ACL reconstruction, potentially reducing the risk of graft deterioration and failure due to mechanical impingement.
Open AccessOptimal Tunnel Positioning and Graft Diameter to Minimize Impingement in Single-Bundle ACL Reconstruction: A 3D CT Simulation Analysis
Background and Objectives: Graft impingement against the intercondylar notch has been identified as a significant contributor to graft deterioration and suboptimal outcomes following anterior cruciate ligament (ACL) reconstruction. This study aimed to (1) identify the optimal combination of tunnel positions that minimizes impingement between the ACL graft and femoral intercondylar notch. Materials and Methods: Three-dimensional models of nine normal knees were reconstructed using computed tomography scans obtained at four knee flexion angles (0°, 45°, 90°, and 120°). Virtual ACL grafts with diameters of 7 mm and 9 mm were modeled as cylinders. Nine graft configurations were investigated by varying femoral and tibial footprint locations (anteromedial, central, and posterolateral) in all possible combinations. For each configuration, impingement volume was quantified by measuring the overlap between the intercondylar notch and the virtual graft using Boolean operators in 3D simulation software. The effects of graft diameter, footprint location, and knee flexion angle on impingement volume were analyzed. Results: Maximum impingement volumes were observed at 0° knee extension, with significant reductions at 45° flexion (p < 0.01) and negligible impingement at 90° and 120° flexion. The 9 mm diameter grafts demonstrated significantly greater impingement volumes than 7 mm grafts (p < 0.01). Impingement volumes increased progressively as footprint locations shifted from posterolateral to anteromedial positions in both femoral and tibial components. However, statistically significant differences in impingement volume across footprint locations were observed only for tibial positioning (p < 0.001), not for femoral positioning (p > 0.05). The femoral anteromedial-tibial anteromedial configuration exhibited the highest impingement volume (577.8 ± 171.3 mm3 for 9 mm grafts), while the femoral posterolateral-tibial posterolateral configuration showed the lowest (73.5 ± 85.6 mm3). Conclusions: Tunnel position, graft diameter, and knee flexion angle significantly influence impingement risk in ACL reconstruction. Tibial tunnel position appears more critical than femoral position in minimizing graft impingement. Posterolateral positioning of tunnels, particularly on the tibial side, may reduce impingement volume. Clinical Relevance: This study provides quantitative evidence to guide surgeons in optimizing tunnel placement and graft selection for anatomical single-bundle ACL reconstruction, potentially reducing the risk of graft deterioration and failure due to mechanical impingement.
- Open Access
- 2 May 2025
- Published by MDPI AG in Preprints.org
Optimal Tunnel Positioning and Graft Diameter to Minimize Impingement in Single-Bundle ACL Reconstruction: A 3D CT Simulation Analysis
Background and Objectives: Graft impingement against the intercondylar notch has been identified as a significant contributor to graft deterioration and suboptimal outcomes following anterior cruciate ligament (ACL) reconstruction. This study aimed to (1) identify the optimal combination of tunnel positions that minimizes impingement between the ACL graft and femoral intercondylar notch. Materials and Methods: Three-dimensional models of nine normal knees were reconstructed using computed tomography scans obtained at four knee flexion angles (0°, 45°, 90° and 120°). Virtual ACL grafts with diameters of 7 mm and 9 mm were modeled as cylinders. Nine graft configurations were investigated by varying femoral and tibial footprint locations (anteromedial, central, and posterolateral) in all possible combinations. For each configuration, impingement volume was quantified by measuring the overlap between the intercondylar notch and the virtual graft using Boolean operators in 3D simulation software. The effects of graft diameter, footprint location, and knee flexion angle on impingement volume were analyzed. Results: Maximum impingement volumes were observed at 0° knee extension, with significant reductions at 45° flexion (PConclusion: Tunnel position, graft diameter, and knee flexion angle significantly influence impingement risk in ACL reconstruction. Tibial tunnel position appears more critical than femoral position in minimizing graft impingement. Posterolateral positioning of tunnels, particularly on the tibial side, may reduce impingement volume. Clinical Relevance: This study provides quantitative evidence to guide surgeons in optimizing tunnel placement and graft selection for anatomical single-bundle ACL reconstruction, potentially reducing the risk of graft deterioration and failure due to mechanical impingement.
- 2 May 2025
- Published by MDPI AG in Preprints.org
Open AccessOptimal Tunnel Positioning and Graft Diameter to Minimize Impingement in Single-Bundle ACL Reconstruction: A 3D CT Simulation Analysis
Background and Objectives: Graft impingement against the intercondylar notch has been identified as a significant contributor to graft deterioration and suboptimal outcomes following anterior cruciate ligament (ACL) reconstruction. This study aimed to (1) identify the optimal combination of tunnel positions that minimizes impingement between the ACL graft and femoral intercondylar notch. Materials and Methods: Three-dimensional models of nine normal knees were reconstructed using computed tomography scans obtained at four knee flexion angles (0°, 45°, 90° and 120°). Virtual ACL grafts with diameters of 7 mm and 9 mm were modeled as cylinders. Nine graft configurations were investigated by varying femoral and tibial footprint locations (anteromedial, central, and posterolateral) in all possible combinations. For each configuration, impingement volume was quantified by measuring the overlap between the intercondylar notch and the virtual graft using Boolean operators in 3D simulation software. The effects of graft diameter, footprint location, and knee flexion angle on impingement volume were analyzed. Results: Maximum impingement volumes were observed at 0° knee extension, with significant reductions at 45° flexion (PConclusion: Tunnel position, graft diameter, and knee flexion angle significantly influence impingement risk in ACL reconstruction. Tibial tunnel position appears more critical than femoral position in minimizing graft impingement. Posterolateral positioning of tunnels, particularly on the tibial side, may reduce impingement volume. Clinical Relevance: This study provides quantitative evidence to guide surgeons in optimizing tunnel placement and graft selection for anatomical single-bundle ACL reconstruction, potentially reducing the risk of graft deterioration and failure due to mechanical impingement.
- 6 August 2024
- Published by Springer Nature in Archives of orthopaedic and trauma surgery
- Vol. 144 (8) , 3523-3532
The optimal measurement method considering reliability and validity in the anterior knee laxity of anterior cruciate ligament tears
Introduction To seek an optimal measurement method with high reliability and high validity for evaluation of the anterior knee laxity on stress radiographs and comparing the translation values to those of KT-2000 arthrometer. Methods Anterior knee laxity in 77 patients was measured preoperatively using the TelosTM and the KT-2000 arthrometer. Side-to-side difference measurements were taken using three conventional measuring methods and one proposed method (Modified Lateral). The knee position on the stress radiograph was evaluated and scored based on the stress radiograph qualifying criteria depending on stress film correctiveness. Intraclass correlation coefficients were analyzed to evaluate the reliability of the measurement methods and were compared between high (Group H) and low (Group L) radiograph quality score groups for each method. Validity was assessed by comparing the KT-2000 and the TelosTM using Pearson correlation (r value). Results The Modified Lateral method showed the best Intraclass Correlation Coefficients (ICCs), followed by Center to Center, and Medial to Medial and Lateral to Lateral methods without considering the quality of Telos. In the comparison between groups based on Telos quality for intra-rater reliability, the Medial to Medial (MM) method demonstrated the best reliability in both groups (MM: ICCs, Group H = 0.942, Group L = 0.917, P = 0.693). As for inter-rater reliability, the Modified Lateral (ML) method exhibited the best reliability in both groups (ML: ICCs, Group H = 0.923, Group L = 0.882, P = 0.547). The value measured using the ML method in Telos showed the highest correlation coefficient with the KT-2000 measured value in both groups H and L. There were no statistically significant differences among the correlation coefficient values. Conclusion The Modified Lateral method is recommended for its high reliability, taking into account the differences in bilateral knee positions and anatomical discriminability on stress radiographs when evaluating anterior knee translation with Telos. It also best reflected the KT-2000 arthrometer. Level of evidence : Case Series, Level IV.
- 6 August 2024
- Published by Springer Nature in Archives of orthopaedic and trauma surgery
- Vol. 144 (8) , 3523-3532
The optimal measurement method considering reliability and validity in the anterior knee laxity of anterior cruciate ligament tears
Introduction To seek an optimal measurement method with high reliability and high validity for evaluation of the anterior knee laxity on stress radiographs and comparing the translation values to those of KT-2000 arthrometer. Methods Anterior knee laxity in 77 patients was measured preoperatively using the TelosTM and the KT-2000 arthrometer. Side-to-side difference measurements were taken using three conventional measuring methods and one proposed method (Modified Lateral). The knee position on the stress radiograph was evaluated and scored based on the stress radiograph qualifying criteria depending on stress film correctiveness. Intraclass correlation coefficients were analyzed to evaluate the reliability of the measurement methods and were compared between high (Group H) and low (Group L) radiograph quality score groups for each method. Validity was assessed by comparing the KT-2000 and the TelosTM using Pearson correlation (r value). Results The Modified Lateral method showed the best Intraclass Correlation Coefficients (ICCs), followed by Center to Center, and Medial to Medial and Lateral to Lateral methods without considering the quality of Telos. In the comparison between groups based on Telos quality for intra-rater reliability, the Medial to Medial (MM) method demonstrated the best reliability in both groups (MM: ICCs, Group H = 0.942, Group L = 0.917, P = 0.693). As for inter-rater reliability, the Modified Lateral (ML) method exhibited the best reliability in both groups (ML: ICCs, Group H = 0.923, Group L = 0.882, P = 0.547). The value measured using the ML method in Telos showed the highest correlation coefficient with the KT-2000 measured value in both groups H and L. There were no statistically significant differences among the correlation coefficient values. Conclusion The Modified Lateral method is recommended for its high reliability, taking into account the differences in bilateral knee positions and anatomical discriminability on stress radiographs when evaluating anterior knee translation with Telos. It also best reflected the KT-2000 arthrometer. Level of evidence : Case Series, Level IV.
- Open Access
- 10 February 2023
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 12 (4) , 1439
A Comparative Study on Outcomes of Partial Meniscectomy for Horizontal Cleavage Tear of Medial Meniscus: Complete versus Partial Resection of Inferior Leaf
The extent to which resection of unstable leaf should be performed in horizontal cleavage meniscus tear has not yet been elucidated. The purpose of this study was to compare the clinical outcomes of partial meniscectomy for horizontal cleavage tear of medial meniscus between complete resection of inferior leaf including the periphery up to the joint capsule and partial resection leaving stable peripheral torn meniscal tissue. A total of 126 patients who underwent partial meniscectomy for horizontal cleavage tear of medial meniscus were divided into two groups: group C (n = 34), treated with the complete resection of the inferior leaf; and group P (n = 92), treated with partial resection of the inferior leaf. The minimum follow-up duration was 3 years. Functional outcomes were evaluated using the Lysholm knee scoring scale, International Knee Documentation Committee (IKDC) subjective knee evaluation form, and knee injury and osteoarthritis outcome score (KOOS). Radiologic assessments were performed using the IKDC radiographic assessment scale and measurement of the height of the joint space in the medial compartment of the tibiofemoral joint. The functional outcomes including the Lysholm knee, IKDC subjective score, activities of daily living and sport and recreation subscale of KOOS were worse in group C than in group P (p < 0.001). The radiologic outcomes including postoperative IKDC radiographic scale (p = 0.003) and the postoperative joint space on the affected side (p < 0.001) were also worse in group C than in group P. In the horizontal cleavage tear of medial meniscus, complete resection of the inferior leaf including the periphery up to the joint capsule showed inferior clinical outcomes compared with partial resection leaving stable peripheral rim of torn meniscus at minimum 3-year follow-up. If the peripheral part of the inferior leaf is stable in horizontal cleavage tear of medial meniscus, partial resection of the inferior leaf preserving peripheral rim can be recommended.
- 10 February 2023
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 12 (4) , 1439
Open AccessA Comparative Study on Outcomes of Partial Meniscectomy for Horizontal Cleavage Tear of Medial Meniscus: Complete versus Partial Resection of Inferior Leaf
The extent to which resection of unstable leaf should be performed in horizontal cleavage meniscus tear has not yet been elucidated. The purpose of this study was to compare the clinical outcomes of partial meniscectomy for horizontal cleavage tear of medial meniscus between complete resection of inferior leaf including the periphery up to the joint capsule and partial resection leaving stable peripheral torn meniscal tissue. A total of 126 patients who underwent partial meniscectomy for horizontal cleavage tear of medial meniscus were divided into two groups: group C (n = 34), treated with the complete resection of the inferior leaf; and group P (n = 92), treated with partial resection of the inferior leaf. The minimum follow-up duration was 3 years. Functional outcomes were evaluated using the Lysholm knee scoring scale, International Knee Documentation Committee (IKDC) subjective knee evaluation form, and knee injury and osteoarthritis outcome score (KOOS). Radiologic assessments were performed using the IKDC radiographic assessment scale and measurement of the height of the joint space in the medial compartment of the tibiofemoral joint. The functional outcomes including the Lysholm knee, IKDC subjective score, activities of daily living and sport and recreation subscale of KOOS were worse in group C than in group P (p < 0.001). The radiologic outcomes including postoperative IKDC radiographic scale (p = 0.003) and the postoperative joint space on the affected side (p < 0.001) were also worse in group C than in group P. In the horizontal cleavage tear of medial meniscus, complete resection of the inferior leaf including the periphery up to the joint capsule showed inferior clinical outcomes compared with partial resection leaving stable peripheral rim of torn meniscus at minimum 3-year follow-up. If the peripheral part of the inferior leaf is stable in horizontal cleavage tear of medial meniscus, partial resection of the inferior leaf preserving peripheral rim can be recommended.
- 7 August 2019
- Published by Georg Thieme Verlag KG in The Journal of Knee Surgery
- Vol. 34 (02) , 178-186
Factors Related to Meniscal Extrusion and Cartilage Lesions in Medial Meniscus Root Tears
The purpose of this study was to identify factors affecting medial meniscus extrusion and cartilage degeneration in medial meniscus root tears (MMRT) and to determine the optimal cut-off values for the factors that predict disease severity. We retrospectively evaluated 86 consecutive patients diagnosed with an isolated MMRT by magnetic resonance imaging (MRI) examinations and arthroscopic procedures for 2 years. Patient-specific factors such as age, sex, the time between injury and MRI (mTIME), the time between injury and surgery (sTIME), the time between MRI and surgery (dTIME), Kellgren–Lawrence (KL) grades, and the mechanical tibiofemoral axis angle (mTFA) were documented. Regression analyses and receiver operating characteristic (ROC) curve analyses were performed. The mTIME was only positively correlated with meniscal extrusion (r = 0.425, p < 0.001). The patients who had grades 3 and 4 cartilage lesions had only significantly higher KL grades and longer sTIME than the patients who had lower grades of cartilage lesion (6.5 months [interquartile range (IQ): 3.0–12.0) vs. 2.5 months [IQ: 0.9–3.9]; p < 0.001). The cut-off value of mTIME and sTIME were 2.5 and 6 months. Relapse times greater than 2.5 months and 6 months after a specific event were associated with a 7.8-fold increased risk for meniscus extrusion and an 18.2-fold increased risk for cartilage lesions, respectively. The risk of medial extrusion of the meniscus and the severity of articular cartilage lesions increased with time after an injury. The period of time from 2.5 to 6 months after traumatic event might be a critical window for intervention in the patients with MMRT to perform the repair in the status which the meniscus did not extrude more than 3 mm and the cartilage lesion did not progress more than grade 3. This study is a retrospective and uncontrolled case series and reflects level IV of evidence.
- 7 August 2019
- Published by Georg Thieme Verlag KG in The Journal of Knee Surgery
- Vol. 34 (02) , 178-186
Factors Related to Meniscal Extrusion and Cartilage Lesions in Medial Meniscus Root Tears
The purpose of this study was to identify factors affecting medial meniscus extrusion and cartilage degeneration in medial meniscus root tears (MMRT) and to determine the optimal cut-off values for the factors that predict disease severity. We retrospectively evaluated 86 consecutive patients diagnosed with an isolated MMRT by magnetic resonance imaging (MRI) examinations and arthroscopic procedures for 2 years. Patient-specific factors such as age, sex, the time between injury and MRI (mTIME), the time between injury and surgery (sTIME), the time between MRI and surgery (dTIME), Kellgren–Lawrence (KL) grades, and the mechanical tibiofemoral axis angle (mTFA) were documented. Regression analyses and receiver operating characteristic (ROC) curve analyses were performed. The mTIME was only positively correlated with meniscal extrusion (r = 0.425, p < 0.001). The patients who had grades 3 and 4 cartilage lesions had only significantly higher KL grades and longer sTIME than the patients who had lower grades of cartilage lesion (6.5 months [interquartile range (IQ): 3.0–12.0) vs. 2.5 months [IQ: 0.9–3.9]; p < 0.001). The cut-off value of mTIME and sTIME were 2.5 and 6 months. Relapse times greater than 2.5 months and 6 months after a specific event were associated with a 7.8-fold increased risk for meniscus extrusion and an 18.2-fold increased risk for cartilage lesions, respectively. The risk of medial extrusion of the meniscus and the severity of articular cartilage lesions increased with time after an injury. The period of time from 2.5 to 6 months after traumatic event might be a critical window for intervention in the patients with MMRT to perform the repair in the status which the meniscus did not extrude more than 3 mm and the cartilage lesion did not progress more than grade 3. This study is a retrospective and uncontrolled case series and reflects level IV of evidence.
- 1 August 2019
- Published by Elsevier in The Journal of Arthroplasty
- Vol. 34 (8) , 1656-1661
Robot-Assisted Total Knee Arthroplasty Does Not Improve Long-Term Clinical and Radiologic Outcomes
- 1 August 2019
- Published by Elsevier in The Journal of Arthroplasty
- Vol. 34 (8) , 1656-1661
Robot-Assisted Total Knee Arthroplasty Does Not Improve Long-Term Clinical and Radiologic Outcomes
- 15 June 2019
- Published by Elsevier in The Journal of Arthroplasty
- Vol. 34 (10) , 2521-2522
Response to Letter to the Editor on “Robot-Assisted Total Knee Arthroplasty Does Not Improve Long-Term Clinical and Radiologic Outcomes”
- 15 June 2019
- Published by Elsevier in The Journal of Arthroplasty
- Vol. 34 (10) , 2521-2522
Response to Letter to the Editor on “Robot-Assisted Total Knee Arthroplasty Does Not Improve Long-Term Clinical and Radiologic Outcomes”