Ulrich Katscher
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Ulrich Katscher has a total of 107 co-authors. Here are the top co-authors by number of shared publications:
Peter Börnert
Philips Research Hamburg Germany
7 shared publicationsChristian Findeklee
Philips Research Europe, Hamburg, Germany
4 shared publicationsKay Nehrke
Department of Tomographic Imaging Systems, Philips Research, Hamburg, Germany
4 shared publications- Khin Khin Tha
Laboratory for Biomarker Imaging Science, Graduate School of Biomedical Science and Engineering, Hokkaido University, N15 W7, Kita-ku, Sapporo 060-8638, Japan
4 shared publications - Olaf Dössel
Institute of Biomedical Engineering, Karlsruhe Institute of Technology (KIT), Karlsruhe, Germany
4 shared publications Peter Vernickel
Department of Tomographic Imaging Systems, Philips Research, Hamburg, Germany
4 shared publications
Latest Publications
- Open Access
- 7 March 2026
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 63 (5) , 1224-1245
Clinical Applications of Electrical Conductivity Imaging Using MRI
Magnetic resonance imaging (MRI) has emerged as a noninvasive technique for probing the electrical properties of biological tissues: electrical conductivity and relative permittivity. This review focuses on the electrical conductivity and provides a comprehensive overview of applications across both low‐ and high‐frequency regimes. At low frequencies (below 1 MHz), conductivity mapping primarily reflects tissue microstructure and ionic composition. In contrast, at high frequencies (around 100 MHz), tissue conductivity primarily reflects ionic composition. First, we summarize the theoretical foundations, technical developments, and reconstruction algorithms that underpin conductivity imaging, highlighting advances in magnetic resonance electrical impedance tomography, current density imaging, and electrical properties tomography. The main part of the article discusses preclinical and clinical applications, demonstrating the potential and possible roles of conductivity imaging in clinical settings, along with current challenges and emerging applications. Finally, we outline future directions toward integrating conductivity imaging into routine MRI protocols, with the potential to enhance diagnostic precision and therapeutic monitoring. Evidence Level: 1. Technical Efficacy: Stage 3.
- 7 March 2026
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 63 (5) , 1224-1245
Open AccessClinical Applications of Electrical Conductivity Imaging Using MRI
Magnetic resonance imaging (MRI) has emerged as a noninvasive technique for probing the electrical properties of biological tissues: electrical conductivity and relative permittivity. This review focuses on the electrical conductivity and provides a comprehensive overview of applications across both low‐ and high‐frequency regimes. At low frequencies (below 1 MHz), conductivity mapping primarily reflects tissue microstructure and ionic composition. In contrast, at high frequencies (around 100 MHz), tissue conductivity primarily reflects ionic composition. First, we summarize the theoretical foundations, technical developments, and reconstruction algorithms that underpin conductivity imaging, highlighting advances in magnetic resonance electrical impedance tomography, current density imaging, and electrical properties tomography. The main part of the article discusses preclinical and clinical applications, demonstrating the potential and possible roles of conductivity imaging in clinical settings, along with current challenges and emerging applications. Finally, we outline future directions toward integrating conductivity imaging into routine MRI protocols, with the potential to enhance diagnostic precision and therapeutic monitoring. Evidence Level: 1. Technical Efficacy: Stage 3.
- Open Access
- 16 January 2026
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 63 (4) , 1204-1207
Standardization of MR Electrical Properties Tomography: A Guideline From the ISMRM Electro‐Magnetic Tissue Properties Study Group
- 16 January 2026
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 63 (4) , 1204-1207
Open AccessStandardization of MR Electrical Properties Tomography: A Guideline From the ISMRM Electro‐Magnetic Tissue Properties Study Group
- 23 December 2025
- Published by Wiley in NMR in Biomedicine
- Vol. 39 (2) , e70218
Noninvasive Electrical Conductivity Mapping by MRI: Its Diagnostic Potential in Distinguishing Thoracic Lesions
Electric properties tomography (EPT) enables noninvasive quantification of tissue electrical conductivity ( σ ), offering potential biomarkers for tissue characterization. However, the technical feasibility and diagnostic utility of phase‐based EPT in thoracic applications remain limited. This study presents a comprehensive evaluation of phase‐based EPT for thoracic lesion characterization. Twenty patients with focal lung or mediastinal lesions underwent 1.5T MRI including sagittal two‐dimensional steady‐state free precession imaging for EPT reconstruction and diffusion‐weighted imaging for comparison. σ maps were successfully reconstructed using phase‐based methods, with histogram and texture analysis performed to extract quantitative features. Following multicollinearity assessment using variance inflation factor analysis, five independent predictors were identified: three σ ‐derived features (entropy, kurtosis, and joint energy) and two apparent diffusion coefficient (ADC)‐derived features (10th percentile and contrast). The σ ‐based and ADC‐based diagnostic indices achieved comparable performance with area under the curve (AUC) values of 0.869 (95% confidence interval [CI]: 0.650–1) and 0.893 (95% CI: 0.742–1), respectively. Two‐dimensional clustering analysis revealed that adenocarcinoma demonstrated significantly higher complexity in the combined σ ‐ADC parameter space [cluster number: 10.5 (6.8–13.3)] compared with squamous cell carcinoma [4.5 (4.0–5.8); p = 0.003] and benign lesions [6.5 (6.0–7.0); p = 0.014]. These findings demonstrate that σ measurements provide complementary information to ADC for lesion characterization. Importantly, σ measurements showed robustness to lesion anatomical location, indicating the technical reliability of the phase‐based EPT approach in thoracic imaging.
- 23 December 2025
- Published by Wiley in NMR in Biomedicine
- Vol. 39 (2) , e70218
Noninvasive Electrical Conductivity Mapping by MRI: Its Diagnostic Potential in Distinguishing Thoracic Lesions
Electric properties tomography (EPT) enables noninvasive quantification of tissue electrical conductivity ( σ ), offering potential biomarkers for tissue characterization. However, the technical feasibility and diagnostic utility of phase‐based EPT in thoracic applications remain limited. This study presents a comprehensive evaluation of phase‐based EPT for thoracic lesion characterization. Twenty patients with focal lung or mediastinal lesions underwent 1.5T MRI including sagittal two‐dimensional steady‐state free precession imaging for EPT reconstruction and diffusion‐weighted imaging for comparison. σ maps were successfully reconstructed using phase‐based methods, with histogram and texture analysis performed to extract quantitative features. Following multicollinearity assessment using variance inflation factor analysis, five independent predictors were identified: three σ ‐derived features (entropy, kurtosis, and joint energy) and two apparent diffusion coefficient (ADC)‐derived features (10th percentile and contrast). The σ ‐based and ADC‐based diagnostic indices achieved comparable performance with area under the curve (AUC) values of 0.869 (95% confidence interval [CI]: 0.650–1) and 0.893 (95% CI: 0.742–1), respectively. Two‐dimensional clustering analysis revealed that adenocarcinoma demonstrated significantly higher complexity in the combined σ ‐ADC parameter space [cluster number: 10.5 (6.8–13.3)] compared with squamous cell carcinoma [4.5 (4.0–5.8); p = 0.003] and benign lesions [6.5 (6.0–7.0); p = 0.014]. These findings demonstrate that σ measurements provide complementary information to ADC for lesion characterization. Importantly, σ measurements showed robustness to lesion anatomical location, indicating the technical reliability of the phase‐based EPT approach in thoracic imaging.
- Open Access
- 20 August 2025
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 63 (1) , 279-281
MR Electrical Properties Tomography Acquisitions: A Guideline From the ISMRM Electro‐Magnetic Tissue Properties Study Group
- 20 August 2025
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 63 (1) , 279-281
Open AccessMR Electrical Properties Tomography Acquisitions: A Guideline From the ISMRM Electro‐Magnetic Tissue Properties Study Group
- 21 August 2024
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 61 (3) , 1188-1189
Editorial for “Effect of Ethanol on Brain Electrical Tissue Conductivity in Social Drinkers”
- 21 August 2024
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 61 (3) , 1188-1189
Editorial for “Effect of Ethanol on Brain Electrical Tissue Conductivity in Social Drinkers”
- 18 October 2023
- Published by Elsevier in Magnetic Resonance Imaging
- Vol. 105, 10-16
Estimation of effective b-value for a diffusion-weighted double-echo steady-state sequence with bipolar gradients
- 18 October 2023
- Published by Elsevier in Magnetic Resonance Imaging
- Vol. 105, 10-16
Estimation of effective b-value for a diffusion-weighted double-echo steady-state sequence with bipolar gradients
- 6 July 2023
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 59 (4) , 1229-1230
Editorial for “Problem Solving MRI to Reduce False‐Positive Biopsy Related to Breast US: Conductivity vs DWI vs Abbreviated Contrast‐Enhanced MRI”
- 6 July 2023
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 59 (4) , 1229-1230
Editorial for “Problem Solving MRI to Reduce False‐Positive Biopsy Related to Breast US: Conductivity vs DWI vs Abbreviated Contrast‐Enhanced MRI”
- Open Access
- 16 May 2023
- Published by MDPI AG in Tomography
- Vol. 9 (3) , 1029-1040
Quantitative Assessment of Intervertebral Disc Composition by MRI: Sensitivity to Diurnal Variation
Whether diurnal variation exists in quantitative MRI indices such as the T1rho relaxation time (T1ρ) of the intervertebral disc (IVD) is yet to be explored. This prospective study aimed to evaluate the diurnal variation in T1ρ, apparent diffusion coefficient (ADC), and electrical conductivity (σ) of lumbar IVD and its relationship with other MRI or clinical indices. Lumbar spine MRI, including T1ρ imaging, diffusion-weighted imaging (DWI), and electric properties tomography (EPT), was conducted on 17 sedentary workers twice (morning and evening) on the same day. The T1ρ, ADC, and σ of IVD were compared between the time points. Their diurnal variation, if any, was tested for correlation with age, body mass index (BMI), IVD level, Pfirrmann grade, scan interval, and diurnal variation in IVD height index. The results showed a significant decrease in T1ρ and ADC and a significant increase in the σ of IVD in the evening. T1ρ variation had a weak correlation with age and scan interval, and ADC variation with scan interval. Diurnal variation exists for the T1ρ, ADC, and σ of lumbar IVD, which should be accounted for in image interpretation. This variation is thought to be due to diurnal variations in intradiscal water, proteoglycan, and sodium ion concentration.
- 16 May 2023
- Published by MDPI AG in Tomography
- Vol. 9 (3) , 1029-1040
Open AccessQuantitative Assessment of Intervertebral Disc Composition by MRI: Sensitivity to Diurnal Variation
Whether diurnal variation exists in quantitative MRI indices such as the T1rho relaxation time (T1ρ) of the intervertebral disc (IVD) is yet to be explored. This prospective study aimed to evaluate the diurnal variation in T1ρ, apparent diffusion coefficient (ADC), and electrical conductivity (σ) of lumbar IVD and its relationship with other MRI or clinical indices. Lumbar spine MRI, including T1ρ imaging, diffusion-weighted imaging (DWI), and electric properties tomography (EPT), was conducted on 17 sedentary workers twice (morning and evening) on the same day. The T1ρ, ADC, and σ of IVD were compared between the time points. Their diurnal variation, if any, was tested for correlation with age, body mass index (BMI), IVD level, Pfirrmann grade, scan interval, and diurnal variation in IVD height index. The results showed a significant decrease in T1ρ and ADC and a significant increase in the σ of IVD in the evening. T1ρ variation had a weak correlation with age and scan interval, and ADC variation with scan interval. Diurnal variation exists for the T1ρ, ADC, and σ of lumbar IVD, which should be accounted for in image interpretation. This variation is thought to be due to diurnal variations in intradiscal water, proteoglycan, and sodium ion concentration.
- Open Access
- 17 February 2023
- Published by MDPI AG in Tomography
- Vol. 9 (1) , 420-435
Repeatability and Reproducibility Uncertainty in Magnetic Resonance-Based Electric Properties Tomography of a Homogeneous Phantom
Uncertainty assessment is a fundamental step in quantitative magnetic resonance imaging because it makes comparable, in a strict metrological sense, the results of different scans, for example during a longitudinal study. Magnetic resonance-based electric properties tomography (EPT) is a quantitative imaging technique that retrieves, non-invasively, a map of the electric properties inside a human body. Although EPT has been used in some early clinical studies, a rigorous experimental assessment of the associated uncertainty has not yet been performed. This paper aims at evaluating the repeatability and reproducibility uncertainties in phase-based Helmholtz-EPT applied on homogeneous phantom data acquired with a clinical 3 T scanner. The law of propagation of uncertainty is used to evaluate the uncertainty in the estimated conductivity values starting from the uncertainty in the acquired scans, which is quantified through a robust James–Stein shrinkage estimator to deal with the dimensionality of the problem. Repeatable errors are detected in the estimated conductivity maps and are quantified for various values of the tunable parameters of the EPT implementation. The spatial dispersion of the estimated electric conductivity maps is found to be a good approximation of the reproducibility uncertainty, evaluated by changing the position of the phantom after each scan. The results underpin the use of the average conductivity (calculated by weighting the local conductivity values by their uncertainty and taking into account the spatial correlation) as an estimate of the conductivity of the homogeneous phantom.
- 17 February 2023
- Published by MDPI AG in Tomography
- Vol. 9 (1) , 420-435
Open AccessRepeatability and Reproducibility Uncertainty in Magnetic Resonance-Based Electric Properties Tomography of a Homogeneous Phantom
Uncertainty assessment is a fundamental step in quantitative magnetic resonance imaging because it makes comparable, in a strict metrological sense, the results of different scans, for example during a longitudinal study. Magnetic resonance-based electric properties tomography (EPT) is a quantitative imaging technique that retrieves, non-invasively, a map of the electric properties inside a human body. Although EPT has been used in some early clinical studies, a rigorous experimental assessment of the associated uncertainty has not yet been performed. This paper aims at evaluating the repeatability and reproducibility uncertainties in phase-based Helmholtz-EPT applied on homogeneous phantom data acquired with a clinical 3 T scanner. The law of propagation of uncertainty is used to evaluate the uncertainty in the estimated conductivity values starting from the uncertainty in the acquired scans, which is quantified through a robust James–Stein shrinkage estimator to deal with the dimensionality of the problem. Repeatable errors are detected in the estimated conductivity maps and are quantified for various values of the tunable parameters of the EPT implementation. The spatial dispersion of the estimated electric conductivity maps is found to be a good approximation of the reproducibility uncertainty, evaluated by changing the position of the phantom after each scan. The results underpin the use of the average conductivity (calculated by weighting the local conductivity values by their uncertainty and taking into account the spatial correlation) as an estimate of the conductivity of the homogeneous phantom.
- 23 April 2022
- Published by Springer Nature
- Vol. 1380, 185-202
Magnetic Resonance Electrical Properties Tomography (MREPT)
This chapter explains the magnetic resonance electrical impedance tomography (MREPT) technique used to image electrical properties at high frequencies. The chapter describes the MREPT data acquisition methods, current state-of-the-art image reconstruction algorithms, and experiments with phantoms, animals, and humans.
- 23 April 2022
- Published by Springer Nature
- Vol. 1380, 185-202
Magnetic Resonance Electrical Properties Tomography (MREPT)
This chapter explains the magnetic resonance electrical impedance tomography (MREPT) technique used to image electrical properties at high frequencies. The chapter describes the MREPT data acquisition methods, current state-of-the-art image reconstruction algorithms, and experiments with phantoms, animals, and humans.