Izumi Nishimura
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Izumi Nishimura has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
Tadashi Negishi
Environmental Science Research Laboratory, Central Research Institute of Electric Power Industry, Chiba, Japan
5 shared publicationsAtsushi Oshima
Contract Testing Department, Nippon Institute for Biological Science, Tokyo, Japan
3 shared publicationsKazumoto Shibuya
Contract Testing Department, Nippon Institute for Biological Science, Tokyo, Japan
3 shared publicationsTakashi Mitani
Environmental Science Research Laboratory, Central Research Institute of Electric Power Industry, Chiba, Japan
2 shared publicationsKeiko Tanaka
Department of Hematology and Oncology The University of Tokyo Hospital Bunkyo Tokyo Japan
1 shared publicationMayumi Kawabe
DIMS Institute of Medical Science, Ichinomiya, Japan
1 shared publication
Latest Publications
- Open Access
- 15 March 2019
- Published by Wiley in Bioelectromagnetics
- Vol. 40 (3) , 160-169
Carcinogenicity of intermediate frequency magnetic field in Tg.rasH2 mice
Although the likelihood of exposure to leaking intermediate frequency magnetic fields (MFs) from electronic devices, such as induction‐heating and wireless power transfer systems, has increased, biological data assessing the health risks associated with human exposure remain insufficient. We examined the carcinogenicity of a 20 kHz MF, a typical frequency produced by induction‐heating cookers, using a transgenic rasH2 mouse model. Twenty‐five male and female CByB6F1‐Tg(HRAS)2Jic mice were exposed to a 0.20 mT, 20 kHz MF (22 h/day) or sham‐exposed for 26 weeks. As a positive control, 10 male and female rasH2 mice from the same batch were administered a single intraperitoneal injection of 75 mg/kg N‐methyl‐N‐nitrosourea. A blinded histopathological evaluation was performed, and the same experiments were conducted twice, independently, to confirm the reproducibility of the results. Histopathological examination revealed that spontaneous neoplastic lesions, such as splenic hemangiosarcomas and gastric squamous cell papillomas, were less (1–3 per group) in the MF‐ and sham‐exposed groups. The frequency of the neoplastic lesions was not significantly different between the groups. Eight to ten mice in each positive‐control group exhibited malignant lymphoma. The outcomes were consistent between duplicated experiments, which indicates lack of carcinogenicity of 20 kHz MF in the rasH2 mouse model. Bioelectromagnetics. © 2019 The Authors. Bioelectromagnetics Published by Wiley Periodicals, Inc.
- 15 March 2019
- Published by Wiley in Bioelectromagnetics
- Vol. 40 (3) , 160-169
Open AccessCarcinogenicity of intermediate frequency magnetic field in Tg.rasH2 mice
Although the likelihood of exposure to leaking intermediate frequency magnetic fields (MFs) from electronic devices, such as induction‐heating and wireless power transfer systems, has increased, biological data assessing the health risks associated with human exposure remain insufficient. We examined the carcinogenicity of a 20 kHz MF, a typical frequency produced by induction‐heating cookers, using a transgenic rasH2 mouse model. Twenty‐five male and female CByB6F1‐Tg(HRAS)2Jic mice were exposed to a 0.20 mT, 20 kHz MF (22 h/day) or sham‐exposed for 26 weeks. As a positive control, 10 male and female rasH2 mice from the same batch were administered a single intraperitoneal injection of 75 mg/kg N‐methyl‐N‐nitrosourea. A blinded histopathological evaluation was performed, and the same experiments were conducted twice, independently, to confirm the reproducibility of the results. Histopathological examination revealed that spontaneous neoplastic lesions, such as splenic hemangiosarcomas and gastric squamous cell papillomas, were less (1–3 per group) in the MF‐ and sham‐exposed groups. The frequency of the neoplastic lesions was not significantly different between the groups. Eight to ten mice in each positive‐control group exhibited malignant lymphoma. The outcomes were consistent between duplicated experiments, which indicates lack of carcinogenicity of 20 kHz MF in the rasH2 mouse model. Bioelectromagnetics. © 2019 The Authors. Bioelectromagnetics Published by Wiley Periodicals, Inc.
- Open Access
- 17 May 2015
- Published by Wiley in Journal of Applied Toxicology
- Vol. 36 (2) , 199-210
Acute and subchronic toxicity of 20 kHz and 60 kHz magnetic fields in rats
Despite increasing use of intermediate frequency (IF) magnetic fields (MFs) in occupational and domestic settings, scientific evidence necessary for health risk assessments of IF MF is insufficient. Male and female Crl:CD(SD) rats (12 per sex per group) were exposed to 20 kHz, 0.20 mT(root mean square, rms) or 60 kHz, 0.10 mT(rms) sinusoidal MFs for 22 h day−1 for 14 days (acute) or 13 weeks (subchronic). Experiments were duplicated for each frequency to ensure outcome reproducibility, and examinations were blinded for quality assurance. All rats survived without significant clinical signs until the end of experiments. Some changes in body weight between the MF‐exposed and control groups were observed over the course of exposure, although the directions of the changes were inconsistent and not statistically significant after subchronic exposure. There were significant differences between MF‐exposed and control groups in some organ weights and parameters in hematology and clinical chemistry, but these were minor in magnitude and not repeated in duplicate experiments. Histopathological findings reflecting toxicity were sporadic. Frequencies of other findings were similar to historic data in this rat strain, and findings had no specific relationship to changes in organ weight or parameters of hematology and clinical chemistry in each animal. The changes observed throughout this study were considered biologically isolated and were attributable to chance associations rather than to MF exposure. The results, in particular the histopathological evidence, indicate an absence of toxicity in IF MF‐exposed rats and do not support the hypothesis that IF MF exposure produces significant toxicity. Copyright © 2015. The Authors. Journal of Applied Toxicology Published by John Wiley & Sons Ltd.
- 17 May 2015
- Published by Wiley in Journal of Applied Toxicology
- Vol. 36 (2) , 199-210
Open AccessAcute and subchronic toxicity of 20 kHz and 60 kHz magnetic fields in rats
Despite increasing use of intermediate frequency (IF) magnetic fields (MFs) in occupational and domestic settings, scientific evidence necessary for health risk assessments of IF MF is insufficient. Male and female Crl:CD(SD) rats (12 per sex per group) were exposed to 20 kHz, 0.20 mT(root mean square, rms) or 60 kHz, 0.10 mT(rms) sinusoidal MFs for 22 h day−1 for 14 days (acute) or 13 weeks (subchronic). Experiments were duplicated for each frequency to ensure outcome reproducibility, and examinations were blinded for quality assurance. All rats survived without significant clinical signs until the end of experiments. Some changes in body weight between the MF‐exposed and control groups were observed over the course of exposure, although the directions of the changes were inconsistent and not statistically significant after subchronic exposure. There were significant differences between MF‐exposed and control groups in some organ weights and parameters in hematology and clinical chemistry, but these were minor in magnitude and not repeated in duplicate experiments. Histopathological findings reflecting toxicity were sporadic. Frequencies of other findings were similar to historic data in this rat strain, and findings had no specific relationship to changes in organ weight or parameters of hematology and clinical chemistry in each animal. The changes observed throughout this study were considered biologically isolated and were attributable to chance associations rather than to MF exposure. The results, in particular the histopathological evidence, indicate an absence of toxicity in IF MF‐exposed rats and do not support the hypothesis that IF MF exposure produces significant toxicity. Copyright © 2015. The Authors. Journal of Applied Toxicology Published by John Wiley & Sons Ltd.
- 2 September 2013
- Published by Wiley in Congenital Anomalies
- Vol. 53 (3) , 115-121
Intermediate frequency magnetic field and chick embryotoxicity
Intermediate frequency magnetic fields (MFs) have widely been used in industrial machines and home appliances, such as induction heating cookers, although toxicity studies to evaluate the potential health risks of such fields are insufficient. In induction heating cookers, the MF source (i.e. hobs), is located near the abdominal position of a person cooking. Hence, developmental effects on the fetus may be a concern in case the person is a pregnant woman. Fertile White Leghorn eggs (60/group) were either exposed to 20 kHz, 1.1 mT(rms) or 60 kHz, 0.11 mT(rms) sinusoidal MFs for 19 days during embryogenesis. The same number of eggs served as a control group. In addition, a sham‐sham experiment was conducted to validate the equality between exposure and control facilities. After exposure, embryos were examined for mortality rate and stage. Live embryos were evaluated for developmental stage and gross and skeletal anomalies. Length of upper beak and leg digits was also measured. Examinations were conducted in a blinded fashion to ensure quality assurance; experiments were triplicated for each frequency to confirm the outcome reproducibility. Mortality rate and stage, incidence of malformed embryos, and developmental variables in live embryos were found to be similar between the MF‐exposed and corresponding control group. Incidence of gross anomalies such as mandibular edema and skeletal anomalies such as coccyx defects were low across the experiments, and no significant group differences were noted. In conclusion, exposure to 20 kHz or 60 kHz MF did not produce any significant teratogenic developmental effects in chick embryos.
- 2 September 2013
- Published by Wiley in Congenital Anomalies
- Vol. 53 (3) , 115-121
Intermediate frequency magnetic field and chick embryotoxicity
Intermediate frequency magnetic fields (MFs) have widely been used in industrial machines and home appliances, such as induction heating cookers, although toxicity studies to evaluate the potential health risks of such fields are insufficient. In induction heating cookers, the MF source (i.e. hobs), is located near the abdominal position of a person cooking. Hence, developmental effects on the fetus may be a concern in case the person is a pregnant woman. Fertile White Leghorn eggs (60/group) were either exposed to 20 kHz, 1.1 mT(rms) or 60 kHz, 0.11 mT(rms) sinusoidal MFs for 19 days during embryogenesis. The same number of eggs served as a control group. In addition, a sham‐sham experiment was conducted to validate the equality between exposure and control facilities. After exposure, embryos were examined for mortality rate and stage. Live embryos were evaluated for developmental stage and gross and skeletal anomalies. Length of upper beak and leg digits was also measured. Examinations were conducted in a blinded fashion to ensure quality assurance; experiments were triplicated for each frequency to confirm the outcome reproducibility. Mortality rate and stage, incidence of malformed embryos, and developmental variables in live embryos were found to be similar between the MF‐exposed and corresponding control group. Incidence of gross anomalies such as mandibular edema and skeletal anomalies such as coccyx defects were low across the experiments, and no significant group differences were noted. In conclusion, exposure to 20 kHz or 60 kHz MF did not produce any significant teratogenic developmental effects in chick embryos.
- Open Access
- 1 December 2012
- Published by Elsevier in Regulatory Toxicology and Pharmacology
- Vol. 64 (3) , 394-401
Absence of reproductive and developmental toxicity in rats following exposure to a 20-kHz or 60-kHz magnetic field
- 1 December 2012
- Published by Elsevier in Regulatory Toxicology and Pharmacology
- Vol. 64 (3) , 394-401
Open AccessAbsence of reproductive and developmental toxicity in rats following exposure to a 20-kHz or 60-kHz magnetic field
- Open Access
- 18 July 2011
- Published by Wiley in Birth Defects Research Part B: Developmental and Reproductive Toxicology
- Vol. 92 (5) , 469-477
Lack of teratological effects in rats exposed to 20 or 60 kHz magnetic fields
BACKGROUND: A risk assessment of magnetic field (MF) exposure conducted by the World Health Organization indicated the need for biological studies on primary hazard identification and quantitative risk evaluation of intermediate frequency (300 Hz–100 kHz) MFs. Because induction heating cookers generate such MFs for cooking, reproductive and developmental effects are a concern due to the close proximity of the fields' source to a cook's abdomen. METHODS: Pregnant Crl:CD(SD) rats (25/group) were exposed to a 20 kHz, 0.2 mT(rms) or 60 kHz, 0.1 mT(rms) sinusoidal MF or sham‐exposed for 22 hr/day during organogenesis, and their fetuses were examined for malformations on gestation day 20. All teratological evaluations were conducted in a blind fashion, and experiments were duplicated for each frequency to confirm consistency of experimental outcomes. RESULTS: No exposure‐related changes were found in clinical signs, gross pathology, or number of implantation losses. The number of live fetuses and low‐body‐weight fetuses as well as the incidence of external, visceral, and skeletal malformations in the fetuses did not indicate significant differences between MF‐exposed and sham‐exposed groups. Although some fetuses showed isolated changes in sex ratio and skeletal variation and ossification, such changes were neither reproduced in duplicate experiments nor were they common to specific field frequencies. CONCLUSIONS: Exposure of rats to MFs during organogenesis did not show significant reproducible teratogenicity under experimental conditions. Present findings do not support the hypothesis that intermediate frequency MF exposure after implantation carries a significant risk for developing mammalian fetuses. Birth Defects Res (Part B) 92:469–477, 2011.
- 18 July 2011
- Published by Wiley in Birth Defects Research Part B: Developmental and Reproductive Toxicology
- Vol. 92 (5) , 469-477
Open AccessLack of teratological effects in rats exposed to 20 or 60 kHz magnetic fields
BACKGROUND: A risk assessment of magnetic field (MF) exposure conducted by the World Health Organization indicated the need for biological studies on primary hazard identification and quantitative risk evaluation of intermediate frequency (300 Hz–100 kHz) MFs. Because induction heating cookers generate such MFs for cooking, reproductive and developmental effects are a concern due to the close proximity of the fields' source to a cook's abdomen. METHODS: Pregnant Crl:CD(SD) rats (25/group) were exposed to a 20 kHz, 0.2 mT(rms) or 60 kHz, 0.1 mT(rms) sinusoidal MF or sham‐exposed for 22 hr/day during organogenesis, and their fetuses were examined for malformations on gestation day 20. All teratological evaluations were conducted in a blind fashion, and experiments were duplicated for each frequency to confirm consistency of experimental outcomes. RESULTS: No exposure‐related changes were found in clinical signs, gross pathology, or number of implantation losses. The number of live fetuses and low‐body‐weight fetuses as well as the incidence of external, visceral, and skeletal malformations in the fetuses did not indicate significant differences between MF‐exposed and sham‐exposed groups. Although some fetuses showed isolated changes in sex ratio and skeletal variation and ossification, such changes were neither reproduced in duplicate experiments nor were they common to specific field frequencies. CONCLUSIONS: Exposure of rats to MFs during organogenesis did not show significant reproducible teratogenicity under experimental conditions. Present findings do not support the hypothesis that intermediate frequency MF exposure after implantation carries a significant risk for developing mammalian fetuses. Birth Defects Res (Part B) 92:469–477, 2011.
- 3 June 2009
- Published by Wiley in Bioelectromagnetics
- Vol. 30 (7) , 573-582
Lack of chick embryotoxicity after 20 kHz, 1.1 mT magnetic field exposure
This investigation was undertaken because biological studies to evaluate the effects of intermediate frequency magnetic fields are insufficient. White Leghorn fertile eggs (60/group) were either exposed to a 20 kHz, 1.1 mT(rms) sinusoidal magnetic field or sham-exposed during the first 2, 7, or 11 days of embryogenesis. Lower dose exposures at 0.011 and 0.11 mT(rms) for 2 days were also conducted to elucidate possible dose–response relationships. Additional eggs given all-trans-retinoic acid, a teratogen, were exposed to the 1.1 mT(rms) magnetic field for the same periods to investigate the modification of embryotoxicity. After exposure, embryos were examined for mortality and developmental abnormalities. Developmental stage, number of somite pairs, and other developmental endpoints were also evaluated. Experiments were triplicated and conducted in a blind fashion. No exposure-related changes were found in any of the endpoints in intact embryos exposed to1.1 mT(rms) or to the lower doses of 0.11 and 0.011 mT(rms) magnetic fields. Retinoic acid administration produced embryotoxic responses, which were embryonic death and developmental abnormalities, in 40–60% of embryos in the sham-exposed groups. The magnitude of these responses was not changed significantly by the magnetic field exposures. Under the present experimental conditions, exposure to 20 kHz magnetic field up to 1.1 mT(rms) was not embryotoxic in the chick and did not potentiate the embryotoxic action of retinoic acid. Bioelectromagnetics 30:573–582, 2009.
- 3 June 2009
- Published by Wiley in Bioelectromagnetics
- Vol. 30 (7) , 573-582
Lack of chick embryotoxicity after 20 kHz, 1.1 mT magnetic field exposure
This investigation was undertaken because biological studies to evaluate the effects of intermediate frequency magnetic fields are insufficient. White Leghorn fertile eggs (60/group) were either exposed to a 20 kHz, 1.1 mT(rms) sinusoidal magnetic field or sham-exposed during the first 2, 7, or 11 days of embryogenesis. Lower dose exposures at 0.011 and 0.11 mT(rms) for 2 days were also conducted to elucidate possible dose–response relationships. Additional eggs given all-trans-retinoic acid, a teratogen, were exposed to the 1.1 mT(rms) magnetic field for the same periods to investigate the modification of embryotoxicity. After exposure, embryos were examined for mortality and developmental abnormalities. Developmental stage, number of somite pairs, and other developmental endpoints were also evaluated. Experiments were triplicated and conducted in a blind fashion. No exposure-related changes were found in any of the endpoints in intact embryos exposed to1.1 mT(rms) or to the lower doses of 0.11 and 0.011 mT(rms) magnetic fields. Retinoic acid administration produced embryotoxic responses, which were embryonic death and developmental abnormalities, in 40–60% of embryos in the sham-exposed groups. The magnitude of these responses was not changed significantly by the magnetic field exposures. Under the present experimental conditions, exposure to 20 kHz magnetic field up to 1.1 mT(rms) was not embryotoxic in the chick and did not potentiate the embryotoxic action of retinoic acid. Bioelectromagnetics 30:573–582, 2009.