Eva Berbekar
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Eva Berbekar has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
Bernd Leitl
Meteorological Institute, University of Hamburg, Germany
2 shared publicationsFrank Harms
Meteorological Institute, University of Hamburg, Germany
2 shared publications- George C. Efthimiou
Environmental Research Laboratory, Institute of Nuclear and Radiological Sciences and Technology, Energy and Safety, National Centre for Scientific Research “Demokritos”, 15341 Agia Paraskevi, Greece, Greece
2 shared publications - Bernd Leitl
Meteorological Institute, KlimaCampus, University of Hamburg, Bundesstrasse 55, D-20146 Hamburg, Germany
1 shared publication - Denise Hertwig
Department of Meteorology, University of Reading, Reading, RG6 6ET, UK
1 shared publication - Frank Harms
Meteorological Institute, KlimaCampus, University of Hamburg, Bundesstrasse 55, D-20146 Hamburg, Germany
1 shared publication
Latest Publications
- Open Access
Modelling Short-Term Maximum Individual Exposure from Airborne Hazardous Releases in Urban Environments. Part ΙI: Validation of a Deterministic Model with Wind Tunnel Experimental Data
The capability to predict short-term maximum individual exposure is very important for several applications including, for example, deliberate/accidental release of hazardous substances, odour fluctuations or material flammability level exceedance. Recently, authors have proposed a simple approach relating maximum individual exposure to parameters such as the fluctuation intensity and the concentration integral time scale. In the first part of this study (Part I), the methodology was validated against field measurements, which are governed by the natural variability of atmospheric boundary conditions. In Part II of this study, an in-depth validation of the approach is performed using reference data recorded under truly stationary and well documented flow conditions. For this reason, a boundary-layer wind-tunnel experiment was used. The experimental dataset includes 196 time-resolved concentration measurements which detect the dispersion from a continuous point source within an urban model of semi-idealized complexity. The data analysis allowed the improvement of an important model parameter. The model performed very well in predicting the maximum individual exposure, presenting a factor of two of observations equal to 95%. For large time intervals, an exponential correction term has been introduced in the model based on the experimental observations. The new model is capable of predicting all time intervals giving an overall factor of two of observations equal to 100%.
Open AccessModelling Short-Term Maximum Individual Exposure from Airborne Hazardous Releases in Urban Environments. Part ΙI: Validation of a Deterministic Model with Wind Tunnel Experimental Data
The capability to predict short-term maximum individual exposure is very important for several applications including, for example, deliberate/accidental release of hazardous substances, odour fluctuations or material flammability level exceedance. Recently, authors have proposed a simple approach relating maximum individual exposure to parameters such as the fluctuation intensity and the concentration integral time scale. In the first part of this study (Part I), the methodology was validated against field measurements, which are governed by the natural variability of atmospheric boundary conditions. In Part II of this study, an in-depth validation of the approach is performed using reference data recorded under truly stationary and well documented flow conditions. For this reason, a boundary-layer wind-tunnel experiment was used. The experimental dataset includes 196 time-resolved concentration measurements which detect the dispersion from a continuous point source within an urban model of semi-idealized complexity. The data analysis allowed the improvement of an important model parameter. The model performed very well in predicting the maximum individual exposure, presenting a factor of two of observations equal to 95%. For large time intervals, an exponential correction term has been introduced in the model based on the experimental observations. The new model is capable of predicting all time intervals giving an overall factor of two of observations equal to 100%.
- 1 February 2015
- Published by Elsevier in Journal of Hazardous Materials
- Vol. 283, 178-185
Dosage-based parameters for characterization of puff dispersion results
- 1 February 2015
- Published by Elsevier in Journal of Hazardous Materials
- Vol. 283, 178-185
Dosage-based parameters for characterization of puff dispersion results