Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Elisa Michelini has a total of 239 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Novel Smartphone Paper Sensor for One Health: Monitoring Free Chlorine in Water and Exhaled Breath Condensate

    by Caterina Cambrea, Robert Josue Rodriguez Arias, Riccardo Desiderio, Faisal Nazir, Maria Maddalena Calabretta, Elisa Michelini

    Disinfection is essential to ensure safe drinking water and hygienic conditions in environmental, industrial, and clinical settings. However, conventional methods for monitoring free residual chlorine are often laboratory-based and not suited for decentralized analysis. Here, we report a novel paper-based colorimetric biosensing platform that translates the ISO 7393-2 standard, a method based on the reaction of chlorine with N,N-diethyl-p-phenylenediamine (DPD), into a portable and user-friendly format. The proposed device integrates the DPD chemistry within a paper architecture, enabling reagent-free operation at the point of need. The sensor provides a rapid visual readout that is detectable by the naked eye, while quantitative analysis is achieved within 3 min through smartphone-based image acquisition. This work constitutes the first implementation of the ISO standard in a portable paper-based format suitable for both environmental and clinical matrices. The sensor provided a detection limit of 12 μM for sodium hypochlorite and was successfully validated in real samples, including bottled water and exhaled breath condensate, with satisfactory recoveries. Furthermore, the stability of the paper-based sensor was assessed under storage conditions of 4 °C and room temperature (23 °C), demonstrating excellent performance over 30 days in both cases, indicating that refrigeration is not required for maintaining sensor performance.


  • Open Access

    All-in-One Sustainable Thread Biosensor for Chemiluminescence Smartphone Detection of Lactate in Sweat

    by Emanuela Maiorano, Maria Maddalena Calabretta, Eugenio Lunedei, Elisa Michelini

    Thanks to their low-cost, portability, and sustainability, microfluidic thread-based analytical devices (μTADs) are emerging as an attractive analytical platform for wearable biosensing. While several μTADs, mainly based on colorimetric and electrochemical detection methods, have been developed, achieving the needed sensitivity and accuracy for these biosensors continues to present a significant challenge. Prompted by this need we investigated for the first time the implementation of chemiluminescence (CL) as a detection technique for μTADs. Exploiting the lactate oxidase-catalyzed reaction coupled with the enhanced luminol/H2O2/horseradish peroxidase CL system, we developed a cotton-thread-based chemiluminescent device enabling the detection of lactate with a limit of detection of 0.25 mM in a 2 µL volume of artificial sweat at pH 6.5 within 3 min. The use of recycled grape skin as support made the device sustainable, while the smartphone detection allowed a simple and quantitative readout for the end-user. Using a smartphone as a detector, the analytical performance was evaluated in different conditions and in the presence of potential interferents, showing suitability for monitoring lactate levels in physiological conditions, such as for monitoring anaerobic thresholds in endurance training.


  • Open Access

    An All-in-One Sustainable Smartphone Paper Biosensor for Water Toxicity Monitoring Combining Bioluminescence Detection with Artificial Intelligence

    by Faisal Nazir, Denise Gregucci, Maria Maddalena Calabretta, Caterina Cambrea, Peyman Vahidi, Stevo Lavrnić, Attilio Toscano, Elisa Michelini

    Several biosensors for water toxicity monitoring have been reported in the literature; however, none of them fully integrate both analytical and post-analytical steps that are required in a standard laboratory setting before reporting the result. To provide a workflow for smartphone biosensor developers, we implemented a novel procedure that was applied to the standard toxicity assay based on the bioluminescent bacteria Aliivibrio fischeri. We addressed the main issues to turn this method into a sustainable all-in-one toxicity paper biosensor, i.e., the immobilization of bacteria, the integration of a calibration curve, and a customized artificial intelligence (AI) application that converts the smartphone picture into user-friendly quantitative information. The biosensor analytical performance was evaluated with different water contaminants and real water samples, showing promising results. A limit of detection of 0.23 ppb was obtained for the cyanotoxin microcystin-LR produced by harmful algal blooms. We also demonstrated for the first time that the inclusion of a calibration curve in a paper sensor, combined with an AI app, enables accurate analyses even when pictures are taken with smartphone models equipped with cameras with different resolutions. To the best of our knowledge, this is the first bioluminescence paper biosensor in which an AI algorithm enables to obtain quantitative results by interpolating the bioluminescent signals from an on-board calibration curve. We believe this novel biosensor will open new opportunities not only for water monitoring, but the same approach could be implemented in any optical smartphone biosensor for applications spanning from onsite analysis to citizen science.


  • Open Access

    Integrating Model-Based Systems Engineering into CubeSat Development: A Case Study of the BOREALIS Mission

    by Lorenzo Nardi, Stefano Carletta, Parsa Abbasrezaee, Giovanni Palmerini, Nicola Lovecchio, Nunzio Burgio, Alfonso Santagata, Massimo Frullini, Donato Calabria, Massimo Guardigli, et al.

    The Biofilm Onboard Radiation Exposure Assessment Lab In Space (BOREALIS) mission is a 6U CubeSat initiative funded by the Italian Space Agency under the ALCOR program, executed through a collaboration among the School of Aerospace Engineering of Sapienza University of Rome, Interdepartmental Centre for Industrial Aerospace Research (CIRI Aerospace) of the University of Bologna and Kayser Italia Srl. BOREALIS is equipped with a lab-on-chip payload for studying the effects of microgravity and ionising radiation on microbial biofilms, which are crucial for understanding and preventing persistent infections in space environments. The satellite will operate across multiple orbits, moving from low to medium Earth orbit, to distinctly analyse the impacts of radiation separate from microgravity. The required orbital transfer not only tests the autonomy of its on-board systems in challenging conditions but also places BOREALIS among the first and few CubeSats to have ever attempted such a complex manoeuvre. This study explores the systematic application of Model-Based Systems Engineering to satellite design, from conceptualisation to trade-offs, using a tradespace analysis approach supported by Monte Carlo simulations to optimise mission configurations against performance and cost. Additionally, the adaptability of Model-Based Systems Engineering tools and the reusability of such an approach for other satellite projects are discussed, illustrating the BOREALIS mission as a case study for small mission design considering constraints and requirements.


  • Open Access

    An origami colorimetric paper-based sensor for sustainable on-site and instrument-free analysis of nitrite

    by Denise Gregucci, Maria Maddalena Calabretta, Faisal Nazir, Robert Josue Rodriguez Arias, Federico Biondi, Riccardo Desiderio, Elisa Michelini

    Ready-to-use colorimetric paper sensor, based on the Griess reaction, for nitrite on-site monitoring.


  • Open Access

    Bioluminescence biosensing platforms for One Health: From paper sensors to thread-based analytical devices

    by Elisa Michelini, Denise Gregucci, Faisal Nazir, Emanuela Maiorano, Maria Maddalena Calabretta

    Bioluminescence is a fascinating phenomenon in which photons are emitted as byproduct of a chemical reaction occurring in living organisms, including bacteria, fireflies, and several marine species. Here we report the development of novel bioluminescent tools and strategies which can be used to improve the analytical performance of paper-based smartphone biosensors. In particular two new applications are reported based on paper and thread-based bioluminescent biosensors.

  • Novel bioassays based on 3D-printed device for sensing of hypoxia and p53 pathway in 3D cell models

    by Maria Maddalena Calabretta, Maura Ferri, Annalisa Tassoni, Stefania Maiello, Elisa Michelini

    Cell-based assays are widely exploited for drug screening and biosensing, providing useful information about bioactivity of target analytes and complex biological samples. It is well recognized that 3D cell models are required to achieve highly valuable information, also from the perspective of replacing animal models. However, bioassays relying on 3D cell models are generally highly demanding in terms of facilities, equipment, and skilled personnel requirements. To reduce cost, increase sustainability, and provide a flexible 3D cell-based platform for bioassays, we here report a novel approach based on a 3D-printed microtissue device. To assess the suitability of this strategy for reporter gene technology, we selected to monitor two molecular pathways which were of interest in several applications, hypoxia signaling and the p53 pathway. The investigation of such pathways is highly relevant in fields spanning from drug screening to bioactivity monitoring for industrial by-product valorization. Microtissues of human hepatocarcinoma (HepG2) and human embryonic kidney (Hek293T) cell lines were obtained with a low-cost and sustainable chip platform and bioassays were developed to monitor the hypoxia-inducible factors (HIFs) and the p53 tumor suppressor pathway. HepG2 and Hek293T 3D cell models were genetically engineered to express the Luc2P from Photinus pyralis firefly either under the regulation of p53 or HIF response elements. The bioassays allowed quantitative assessment of hypoxia and tumoral activity with 1,10-phenanthroline for HIF and with doxorubicin for p53 pathway activation, respectively, showing good potential for applications of this sustainable and low-cost 3D-printed microfluidic platform for bioactivity analyses, drug screening, and precision medicine. Graphical Abstract

  • Chemiluminescence “Add-and-Measure” Sensing Paper Based on the Prussian Blue/Metal–Organic Framework MIL-101 Nanozyme for Rapid Hydrogen Peroxide Detection

    by Héctor Martínez-Pérez-Cejuela, Maria Maddalena Calabretta, Elisa Michelini

    In this work, a chemiluminescent sensing paper has been developed using a peroxidase biomimetic metal-organic framework as a versatile host platform. For the first time, we have explored the use of in situ growth of Prussian Blue nanoparticles (PB-NPs) onto the MIL-101(Fe) structure for the assembly of a ready-to-use sensing paper. In situ growth of PB-NPs has been performed on the surface of the MIL-101(n) family. This novel composite, named PB-NPs@MIL-101(Fe), has been successfully used to develop a sensing paper for one-step detection of H2O2 in real samples (commercial disinfectant solutions and tap water samples). The as-prepared material was fully characterized, including X-ray analysis, Fourier transform infrared, scanning and transmission electron microscopies, nitrogen isotherms, and elemental analysis. After the characterization, the analytical performance of the PB-NPs@MIL-101(Fe) sensing paper was evaluated. The low-cost sensor (0.15 euro per unit) was able to detect down to 8.2 μM (corresponding to 8.2 × 10-11 mol) H2O2 using only 10 μL of sample with satisfactory reproducibility (relative standard deviation 17%).


  • Open Access

    The dynamics of capillary flow in an open-channel system featuring trigger valves

    by Jodie C. Tokihiro, Ingrid H. Robertson, Denise Gregucci, Albert Shin, Elisa Michelini, Tristan M. Nicholson, Ayokunle Olanrewaju, Ashleigh B. Theberge, Jean Berthier, Erwin Berthier

    Trigger valves are fundamental features in capillary-driven microfluidic systems that stop fluid at an abrupt geometric expansion and release fluid when there is flow in an orthogonal channel connected to the valve. The concept was originally demonstrated in closed-channel capillary circuits. We show here that trigger valves can be successfully implemented in open channels. We also show that a series of open-channel trigger valves can be placed alongside or opposite a main channel resulting in a layered capillary flow. We developed a closed form model for the dynamics of the flow at trigger valves based on the concept of average friction length and successfully validated the model against experiments. For the main channel, we discuss layered flow behavior in the light of the Taylor-Aris dispersion theory and in the channel turns by considering Dean theory of mixing. This work has potential applications in autonomous microfluidics systems for biosensing, at-home or point-of-care sample preparation devices, hydrogel patterning for 3D cell culture and organ-on-a-chip models.

  • Open Access

    Low-cost and sustainable smartphone-based tissue-on-chip device for bioluminescence biosensing

    by Maria Maddalena Calabretta, Denise Gregucci, Massimo Guardigli, Elisa Michelini