Alessandro Borella
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Alessandro Borella has a total of 56 co-authors. Here are the top co-authors by number of shared publications:
- Riccardo Rossa
Belgian Nuclear Research Centre (SCK CEN), Industriezone Boeretang Zuid, Boeretang 190, 2400 Mol, Belgium
7 shared publications Riccardo Rossa
SCK CEN, Belgian Nucl Res Ctr, B-2400 Mol, Belgium
4 shared publications- Bart Rogiers
Belgian Nuclear Research Centre
3 shared publications - Eric Laloy
Belgian Nuclear Research Centre
3 shared publications - Imre Pazsit
Chalmers University of Technology
3 shared publications - Moad Al-Dbissi
High Energy & Plasma Phys Chalmers Univ Technol, Div Subatom, S-41296 Gothenburg, Sweden
3 shared publications
Latest Publications
- Open Access
- 7 February 2026
- Published by Elsevier in SSRN Electronic Journal
Neutron cross sections validations by means of BR1 reactor
A precise knowledge of the 235U prompt fission neutron spectrum is essential for reliable criticality safety analyses, reactor physics calculations, and nuclear data validation. In this work, the 235U prompt fission neutron spectrum was investigated and validated using a set of selected threshold reactions with well-known cross sections. Activation experiments were performed at the BR1 graphite-moderated research reactor using the MARK III 235U fission neutron converter and the S84 pneumatic irradiation channel. Threshold reactions 28Si(n,p)28Al, 169Tm(n,2n)168Tm, 92Mo(n,p)92mNb, and 19F(n,2n)18F were used for PFNS validation, 29Si(n,p)29Al, 141Pr(n,2n)140Pr, and 117Sn(n,n')117mSn reactions were selected for validation of their neutron cross sections, while capture reactions 176Yb(n,γ)177Yb, 141Pr(n,γ)142Pr, and 115In(n,γ)116mIn served for cross-section validation in thermal and epithermal neutron fields. Spectrum averaged cross section in 235U PFNS was measured for the first time for 141Pr(n,2n)140Pr reaction. Reaction rates were determined by high-resolution HPGe gamma-ray spectroscopy, applying efficiency transfer, coincidence summing, and self-shielding corrections supported by MCNP6.3 simulations. The measured spectrum-averaged cross sections were compared with calculations using IRDFF-II and ENDF/B-VIII.0 nuclear data libraries. Good agreement within combined uncertainties was observed for most dosimetric reactions, confirming the consistency of the ENDF/B-VIII.0 adopted 235U PFNS. However, significant discrepancies were identified for the silicon (n,p) reactions, indicating a potential need for reevaluation of these cross sections.
- 7 February 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessNeutron cross sections validations by means of BR1 reactor
A precise knowledge of the 235U prompt fission neutron spectrum is essential for reliable criticality safety analyses, reactor physics calculations, and nuclear data validation. In this work, the 235U prompt fission neutron spectrum was investigated and validated using a set of selected threshold reactions with well-known cross sections. Activation experiments were performed at the BR1 graphite-moderated research reactor using the MARK III 235U fission neutron converter and the S84 pneumatic irradiation channel. Threshold reactions 28Si(n,p)28Al, 169Tm(n,2n)168Tm, 92Mo(n,p)92mNb, and 19F(n,2n)18F were used for PFNS validation, 29Si(n,p)29Al, 141Pr(n,2n)140Pr, and 117Sn(n,n')117mSn reactions were selected for validation of their neutron cross sections, while capture reactions 176Yb(n,γ)177Yb, 141Pr(n,γ)142Pr, and 115In(n,γ)116mIn served for cross-section validation in thermal and epithermal neutron fields. Spectrum averaged cross section in 235U PFNS was measured for the first time for 141Pr(n,2n)140Pr reaction. Reaction rates were determined by high-resolution HPGe gamma-ray spectroscopy, applying efficiency transfer, coincidence summing, and self-shielding corrections supported by MCNP6.3 simulations. The measured spectrum-averaged cross sections were compared with calculations using IRDFF-II and ENDF/B-VIII.0 nuclear data libraries. Good agreement within combined uncertainties was observed for most dosimetric reactions, confirming the consistency of the ENDF/B-VIII.0 adopted 235U PFNS. However, significant discrepancies were identified for the silicon (n,p) reactions, indicating a potential need for reevaluation of these cross sections.
- 15 May 2024
- Published by Elsevier in Nuclear Engineering and Design
- Vol. 424
First steps towards productionizing probabilistic radwaste characterization
- 15 May 2024
- Published by Elsevier in Nuclear Engineering and Design
- Vol. 424
First steps towards productionizing probabilistic radwaste characterization
- Open Access
- 15 April 2024
- Published by Elsevier in Annals of Nuclear Energy
- Vol. 204
On the use of neutron flux gradient with ANNs for the detection of diverted spent nuclear fuel
- 15 April 2024
- Published by Elsevier in Annals of Nuclear Energy
- Vol. 204
Open AccessOn the use of neutron flux gradient with ANNs for the detection of diverted spent nuclear fuel
- Open Access
- 21 November 2023
- Published by EDP Sciences in EPJ Web of Conferences
- Vol. 288, 06008
Neutron coincidence counters for disarmament verification: Experiments and modeling
A measurement campaign in support of nuclear disarmament verification was carried out in 2019 on the premises of the Belgian Nuclear Research Centre, SCK CEN. Well-characterized MOX sources with different types of shielding materials were used during the campaign. The relative content of Pu was up to 14%wt and the isotopic abundance of 239Pu was up to 93%wt. One of the technologies that were deployed was neutron coincidence counting with 3He based slab counters.The obtained background and dead time corrected total and reals rates were used to determine the mass of the assayed sample by using the so-called point model equations. The obtained masses were systematically underestimated by 15 % in average. A calibration approach based on Monte Carlo simulations where the mass is estimated from the calculated number of reals per spontaneous fission event was also used. A Monte Carlo model of the measurements setup was therefore developed to account for the finite source size, multiplication, moderation and absorption in the detector and scattering in the environment, including the measurement room walls, floor and ceiling. By using a Monte Carlo based efficiency for the reals the masses were slightly overestimated by typically few percent. However, outliers were observed.In an effort to understand the obtained results, additional calculations were carried out to estimate the impact due to both the neutron emission by (>,n) reactions and spontaneous fission decay on the measured observables. The associated total and reals counts were obtained for various configurations and compared with the experimental data. The obtained results indicate the importance of (>,n) reactions when neutron multiplication is not negligible.
- 21 November 2023
- Published by EDP Sciences in EPJ Web of Conferences
- Vol. 288, 06008
Open AccessNeutron coincidence counters for disarmament verification: Experiments and modeling
A measurement campaign in support of nuclear disarmament verification was carried out in 2019 on the premises of the Belgian Nuclear Research Centre, SCK CEN. Well-characterized MOX sources with different types of shielding materials were used during the campaign. The relative content of Pu was up to 14%wt and the isotopic abundance of 239Pu was up to 93%wt. One of the technologies that were deployed was neutron coincidence counting with 3He based slab counters.The obtained background and dead time corrected total and reals rates were used to determine the mass of the assayed sample by using the so-called point model equations. The obtained masses were systematically underestimated by 15 % in average. A calibration approach based on Monte Carlo simulations where the mass is estimated from the calculated number of reals per spontaneous fission event was also used. A Monte Carlo model of the measurements setup was therefore developed to account for the finite source size, multiplication, moderation and absorption in the detector and scattering in the environment, including the measurement room walls, floor and ceiling. By using a Monte Carlo based efficiency for the reals the masses were slightly overestimated by typically few percent. However, outliers were observed.In an effort to understand the obtained results, additional calculations were carried out to estimate the impact due to both the neutron emission by (>,n) reactions and spontaneous fission decay on the measured observables. The associated total and reals counts were obtained for various configurations and compared with the experimental data. The obtained results indicate the importance of (>,n) reactions when neutron multiplication is not negligible.
- Open Access
- 25 July 2023
- Published by Elsevier in Annals of Nuclear Energy
- Vol. 193
Identification of diversions in spent PWR fuel assemblies by PDET signatures using Artificial Neural Networks (ANNs)
- 25 July 2023
- Published by Elsevier in Annals of Nuclear Energy
- Vol. 193
Open AccessIdentification of diversions in spent PWR fuel assemblies by PDET signatures using Artificial Neural Networks (ANNs)
- 25 January 2023
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 194, 110691
Improving Bayesian radiological profiling of waste drums using Dirichlet priors, Gaussian process priors, and hierarchical modeling
- 25 January 2023
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 194, 110691
Improving Bayesian radiological profiling of waste drums using Dirichlet priors, Gaussian process priors, and hierarchical modeling
- Open Access
- 17 December 2021
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1026, 166030
Conceptual design and initial evaluation of a neutron flux gradient detector
- 17 December 2021
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1026, 166030
Open AccessConceptual design and initial evaluation of a neutron flux gradient detector