Hakim Djelouah
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Hakim Djelouah has a total of 58 co-authors. Here are the top co-authors by number of shared publications:
- Jean-Luc Daridon
Universite de Pau et des Pays de l’Adour, E2S UPPA, CNRS, LFCR, Pau, France
4 shared publications M. Perdrix
4 shared publications- Djema Belgroune
Laboratoire de Physique des Matériaux Faculté de Physique, U.S.T.H.B.,B.P 32 El Alia 16111, Alger, Algeria
3 shared publications - Hassina Khelladi
Laboratoire des Fluides Complexes, UMR 5150, Université de Pau et des Pays de l'Adour, BP 1155, 64013 Pau Cedex, France
3 shared publications J.C. Baboux
3 shared publicationsJ.F. de Belleval
Laboratoire Roberval, Unité de Recherche en Mécanique, UMR CNRS 6066 Université de Technologie de Compiègne, BP. 20 259-60205 Cedex France
3 shared publications
Latest Publications
- 1 March 2017
- Published by Elsevier in Measurement
- Vol. 100, 279-287
Direct transduction method for measuring the ultrasonic attenuation in Si(111) in the frequency range 100 MHz–1 GHz
- 1 March 2017
- Published by Elsevier in Measurement
- Vol. 100, 279-287
Direct transduction method for measuring the ultrasonic attenuation in Si(111) in the frequency range 100 MHz–1 GHz
- 1 September 2016
- Published by Elsevier in Ultrasonics
- Vol. 71, 98-105
Reflection at a liquid–solid interface of a transient ultrasonic field radiated by a linear phased array transducer
- 1 September 2016
- Published by Elsevier in Ultrasonics
- Vol. 71, 98-105
Reflection at a liquid–solid interface of a transient ultrasonic field radiated by a linear phased array transducer
- 1 December 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Ultrasonic parameter estimation using the Maximum Likelihood Estimation
The estimation of the backscattered echo was performed using the Maximum Likelihood Estimation (MLE). The backscattered ultrasonic echo is modeled as a nonlinear function of a set of parameters using the Gaussian echo model corrupted with an additive noise. Because of the white Gaussian noise (WGN) assumption, the estimation problem reduces to a least squares estimation. Thus, the nonlinear least square curve fitting with the Levenberg-Marquardt (LM) optimization algorithm was tested in the estimation procedure. The results are compared with existing results from the literature. To improve the goodness of the fit, the multivariate denoising procedure were applied as a preprocessing operation. Then, the efficiency and robustness of the LM algorithm are evaluated for both denoised and noisy signals.
- 1 December 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Ultrasonic parameter estimation using the Maximum Likelihood Estimation
The estimation of the backscattered echo was performed using the Maximum Likelihood Estimation (MLE). The backscattered ultrasonic echo is modeled as a nonlinear function of a set of parameters using the Gaussian echo model corrupted with an additive noise. Because of the white Gaussian noise (WGN) assumption, the estimation problem reduces to a least squares estimation. Thus, the nonlinear least square curve fitting with the Levenberg-Marquardt (LM) optimization algorithm was tested in the estimation procedure. The results are compared with existing results from the literature. To improve the goodness of the fit, the multivariate denoising procedure were applied as a preprocessing operation. Then, the efficiency and robustness of the LM algorithm are evaluated for both denoised and noisy signals.
- Open Access
- 19 September 2015
- Published by Elsevier in Physics Procedia
- Vol. 70, 231-235
Angular Spectrum Method for the Focused Acoustic Field of a Linear Transducer
- 19 September 2015
- Published by Elsevier in Physics Procedia
- Vol. 70, 231-235
Open AccessAngular Spectrum Method for the Focused Acoustic Field of a Linear Transducer
- 15 January 2015
- Published by Springer Nature in Journal of Mechanical Science and Technology
- Vol. 29 (1) , 165-172
Numerical simulation of the transient ultrasonic wave reflection at a liquid-solid interface
- 15 January 2015
- Published by Springer Nature in Journal of Mechanical Science and Technology
- Vol. 29 (1) , 165-172
Numerical simulation of the transient ultrasonic wave reflection at a liquid-solid interface
- 1 March 2014
- Published by Elsevier in Ultrasonics
- Vol. 54 (3) , 860-866
Propagation of Lamb waves in an immersed periodically grooved plate: Experimental detection of the scattered converted backward waves
- 1 March 2014
- Published by Elsevier in Ultrasonics
- Vol. 54 (3) , 860-866
Propagation of Lamb waves in an immersed periodically grooved plate: Experimental detection of the scattered converted backward waves
- 1 July 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 852-855
Nonlinear characterization of tissue and microbubbles using Nakagami statistical model
The objective of this study is to exploit the statistical signatures of biological tissues and contrast microbubbles in order to develop new strategies for contrast imaging and tissue characterization. For this purpose, the Nakagami statistical model was chosen, because it is more general and simpler to apply than other statistical models to describe the linear and nonlinear ultrasonic echoes of both contrast microbubbles and tissues. Experiments were performed using a 2.5 MHz linear array connected to an open research platform. A commercially phantom was used to mimic tissue and microbubbles backscatters. For several regions of interest and for different microbbubles concentration, the RF signals have been generated at 3 and 5 transmit cycles. The received echoes have been filtered around the center frequency (fundamental) and around twice the center frequency (2nd harmonic). Obtained signals have been analyzed in order to evaluate Nakagami parameter (m), the scaling parameter (0) and the probability density function of the envelopes of the echo signals. These results would be used for improving the quality of images obtained by harmonic imagery.
- 1 July 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 852-855
Nonlinear characterization of tissue and microbubbles using Nakagami statistical model
The objective of this study is to exploit the statistical signatures of biological tissues and contrast microbubbles in order to develop new strategies for contrast imaging and tissue characterization. For this purpose, the Nakagami statistical model was chosen, because it is more general and simpler to apply than other statistical models to describe the linear and nonlinear ultrasonic echoes of both contrast microbubbles and tissues. Experiments were performed using a 2.5 MHz linear array connected to an open research platform. A commercially phantom was used to mimic tissue and microbubbles backscatters. For several regions of interest and for different microbbubles concentration, the RF signals have been generated at 3 and 5 transmit cycles. The received echoes have been filtered around the center frequency (fundamental) and around twice the center frequency (2nd harmonic). Obtained signals have been analyzed in order to evaluate Nakagami parameter (m), the scaling parameter (0) and the probability density function of the envelopes of the echo signals. These results would be used for improving the quality of images obtained by harmonic imagery.
- 1 April 2013
- Published by Trans Tech Publications, Ltd. in Advanced Materials Research
- Vol. 682, 85-95
Resonant Scattering and Absolute Phase Applied to Cylindrical and Spherical Hollow Fluids Embedded in an Elastic Medium: A Numerical Simulation
This paper is based on the study of acoustic scattering classic RST, in which it was introduced the method of MRST (multichannel resonant scattering theory) to study the problem of interaction of acoustic waves normal incidence in environments consisting of a biphasic isotropic elastic matrix in which is inserted a fluid inclusion (cylindrical or spherical). Initially we implement the transition matrix S containing the mode n of the longitudinal (L) and transverse (T) of the wave in the elastic medium. The isolation of resonances characteristic of the fluid inclusion is done via the S-matrix factorization as a product of the matrix of soft bottoms no resonant matrix and resonances. To improve the localization of the resonances we undertake a study of the absolute phase in connection with MRST. A numerical simulation of cavity fluid (water) cylindrical and spherical copper in a matrix, showed the effectiveness of the absolute phase spectra for the exact determination of the resonances.
- 1 April 2013
- Published by Trans Tech Publications, Ltd. in Advanced Materials Research
- Vol. 682, 85-95
Resonant Scattering and Absolute Phase Applied to Cylindrical and Spherical Hollow Fluids Embedded in an Elastic Medium: A Numerical Simulation
This paper is based on the study of acoustic scattering classic RST, in which it was introduced the method of MRST (multichannel resonant scattering theory) to study the problem of interaction of acoustic waves normal incidence in environments consisting of a biphasic isotropic elastic matrix in which is inserted a fluid inclusion (cylindrical or spherical). Initially we implement the transition matrix S containing the mode n of the longitudinal (L) and transverse (T) of the wave in the elastic medium. The isolation of resonances characteristic of the fluid inclusion is done via the S-matrix factorization as a product of the matrix of soft bottoms no resonant matrix and resonances. To improve the localization of the resonances we undertake a study of the absolute phase in connection with MRST. A numerical simulation of cavity fluid (water) cylindrical and spherical copper in a matrix, showed the effectiveness of the absolute phase spectra for the exact determination of the resonances.
- 1 December 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 21591660,p. 1-4
Use of Nakagami statistical model in ultrasonic tissue mimicking phantoms characterization
In order to improve tissue characterization, the probability density function of ultrasonic backscattered echoes which may be treated as random signals, is modeled using Nakagami statistical distribution. Recently, it has been shown that Nakagami statistical model constitutes a quite good model for tissue characterization due to its simplicity and general character. Experiments were performed using a 5MHz linear array connected to a 128 individual channels open research platform (M2M, Les Ulis, France) equipped with individual analog transmitters. Ultrasound images and corresponding RF signals were acquired at different transmit frequencies ranging from 2 to 6 MHz. Transmitted signals had frequency bandwidths of 80 to 90 %. A commercially available phantom was used to mimic tissue backscattering. The analysis was performed on different sizes and locations of the sampling window. The received echoes have been filtered around the transmitted center frequency and around twice the transmitted frequency (2nd harmonic). Acquired RF signals have been analyzed in order to evaluate Nakagami parameter (m), the scaling parameter (Ω) and the probability density function (PDF). These latter results have been compared to those obtained by using Field II software.
- 1 December 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 21591660,p. 1-4
Use of Nakagami statistical model in ultrasonic tissue mimicking phantoms characterization
In order to improve tissue characterization, the probability density function of ultrasonic backscattered echoes which may be treated as random signals, is modeled using Nakagami statistical distribution. Recently, it has been shown that Nakagami statistical model constitutes a quite good model for tissue characterization due to its simplicity and general character. Experiments were performed using a 5MHz linear array connected to a 128 individual channels open research platform (M2M, Les Ulis, France) equipped with individual analog transmitters. Ultrasound images and corresponding RF signals were acquired at different transmit frequencies ranging from 2 to 6 MHz. Transmitted signals had frequency bandwidths of 80 to 90 %. A commercially available phantom was used to mimic tissue backscattering. The analysis was performed on different sizes and locations of the sampling window. The received echoes have been filtered around the transmitted center frequency and around twice the transmitted frequency (2nd harmonic). Acquired RF signals have been analyzed in order to evaluate Nakagami parameter (m), the scaling parameter (Ω) and the probability density function (PDF). These latter results have been compared to those obtained by using Field II software.
- 1 October 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Propagation of Lamb waves on an immersed plate containing a periodic grating: Experimental study
In this paper the propagation of Lamb waves in an aluminum plate with a roughness on only one side is studied. The interaction between the incident Lamb wave and the grating gives rise to reflected converted waves. This phenomenon is studied experimentally in the case of an immersed plate in water. Our objective is to show that retro-converted waves radiating into the water are detectable although their energies are small. The damping coefficient of the propagating Lamb wave in the plate is evaluated. Preliminary numerical simulation by using a finite elements method is performed in order to help experiments.
- 1 October 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Propagation of Lamb waves on an immersed plate containing a periodic grating: Experimental study
In this paper the propagation of Lamb waves in an aluminum plate with a roughness on only one side is studied. The interaction between the incident Lamb wave and the grating gives rise to reflected converted waves. This phenomenon is studied experimentally in the case of an immersed plate in water. Our objective is to show that retro-converted waves radiating into the water are detectable although their energies are small. The damping coefficient of the propagating Lamb wave in the plate is evaluated. Preliminary numerical simulation by using a finite elements method is performed in order to help experiments.