Youssef Adel
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Youssef Adel has a total of 47 co-authors. Here are the top co-authors by number of shared publications:
- Uwe Baumann
Affiliation ENT/Audiological Acoustics, University Hospital, Goethe University Frankfurt, Frankfurt am Main, Germany
9 shared publications Tobias Weissgerber
Audiological Acoustics, Department of Otorhinolaryngology, University Hospital Frankfurt, Frankfurt am Main, Germany
6 shared publications- Tobias Rader
Department for Otorhinolaryngology, University Hospital, Ludwig-Maximilians-Universität München, Munich, Germany
5 shared publications Timo Stöver
Univ Hosp Frankfurt, Dept Otolaryngol Head & Neck Surg, Theodor Stern Kai 7, D-60590 Frankfurt, Germany
4 shared publicationsSilke Helbig
Univ Hosp Frankfurt, Dept Otolaryngol Head & Neck Surg, Theodor Stern Kai 7, D-60590 Frankfurt, Germany
3 shared publications- Barbara Peixoto Pinheiro
Translational Hearing Research, Tübingen Hearing Research Center, Department of Otolaryngology, Head and Neck Surgery, University of Tübingen, Tübingen, Germany
2 shared publications
Latest Publications
- Open Access
- 11 July 2022
- Published by Springer Nature in Cell Death & Disease
- Vol. 13 (7) , 1-9
A potassium channel agonist protects hearing function and promotes outer hair cell survival in a mouse model for age-related hearing loss
Age-related hearing loss (ARHL) is the most common sensory impairment mainly caused by degeneration of sensory hair cells in the cochlea with no causal medical treatment available. Auditory function and sensory hair cell survival critically depend on the Kv7.4 (KCNQ4) channel, a voltage-gated potassium channel expressed in outer hair cells (OHCs), with its impaired function or reduced activity previously associated with ARHL. Here, we investigated the effect of a potent small-molecule Kv7.4 agonist on ARHL in the senescence-accelerated mouse prone 8 (SAMP8) model. For the first time in vivo, we show that Kv7.4 activation can significantly reduce age-related threshold shifts of auditory brainstem responses as well as OHC loss in the SAMP8 model. Pharmacological activation of Kv7.4 thus holds great potential as a therapeutic approach for ARHL as well as other hearing impairments related to Kv7.4 function.
- 11 July 2022
- Published by Springer Nature in Cell Death & Disease
- Vol. 13 (7) , 1-9
Open AccessA potassium channel agonist protects hearing function and promotes outer hair cell survival in a mouse model for age-related hearing loss
Age-related hearing loss (ARHL) is the most common sensory impairment mainly caused by degeneration of sensory hair cells in the cochlea with no causal medical treatment available. Auditory function and sensory hair cell survival critically depend on the Kv7.4 (KCNQ4) channel, a voltage-gated potassium channel expressed in outer hair cells (OHCs), with its impaired function or reduced activity previously associated with ARHL. Here, we investigated the effect of a potent small-molecule Kv7.4 agonist on ARHL in the senescence-accelerated mouse prone 8 (SAMP8) model. For the first time in vivo, we show that Kv7.4 activation can significantly reduce age-related threshold shifts of auditory brainstem responses as well as OHC loss in the SAMP8 model. Pharmacological activation of Kv7.4 thus holds great potential as a therapeutic approach for ARHL as well as other hearing impairments related to Kv7.4 function.
- Open Access
- 1 February 2022
- Published by Elsevier in Hearing Research
- Vol. 414, 108391
Phoenix auditory neurons as 3R cell model for high throughput screening of neurogenic compounds
- 1 February 2022
- Published by Elsevier in Hearing Research
- Vol. 414, 108391
Open AccessPhoenix auditory neurons as 3R cell model for high throughput screening of neurogenic compounds
- Open Access
- 17 December 2020
- Published by Springer Nature in Pflügers Archiv - European Journal of Physiology
- Vol. 473 (5) , 823-840
Age-related hearing loss pertaining to potassium ion channels in the cochlea and auditory pathway
Age-related hearing loss (ARHL) is the most prevalent sensory deficit in the elderly and constitutes the third highest risk factor for dementia. Lifetime noise exposure, genetic predispositions for degeneration, and metabolic stress are assumed to be the major causes of ARHL. Both noise-induced and hereditary progressive hearing have been linked to decreased cell surface expression and impaired conductance of the potassium ion channel KV7.4 (KCNQ4) in outer hair cells, inspiring future therapies to maintain or prevent the decline of potassium ion channel surface expression to reduce ARHL. In concert with KV7.4 in outer hair cells, KV7.1 (KCNQ1) in the stria vascularis, calcium-activated potassium channels BK (KCNMA1) and SK2 (KCNN2) in hair cells and efferent fiber synapses, and KV3.1 (KCNC1) in the spiral ganglia and ascending auditory circuits share an upregulated expression or subcellular targeting during final differentiation at hearing onset. They also share a distinctive fragility for noise exposure and age-dependent shortfalls in energy supply required for sustained surface expression. Here, we review and discuss the possible contribution of select potassium ion channels in the cochlea and auditory pathway to ARHL. We postulate genes, proteins, or modulators that contribute to sustained ion currents or proper surface expressions of potassium channels under challenging conditions as key for future therapies of ARHL.
- 17 December 2020
- Published by Springer Nature in Pflügers Archiv - European Journal of Physiology
- Vol. 473 (5) , 823-840
Open AccessAge-related hearing loss pertaining to potassium ion channels in the cochlea and auditory pathway
Age-related hearing loss (ARHL) is the most prevalent sensory deficit in the elderly and constitutes the third highest risk factor for dementia. Lifetime noise exposure, genetic predispositions for degeneration, and metabolic stress are assumed to be the major causes of ARHL. Both noise-induced and hereditary progressive hearing have been linked to decreased cell surface expression and impaired conductance of the potassium ion channel KV7.4 (KCNQ4) in outer hair cells, inspiring future therapies to maintain or prevent the decline of potassium ion channel surface expression to reduce ARHL. In concert with KV7.4 in outer hair cells, KV7.1 (KCNQ1) in the stria vascularis, calcium-activated potassium channels BK (KCNMA1) and SK2 (KCNN2) in hair cells and efferent fiber synapses, and KV3.1 (KCNC1) in the spiral ganglia and ascending auditory circuits share an upregulated expression or subcellular targeting during final differentiation at hearing onset. They also share a distinctive fragility for noise exposure and age-dependent shortfalls in energy supply required for sustained surface expression. Here, we review and discuss the possible contribution of select potassium ion channels in the cochlea and auditory pathway to ARHL. We postulate genes, proteins, or modulators that contribute to sustained ion currents or proper surface expressions of potassium channels under challenging conditions as key for future therapies of ARHL.
- 8 July 2020
- Published by Wolters Kluwer Health in Ear & Hearing
- Vol. 42 (1) , 142-162
Band-Limited Chirp-Evoked Compound Action Potential in Guinea Pig: Comprehensive Neural Measure for Cochlear Implantation Monitoring
Objectives: Patients with severely impaired high-frequency hearing and sufficient residual low-frequency hearing can be provided with a cochlear implant (CI), thereby facilitating ipsilateral electric and acoustic stimulation with established advantages over electric stimulation alone. However, partial or complete hearing loss often occurred after implantation due to, inter alia, acute mechanical trauma to cochlear structures during electrode insertion. Possibilities of intraoperative monitoring using electrocochleography (ECochG) have recently been studied in CI patients, primarily using the ongoing response to low-frequency tone bursts consisting of the cochlear microphonic (CM) and the auditory nerve neurophonic. By contrast, the transient neural response to tone bursts, that is, compound action potential (CAP), was generally less detectable or less sensitive as a monitoring measure, thus falling short of providing useful contribution to electrocochleography analysis. In this study, we investigate using chirps to evoke more robust CAP responses in a limited frequency band by synchronizing neural firing, and thereby improving CAP sensitivity to mechanical trauma in a guinea pig model of cochlear implantation. Design: Stimuli were band-limited between 100 Hz and 10 kHz to investigate their frequency range selectivity as a preliminary model for low-frequency hearing. They were constructed by adding a harmonic series either with zero phase delay (click) or by adjusting the phase delay at a rate that is inversely related to a traveling wave delay model (chirp), with three different parameters to examine level-dependent delay compression. The amplitude spectrum was thus identical between stimuli with differences only in phase. In Experiment 1, we compared input-output functions recorded at the round window in normal-hearing guinea pigs and implemented a high-pass noise masking paradigm to infer neural contribution to the CAP. In Experiment 2, guinea pigs were implanted with a custom-built CI electrode using a motorized micromanipulator. Acute mechanical trauma was simulated during the electrode insertion. At each insertion step, CAP and CM responses were measured at the round window for the following stimuli: broad-band click, band-limited click, and band-limited chirps (3 parameters), and tone bursts at frequencies 1, 2, 4, and 8 kHz. Results: Chirps compared with the equal-band click showed significantly lower thresholds and steeper slopes of sigmoid-fitted input-output functions. The shorter chirp evoked significantly larger amplitudes than click when compared at equal sensation level. However, the click evoked larger amplitudes than chirps at higher levels and correspondingly achieved larger saturation amplitudes. The results of the high-pass noise masking paradigm suggest that chirps could efficiently synchronize neural firing in their targeted frequency band, while the click recruited more basal fibers outside its limited band. Finally, monitoring sensitivity during electrode insertion, defined as relative amplitude change per unit distance, was higher for chirp-evoked CAP and tone burst-evoked CM, but smaller for CAP responses evoked by clicks or tone bursts. Conclusion: The chirp was shown to be an efficient stimulus in synchronizing neural firing for a limited frequency band in the guinea pig model. This study provides a proof of principle for using chirp-evoked CAP as a comprehensive neural measure in CI patients with residual hearing.
- 8 July 2020
- Published by Wolters Kluwer Health in Ear & Hearing
- Vol. 42 (1) , 142-162
Band-Limited Chirp-Evoked Compound Action Potential in Guinea Pig: Comprehensive Neural Measure for Cochlear Implantation Monitoring
Objectives: Patients with severely impaired high-frequency hearing and sufficient residual low-frequency hearing can be provided with a cochlear implant (CI), thereby facilitating ipsilateral electric and acoustic stimulation with established advantages over electric stimulation alone. However, partial or complete hearing loss often occurred after implantation due to, inter alia, acute mechanical trauma to cochlear structures during electrode insertion. Possibilities of intraoperative monitoring using electrocochleography (ECochG) have recently been studied in CI patients, primarily using the ongoing response to low-frequency tone bursts consisting of the cochlear microphonic (CM) and the auditory nerve neurophonic. By contrast, the transient neural response to tone bursts, that is, compound action potential (CAP), was generally less detectable or less sensitive as a monitoring measure, thus falling short of providing useful contribution to electrocochleography analysis. In this study, we investigate using chirps to evoke more robust CAP responses in a limited frequency band by synchronizing neural firing, and thereby improving CAP sensitivity to mechanical trauma in a guinea pig model of cochlear implantation. Design: Stimuli were band-limited between 100 Hz and 10 kHz to investigate their frequency range selectivity as a preliminary model for low-frequency hearing. They were constructed by adding a harmonic series either with zero phase delay (click) or by adjusting the phase delay at a rate that is inversely related to a traveling wave delay model (chirp), with three different parameters to examine level-dependent delay compression. The amplitude spectrum was thus identical between stimuli with differences only in phase. In Experiment 1, we compared input-output functions recorded at the round window in normal-hearing guinea pigs and implemented a high-pass noise masking paradigm to infer neural contribution to the CAP. In Experiment 2, guinea pigs were implanted with a custom-built CI electrode using a motorized micromanipulator. Acute mechanical trauma was simulated during the electrode insertion. At each insertion step, CAP and CM responses were measured at the round window for the following stimuli: broad-band click, band-limited click, and band-limited chirps (3 parameters), and tone bursts at frequencies 1, 2, 4, and 8 kHz. Results: Chirps compared with the equal-band click showed significantly lower thresholds and steeper slopes of sigmoid-fitted input-output functions. The shorter chirp evoked significantly larger amplitudes than click when compared at equal sensation level. However, the click evoked larger amplitudes than chirps at higher levels and correspondingly achieved larger saturation amplitudes. The results of the high-pass noise masking paradigm suggest that chirps could efficiently synchronize neural firing in their targeted frequency band, while the click recruited more basal fibers outside its limited band. Finally, monitoring sensitivity during electrode insertion, defined as relative amplitude change per unit distance, was higher for chirp-evoked CAP and tone burst-evoked CM, but smaller for CAP responses evoked by clicks or tone bursts. Conclusion: The chirp was shown to be an efficient stimulus in synchronizing neural firing for a limited frequency band in the guinea pig model. This study provides a proof of principle for using chirp-evoked CAP as a comprehensive neural measure in CI patients with residual hearing.
- Open Access
- 1 November 2019
- Published by Frontiers Media SA in Frontiers in Neuroscience
- Vol. 13, 1119
Pitch Matching in Cochlear Implant Users With Single-Sided Deafness: Effects of Electrode Position and Acoustic Stimulus Type
Previous studies in patients with single-sided deafness (SSD) have reported results of pitch comparisons between electric stimulation of their cochlear implant (CI) and acoustic stimulation presented to their near-normal hearing contralateral ear. These comparisons typically used sinusoids, although the percept elicited by electric stimulation may be closer to a wideband stimulus. Furthermore, it has been shown that pitch comparisons between sounds with different timbres is a difficult task and subjected to various types of range biases. The present study aims to introduce a method to minimize non-sensory biases, and to investigate the effect of different acoustic stimulus types on the frequency and variability of the electric-acoustic pitch matches. Pitch matches were collected from 13 CI users with SSD using the binary search procedure. Electric stimulation was presented at either an apical or a middle electrode position, at a rate of 800 pps. Acoustic stimulus types were sinusoids (SINE), 1/3-octave wide narrow bands of Gaussian noises (NBN), or 1/3-octave wide pulse spreading harmonic complexes (PSHC). On the one hand, NBN and PSHC are presumed to better mimic the spread of excitation produced by a single-electrode stimulation than SINE. On the other hand, SINE and PSHC contain less inherent fluctuations than NBN and may therefore provide a temporal pattern closer to that produced by a constant-amplitude electric pulse train. Analysis of mean pitch match variance showed no differences between stimulus types. However, mean pitch matches showed effects of electrode position and stimulus type, with the middle electrode always matched to a higher frequency than the apical one (p < 0.001), and significantly higher across-subject pitch matches for PSHC compared with SINE (p = 0.017). Mean pitch matches for all stimulus types were better predicted by place-dependent characteristic frequencies (CFs) based on an organ of Corti map compared with a spiral ganglion map. CF predictions were closest to pitch matches with SINE for the apical electrode position, and conversely with NBN or PSHC for the middle electrode position. These results provide evidence that the choice of acoustic stimulus type can have a significant effect on electric-acoustic pitch matching.
- 1 November 2019
- Published by Frontiers Media SA in Frontiers in Neuroscience
- Vol. 13, 1119
Open AccessPitch Matching in Cochlear Implant Users With Single-Sided Deafness: Effects of Electrode Position and Acoustic Stimulus Type
Previous studies in patients with single-sided deafness (SSD) have reported results of pitch comparisons between electric stimulation of their cochlear implant (CI) and acoustic stimulation presented to their near-normal hearing contralateral ear. These comparisons typically used sinusoids, although the percept elicited by electric stimulation may be closer to a wideband stimulus. Furthermore, it has been shown that pitch comparisons between sounds with different timbres is a difficult task and subjected to various types of range biases. The present study aims to introduce a method to minimize non-sensory biases, and to investigate the effect of different acoustic stimulus types on the frequency and variability of the electric-acoustic pitch matches. Pitch matches were collected from 13 CI users with SSD using the binary search procedure. Electric stimulation was presented at either an apical or a middle electrode position, at a rate of 800 pps. Acoustic stimulus types were sinusoids (SINE), 1/3-octave wide narrow bands of Gaussian noises (NBN), or 1/3-octave wide pulse spreading harmonic complexes (PSHC). On the one hand, NBN and PSHC are presumed to better mimic the spread of excitation produced by a single-electrode stimulation than SINE. On the other hand, SINE and PSHC contain less inherent fluctuations than NBN and may therefore provide a temporal pattern closer to that produced by a constant-amplitude electric pulse train. Analysis of mean pitch match variance showed no differences between stimulus types. However, mean pitch matches showed effects of electrode position and stimulus type, with the middle electrode always matched to a higher frequency than the apical one (p < 0.001), and significantly higher across-subject pitch matches for PSHC compared with SINE (p = 0.017). Mean pitch matches for all stimulus types were better predicted by place-dependent characteristic frequencies (CFs) based on an organ of Corti map compared with a spiral ganglion map. CF predictions were closest to pitch matches with SINE for the apical electrode position, and conversely with NBN or PSHC for the middle electrode position. These results provide evidence that the choice of acoustic stimulus type can have a significant effect on electric-acoustic pitch matching.
- 1 November 2019
- Published by Springer Nature in European Archives of Oto-Rhino-Laryngology
- Vol. 277 (2) , 385-392
Evaluation of a bone groove geometry for fixation of a cochlear implant electrode
Purpose Electrode migration is a rare, but relevant complication in cochlear implant (CI) surgery. An effective countermeasure is to create a bone groove in the facial recess to secure the electrode lead. We use this method routinely since 2013, but still experienced sporadic electrode migration events most likely due to an improper surgical execution. The aim of this study was to determine the optimum groove geometry. Methods Grooves of defined geometry were created in specimens of fresh porcine femur compacta by use of a CNC milling machine. Electrode dummies were fixed in the groove and then exposed to tensile stress. Force measurements were carried out to examine the effect of groove diameter and opening width on the holding force. The mechanical impact on the electrode cable during insertion into the groove was recorded and the electrode lead was examined under microscopic magnification to assess potential structural damage. Results Optimum groove geometry (diameter 1.10 mm, opening width 0.90 mm) ensured an average holding force of 830 mN which is equivalent to the established fixation by use of a titanium clip. None of the microscopic inspections revealed any morphological deterioration of the electrode lead. Conclusion The fixation of a CI electrode in a bone groove in the facial recess appears to be effective and safe. Furthermore, this method does not require additional costs or foreign material. The optimum geometry defined in this study helped us to refine our surgical standard produce and to generate more consistent results.
- 1 November 2019
- Published by Springer Nature in European Archives of Oto-Rhino-Laryngology
- Vol. 277 (2) , 385-392
Evaluation of a bone groove geometry for fixation of a cochlear implant electrode
Purpose Electrode migration is a rare, but relevant complication in cochlear implant (CI) surgery. An effective countermeasure is to create a bone groove in the facial recess to secure the electrode lead. We use this method routinely since 2013, but still experienced sporadic electrode migration events most likely due to an improper surgical execution. The aim of this study was to determine the optimum groove geometry. Methods Grooves of defined geometry were created in specimens of fresh porcine femur compacta by use of a CNC milling machine. Electrode dummies were fixed in the groove and then exposed to tensile stress. Force measurements were carried out to examine the effect of groove diameter and opening width on the holding force. The mechanical impact on the electrode cable during insertion into the groove was recorded and the electrode lead was examined under microscopic magnification to assess potential structural damage. Results Optimum groove geometry (diameter 1.10 mm, opening width 0.90 mm) ensured an average holding force of 830 mN which is equivalent to the established fixation by use of a titanium clip. None of the microscopic inspections revealed any morphological deterioration of the electrode lead. Conclusion The fixation of a CI electrode in a bone groove in the facial recess appears to be effective and safe. Furthermore, this method does not require additional costs or foreign material. The optimum geometry defined in this study helped us to refine our surgical standard produce and to generate more consistent results.
- 1 June 2019
- Published by Wolters Kluwer Health in Otology & Neurotology
- Vol. 40 (5) , e511-e517
The Effect of a Bone Groove Against Cochlear Implant Electrode Migration
Hypothesis: The risk of electrode migration in cochlear implant (CI) surgery can be reduced by securing the electrode lead in a bone groove in the chorda-facial angle. Background: Electrode migration is an important complication in CI surgery, which affects hearing performance, may induce pain and facial nerve stimulation, and requires surgical revision. A potential method to secure the electrode is to use a bone groove created in the facial recess to fixate the electrode lead. This surgical measure is a standard procedure for lateral wall electrodes (LWE) in our clinic since 2013. Methods: Retrospective analysis of consecutive CI cases of a tertiary referral center from 2006 to 2016 and comparison of incidence rates between group A (without bone groove, years 2006-2012) and group B (with bone groove fixation, years 2013-2016). Clinical cases were reviewed with respect to electrode type, migration length, time interval to migration, and findings during revision surgery. Results: Seventeen cases of electrode migration were found in a total of 1,603 cochlear implantations. Only LWE designs were affected by migration. The cumulative incidence for LWE in group B (0.5%) was significantly lower than in group A (3.7%, p < 0.01). The two migration cases in group B revealed insufficient geometric design of the bone grooves. Only one patient experienced a remigration after revision surgery. Conclusion: The fixation in a bone groove in the chordafacial angle is an effective measure against migration of LWE. Proper surgical execution is mandatory to ensure a tight and enduring fit.
- 1 June 2019
- Published by Wolters Kluwer Health in Otology & Neurotology
- Vol. 40 (5) , e511-e517
The Effect of a Bone Groove Against Cochlear Implant Electrode Migration
Hypothesis: The risk of electrode migration in cochlear implant (CI) surgery can be reduced by securing the electrode lead in a bone groove in the chorda-facial angle. Background: Electrode migration is an important complication in CI surgery, which affects hearing performance, may induce pain and facial nerve stimulation, and requires surgical revision. A potential method to secure the electrode is to use a bone groove created in the facial recess to fixate the electrode lead. This surgical measure is a standard procedure for lateral wall electrodes (LWE) in our clinic since 2013. Methods: Retrospective analysis of consecutive CI cases of a tertiary referral center from 2006 to 2016 and comparison of incidence rates between group A (without bone groove, years 2006-2012) and group B (with bone groove fixation, years 2013-2016). Clinical cases were reviewed with respect to electrode type, migration length, time interval to migration, and findings during revision surgery. Results: Seventeen cases of electrode migration were found in a total of 1,603 cochlear implantations. Only LWE designs were affected by migration. The cumulative incidence for LWE in group B (0.5%) was significantly lower than in group A (3.7%, p < 0.01). The two migration cases in group B revealed insufficient geometric design of the bone grooves. Only one patient experienced a remigration after revision surgery. Conclusion: The fixation in a bone groove in the chordafacial angle is an effective measure against migration of LWE. Proper surgical execution is mandatory to ensure a tight and enduring fit.
- 1 August 2018
- Published by Wolters Kluwer Health in Otology & Neurotology
- Vol. 39 (7) , 834-841
Hearing Preservation Outcomes After Cochlear Implantation Depending on the Angle of Insertion: Indication for Electric or Electric-Acoustic Stimulation
Objective: This study reviewed outcomes of hearing preservation (HP) surgery depending on the angle of insertion (AOI) in a cochlear implant (CI) patient population who used electric stimulation (ES) or combined electric-acoustic stimulation (EAS). Study Design: Retrospective case review. Setting: Tertiary referral university hospital. Patients: Ninety-one patients with different degrees of preoperative low-frequency residual hearing who underwent HP surgery with a free-fitting lateral-wall electrode array (MED-EL Flex) with lengths ranging from 20.0 to 31.5 mm. Intervention: Cochlear implantation using HP surgery technique and subsequent fitting with CI speech processor for ES, or combined CI and hearing aid speech processor for EAS. Main Outcome Measures: Individual AOI were estimated using modified Stenvers’ projection. Freiburg monosyllable test in quiet (free-field presentation at 65 dB SPL) and pure-tone averages for low frequencies (125, 250, and 500 Hz; PTAlow) were evaluated during a follow-up period of 12 months after implantation. Results: Estimated AOIs showed bimodal distribution: shallow insertion (SI) with mean AOI of 377 degrees and deep insertion (DI) with mean AOI of 608 degrees. Speech test scores after 12 months were comparable between AOI groups, however, they were significantly different between stimulation types with better scores for EAS. Only ES showed a positive correlation (r = 0.293) between speech test score and AOI. When HP was possible, both SI and DI showed significant postoperative PTAlow shifts with mean of 17.8 and 21.6 dB, respectively. These were comparable between AOI groups and no significant shifts were observed in follow-up intervals. Audiometric indication for HP and subsequent EAS is proposed up to 65 dB HL at 500 Hz, and up to 87 dB HL for HP. Conclusions: CI candidates can benefit from HP surgery with deep insertion when only using ES due to insufficient residual hearing. Conversely, candidates with preoperative threshold up to 65 dB HL at 500 Hz could perform significantly better with EAS which requires shallow insertion.
- 1 August 2018
- Published by Wolters Kluwer Health in Otology & Neurotology
- Vol. 39 (7) , 834-841
Hearing Preservation Outcomes After Cochlear Implantation Depending on the Angle of Insertion: Indication for Electric or Electric-Acoustic Stimulation
Objective: This study reviewed outcomes of hearing preservation (HP) surgery depending on the angle of insertion (AOI) in a cochlear implant (CI) patient population who used electric stimulation (ES) or combined electric-acoustic stimulation (EAS). Study Design: Retrospective case review. Setting: Tertiary referral university hospital. Patients: Ninety-one patients with different degrees of preoperative low-frequency residual hearing who underwent HP surgery with a free-fitting lateral-wall electrode array (MED-EL Flex) with lengths ranging from 20.0 to 31.5 mm. Intervention: Cochlear implantation using HP surgery technique and subsequent fitting with CI speech processor for ES, or combined CI and hearing aid speech processor for EAS. Main Outcome Measures: Individual AOI were estimated using modified Stenvers’ projection. Freiburg monosyllable test in quiet (free-field presentation at 65 dB SPL) and pure-tone averages for low frequencies (125, 250, and 500 Hz; PTAlow) were evaluated during a follow-up period of 12 months after implantation. Results: Estimated AOIs showed bimodal distribution: shallow insertion (SI) with mean AOI of 377 degrees and deep insertion (DI) with mean AOI of 608 degrees. Speech test scores after 12 months were comparable between AOI groups, however, they were significantly different between stimulation types with better scores for EAS. Only ES showed a positive correlation (r = 0.293) between speech test score and AOI. When HP was possible, both SI and DI showed significant postoperative PTAlow shifts with mean of 17.8 and 21.6 dB, respectively. These were comparable between AOI groups and no significant shifts were observed in follow-up intervals. Audiometric indication for HP and subsequent EAS is proposed up to 65 dB HL at 500 Hz, and up to 87 dB HL for HP. Conclusions: CI candidates can benefit from HP surgery with deep insertion when only using ES due to insufficient residual hearing. Conversely, candidates with preoperative threshold up to 65 dB HL at 500 Hz could perform significantly better with EAS which requires shallow insertion.
- 1 February 2018
- Published by Taylor & Francis in International Journal of Audiology
- Vol. 57 (7) , 502-509
A method for determining precise electrical hearing thresholds in cochlear implant users
Objective: A psychoacoustic procedure designed for the precise assessment of perceptional threshold (T-level) in cochlear implant (CI) users is presented. The impact of this procedure on speech perception was investigated. Design: Individual T-level measurements were obtained with the proposed procedure and three different speech processor fitting conditions were applied: (1) fitting familiar to the subject, T-levels unchanged, (2) T-level set to thresholds determined with the new procedure, (3) T-level set to thresholds determined with the new procedure, but T-level is decreased by 10 clinical units (CU). The impact of the different fitting conditions was measured by means of categorical loudness scaling (CLS) and speech perception tests in quiet and noise. Study sample: A prospective study at a tertiary referral university hospital. 18 experienced postlingually deafened cochlear implanted adult subjects. Results: Average sound-field thresholds obtained by CLS were lowest in condition using the new procedure yielding a larger dynamic range with significantly higher speech scores in quiet compared to those with a subject’s commonly used programme, and significantly improved in noise even after reducing T-levels by 10 CU. Conclusion: The precise determination of T-levels by means of the proposed procedure improved performance in several speech recognition tasks. Compared to the default behavioural setting, T-level increased on median by 9 CU. Average speech reception threshold in noise for soft speech levels (50 dB sound pressure level) decreased by 1 dB.
- 1 February 2018
- Published by Taylor & Francis in International Journal of Audiology
- Vol. 57 (7) , 502-509
A method for determining precise electrical hearing thresholds in cochlear implant users
Objective: A psychoacoustic procedure designed for the precise assessment of perceptional threshold (T-level) in cochlear implant (CI) users is presented. The impact of this procedure on speech perception was investigated. Design: Individual T-level measurements were obtained with the proposed procedure and three different speech processor fitting conditions were applied: (1) fitting familiar to the subject, T-levels unchanged, (2) T-level set to thresholds determined with the new procedure, (3) T-level set to thresholds determined with the new procedure, but T-level is decreased by 10 clinical units (CU). The impact of the different fitting conditions was measured by means of categorical loudness scaling (CLS) and speech perception tests in quiet and noise. Study sample: A prospective study at a tertiary referral university hospital. 18 experienced postlingually deafened cochlear implanted adult subjects. Results: Average sound-field thresholds obtained by CLS were lowest in condition using the new procedure yielding a larger dynamic range with significantly higher speech scores in quiet compared to those with a subject’s commonly used programme, and significantly improved in noise even after reducing T-levels by 10 CU. Conclusion: The precise determination of T-levels by means of the proposed procedure improved performance in several speech recognition tasks. Compared to the default behavioural setting, T-level increased on median by 9 CU. Average speech reception threshold in noise for soft speech levels (50 dB sound pressure level) decreased by 1 dB.
- 1 December 2017
- Published by Wolters Kluwer Health in Otology & Neurotology
- Vol. 38 (10) , e438-e444
Preventing Facial Nerve Stimulation by Triphasic Pulse Stimulation in Cochlear Implant Users: Intraoperative Recordings
Hypothesis: Triphasic pulse stimulation of the auditory nerve can prevent unintended facial nerve stimulation (FNS) due to a different electromyographic (EMG) input–output function compared with biphasic pulses. Background: FNS is sometimes observed in cochlear implant (CI) users as an unpleasant side effect of electrical stimulation using biphasic pulse patterns (BPP). Clinical remedies to alleviate FNS are 1) to extend stimulus phase duration or 2) to completely deactivate the electrode. In some cases, these options do not provide sufficient FNS reduction or are detrimental to subject performance. Stimulation using triphasic pulse patterns (TPP) has been shown to prevent FNS more effectively, yet the underlying mechanism remains unclear. Methods: EMG potentials of muscles innervated by the facial nerve (orbicularis oculi and oris muscles) were recorded to quantitatively compare the effect of BPP and TPP stimulation on FNS. Recordings were conducted in five subjects during CI surgery. In two exemplary cases, different leading phase polarities in alternating and non-alternating order were tested. Results: Compared with our previous study in awake patients using surface electrodes (Bahmer and Baumann, 2016), intraoperative recordings using subdermal electrodes showed lower noise content and allowed higher sampling resolution. While inter-subject variation remained high, intra-subject results for different electrode positions were comparable: FNS was strongly reduced for cathodic-first TPP stimulation. In contrast, exemplary cases showed little reduction for anodic-first TPP as well as for alternating stimulation. Conclusion: FNS in CI users can be reduced using TPP stimulation, but the ameliorative effect appears to be dependent on the leading stimulus polarity.
- 1 December 2017
- Published by Wolters Kluwer Health in Otology & Neurotology
- Vol. 38 (10) , e438-e444
Preventing Facial Nerve Stimulation by Triphasic Pulse Stimulation in Cochlear Implant Users: Intraoperative Recordings
Hypothesis: Triphasic pulse stimulation of the auditory nerve can prevent unintended facial nerve stimulation (FNS) due to a different electromyographic (EMG) input–output function compared with biphasic pulses. Background: FNS is sometimes observed in cochlear implant (CI) users as an unpleasant side effect of electrical stimulation using biphasic pulse patterns (BPP). Clinical remedies to alleviate FNS are 1) to extend stimulus phase duration or 2) to completely deactivate the electrode. In some cases, these options do not provide sufficient FNS reduction or are detrimental to subject performance. Stimulation using triphasic pulse patterns (TPP) has been shown to prevent FNS more effectively, yet the underlying mechanism remains unclear. Methods: EMG potentials of muscles innervated by the facial nerve (orbicularis oculi and oris muscles) were recorded to quantitatively compare the effect of BPP and TPP stimulation on FNS. Recordings were conducted in five subjects during CI surgery. In two exemplary cases, different leading phase polarities in alternating and non-alternating order were tested. Results: Compared with our previous study in awake patients using surface electrodes (Bahmer and Baumann, 2016), intraoperative recordings using subdermal electrodes showed lower noise content and allowed higher sampling resolution. While inter-subject variation remained high, intra-subject results for different electrode positions were comparable: FNS was strongly reduced for cathodic-first TPP stimulation. In contrast, exemplary cases showed little reduction for anodic-first TPP as well as for alternating stimulation. Conclusion: FNS in CI users can be reduced using TPP stimulation, but the ameliorative effect appears to be dependent on the leading stimulus polarity.