Luiz Vicente Gomes Tarelho
Luiz Vicente Gomes Tarelho has a total of 145 co-authors. Here are the top co-authors by number of shared publications:
- Lilia Coronato Courrol
Programa de Pós-Graduação em Ciências e Tecnologia da Sustentabilidade, Universidade Federal de São Paulo, Diadema, Brazil
11 shared publications L. Gomes
Centro de Lasers e Aplicações, IPEN-SP, Travessa R 400, Cidade Universitária, CEP 05508-900, São Paulo, Brazil
8 shared publicationsLaércio Gomes
Centro de Lasers e Aplicações, IPEN/CNEN-SP, São Paulo, SP -Brazil
7 shared publications- Daniel Varela Magalhaes
University of São Paulo
4 shared publications I. M. Ranieri
Centro de Lasers e Aplicações, IPEN-SP, Travessa R 400, Cidade Universitária, Caixa Postal 11049, CEP 05422-970, São Paulo, Brazil
4 shared publications- Anderson Zanardi de Freitas
Institute for Energy and Nuclear Research, São Paulo, Brazil, Brazil
3 shared publications
Latest Publications
- Open Access
- 18 May 2026
- Published by IMEKO International Measurement Confederation in ACTA IMEKO
- Vol. 15 (2) , 1-11
On the microvolume measurement from 0.1 μL up to 100 mL using a microsyringe and micropipette
This work focuses on the measurement of small liquid volumes, comparing results obtained using the gravimetric method with different resolutions. The main objective of this study is to characterize the behaviour of microsyringes and micropipettes during the measurement of microvolumes in the range between 0.1 and 1 µL using the gravimetric method, with metrological traceability, and compare the results in the range up to 100 µL. The methodology addresses the challenges associated with measurements below 1 µL by establishing metrological traceability through mass measurement using the gravimetric method. Given that the smallest standard weight is nominally 1 mg, relying solely on the dispensed liquid volume would result in a lack of metrological traceability for volumes under 1 µL. To enhance reliability, eleven independent measurements are taken at each volume point to calculate an average. The results are presented, to conclude the analysis, and simulations were conducted to explore potential improvements by employing a scale with a resolution of 0.001 mg, along with its associated measurement uncertainty.
- 18 May 2026
- Published by IMEKO International Measurement Confederation in ACTA IMEKO
- Vol. 15 (2) , 1-11
Open AccessOn the microvolume measurement from 0.1 μL up to 100 mL using a microsyringe and micropipette
This work focuses on the measurement of small liquid volumes, comparing results obtained using the gravimetric method with different resolutions. The main objective of this study is to characterize the behaviour of microsyringes and micropipettes during the measurement of microvolumes in the range between 0.1 and 1 µL using the gravimetric method, with metrological traceability, and compare the results in the range up to 100 µL. The methodology addresses the challenges associated with measurements below 1 µL by establishing metrological traceability through mass measurement using the gravimetric method. Given that the smallest standard weight is nominally 1 mg, relying solely on the dispensed liquid volume would result in a lack of metrological traceability for volumes under 1 µL. To enhance reliability, eleven independent measurements are taken at each volume point to calculate an average. The results are presented, to conclude the analysis, and simulations were conducted to explore potential improvements by employing a scale with a resolution of 0.001 mg, along with its associated measurement uncertainty.
- Open Access
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Selected Topics in Applied Earth Observations and Remote Sensing
- Vol. 19 (19391404) , 14533-14539
Real-Time Estimation of Tropospheric Delay Measurements Using a Low-Cost Weather Station Integrated With the Hopfield Model
This study presents preliminary results of the development of a meteorological microstation that calculates and can correct the tropospheric delay in the precise point positioning method with a global navigation satellite system (GNSS). Using the Hopfield model fed with atmospheric data collected by a BME280 sensor, zenith tropospheric delay (ZTD) was estimated based on temperature and pressure, and this ZTD was compared with the ZTD measured by GNSS signals processed on the UTC(LRTE) time scale. The tests were conducted over a period of 38 days using both the GPS and GLONASS satellite constellations. Time-series analysis confirms that models based on locally collected data reduced the noise amplitude associated with the GPS constellation by 98.74% and 99.67% for the GLONASS constellation, significantly improving the accuracy of applications that require high-precision positioning, as well as time and frequency synchronization.
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Selected Topics in Applied Earth Observations and Remote Sensing
- Vol. 19 (19391404) , 14533-14539
Open AccessReal-Time Estimation of Tropospheric Delay Measurements Using a Low-Cost Weather Station Integrated With the Hopfield Model
This study presents preliminary results of the development of a meteorological microstation that calculates and can correct the tropospheric delay in the precise point positioning method with a global navigation satellite system (GNSS). Using the Hopfield model fed with atmospheric data collected by a BME280 sensor, zenith tropospheric delay (ZTD) was estimated based on temperature and pressure, and this ZTD was compared with the ZTD measured by GNSS signals processed on the UTC(LRTE) time scale. The tests were conducted over a period of 38 days using both the GPS and GLONASS satellite constellations. Time-series analysis confirms that models based on locally collected data reduced the noise amplitude associated with the GPS constellation by 98.74% and 99.67% for the GLONASS constellation, significantly improving the accuracy of applications that require high-precision positioning, as well as time and frequency synchronization.
- 23 November 2024
- Published by Springer Nature in Quantum Information Processing
- Vol. 23 (11) , 1-12
Quantum random number generation using Quandela photonic quantum computer
- 23 November 2024
- Published by Springer Nature in Quantum Information Processing
- Vol. 23 (11) , 1-12
Quantum random number generation using Quandela photonic quantum computer
- Open Access
- 24 January 2024
- Published by Wiley
Ionosphere characterization using GPS P3 method by measuring ionospheric delay in Southeast of Brazil and considering geomagnetic storms.
Ionospheric refraction introduces significant delay and fading in the electromagnetic signals. This makes the ionosphere the most harmful layer of the Earth’s atmosphere to the electromagnetic signals emitted by satellites, impacting the reliability of GNSS services. Depending on the ionization level of the ionosphere plasma and the signal frequency, these errors can vary from a few meters to signal unavailability. The main factors influencing ionosphere plasma’s ionization level are the intensity of solar radiation and the Earth’s magnetic field. The main parameter to evaluate the behavior of the ionosphere is the Total Electron Content (TEC), existing between the satellite and the terrestrial receiver antenna. By predicting the TEC value, it is possible to predict the effects of ionospheric refraction and develop techniques to increase reliability in services that depend on GNSS. This study spans the four seasons from 2018 to 2023, utilizing measurements of ionospheric delays collected by the UTC(INXE). Daily, seasonal, and annual variations in Vertical TEC (VTEC) values are analyzed. A comparative assessment is made between the VTEC values obtained by the GPS P3 method and the Ionospheric Map method for each season until winter 2023. The Analysis of Variance demonstrated the compatibility and comparability of the two methods. Additionally, this investigation explores changes in the ionosphere behavior at the UTC(INXE) location during the geomagnetic storms caused by the solar explosions on April 21, 2023. The findings provide valuable insights for the ionosphere dynamics and can contribute to developing techniques to improve GNSS services’ reliability.
- 24 January 2024
- Published by Wiley
Open AccessIonosphere characterization using GPS P3 method by measuring ionospheric delay in Southeast of Brazil and considering geomagnetic storms.
Ionospheric refraction introduces significant delay and fading in the electromagnetic signals. This makes the ionosphere the most harmful layer of the Earth’s atmosphere to the electromagnetic signals emitted by satellites, impacting the reliability of GNSS services. Depending on the ionization level of the ionosphere plasma and the signal frequency, these errors can vary from a few meters to signal unavailability. The main factors influencing ionosphere plasma’s ionization level are the intensity of solar radiation and the Earth’s magnetic field. The main parameter to evaluate the behavior of the ionosphere is the Total Electron Content (TEC), existing between the satellite and the terrestrial receiver antenna. By predicting the TEC value, it is possible to predict the effects of ionospheric refraction and develop techniques to increase reliability in services that depend on GNSS. This study spans the four seasons from 2018 to 2023, utilizing measurements of ionospheric delays collected by the UTC(INXE). Daily, seasonal, and annual variations in Vertical TEC (VTEC) values are analyzed. A comparative assessment is made between the VTEC values obtained by the GPS P3 method and the Ionospheric Map method for each season until winter 2023. The Analysis of Variance demonstrated the compatibility and comparability of the two methods. Additionally, this investigation explores changes in the ionosphere behavior at the UTC(INXE) location during the geomagnetic storms caused by the solar explosions on April 21, 2023. The findings provide valuable insights for the ionosphere dynamics and can contribute to developing techniques to improve GNSS services’ reliability.
- 1 February 2021
- Published by Elsevier in Journal of Network and Computer Applications
- Vol. 175
Field surveillance of fuel dispensers using IoT-based metering and blockchains
- 1 February 2021
- Published by Elsevier in Journal of Network and Computer Applications
- Vol. 175
Field surveillance of fuel dispensers using IoT-based metering and blockchains
- 1 April 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-2
Brazilian Progress on Frequency Standards and Timescales: State of the Art of the Brazilian Scientific Time and Frequency Program
In this work we report the current status of the brazilian scientific program for time and frequency metrology. The joint efforts of our research groups, within the framework of a formal scientific collaboration, resulted in the development of an atomic fountain of Cs 133, a compact frequency standard with cold atoms and two new timescales contributing to TAI and UTC.
- 1 April 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-2
Brazilian Progress on Frequency Standards and Timescales: State of the Art of the Brazilian Scientific Time and Frequency Program
In this work we report the current status of the brazilian scientific program for time and frequency metrology. The joint efforts of our research groups, within the framework of a formal scientific collaboration, resulted in the development of an atomic fountain of Cs 133, a compact frequency standard with cold atoms and two new timescales contributing to TAI and UTC.
- 1 April 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 209-212
Implementation of Cybersecurity Procedures in Remote Calibration for PNT Services
This paper presents the implementation of cybersecurity procedures in remote calibration for time and frequency dissemination to be used in position, navigation and timing services. The remote calibration method uses a P3 algorithm that combines P1 and P2 codes from satellite link and turn it free of ionosphere refraction to compare distant timescales. The proposed algorithm is also implemented in the calculation of the reference time scale UTC (Coordinated Universal Time) on the key comparison CCTF-KOOl.UTC. Results of satellite comparison between UTC(INXE) and UTC(OP) has been used to prove the suitability and reliability of the method. This work demonstrated that the communication exchange between client and provider needs to be secure in three dimensions: confidentiality, integrity and authenticity and the process management of the results should take care of these cybersecurity pillars.
- 1 April 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 209-212
Implementation of Cybersecurity Procedures in Remote Calibration for PNT Services
This paper presents the implementation of cybersecurity procedures in remote calibration for time and frequency dissemination to be used in position, navigation and timing services. The remote calibration method uses a P3 algorithm that combines P1 and P2 codes from satellite link and turn it free of ionosphere refraction to compare distant timescales. The proposed algorithm is also implemented in the calculation of the reference time scale UTC (Coordinated Universal Time) on the key comparison CCTF-KOOl.UTC. Results of satellite comparison between UTC(INXE) and UTC(OP) has been used to prove the suitability and reliability of the method. This work demonstrated that the communication exchange between client and provider needs to be secure in three dimensions: confidentiality, integrity and authenticity and the process management of the results should take care of these cybersecurity pillars.
- 1 April 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 213-217
True Random Number Generators for Batch Control Sampling in Smart Factories
This paper presents the assembling of a simple photo quantum true random number generator that can be easily adapted to provide a web service for randomness beacon. The sampling stage for monitoring and controlling a line production in Industry 4.0 should be certifiable and easily inserted in the process control. This certification is required due to total quality control management and the easibility aspect is due to the evolving automation of machines and devices in the production process. The randomness of the batch control can be physically and intrinsically verifiable and certifiable by using the service that will be offered by using the device presented here.
- 1 April 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 213-217
True Random Number Generators for Batch Control Sampling in Smart Factories
This paper presents the assembling of a simple photo quantum true random number generator that can be easily adapted to provide a web service for randomness beacon. The sampling stage for monitoring and controlling a line production in Industry 4.0 should be certifiable and easily inserted in the process control. This certification is required due to total quality control management and the easibility aspect is due to the evolving automation of machines and devices in the production process. The randomness of the batch control can be physically and intrinsically verifiable and certifiable by using the service that will be offered by using the device presented here.
- Open Access
- 1 July 2016
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 733 (1) , 012021
Necessary and convenient number of indications in a measurement
The work addresses the problem of how to properly stipulate a suitable number of indications or repetitions to be used in a measurement. This appropriate and adequate number of indications is understood and is proposed as the minimal number that induces, when the resulting Type A uncertainty is included in the calculation, a relative change in the preexisting combined uncertainty lower than some parameter Q. In its turn, the parameter Q is anticipated by the metrologist based on an analysis of the experimentational context in which the measurement is being made.
- 1 July 2016
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 733 (1) , 012021
Open AccessNecessary and convenient number of indications in a measurement
The work addresses the problem of how to properly stipulate a suitable number of indications or repetitions to be used in a measurement. This appropriate and adequate number of indications is understood and is proposed as the minimal number that induces, when the resulting Type A uncertainty is included in the calculation, a relative change in the preexisting combined uncertainty lower than some parameter Q. In its turn, the parameter Q is anticipated by the metrologist based on an analysis of the experimentational context in which the measurement is being made.
- Open Access
- 1 July 2016
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 733 (1) , 012020
Historical overview of Ramsey spectroscopy and its relevance on Time and Frequency Metrology
A brief overview of the historical evolution of the method of successive oscillatory fields developed by Norman Ramsey, and some different implementations of the decurrent methodology are presented. We use time and frequency standards, from Cs atomic beams to optical standards, as examples. The scientific progress and the technological implementation achieved through a partnership between USP-SC and INMETRO are shown on the characterization of each time and frequency standard.
- 1 July 2016
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 733 (1) , 012020
Open AccessHistorical overview of Ramsey spectroscopy and its relevance on Time and Frequency Metrology
A brief overview of the historical evolution of the method of successive oscillatory fields developed by Norman Ramsey, and some different implementations of the decurrent methodology are presented. We use time and frequency standards, from Cs atomic beams to optical standards, as examples. The scientific progress and the technological implementation achieved through a partnership between USP-SC and INMETRO are shown on the characterization of each time and frequency standard.