Wen Yao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Wen Yao has a total of 34 co-authors. Here are the top co-authors by number of shared publications:
- Yijun Zhang
Department of Atmospheric and Oceanic Sciences & Institute of Atmospheric Sciences Fudan University Shanghai China
8 shared publications - Dong Zheng
State Key Laboratory of Severe Weather Meteorological Science and Technology & CMA Key Laboratory of Lightning Chinese Academy of Meteorological Sciences Beijing China
7 shared publications - Weitao Lyu
State Key Laboratory of Severe Weather Meteorological Science and Technology/CMA Key Laboratory of Lightning Chinese Academy of Meteorological Sciences Beijing China
4 shared publications - Liangtao Xu
State Key Laboratory of Severe Weather Meteorological Science and Technology & CMA Key Laboratory of Lightning Chinese Academy of Meteorological Sciences Beijing China
3 shared publications - Wenjuan Zhang
State Key Laboratory of Severe Weather, Chinese Academy of Meteorological Sciences, Beijing 100081, China
3 shared publications - Qingyong Li
Beijing Jiaotong University
2 shared publications
Latest Publications
- Open Access
- 20 April 2026
- Published by Association for Computing Machinery (ACM)
- p. 2494-2505
ASTAFN: Bridging the Gap Between Weather Foundation Models and Accurate Station-Level Forecasting
- 20 April 2026
- Published by Association for Computing Machinery (ACM)
- p. 2494-2505
Open AccessASTAFN: Bridging the Gap Between Weather Foundation Models and Accurate Station-Level Forecasting
- Open Access
- 14 December 2024
- Published by MDPI AG in Remote Sensing
- Vol. 16 (24) , 4673
Thunderstorms with Extreme Lightning Activity in China: Climatology, Synoptic Patterns, and Convective Parameters
Intense convection is often accompanied by high-frequency lightning and is highly prone to producing heavy rainfall, strong winds, hail, and tornadoes, frequently resulting in significant damage and loss of life. It is necessary to understand the mechanisms and meteorological conditions of intense convection. This study utilizes the Thunderstorm Feature Dataset from 2010–2018 to analyze the characteristics of thunderstorms with extreme lightning activity (TELAs), defined as thunderstorms whose lightning frequency ranks in the top 1%. Four regions with relatively high thunderstorm activity were selected for analysis: Northeast China (NEC), North China (NC), South China (SC), and the Tibetan Plateau (TP). In NEC, TELAs primarily occur just west of upper-level westerly troughs (UWT), including cold vortices. In NC, TELAs are mainly associated with UWT and subtropical highs (STH). In SC, TELAs are related to frontal systems, easterly waves, tropical cyclones, and STH. In TP, TELAs are generated by TP vortices. Before the TELA process, vertically integrated moisture divergence (VIMD) and convective available potential energy (CAPE) show the most notable anomalies. Except for the TP, TELAs are typically located between centers of anomalies with positive and negative geopotential height (500 hPa) and near centers of anomalies with positive CAPE and negative VIMD, accompanied by notable increases in surface temperature and wind speed. These findings offer a valuable reference for the early warning and forecasting of intense convection.
- 14 December 2024
- Published by MDPI AG in Remote Sensing
- Vol. 16 (24) , 4673
Open AccessThunderstorms with Extreme Lightning Activity in China: Climatology, Synoptic Patterns, and Convective Parameters
Intense convection is often accompanied by high-frequency lightning and is highly prone to producing heavy rainfall, strong winds, hail, and tornadoes, frequently resulting in significant damage and loss of life. It is necessary to understand the mechanisms and meteorological conditions of intense convection. This study utilizes the Thunderstorm Feature Dataset from 2010–2018 to analyze the characteristics of thunderstorms with extreme lightning activity (TELAs), defined as thunderstorms whose lightning frequency ranks in the top 1%. Four regions with relatively high thunderstorm activity were selected for analysis: Northeast China (NEC), North China (NC), South China (SC), and the Tibetan Plateau (TP). In NEC, TELAs primarily occur just west of upper-level westerly troughs (UWT), including cold vortices. In NC, TELAs are mainly associated with UWT and subtropical highs (STH). In SC, TELAs are related to frontal systems, easterly waves, tropical cyclones, and STH. In TP, TELAs are generated by TP vortices. Before the TELA process, vertically integrated moisture divergence (VIMD) and convective available potential energy (CAPE) show the most notable anomalies. Except for the TP, TELAs are typically located between centers of anomalies with positive and negative geopotential height (500 hPa) and near centers of anomalies with positive CAPE and negative VIMD, accompanied by notable increases in surface temperature and wind speed. These findings offer a valuable reference for the early warning and forecasting of intense convection.
- Open Access
- 25 January 2024
- Published by MDPI AG in Remote Sensing
- Vol. 16 (3) , 468
Spatiotemporal Distributions of the Thunderstorm and Lightning Structures over the Qinghai–Tibet Plateau
Utilizing data from the Tropical Rainfall Measuring Mission (TRMM) satellite’s precipitation radar (PR) and lightning imaging sensor (LIS), this study explores the spatiotemporal distributions of thunderstorm and lightning structures over the Qinghai–Tibet Plateau (QTP), an aspect that has not been explored previously. The structural aspects are crucial when considering the impact of thunderstorm and lightning activity in the atmospheric processes. Thunderstorms over the QTP show clear spatial variations in both vertical height and horizontal extension. In the southern region, the average heights of 20 dBZ and 30 dBZ echo tops typically exceed 11.2 and 9.3 km, respectively. Meanwhile, in the eastern part, the average coverage areas for reflectivity greater than 20 dBZ and 30 dBZ consistently surpass 1000 and 180 km2, respectively. The spatial distribution of thunderstorm vertical development height relative to the surface aligns more closely with the horizontal extension, indicating stronger convection in the eastern QTP. The thunderstorm flash rate shows an eastward and northward prevalence, while the thunderstorm flash density peaks in the western and northeastern QTP, with a minimum in the southeast. Furthermore, in the eastern QTP, lightning duration, spatial expansion, and radiance are more pronounced, with the average values typically exceeding 0.22 s, 14.5 km, and 0.50 J m−2 sr−1 μm−1, respectively. Monthly variations reveal heightened values during the summer season for thunderstorm vertical extension, areas with reflectivity greater than 30 dBZ, and lightning frequency. Diurnal variations highlight an afternoon increase in thunderstorm vertical and horizontal extension, lightning frequency, duration, and spatial scale. From a statistical perspective, under weak convective conditions, lightning length exhibits a positive correlation with thunderstorm convection intensity, contrasting with the opposite relationship suggested by previous studies. This article further analyzes and discusses the correlations between various thunderstorm and lightning structural parameters, enhancing our understanding of the distinctive features of thunderstorm and lightning activities in the QTP.
- 25 January 2024
- Published by MDPI AG in Remote Sensing
- Vol. 16 (3) , 468
Open AccessSpatiotemporal Distributions of the Thunderstorm and Lightning Structures over the Qinghai–Tibet Plateau
Utilizing data from the Tropical Rainfall Measuring Mission (TRMM) satellite’s precipitation radar (PR) and lightning imaging sensor (LIS), this study explores the spatiotemporal distributions of thunderstorm and lightning structures over the Qinghai–Tibet Plateau (QTP), an aspect that has not been explored previously. The structural aspects are crucial when considering the impact of thunderstorm and lightning activity in the atmospheric processes. Thunderstorms over the QTP show clear spatial variations in both vertical height and horizontal extension. In the southern region, the average heights of 20 dBZ and 30 dBZ echo tops typically exceed 11.2 and 9.3 km, respectively. Meanwhile, in the eastern part, the average coverage areas for reflectivity greater than 20 dBZ and 30 dBZ consistently surpass 1000 and 180 km2, respectively. The spatial distribution of thunderstorm vertical development height relative to the surface aligns more closely with the horizontal extension, indicating stronger convection in the eastern QTP. The thunderstorm flash rate shows an eastward and northward prevalence, while the thunderstorm flash density peaks in the western and northeastern QTP, with a minimum in the southeast. Furthermore, in the eastern QTP, lightning duration, spatial expansion, and radiance are more pronounced, with the average values typically exceeding 0.22 s, 14.5 km, and 0.50 J m−2 sr−1 μm−1, respectively. Monthly variations reveal heightened values during the summer season for thunderstorm vertical extension, areas with reflectivity greater than 30 dBZ, and lightning frequency. Diurnal variations highlight an afternoon increase in thunderstorm vertical and horizontal extension, lightning frequency, duration, and spatial scale. From a statistical perspective, under weak convective conditions, lightning length exhibits a positive correlation with thunderstorm convection intensity, contrasting with the opposite relationship suggested by previous studies. This article further analyzes and discusses the correlations between various thunderstorm and lightning structural parameters, enhancing our understanding of the distinctive features of thunderstorm and lightning activities in the QTP.
- Open Access
- 15 December 2023
- Published by MDPI AG in Remote Sensing
- Vol. 15 (24) , 5733
Significant Location Accuracy Changes Resulting from Lightning Detection Networks Deployed on Inclined Terrains
This study investigates the location accuracy distribution of the lightning detection networks (LDNs) deployed on inclined terrains, an aspect frequently encountered in complex terrains but hitherto disregarded in previous studies. By designing eight substation LDNs deployed on slope-type (ST), mountain-type (MT) and basin-type (BT) terrains, respectively, we employed Monte Carlo simulations to analyze their spatial location accuracy distribution based on time-of-arrival technology. Significant differences among the LDNs on inclined terrains and between them and the LDN on plain-type (PT) terrain were revealed. Compared to the PT LDN, LDNs on inclined terrains exhibited a reduction in high-precision location regions and a shift in the distribution pattern of location accuracy. The ST LDN showed marked deviations in the high-precision vertical location toward the lower slope side with increases in the elevation angle and consistently smaller high-precision vertical location areas compared to MT and BT LDNs. The variations in elevation angles of MT and BT LDNs had a substantial impact on the spatial distribution patterns of both horizontal and vertical location accuracy, with BT LDNs featuring larger vertical high-precision areas than MT LDNs. Our conclusions were further corroborated through an analysis of an actual LDN, which combined characteristics from both ST and MT terrain patterns.
- 15 December 2023
- Published by MDPI AG in Remote Sensing
- Vol. 15 (24) , 5733
Open AccessSignificant Location Accuracy Changes Resulting from Lightning Detection Networks Deployed on Inclined Terrains
This study investigates the location accuracy distribution of the lightning detection networks (LDNs) deployed on inclined terrains, an aspect frequently encountered in complex terrains but hitherto disregarded in previous studies. By designing eight substation LDNs deployed on slope-type (ST), mountain-type (MT) and basin-type (BT) terrains, respectively, we employed Monte Carlo simulations to analyze their spatial location accuracy distribution based on time-of-arrival technology. Significant differences among the LDNs on inclined terrains and between them and the LDN on plain-type (PT) terrain were revealed. Compared to the PT LDN, LDNs on inclined terrains exhibited a reduction in high-precision location regions and a shift in the distribution pattern of location accuracy. The ST LDN showed marked deviations in the high-precision vertical location toward the lower slope side with increases in the elevation angle and consistently smaller high-precision vertical location areas compared to MT and BT LDNs. The variations in elevation angles of MT and BT LDNs had a substantial impact on the spatial distribution patterns of both horizontal and vertical location accuracy, with BT LDNs featuring larger vertical high-precision areas than MT LDNs. Our conclusions were further corroborated through an analysis of an actual LDN, which combined characteristics from both ST and MT terrain patterns.
- Open Access
- 26 August 2022
- Published by MDPI AG in Remote Sensing
- Vol. 14 (17) , 4214
Spatiotemporal Correlation between Artificially Triggered and Adjacent Natural Lightning Flashes
A triggered lightning flash (TLF) provides a unique perspective on the relationship between spatiotemporal proximity flashes, owing to its determined location and time, convenient direction measurement, and explicit association with the charge region. In this study, 3-D lightning location, current measurement, and atmospheric average electric field (AAEF) data were used to investigate the spatiotemporal relationship of TLFs (68 samples in South China) with adjacent natural lightning flashes (NLFs). The TLF-related negative charge regions had an average core height of 5.2 km and ambient temperature of approximately −1.7 °C. The effective negative charge region (the charge density that was high enough for the occurrence of lightning discharge) can be approximately equivalent to a circle with an average diameter of 10.3 km. For approximately 93% of (all) the TLFs, no NLF channel (initiation) was located within 5 km of the flash-triggered position, within 5 s before and after their occurrence. In situations where spatiotemporally adjacent NLFs and TLFs occurred, they were either associated with different charge layers or the same charge layer but different charge positions. Most NLFs that caused significantly sharp AAEF changes just before or after the TLFs were not associated with the TLF-related negative charge. Therefore, the recovery of the AAEF, which has usually been referenced as the timing choice of the triggering operation, was not directly associated with the TLF-related charge region. The average interval between the TLFs and NLFs that occurred within 10 min before and after the TLFs and neutralized the TLF-related negative charge was approximately 145 s.
- 26 August 2022
- Published by MDPI AG in Remote Sensing
- Vol. 14 (17) , 4214
Open AccessSpatiotemporal Correlation between Artificially Triggered and Adjacent Natural Lightning Flashes
A triggered lightning flash (TLF) provides a unique perspective on the relationship between spatiotemporal proximity flashes, owing to its determined location and time, convenient direction measurement, and explicit association with the charge region. In this study, 3-D lightning location, current measurement, and atmospheric average electric field (AAEF) data were used to investigate the spatiotemporal relationship of TLFs (68 samples in South China) with adjacent natural lightning flashes (NLFs). The TLF-related negative charge regions had an average core height of 5.2 km and ambient temperature of approximately −1.7 °C. The effective negative charge region (the charge density that was high enough for the occurrence of lightning discharge) can be approximately equivalent to a circle with an average diameter of 10.3 km. For approximately 93% of (all) the TLFs, no NLF channel (initiation) was located within 5 km of the flash-triggered position, within 5 s before and after their occurrence. In situations where spatiotemporally adjacent NLFs and TLFs occurred, they were either associated with different charge layers or the same charge layer but different charge positions. Most NLFs that caused significantly sharp AAEF changes just before or after the TLFs were not associated with the TLF-related negative charge. Therefore, the recovery of the AAEF, which has usually been referenced as the timing choice of the triggering operation, was not directly associated with the TLF-related charge region. The average interval between the TLFs and NLFs that occurred within 10 min before and after the TLFs and neutralized the TLF-related negative charge was approximately 145 s.
- Open Access
- 15 June 2022
- Published by MDPI AG in Remote Sensing
- Vol. 14 (12) , 2855
Thunderstorm Activity over the Qinghai–Tibet Plateau Indicated by the Combined Data of the FY-2E Geostationary Satellite and WWLLN
Thunderstorm activity over the Qinghai–Tibet Plateau (QTP) has important climatic effects and disaster impacts. Using the thunderstorm feature dataset (TFD) established based on the black body temperature (TBB) and cloud classification (CLC) products of the Fengyun-2E (FY-2E) geostationary satellite, as well as the lightning data of the World Wide Lightning Location Network (WWLLN), the temporal and spatial distributions and some cloud properties of the thunderstorms over the QTP were analyzed. Approximately 93.9% and 82.7% of thunderstorms over the QTP occur from May to September and from 12 to 21 o’clock local time, and the corresponding peaks are in August and at 14:00, respectively. There are three centers featuring frequent thunderstorms in the southeast, south-central, and southwest regions of the QTP. The average thunderstorm cloud area (the region with TBB ≤ −32 °C) is 1.8 × 104 km2. Approximately 32.9% of thunderstorms have strong convective cells (SCCs) composed of areas with TBB ≤ −52 °C. The average number and area ratio of SCCs are 3.6 and 25.4%, respectively, and their spatial distribution is given. The average cloud area and the number and area ratio of SCCs of extreme-lightning thunderstorms (thunderstorms with the top 10% of lightning numbers) are approximately 30.0, 3.9, and 1.5 times those of normal thunderstorms. The spatial distribution of the thunderstorm activity is quite different from that of lightning activity given by the Lightning Imaging Sensor (LIS) and Optical Transient Detector (OTD) over the northeastern and southwestern QTP, which may mean that the convection intensity, cloud structure, and charge structure of the thunderstorms over the QTP are different between different regions and seasons.
- 15 June 2022
- Published by MDPI AG in Remote Sensing
- Vol. 14 (12) , 2855
Open AccessThunderstorm Activity over the Qinghai–Tibet Plateau Indicated by the Combined Data of the FY-2E Geostationary Satellite and WWLLN
Thunderstorm activity over the Qinghai–Tibet Plateau (QTP) has important climatic effects and disaster impacts. Using the thunderstorm feature dataset (TFD) established based on the black body temperature (TBB) and cloud classification (CLC) products of the Fengyun-2E (FY-2E) geostationary satellite, as well as the lightning data of the World Wide Lightning Location Network (WWLLN), the temporal and spatial distributions and some cloud properties of the thunderstorms over the QTP were analyzed. Approximately 93.9% and 82.7% of thunderstorms over the QTP occur from May to September and from 12 to 21 o’clock local time, and the corresponding peaks are in August and at 14:00, respectively. There are three centers featuring frequent thunderstorms in the southeast, south-central, and southwest regions of the QTP. The average thunderstorm cloud area (the region with TBB ≤ −32 °C) is 1.8 × 104 km2. Approximately 32.9% of thunderstorms have strong convective cells (SCCs) composed of areas with TBB ≤ −52 °C. The average number and area ratio of SCCs are 3.6 and 25.4%, respectively, and their spatial distribution is given. The average cloud area and the number and area ratio of SCCs of extreme-lightning thunderstorms (thunderstorms with the top 10% of lightning numbers) are approximately 30.0, 3.9, and 1.5 times those of normal thunderstorms. The spatial distribution of the thunderstorm activity is quite different from that of lightning activity given by the Lightning Imaging Sensor (LIS) and Optical Transient Detector (OTD) over the northeastern and southwestern QTP, which may mean that the convection intensity, cloud structure, and charge structure of the thunderstorms over the QTP are different between different regions and seasons.
- Open Access
- 28 February 2022
- Published by MDPI AG in Remote Sensing
- Vol. 14 (5) , 1193
Characteristics of Regions with High-Density Initiation of Flashes in Mesoscale Convective Systems
To investigate the characteristics of regions exhibiting multiple lightning initiations within a finite volume and a short time, the lightning location data obtained from the convective regions of 14 mesoscale convective systems were analyzed in combination with data from radar. In total, 415 out of 5996 radar grids (1 km × 1 km × 0.5 km) were found to initiate more than one flash within 6 min. Only 49 grids showed an initiation density of more than two flashes within 6 min. The grids with high flash initiation densities were found to have a similar distribution to those with one lightning initiation within 6 min, in terms of altitude and reflectivity relative to altitude. They also showed similar trends in their frequency evolution. The grids with higher initiation densities seemed to be more concentrated in the altitude range of 9–13 km. However, only one was found to form at a lower altitude near the melting level when lightning initiation clearly declined. Moreover, the spatial relationship of this lower higher-initiation density grid to the reflectivity core was different to that in the main altitude range. In this paper, the possible dynamic and electrical mechanisms of the formation of this lower higher-initiation density grid are discussed.
- 28 February 2022
- Published by MDPI AG in Remote Sensing
- Vol. 14 (5) , 1193
Open AccessCharacteristics of Regions with High-Density Initiation of Flashes in Mesoscale Convective Systems
To investigate the characteristics of regions exhibiting multiple lightning initiations within a finite volume and a short time, the lightning location data obtained from the convective regions of 14 mesoscale convective systems were analyzed in combination with data from radar. In total, 415 out of 5996 radar grids (1 km × 1 km × 0.5 km) were found to initiate more than one flash within 6 min. Only 49 grids showed an initiation density of more than two flashes within 6 min. The grids with high flash initiation densities were found to have a similar distribution to those with one lightning initiation within 6 min, in terms of altitude and reflectivity relative to altitude. They also showed similar trends in their frequency evolution. The grids with higher initiation densities seemed to be more concentrated in the altitude range of 9–13 km. However, only one was found to form at a lower altitude near the melting level when lightning initiation clearly declined. Moreover, the spatial relationship of this lower higher-initiation density grid to the reflectivity core was different to that in the main altitude range. In this paper, the possible dynamic and electrical mechanisms of the formation of this lower higher-initiation density grid are discussed.
- Open Access
- 15 February 2022
- Published by Wiley in Advances in Meteorology
- Vol. 2022, 1-13
Evaluation of Lightning Prediction by an Electrification and Discharge Model in Long-Term Forecasting Experiments
Over nearly three rainy seasons of lightning activity in North China, numerical prediction experiments were carried out using the Weather Research and Forecasting model coupled with electrification and discharge schemes (WRF-Electric). The numerical forecast results were evaluated using the neighborhood-based equitable threat score (ETS) and fraction skill score (FSS) verification methods based on nationwide observational lightning data. An algorithm was used to generate the coverage of the total flash (intracloud and cloud-to-ground flashes) by fitting the cloud-to-ground flash data. The numerical results showed that the region of lightning activity could be well predicted by the mesoscale WRF-Electric model, particularly during a 6–12-hour forecasting period. The average ETS score of the 6–12-hour forecasting period was 0.34 for a 20 km neighborhood radius. The predictive skill of the model varied not only monthly but also diurnally. The model showed better forecasting skills during the main rainy season (June–July–August) and at 14 : 00–20 : 00 local time. The predictability of the model was enhanced with increasing thunderstorm scale. On the other hand, the coverage of predicted lightning activity was relatively concentrated, and the lightning flash density was higher than the observations. The main discrepancies in the model prediction were related to the design of the discharge parameterization. Thus, in discharge parameterization, the initial threshold for lightning should be modified according to the model resolution, while the magnitude of the neutralization charge in a single discharge should be referenced to the observational results.
- 15 February 2022
- Published by Wiley in Advances in Meteorology
- Vol. 2022, 1-13
Open AccessEvaluation of Lightning Prediction by an Electrification and Discharge Model in Long-Term Forecasting Experiments
Over nearly three rainy seasons of lightning activity in North China, numerical prediction experiments were carried out using the Weather Research and Forecasting model coupled with electrification and discharge schemes (WRF-Electric). The numerical forecast results were evaluated using the neighborhood-based equitable threat score (ETS) and fraction skill score (FSS) verification methods based on nationwide observational lightning data. An algorithm was used to generate the coverage of the total flash (intracloud and cloud-to-ground flashes) by fitting the cloud-to-ground flash data. The numerical results showed that the region of lightning activity could be well predicted by the mesoscale WRF-Electric model, particularly during a 6–12-hour forecasting period. The average ETS score of the 6–12-hour forecasting period was 0.34 for a 20 km neighborhood radius. The predictive skill of the model varied not only monthly but also diurnally. The model showed better forecasting skills during the main rainy season (June–July–August) and at 14 : 00–20 : 00 local time. The predictability of the model was enhanced with increasing thunderstorm scale. On the other hand, the coverage of predicted lightning activity was relatively concentrated, and the lightning flash density was higher than the observations. The main discrepancies in the model prediction were related to the design of the discharge parameterization. Thus, in discharge parameterization, the initial threshold for lightning should be modified according to the model resolution, while the magnitude of the neutralization charge in a single discharge should be referenced to the observational results.
- 20 January 2022
- Published by Springer Nature in Applied Intelligence
- Vol. 52 (10) , 11147-11159
LightNet+: A dual-source lightning forecasting network with bi-direction spatiotemporal transformation
- 20 January 2022
- Published by Springer Nature in Applied Intelligence
- Vol. 52 (10) , 11147-11159
LightNet+: A dual-source lightning forecasting network with bi-direction spatiotemporal transformation
- 16 June 2017
- Published by American Geophysical Union (AGU) in Journal of Geophysical Research: Atmospheres
- Vol. 122 (11) , 5943-5954
Influence of the Canton Tower on the cloud‐to‐ground lightning in its vicinity
This paper analyzed the influence of the Canton Tower on cloud‐to‐ground lightning in its vicinity based on the data obtained by Lightning Location System (LLS) of the Guangdong Power Grid Corporation from 1999 to 2015. The LLS data obtained before (1999–2005) and after (2010–2015) the erection of the Canton Tower were compared. The flash/stroke density showed a significant increase in the immediate vicinity around the Canton Tower within a radius of 1 km and a clear decrease in the annular vicinity with a radius from 1 km to 4 km. The arithmetic mean and median LLS‐inferred peak current of strokes that occurred in 1 km radius area around the Canton Tower exhibited a significant increase, while that of the strokes that occurred beyond 1 km did not show a clear change. The percentage of negative flashes (ratio of negative flashes to total flashes) showed a slight increase in the immediate vicinity around the Canton Tower, which could be caused by the upward lightning (often negative) initiated from the tower. Due to the existence of the Canton Tower, the lightning multiplicity presented a decreasing trend to some extent within 4 km radius around the tower compared with the arithmetic mean value within 10 km radius. It is speculated that the Canton Tower induced lots of upward flashes and attracted some downward flashes around it within several kilometers radius to itself.
- 16 June 2017
- Published by American Geophysical Union (AGU) in Journal of Geophysical Research: Atmospheres
- Vol. 122 (11) , 5943-5954
Influence of the Canton Tower on the cloud‐to‐ground lightning in its vicinity
This paper analyzed the influence of the Canton Tower on cloud‐to‐ground lightning in its vicinity based on the data obtained by Lightning Location System (LLS) of the Guangdong Power Grid Corporation from 1999 to 2015. The LLS data obtained before (1999–2005) and after (2010–2015) the erection of the Canton Tower were compared. The flash/stroke density showed a significant increase in the immediate vicinity around the Canton Tower within a radius of 1 km and a clear decrease in the annular vicinity with a radius from 1 km to 4 km. The arithmetic mean and median LLS‐inferred peak current of strokes that occurred in 1 km radius area around the Canton Tower exhibited a significant increase, while that of the strokes that occurred beyond 1 km did not show a clear change. The percentage of negative flashes (ratio of negative flashes to total flashes) showed a slight increase in the immediate vicinity around the Canton Tower, which could be caused by the upward lightning (often negative) initiated from the tower. Due to the existence of the Canton Tower, the lightning multiplicity presented a decreasing trend to some extent within 4 km radius around the tower compared with the arithmetic mean value within 10 km radius. It is speculated that the Canton Tower induced lots of upward flashes and attracted some downward flashes around it within several kilometers radius to itself.