KSKhaled Salman

Khaled Salman

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Khaled Salman has a total of 51 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • The Impact of Digital Transformation on Family Security

    by Atheer Binsalman, Khalid Salman, Maha Alqohmani

  • Open Access

    Measurement of cumulative radiation exposure to children and adolescents in contact with outpatients treated with low dose radioactive iodine (131I)

    by Khaled Salman, Shereen Wagieh, Aquib Bakhsh, Tarek Al-Monshy, Omnia Talaat, Musaed Al-Malki, Manal Al-Ezzi, Ashraf Fouda, Gihad Hamid

    Background: Radiation exposure from patients treated with radioactive iodine (131I) represents a radiation hazard to children and adolescents, representing the most vulnerable group of household contacts. Our aim was to calculate the cumulative radiation exposure (CRE) figures to children and adolescents sharing the same home with outpatients treated with low-dose 131I. The secondary aim was to study the demographic and educational factors that may significantly affect radiation exposure to them. Results: The whole number of household contacts less than 18 years was 99, out of them 49 ≤ 12 years. CRE level to children and adolescents ranged from 79 to 934 uSv. The mean, median, and 75th percentile figures were 284 ± 178 uSv, 215 uSv, and 334 uSv, respectively. The compliance of this group of contacts to radiation exposure constraint (1 mSv) was 100%. All CRE values were below this figure with 75% of them below half of this constraint. Thirteen adolescents from 12 to 18 years and 17 mothers of 23 household contacts ≤ 12 years got radiation safety instructions (RSI) directly from a radiation safety officer (RSO). This group had a significantly lower mean CRE value (184 ± 93 uSv) compared to those who got RSI from the patient or from other family members (298 ± 185 uSv) with a significant p value. Conclusion: The compliance of adolescents and children to the 1-mSv radiation exposure constraint is 100%. It is advised for adolescents and mothers of children in contact with 131I-treated patients to get direct RSI from the RSO, which is the only factor associated with significantly lower radiation exposure figures.


  • Open Access

    Retrospective study of Tc-99m thyroid scan in patients with graves' disease: Is there significant difference in lobar activity?

    by Shereen Wagieh, Khaled Salman, Aquib Bakhsh, Omnia Talaat, Soha Al Morsy, Manal Al-Ezzi, Gihad Hamid, Nasser Al-Juhani

    D incidence of higher activity of either thyroid lobe in patients with GD through analysis of quantitative data of Tc-99m thyroid scan and possible relation of different thyroid lobar activity to gender, age, and total thyroid uptake (TTU) level. Materials and Methods: Retrospective analysis of quantitative data of Tc-99m thyroid scan in patients with GD was done. Total and lobar thyroid uptake levels were analyzed and correlated with age, gender, and TTU. Results: GD was reported in 222 patients, representing 76.6% of those with hyperthyroidism, women represent 70.3% of patients. The right thyroid lobe uptake (RLU) figures were significantly higher compared to the left in the whole group as well as in women and in young patients (30% had higher RLU figures. Conclusion: There is significant preferential thyroid lobar affection in favor of the right thyroid lobe in patients with GD, with significantly higher RLU figures and significantly more incidence of patients with higher right lobar activity. This significance is maintained in women and in young patients and lost in men and old patients. The incidence of higher right thyroid lobe activity also increases in association with increase in TTU. Our results emphasize the value of Tc99m thyroid scan in patients with GD, especially when surgery is the treatment of choice, helping to tailor suitable surgical procedure for each individual patient....


  • Open Access

    Measurement of radiation exposure to household contacts of patients with Graves’ disease treated with low dose radioactive iodine (131I) on outpatient basis

    by K.H. Salman, Sh. Wagih, T. Munshi, M. Almalki, S. Zatari, K.H. Zahid, S. El-Morsy, D. Abd-Al Moety, M. Al-Ezzi


  • Novel approach to coronary artery perforation repair

    by Joseph Ingrassia, Young Jin Youn, Juyong Lee, Michael Azrin, Salman Khalid

    Coronary artery perforation (CAP) during percutaneous coronary intervention is a rare but serious complication. Treatment options of CAP include prolonged balloon inflation, covered stent, and coil embolization. Although most cases of CAP can be treated with prolonged balloon inflation, some cases, especially Ellis grade III CAP require covered stents or coiling. Covered stents may require a large bore guide catheter and have a high rate of restenosis, which can be a limiting factor in patients with severe peripheral arterial disease. Coil embolization is generally used in distal CAP because coiling in the proximal vessels results in a large territory of infarction. We present a case of an Ellis grade III CAP during rotational atherectomy successfully treated with a novel coiling technique whereby the thrombogenic coil extends through the perforation outside of the vessel, and the intraarterial portion of the coil is excluded from the lumen by drug‐eluting stent placement over the proximal portion of the coil.


  • Open Access

    Measurement of External Radiation Exposure to Household Contacts of Outpatients Treated with Radioactive Iodine (131I).

    by Kh Salman, Sh Wagih, T Munshi, M Almalki, S. Zatari, S. El-Morsy, D. Abd-Al Moety, Kh. Zahid

    Background: Outpatients treated with low dose radioactive iodine (131I) represent radiation hazard to caregivers and family members. Detailed radiation safety instructions (RSI) should be given by qualified professionals in a clear and proper way to avoid radiation overexposure. We aimed at measurement of cumulative radiation exposure (CRE) to household contacts of outpatients treated with low dose 131I (up to 1110MBq) together with looking for factors that can significantly affect CRE figures.Methods: Detailed RSI were properly explained to 61 patients and to one or more household contacts (87 out of 296) by radiation safety officer (RSO). Thermo-luminescent dosimeters (TLDs) were dispensed to all contacts after ensuring understanding how and when to be appliedand after confirming that RSI can be conveyed properly to rest of household contacts. TLD’s were collected fifth day after dispensing for measurement of CRE figures. The latter were correlated with different patients and contacts factors. Results: CRE figures were well below radiation exposure constraint of caregivers and family members living in the same house with the patient, ranging from 0.071 to 1.026 mSv. Single adult contact had CRE more than 1 mSv and the remaining 295 contacts had CRE below this limit. No single demographic or educational factor had statistically significant correlation with CRE. Lower CRE figures were found for contacts of thyroid cancer patients and contacts who received direct RSI from RSO. Conclusion: All CRE figures of household contacts of outpatients treatedwith low dose 131I therapy were well below radiation exposure constraint, denoting proper compliance of outpatients treated with 131I in King Abdalla Medical City (KAMC) and their household contacts to given RSI.Household contacts of thyroid cancer patients and those who received direct RSI from RSO had relatively lower CRE figures, raising the concept of giving RSI to all household contacts by qualified professionals.

  • Open Access

    Defining Coronary Artery Perforation with Ultrasound Contrast Agent

    by Young Jin Youn, Salman Khalid, Michael Azrin, Juyong Lee

    Youn YJ, et al. Korean Circ J. 2016 Sep;48:e120. https://doi.org/10.4070/kcj.2018.0179


  • Comparable ablation outcome between second and third ablation doses of 30 mCi radioactive iodine (131I) in patients with papillary thyroid cancer

    by Khaled Salman, Safwan Zatary, Shereen Wagieh, Kareem Maha Abd-El, Yasser Mohammad, Razek Sherif Abd-El, Manal Al-Ezzi

    Introduction: Complete ablation of residual thyroid tissue in patients with papillary thyroid cancer decreases locoregional recurrence, distant metastases and cancer death. No single group achieved 100% complete ablation post first ablation dose with variable successful complete ablation rate. In patients who failed to achieve complete ablation a reablation dose is recommended to have complete ablation outcome. Post second ablation dose some patients still have small residual thyroid tissue in the neck, that warrants small third ablation dose of 131I to achieve complete ablation. Aim: The aim of the current study is to compare ablation outcome post 30 mCi ablation dose of 131I used as a second and as a third ablation dose. Patients and methods: Retrospective analysis of data of 372 patients with papillary thyroid cancer confined to the thyroid gland referred post total thyroidectomy for 131I ablation was performed. All received first ablation dose of 100 mCi of 131I. Presence of residual thyroid tissue in follow-up 131I whole body scan (WBS) with elevated unsuppressed serum thryoglobulin (Tg) level indicate incomplete ablation outcome. Those patients received 30 mCi of 131I reablation on outpatient basis. Patients post second ablation dose with small residual thyroid tissue in the neck seen in follow-up 131I WBS 6–9 months post second ablation dose with elevated serum Tg level received a third ablation dose of 30 mCi. Follow-up WBS and Tg level were performed 6–9 months post third dose to assess ablation outcome. Results: Complete ablation rate post first dose was reported in 249 patients (66.9%). Out of the remaining 123 patients complete ablation was achieved post 30 mCi second ablation dose in 89 patients (72.4%) with an overall complete ablation post two doses achieved in 338 patients (90.9%). A third ablation dose of 30 mCi was given to the remaining 34 patients. Complete ablation was reported in 26 patients (76.5%), with statistically insignificant difference (P>0.05) between complete ablation outcome using 30 mCi as a second or as a third ablation dose. Successful complete ablation post three doses of 131I (total dose of 160 mCi) was achieved in 364 patients (97.8%). Conclusion: Complete ablation outcome rate between second and third ablation doses of 30 mCi of 131I are comparable with no statistically significant difference.