JMJ. Victor Marcos

J. Victor Marcos

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


J. Victor Marcos has a total of 31 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Regularity analysis of nocturnal oximetry recordings to assist in the diagnosis of sleep apnoea syndrome

    by J. Víctor Marcos, Roberto Hornero, Ian T. Nabney, Daniel Álvarez, Gonzalo C. Gutiérrez-Tobal, Félix del Campo

    The relationship between sleep apnoea-hypopnoea syndrome (SAHS) severity and the regularity of nocturnal oxygen saturation (SaO2) recordings was analysed. Three different methods were proposed to quantify regularity: approximate entropy (AEn), sample entropy (SEn) and kernel entropy (KEn). A total of 240 subjects suspected of suffering from SAHS took part in the study. They were randomly divided into a training set (96 subjects) and a test set (144 subjects) for the adjustment and assessment of the proposed methods, respectively. According to the measurements provided by AEn, SEn and KEn, higher irregularity of oximetry signals is associated with SAHS-positive patients. Receiver operating characteristic (ROC) and Pearson correlation analyses showed that KEn was the most reliable predictor of SAHS. It provided an area under the ROC curve of 0.91 in two-class classification of subjects as SAHS-negative or SAHS-positive. Moreover, KEn measurements from oximetry data exhibited a linear dependence on the apnoea-hypopnoea index, as shown by a correlation coefficient of 0.87. Therefore, these measurements could be used for the development of simplified diagnostic techniques in order to reduce the demand for polysomnographies. Furthermore, KEn represents a convincing alternative to AEn and SEn for the diagnostic analysis of noisy biomedical signals.


  • Quantitative Assessment of Emphysema Severity in Histological Lung Analysis

    by J. Víctor Marcos, Arrate Muñoz-Barrutia, Carlos Ortiz-De-Solórzano, Gabriel Cristóbal

    Emphysema is a characteristic component of chronic obstructive pulmonary disease (COPD), which has been pointed out as one of the main causes of mortality for the next years. Animal models of emphysema are employed to study the evolution of this disease as well as the effect of treatments. In this context, measures such as the mean linear intercept \(\left( L_{\rm m}\right) \) and the equivalent diameter \((d) \) have been proposed to quantify the airspace enlargement associated with emphysematous lesions in histological sections. The parameter \(D_{2}\) , which relates the second and the third moments of the variable \(d\) , has recently shown to be a robust descriptor of airspace enlargement. However, the value of \(D_{2}\) does not provide a direct evaluation of emphysema severity. In our research, we suggest a Bayesian approach to map \(D_{2}\) onto a novel emphysema severity index (SI) reflecting the probability for a lung area to be emphysematous. Additionally, an image segmentation procedure was developed to compute the severity map of a lung section using the SI function. Severity maps corresponding to 54 lung sections from control mice, mice induced with mild emphysema and mice induced with severe emphysema were computed, revealing differences between the distribution of SI in the three groups. The proposed methodology could then assist in the quantification of emphysema severity in animal models of pulmonary disease.


  • Automated pollen identification using microscopic imaging and texture analysis

    by J. Víctor Marcos, Rodrigo Nava, Gabriel Cristóbal, Rafael Redondo, Boris Escalante-Ramírez, Gloria Bueno, Óscar Déniz, Amelia González-Porto, Cristina Pardo, François Chung, et al.


  • ASSESSMENT OF FEATURE SELECTION AND CLASSIFICATION APPROACHES TO ENHANCE INFORMATION FROM OVERNIGHT OXIMETRY IN THE CONTEXT OF APNEA DIAGNOSIS

    by Daniel Álvarez, Roberto Hornero, J. Víctor Marcos, Niels Wessel, Thomas Penzel, Martin Glos, Félix DEL Campo

    This study is aimed at assessing the usefulness of different feature selection and classification methodologies in the context of sleep apnea hypopnea syndrome (SAHS) detection. Feature extraction, selection and classification stages were applied to analyze blood oxygen saturation (SaO2) recordings in order to simplify polysomnography (PSG), the gold standard diagnostic methodology for SAHS. Statistical, spectral and nonlinear measures were computed to compose the initial feature set. Principal component analysis (PCA), forward stepwise feature selection (FSFS) and genetic algorithms (GAs) were applied to select feature subsets. Fisher's linear discriminant (FLD), logistic regression (LR) and support vector machines (SVMs) were applied in the classification stage. Optimum classification algorithms from each combination of these feature selection and classification approaches were prospectively validated on datasets from two independent sleep units. FSFS + LR achieved the highest diagnostic performance using a small feature subset (4 features), reaching 83.2% accuracy in the validation set and 88.7% accuracy in the test set. Similarly, GAs + SVM also achieved high generalization capability using a small number of input features (7 features), with 84.2% accuracy on the validation set and 84.5% accuracy in the test set. Our results suggest that reduced subsets of complementary features (25% to 50% of total features) and classifiers with high generalization ability could provide high-performance screening tools in the context of SAHS.


  • Texture classification using discrete Tchebichef moments

    by J. Víctor Marcos, Gabriel Cristóbal

    In this paper, a method to characterize texture images based on discrete Tchebichef moments is presented. A global signature vector is derived from the moment matrix by taking into account both the magnitudes of the moments and their order. The performance of our method in several texture classification problems was compared with that achieved through other standard approaches. These include Haralick’s gray-level co-occurrence matrices, Gabor filters, and local binary patterns. An extensive texture classification study was carried out by selecting images with different contents from the Brodatz, Outex, and VisTex databases. The results show that the proposed method is able to capture the essential information about texture, showing comparable or even higher performance than conventional procedures. Thus, it can be considered as an effective and competitive technique for texture characterization.


  • Advances in Texture Analysis for Emphysema Classification

    by Rodrigo Nava, J. Victor Marcos, Boris Escalante-Ramírez, Gabriel Cristóbal, Laurent U. Perrinet, Raúl San José Estépar


  • Apnea-hypopnea index estimation from spectral analysis of airflow recordings

    by Gonzalo C. Gutierrez-Tobal, Roberto Hornero, Daniel Álvarez, J. Victor Marcos, Carlos Gómez, Félix del Campo

    This study focuses on the analysis of airflow (AF) recordings to help in sleep apnea-hypopnea syndrome (SAHS) diagnosis. The objective is to estimate the apnea-hypopnea index (AHI) by means of spectral features from AF data. Multiple linear regression (MLR) was used for this purpose. A training group is used to obtain two MLR models: the first one consisting of features obtained from the full PSDs (MLR full ) and the second one consisting of features from a new frequency band of interest (MLR band ). Then a test group is used to validate the final model. The correlation of spectral features and MLR models with AHI was compared by means of Pearson's coefficient (ρ). MLR band reached the highest ρ (0.809). Four different AHI decision thresholds were used to evaluate MLR band ability to distinguish the severity of SAHS. The accuracy achieved was higher as the threshold increased (69.7%, 75.3%, 80.9%, 87.6%) These results suggest that the automated estimation of AHI through spectral features can provide useful knowledge about SAHS severity.


  • Linear and nonlinear analysis of airflow recordings to help in sleep apnoea–hypopnoea syndrome diagnosis

    by G C Gutiérrez-Tobal, R Hornero, D Álvarez, J V Marcos, F del Campo

    This paper focuses on the analysis of single-channel airflow (AF) signal to help in sleep apnoea-hypopnoea syndrome (SAHS) diagnosis. The respiratory rate variability (RRV) series is derived from AF by measuring time between consecutive breathings. A set of statistical, spectral and nonlinear features are extracted from both signals. Then, the forward stepwise logistic regression (FSLR) procedure is used in order to perform feature selection and classification. Three logistic regression (LR) models are obtained by applying FSLR to features from AF, RRV and both signals simultaneously. The diagnostic performance of single features and LR models is assessed and compared in terms of sensitivity, specificity, accuracy and area under the receiver-operating characteristics curve (AROC). The highest accuracy (82.43%) and AROC (0.903) are reached by the LR model derived from the combination of AF and RRV features. This result suggests that AF and RRV provide useful information to detect SAHS.


  • Feature selection from nocturnal oximetry using genetic algorithms to assist in obstructive sleep apnoea diagnosis

    by Daniel Álvarez, Roberto Hornero, J. Víctor Marcos, Félix del Campo

    Nocturnal pulse oximetry (NPO) has demonstrated to be a powerful tool to help in obstructive sleep apnoea (OSA) detection. However, additional analysis is needed to use NPO alone as an alternative to nocturnal polysomnography (NPSG), which is the gold standard for a definitive diagnosis. In the present study, we exhaustively analysed a database of blood oxygen saturation (SpO(2)) recordings (80 OSA-negative and 160 OSA-positive) to obtain further knowledge on the usefulness of NPO. Population set was randomly divided into training and test sets. A feature extraction stage was carried out: 16 features (time and frequency statistics and spectral and nonlinear features) were computed. A genetic algorithm (GA) approach was applied in the feature selection stage. Our methodology achieved 87.5% accuracy (90.6% sensitivity and 81.3% specificity) in the test set using a logistic regression (LR) classifier with a reduced number of complementary features (3 time domain statistics, 1 frequency domain statistic, 1 conventional spectral feature and 1 nonlinear feature) automatically selected by means of GAs. Our results improved diagnostic performance achieved with conventional oximetric indexes commonly used by physicians. We concluded that GAs could be an effective and robust tool to search for essential oximetric features that could enhance NPO in the context of OSA diagnosis.


  • Prospective evaluation of logistic regression models from overnight oximetry to assist in sleep apnea diagnosis

    by Daniel Alvarez, Roberto Hornero, J. Victor Marcos, Thomas Penzel, Felix del Campo, Niels Wessel

    This study focused on prospectively testing diagnostic performance of different logistic regression (LR) models in the context of sleep apnea hypopnea syndrome (SAHS) detection from blood oxygen saturation (SaO 2 ) recordings. Feature extraction, selection and classification procedures were applied. Time, frequency, linear and nonlinear analyses were carried out to compose the initial feature set. Forward stepwise logistic regression (FSLR) was applied for feature selection. LR was used to measure performance classification of single features and an optimum feature subset from FSLR. A training set composed of 148 recordings from patients suspected of suffering from SAHS was used to obtain LR models, which were further validated on a dataset composed of 50 recordings from normal healthy subjects and 21 recordings from SAHS patients, all derived from an independent sleep unit. Diagnostic performance of one-feature LR models from oximetry in the training set significantly changed on further assessments in the test set. On the other hand, FSLR provided a more general LR model in the context of SAHS, which reached an accuracy of 89.7% on the training set and 87.3% on the test set.