Shu Ichihara
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Shu Ichihara has a total of 204 co-authors. Here are the top co-authors by number of shared publications:
Suzuko Moritani
Shiga University of Medical Science, Otsu, Japan
11 shared publicationsYasuyuki Sato
National Hospital Organization Nagoya Medical Center, Nagoya, Japan
11 shared publicationsMasaki Hasegawa
Nagoya Medical Center
10 shared publications- Suzuko Moritani
Pathology, Nagoya Medical Center, Nagoya, Japan
10 shared publications Aya Kato
National Hospital Organization Nagoya Medical Center, Nagoya, Japan
8 shared publicationsTakako Hayashi
National Hospital Organization Nagoya Medical Center, Nagoya, Japan
8 shared publications
Latest Publications
- 20 March 2023
- Published by AIP Publishing in Applied Physics Letters
- Vol. 122 (12) , 123702
Superimposed wavefront imaging of diffraction-enhanced x-rays: A method to achieve higher resolution in crystal analyzer-based x-ray phase-contrast imaging
In conventional phase-contrast imaging methods, an optimum distance that is essential for x-ray interference and wavefront separation must be maintained between the object and the x-ray detector. This distance determines the apparent focal size of the x-ray source and affects spatial resolution of the system. To improve the spatial resolution, we proposed a phase-contrast imaging method that eliminates the distance required for x-ray interference and wavefront separation by placing a scintillator in close contact with a Laue angle analyzer (LAA). We mathematically described the image formed by superposition of diffracted beams in two directions of LAA and introduced a method to reconstruct tomographic sections from multiple projections captured by this setup. We experimentally demonstrated the validity and the usefulness of the proposed method. Using a physical phantom, we showed that the proposed method provides higher spatial resolution than conventional x-ray dark-field imaging. The proposed method may be useful for studying and elucidating the fine 3D microanatomy and histopathology of various biological specimens.
- 20 March 2023
- Published by AIP Publishing in Applied Physics Letters
- Vol. 122 (12) , 123702
Superimposed wavefront imaging of diffraction-enhanced x-rays: A method to achieve higher resolution in crystal analyzer-based x-ray phase-contrast imaging
In conventional phase-contrast imaging methods, an optimum distance that is essential for x-ray interference and wavefront separation must be maintained between the object and the x-ray detector. This distance determines the apparent focal size of the x-ray source and affects spatial resolution of the system. To improve the spatial resolution, we proposed a phase-contrast imaging method that eliminates the distance required for x-ray interference and wavefront separation by placing a scintillator in close contact with a Laue angle analyzer (LAA). We mathematically described the image formed by superposition of diffracted beams in two directions of LAA and introduced a method to reconstruct tomographic sections from multiple projections captured by this setup. We experimentally demonstrated the validity and the usefulness of the proposed method. Using a physical phantom, we showed that the proposed method provides higher spatial resolution than conventional x-ray dark-field imaging. The proposed method may be useful for studying and elucidating the fine 3D microanatomy and histopathology of various biological specimens.
- 23 February 2021
- Published by Springer Nature in Molecular Imaging and Biology
- Vol. 23 (4) , 481-494
X-ray Dark-Field Imaging (XDFI)—a Promising Tool for 3D Virtual Histopathology
X-ray dark-field imaging (XDFI) utilizing a thin silicon crystal under Laue case enables visualizing three-dimensional (3D) morphological alterations of human tissue. XDFI uses refraction-contrast derived from phase shift rather than absorption as the main X-ray image contrast source to render 2D and 3D images of tissue specimens in unprecedented detail. The unique features of XDFI are its extremely high sensitivity (approximately 1000:1 compared to absorption for soft tissues under X-ray energy of around 20 keV, theoretically) and excellent resolution (8.5 μm) without requiring contrast medium or staining. Thus, XDFI-computed tomography can generate 3D virtual histological images equivalent to those of stained histological sections pathologists observe under low-power light microscopy as far as organs and tissues selected as samples in preliminary studies. This paper reviews the fundamental principles and the potential of XDFI, describes two optical setups for XDFI with examples, illustrates features of XDFI that are salient for histopathology, and presents XDFI examples of refraction-contrast images of atherosclerotic plaques, musculoskeletal tissue, neuronal tissue, and breast cancer specimens. Availability of this X-ray imaging in routine histopathological evaluations of tissue specimens would help guide clinical decision making by highlighting suspicious areas in unstained, thick sections for further sampling and analysis using conventional histopathological techniques. XDFI is a promising tool for 3D virtual histopathology.
- 23 February 2021
- Published by Springer Nature in Molecular Imaging and Biology
- Vol. 23 (4) , 481-494
X-ray Dark-Field Imaging (XDFI)—a Promising Tool for 3D Virtual Histopathology
X-ray dark-field imaging (XDFI) utilizing a thin silicon crystal under Laue case enables visualizing three-dimensional (3D) morphological alterations of human tissue. XDFI uses refraction-contrast derived from phase shift rather than absorption as the main X-ray image contrast source to render 2D and 3D images of tissue specimens in unprecedented detail. The unique features of XDFI are its extremely high sensitivity (approximately 1000:1 compared to absorption for soft tissues under X-ray energy of around 20 keV, theoretically) and excellent resolution (8.5 μm) without requiring contrast medium or staining. Thus, XDFI-computed tomography can generate 3D virtual histological images equivalent to those of stained histological sections pathologists observe under low-power light microscopy as far as organs and tissues selected as samples in preliminary studies. This paper reviews the fundamental principles and the potential of XDFI, describes two optical setups for XDFI with examples, illustrates features of XDFI that are salient for histopathology, and presents XDFI examples of refraction-contrast images of atherosclerotic plaques, musculoskeletal tissue, neuronal tissue, and breast cancer specimens. Availability of this X-ray imaging in routine histopathological evaluations of tissue specimens would help guide clinical decision making by highlighting suspicious areas in unstained, thick sections for further sampling and analysis using conventional histopathological techniques. XDFI is a promising tool for 3D virtual histopathology.
- Open Access
- 1 March 2020
- Published by SPIE-Intl Soc Optical Eng in Journal of Medical Imaging
- Vol. 7 (02) , 026001-15
Cardiac fiber tracking on super high-resolution CT images: a comparative study
Deep understanding of the cardiac fiber structure in the left ventricle (LV) is required to understand cardiac anatomy and such diseases as heart failure. 6.5 million people experienced heart failure between 2011 and 2014 in the United States.1 Although the fiber structure may also be changed by heart failure, the details have not been clearly investigated yet. High-resolution cardiac imaging and analysis methods in three-dimensional (3-D) space are needed.
- 1 March 2020
- Published by SPIE-Intl Soc Optical Eng in Journal of Medical Imaging
- Vol. 7 (02) , 026001-15
Open AccessCardiac fiber tracking on super high-resolution CT images: a comparative study
Deep understanding of the cardiac fiber structure in the left ventricle (LV) is required to understand cardiac anatomy and such diseases as heart failure. 6.5 million people experienced heart failure between 2011 and 2014 in the United States.1 Although the fiber structure may also be changed by heart failure, the details have not been clearly investigated yet. High-resolution cardiac imaging and analysis methods in three-dimensional (3-D) space are needed.
- Open Access
- 7 May 2019
- Published by Wiley in Cancer Medicine
- Vol. 8 (7) , 3359-3369
Polygon method: A systematic margin assessment for breast conservation
Background: Radiation therapy (RT) for women with ductal carcinoma in situ (DCIS) undergoing breast‐conserving surgery (BCS) may be overtreatment for some, especially for those in which DCIS is eradicated, and ipsilateral breast tumor recurrence (IBTR) risk approaches the contralateral breast cancer (CBC) level. The aim of this study was to clarify whether the polygon method, a new systematic method of en face (tangential, shaved) margin assessment, can identify a subset of DCIS that can be safely treated by BCS alone.Methods: A key tool of the polygon method is an adjustable mold that prevents the “pancake phenomenon” (flattening) of breast tissue after surgical removal so that the specimen is fixed in the shape of a polygonal prism. This preanalytical procedure enables us to command a panoramic view of entire en face margins 3‐5‐mm deep from the real peripheral cut surfaces. Competing risk analysis was used to quantify rates of IBTR and CBC and to evaluate risk factors.Results: From 2000 to 2013, we identified 146 DCIS patients undergoing BCS with a contralateral breast at risk. In 100 DCIS patients whose margin was negative by the polygon method, 5 IBTR (3 DCIS and 2 invasive ductal carcinoma [IDC]) and 10 CBC (6 DCIS and 4 IDC) cases were identified during a median follow‐up of 7.6 years (range, 0.9‐17.4). Five‐ and 10‐year cumulative incidence rates were 3.0% and 5.3% for IBTR, and 7.1% and 13.3% for CBC, respectively. Thus, patients with a negative margin consistently showed at least twofold lower IBTR than CBC despite omission of RT.Conclusions: Japanese women classified with a negative margin by the polygon method show a very low risk of IBTR and account for approximately half of CBC cases. In this subset of DCIS patients, additional RT is not beneficial.
- 7 May 2019
- Published by Wiley in Cancer Medicine
- Vol. 8 (7) , 3359-3369
Open AccessPolygon method: A systematic margin assessment for breast conservation
Background: Radiation therapy (RT) for women with ductal carcinoma in situ (DCIS) undergoing breast‐conserving surgery (BCS) may be overtreatment for some, especially for those in which DCIS is eradicated, and ipsilateral breast tumor recurrence (IBTR) risk approaches the contralateral breast cancer (CBC) level. The aim of this study was to clarify whether the polygon method, a new systematic method of en face (tangential, shaved) margin assessment, can identify a subset of DCIS that can be safely treated by BCS alone.Methods: A key tool of the polygon method is an adjustable mold that prevents the “pancake phenomenon” (flattening) of breast tissue after surgical removal so that the specimen is fixed in the shape of a polygonal prism. This preanalytical procedure enables us to command a panoramic view of entire en face margins 3‐5‐mm deep from the real peripheral cut surfaces. Competing risk analysis was used to quantify rates of IBTR and CBC and to evaluate risk factors.Results: From 2000 to 2013, we identified 146 DCIS patients undergoing BCS with a contralateral breast at risk. In 100 DCIS patients whose margin was negative by the polygon method, 5 IBTR (3 DCIS and 2 invasive ductal carcinoma [IDC]) and 10 CBC (6 DCIS and 4 IDC) cases were identified during a median follow‐up of 7.6 years (range, 0.9‐17.4). Five‐ and 10‐year cumulative incidence rates were 3.0% and 5.3% for IBTR, and 7.1% and 13.3% for CBC, respectively. Thus, patients with a negative margin consistently showed at least twofold lower IBTR than CBC despite omission of RT.Conclusions: Japanese women classified with a negative margin by the polygon method show a very low risk of IBTR and account for approximately half of CBC cases. In this subset of DCIS patients, additional RT is not beneficial.
- 7 May 2018
- Published by Springer Nature in Virchows Archiv
- Vol. 473 (2) , 235-239
β-catenin (CTNNB1) mutation and LEF1 expression in sinonasal glomangiopericytoma (sinonasal-type hemangiopericytoma)
Sinonasal glomangiopericytoma (SN-GPC) is an uncommon mesenchymal tumor with myoid differentiation. Recently, mutations in exon 3 of the gene coding for β-catenin (CTNNB1) and its nuclear expression were discovered in SN-GPC. β-catenin protein is a key regulatory molecule of the canonical Wnt signaling pathway. The expression of β-catenin target proteins is not well characterized in SN-GPC. We examined three SN-GPCs by immunohistochemistry and CTNNB1 mutation analysis. All cases expressed nuclear β-catenin. We identified CTNNB1 exon 3 mutations in two analyzable cases. Lymphoid enhancer-binding factor 1 (LEF1), a protein downstream from β-catenin, was also expressed in all cases. Our results further characterized the activation of the Wnt signaling pathway caused by CTNNB1 exon 3 mutation and suggest the utility of LEF1 immunohistochemistry in the differential diagnosis of SN-GPC.
- 7 May 2018
- Published by Springer Nature in Virchows Archiv
- Vol. 473 (2) , 235-239
β-catenin (CTNNB1) mutation and LEF1 expression in sinonasal glomangiopericytoma (sinonasal-type hemangiopericytoma)
Sinonasal glomangiopericytoma (SN-GPC) is an uncommon mesenchymal tumor with myoid differentiation. Recently, mutations in exon 3 of the gene coding for β-catenin (CTNNB1) and its nuclear expression were discovered in SN-GPC. β-catenin protein is a key regulatory molecule of the canonical Wnt signaling pathway. The expression of β-catenin target proteins is not well characterized in SN-GPC. We examined three SN-GPCs by immunohistochemistry and CTNNB1 mutation analysis. All cases expressed nuclear β-catenin. We identified CTNNB1 exon 3 mutations in two analyzable cases. Lymphoid enhancer-binding factor 1 (LEF1), a protein downstream from β-catenin, was also expressed in all cases. Our results further characterized the activation of the Wnt signaling pathway caused by CTNNB1 exon 3 mutation and suggest the utility of LEF1 immunohistochemistry in the differential diagnosis of SN-GPC.
- 1 December 2017
- Published by Elsevier in Physica Medica
- Vol. 44, 236-242
Imaging with ultra-small-angle X-ray scattering using a Laue-case analyzer and its application to human breast tumors
- 1 December 2017
- Published by Elsevier in Physica Medica
- Vol. 44, 236-242
Imaging with ultra-small-angle X-ray scattering using a Laue-case analyzer and its application to human breast tumors
- 27 September 2017
- Published by Springer Nature in Breast Cancer
- Vol. 25 (2) , 159-166
Diagnostic performance of digital breast tomosynthesis and full-field digital mammography with new reconstruction and new processing for dose reduction
The main barrier to adoption of digital breast tomosynthesis (DBT) plus full-field digital mammography (FFDM) is radiation exposure dose. The purpose of this study was to evaluate the diagnostic performance of DBT plus FFDM, both with newly developed technology (nd), at a dose comparable to that of the conventional FFDM alone.
- 27 September 2017
- Published by Springer Nature in Breast Cancer
- Vol. 25 (2) , 159-166
Diagnostic performance of digital breast tomosynthesis and full-field digital mammography with new reconstruction and new processing for dose reduction
The main barrier to adoption of digital breast tomosynthesis (DBT) plus full-field digital mammography (FFDM) is radiation exposure dose. The purpose of this study was to evaluate the diagnostic performance of DBT plus FFDM, both with newly developed technology (nd), at a dose comparable to that of the conventional FFDM alone.
- 26 August 2017
- Published by Morressier GmbH
Impact of crystal analyser-based phase contrast X-ray computed tomography on histopathology
- 26 August 2017
- Published by Morressier GmbH
Impact of crystal analyser-based phase contrast X-ray computed tomography on histopathology