PSPam Susi

Pam Susi

*This is an algorithmically generated author record based on publicly available information.

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Pam Susi has a total of 40 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Implications of applying cumulative risk assessment to the workplace

    by Mary A. Fox, Kristen Spicer, L. Casey Chosewood, Pam Susi, Douglas O. Johns, G. Scott Dotson


  • The power of local action in occupational health: the adoption of local exhaust ventilation in the Chicago tuckpointing trade

    by Marc Weinstein, Pam Susi, Mark Goldberg

    Background: Silica is a pervasive and potentially deadly occupational hazard in construction. The occupational risk posed by silica has long been known, but efforts to use engineering controls to minimize dust generation in tuckpointing operations, a masonry restoration specialty, have been slow. Objectives: The objective of this study is to explore how local innovation in occupational safety and health may emerge, absent the establishment of national standards. Method:This study uses a case study to explore the adoption of local exhaust ventilation in tuckpointing operations in the Chicago area. Sources of data for this research include interviews with a diverse range of key informants and the review of archival material. Results: This case study found local unions, municipal regulators, contractors, and major public users of construction services played a central role in the events and milestones that led to the early adoption of local exhaust ventilation in Chicago. The adoption of local exhaust ventilation technology in Chicago demonstrates the potential for local actors to fill an important void when rulemaking in vital areas of occupational of health impedes effective national regulation.


  • Open Access

    Silica Measurement with High Flow Rate Respirable Size Selective Samplers: A Field Study

    by Taekhee Lee, Martin Harper, Michael Kashon, Larry A. Lee, Catherine B. Healy, Marie A. Coggins, Pam Susi, Andrew O’brien

    High and low flow rate respirable size selective samplers including the CIP10-R (10 l min−1), FSP10 (11.2 l min−1), GK2.69 (4.4 l min−1), 10-mm nylon (1.7 l min−1), and Higgins-Dewell type (2.2 l min−1) were compared via side-by-side sampling in workplaces for respirable crystalline silica measurement. Sampling was conducted at eight different occupational sites in the USA and five different stonemasonry sites in Ireland. A total of 536 (268 pairs) personal samples and 55 area samples were collected. Gravimetric analysis was used to determine respirable dust mass and X-ray diffraction analysis was used to determine quartz mass. Ratios of respirable dust mass concentration, quartz mass concentration, respirable dust mass, and quartz mass from high and low flow rate samplers were compared. In general, samplers did not show significant differences greater than 30% in respirable dust mass concentration and quartz mass concentration when outliers (ratio 3.0) were removed from the analysis. The frequency of samples above the limit of detection and limit of quantification of quartz was significantly higher for the CIP10-R and FSP10 samplers compared to low flow rate samplers, while the GK2.69 cyclone did not show significant difference from low flow rate samplers. High flow rate samplers collected significantly more respirable dust and quartz than low flow rate samplers as expected indicating that utilizing high flow rate samplers might improve precision in quartz measurement. Although the samplers did not show significant differences in respirable dust and quartz concentrations, other practical attributes might make them more or less suitable for personal sampling.


  • Case Study

    by Michael R. Cooper, Pam Susi, David Rempel

    (2012). Case Study. Journal of Occupational and Environmental Hygiene: Vol. 9, No. 2, pp. D35-D41.


  • Effectiveness of Dust Control Methods for Crystalline Silica and Respirable Suspended Particulate Matter Exposure During Manual Concrete Surface Grinding

    by Farhang Akbar-Khanzadeh, Sheryl A. Milz, Cynthia D. Wagner, Michael S. Bisesi, April L. Ames, Sadik Khuder, Pam Susi, Mahboubeh Akbar-Khanzadeh

    Concrete grinding exposes workers to unacceptable levels of crystalline silica dust, known to cause diseases such as silicosis and possibly lung cancer. This study examined the influence of major factors of exposure and effectiveness of existing dust control methods by simulating field concrete grinding in an enclosed workplace laboratory. Air was monitored during 201 concrete grinding sessions while using a variety of grinders, accessories, and existing dust control methods, including general ventilation (GV), local exhaust ventilation (LEV), and wet grinding. Task-specific geometric mean (GM) of respirable crystalline silica dust concentrations (mg/m 3 for LEV:HEPA-, LEV:Shop-vac-, wet-, and uncontrolled-grinding, while GV was off/on, were 0.17/0.09, 0.57/0.13, 1.11/0.44, and 23.1/6.80, respectively. Silica dust concentrations (mg/m 3 using 100–125 mm (4–5 inch) and 180 mm (7 inch) grinding cups were 0.53/0.22 and 2.43/0.56, respectively. GM concentrations of silica dust were significantly lower for (1) GV on (66.0%) vs. off, and (2) LEV:HEPA- (99.0%), LEV:Shop-vac- (98.1%) or wet- (94.4%) vs. uncontrolled-grinding. Task-specific GM of respirable suspended particulate matter (RSP) concentrations (mg/m 3 for LEV:HEPA-, LEV:Shop-vac-, wet-, and uncontrolled grinding, while GV was off/on, were 1.58/0.63, 7.20/1.15, 9.52/4.13, and 152/47.8, respectively. GM concentrations of RSP using 100–125 mm and 180 mm grinding cups were 4.78/1.62 and 22.2/5.06, respectively. GM concentrations of RSP were significantly lower for (1) GV on (70.2%) vs. off, and (2) LEV:HEPA- (98.9%), LEV:Shop-vac- (96.9%) or wet- (92.6%) vs. uncontrolled grinding. Silica dust and RSP were not significantly affected by (1) orientation of grinding surfaces (vertical vs. inclined); (2) water flow rates for wet grinding; (3) length of task-specific sampling time; or, (4) among cup sizes of 100, 115 or 125 mm. No combination of factors or control methods reduced an 8-hr exposure level to below the recommended criterion of 0.025 mg/m 3 for crystalline silica, requiring further refinement in engineering controls, administrative controls, or the use of respirators.


  • Hexavalent Chromium Exposure and Control in Welding Tasks

    by John D. Meeker, Pam Susi, Michael R. Flynn

    Studies of exposure to the lung carcinogen hexavalent chromium (CrVI) from welding tasks are limited, especially within the construction industry where overexposure may be common. In addition, despite the OSHA requirement that the use of engineering controls such as local exhaust ventilation (LEV) first be considered before relying on other strategies to reduce worker exposure to CrVI, data on the effectiveness of LEV to reduce CrVI exposures from welding are lacking. The goal of the present study was to characterize breathing zone air concentrations of CrVI during welding tasks and primary contributing factors in four datasets: (1) OSHA compliance data; (2) a publicly available database from The Welding Institute (TWI); (3) field survey data of construction welders collected by the Center for Construction Research and Training (CPWR); and (4) controlled welding trials conducted by CPWR to assess the effectiveness of a portable LEV unit to reduce CrVI exposure. In the OSHA (n = 181) and TWI (n = 124) datasets, which included very few samples from the construction industry, the OSHA permissible exposure level (PEL) for CrVI (5 μg/m3) was exceeded in 9% and 13% of samples, respectively. CrVI concentrations measured in the CPWR field surveys (n = 43) were considerably higher, and 25% of samples exceeded the PEL. In the TWI and CPWR datasets, base metal, welding process, and LEV use were important predictors of CrVI concentrations. Only weak-to-moderate correlations were found between total particulate matter and CrVI, suggesting that total particulate matter concentrations are not a good surrogate for CrVI exposure in retrospective studies. Finally, in the controlled welding trials, LEV reduced median CrVI concentrations by 68% (p = 0.02). In conclusion, overexposure to CrVI in stainless steel welding is likely widespread, especially in certain operations such as shielded metal arc welding, which is commonly used in construction. However, exposure could be substantially reduced with proper use of LEV.


  • Manganese, Iron, and Total Particulate Exposures to Welders

    by Michael R. Flynn, Pam Susi

    Welders are exposed to a variety of metal fumes, including manganese, that may elevate the risk for neurological disease. This study examines several large data sets to characterize manganese, iron, and total particulate mass exposures resulting from welding operations. The data sets contained covariates for a variety of exposure modifiers, including the presence of ventilation, the degree of confinement, and the location of the personal sampler (i.e., behind or in front of the welding helmet). The analysis suggests that exposures to manganese are frequently at or above the current ACGIH® threshold limit value of 0.2 mg/m3. In addition, there is evidence that local exhaust ventilation can control the exposures to manganese and total fume but that mechanical ventilation may not. The data suggest that higher exposures are associated with a greater degree of enclosure, particularly when local exhaust ventilation is absent. Samples taken behind the helmet were, in general, lower than those measured outside of it. There were strong correlations among manganese, iron, and total particulate mass exposures, suggesting simple equations to estimate one fume component from any of the others.


  • Manganese and Welding Fume Exposure and Control in Construction

    by John D. Meeker, Pam Susi, Michael R. Flynn

    Overexposure to welding fume constituents, particularly manganese, is of concern in the construction industry due to the prevalence of welding and the scarcity of engineering controls. The control effectiveness of a commercially available portable local exhaust ventilation (LEV) unit was assessed. It consisted of a portable vacuum and a small bell-shaped hood connected by a flexible 2 inch (50.8 mm) diameter hose, in both experimental and field settings. The experimental testing was done in a semienclosed booth at a pipefitter training facility. Five paired trials of LEV control vs. no control, each approximately 1 hr in duration and conducted during two successive welds of 6 inch (152.4 mm) diameter carbon steel pipe were run in random order. Breathing zone samples were collected outside the welding hood during each trial. In the field scenario, full-shift breathing zone samples were collected from two pipefitters welding carbon steel pipe for a chiller installation on a commercial construction project. Eight days of full-shift sampling were conducted on both workers (n = 16), and the LEV was used by one of the two workers on an alternating basis for 7 of the days. All samples were collected with personal sample pumps calibrated at 2 L/min. Filter cassettes were analyzed for total particulate and manganese concentration by a certified laboratory. In the experimental setting, use of the portable LEV resulted in a 75% reduction in manganese exposure (mean 13 μg/m 3 vs. 51 μ g/m 3 ; p < 0.05) and a 60% reduction in total particulate (mean 0.74 mg/m 3 vs. 1.83 mg/m 3 ; p < 0.05). In the field setting, LEV use resulted in a 53% reduction in manganese exposure (geometric mean 46 μ g/m 3 vs. 97 μ g/m 3 ; p < 0.05) but only a 10% reduction in total particulate (geometric mean 4.5 mg/m 3 vs. 5.0 mg/m 3 ; p > 0.05). These results demonstrate that LEV use can reduce manganese exposure associated with welding tasks in construction.