Kintur Sanghvi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Kintur Sanghvi has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
Courtney Krathen
Department of Interventional Cardiology, Deborah Heart & Lung Center, United States of America
2 shared publicationsJoseph Kusick
Deborah Heart & Lung Ctr, Dept Intervent Cardiol, Browns Mills, NJ 08015 USA
2 shared publications- Tejas Patel
Apex Heart Institute, Ahmedabad, India
2 shared publications Vincent Varghese
Department of Interventional Cardiology, Deborah Heart & Lung Center, United States of America
2 shared publications- Courtney Walsh
Deborah Heart and Lung Center, Brown Mills, New Jersey
1 shared publication John Coppola
NYU Langone Medical Center New York New York
1 shared publication
Latest Publications
- 1 January 2021
- Published by Elsevier in Cardiovascular Revascularization Medicine
- Vol. 22, 91-97
Evaluation of Railway Sheathless Access System for Transradial Coronary and Peripheral Interventions
- 1 January 2021
- Published by Elsevier in Cardiovascular Revascularization Medicine
- Vol. 22, 91-97
Evaluation of Railway Sheathless Access System for Transradial Coronary and Peripheral Interventions
- 1 November 2019
- Published by HMP Communications, LLC in Journal of Invasive Cardiology
- Vol. 31 (11) , E331-E332
Transradial repair of type IA endoleak
An 81-year-old Caucasian male with a known abdominal aortic aneurysm (AAA) was referred to the endovascular clinic. One month after successful endovascular repair, surveillance CTA showed endoleak with presence of contrast within the aneurysmal sac. An elective repair was performed.
- 1 November 2019
- Published by HMP Communications, LLC in Journal of Invasive Cardiology
- Vol. 31 (11) , E331-E332
Transradial repair of type IA endoleak
An 81-year-old Caucasian male with a known abdominal aortic aneurysm (AAA) was referred to the endovascular clinic. One month after successful endovascular repair, surveillance CTA showed endoleak with presence of contrast within the aneurysmal sac. An elective repair was performed.
- 1 December 2018
- Published by Elsevier in Cardiovascular Revascularization Medicine
- Vol. 19 (8) , 934-938
Effect of hemostatic device on radial artery occlusion: A randomized comparison of compression devices in the radial hemostasis study
- 1 December 2018
- Published by Elsevier in Cardiovascular Revascularization Medicine
- Vol. 19 (8) , 934-938
Effect of hemostatic device on radial artery occlusion: A randomized comparison of compression devices in the radial hemostasis study
- 1 September 2018
- Vol. 30 (9) , 334-340
Retrograde Tibio-Pedal Access for Revascularization of Lower-Extremity Peripheral Artery Disease Using a 6 Fr Slender Sheath: The "Pedal-First" Pilot Project
Objective. We studied the safety and efficacy of tibio-pedal access (TPA) as the sole primary access (ie, the "pedal-first" strategy) for revascularization of peripheral artery disease (PAD). Methods. We reviewed a prospectively maintained database of patients where TPA was used as a primary access for retrograde diagnostic angiography and intervention. Patients suffering from symptomatic PAD and abnormal non-invasive testing were treated with the intention of using only ipsilateral TPA if there was antegrade flow in one of the three run-off vessels on ultrasound (US). Additional radial or femoral access (FA) was used only if needed for successful revascularization. TPA was achieved with US guidance using a 6 Fr thin-walled hydrophilic sheath. Patency of the accessed tibio-pedal artery was evaluated with US at 30 days. Results. The pedal-first approach was attempted for 41 limbs in 36 patients. The overall rate of successful revascularization was 95% (39 limbs). TPA was successfully used in all 39 limbs and "pedal-only" success occurred in 30 limbs (77%). Two procedures were unsuccessful in revascularizing target-vessel occlusion despite dual access. Patients without FA were able to ambulate at an average of 3 hours post procedure. No acute vascular access-related complications were noted. Each accessed tibio-pedal artery was patent on US evaluation at 30 days. Conclusion. The pedal-first approach of using TPA with a 6 Fr thin-walled sheath as a primary access and as the only access for diagnosis and intervention of PAD is safe and highly successful in carefully selected patients.
- 1 September 2018
- Vol. 30 (9) , 334-340
Retrograde Tibio-Pedal Access for Revascularization of Lower-Extremity Peripheral Artery Disease Using a 6 Fr Slender Sheath: The "Pedal-First" Pilot Project
Objective. We studied the safety and efficacy of tibio-pedal access (TPA) as the sole primary access (ie, the "pedal-first" strategy) for revascularization of peripheral artery disease (PAD). Methods. We reviewed a prospectively maintained database of patients where TPA was used as a primary access for retrograde diagnostic angiography and intervention. Patients suffering from symptomatic PAD and abnormal non-invasive testing were treated with the intention of using only ipsilateral TPA if there was antegrade flow in one of the three run-off vessels on ultrasound (US). Additional radial or femoral access (FA) was used only if needed for successful revascularization. TPA was achieved with US guidance using a 6 Fr thin-walled hydrophilic sheath. Patency of the accessed tibio-pedal artery was evaluated with US at 30 days. Results. The pedal-first approach was attempted for 41 limbs in 36 patients. The overall rate of successful revascularization was 95% (39 limbs). TPA was successfully used in all 39 limbs and "pedal-only" success occurred in 30 limbs (77%). Two procedures were unsuccessful in revascularizing target-vessel occlusion despite dual access. Patients without FA were able to ambulate at an average of 3 hours post procedure. No acute vascular access-related complications were noted. Each accessed tibio-pedal artery was patent on US evaluation at 30 days. Conclusion. The pedal-first approach of using TPA with a 6 Fr thin-walled sheath as a primary access and as the only access for diagnosis and intervention of PAD is safe and highly successful in carefully selected patients.
- 1 September 2018
- Published by Elsevier in JACC: Cardiovascular Interventions
- Vol. 11 (17) , e137-e140
Intervention of Prohibitive Aortic and Iliac Atherosclerotic Stenosis to Allow Successful Transfemoral Transcatheter Aortic Valve Replacement
- 1 September 2018
- Published by Elsevier in JACC: Cardiovascular Interventions
- Vol. 11 (17) , e137-e140
Intervention of Prohibitive Aortic and Iliac Atherosclerotic Stenosis to Allow Successful Transfemoral Transcatheter Aortic Valve Replacement
- 1 March 2018
- Published by Wiley in Journal of Cardiac Surgery
- Vol. 33 (3) , 139-141
Ostial left main occlusion following surgical aortic valve replacement (SAVR)
- 1 March 2018
- Published by Wiley in Journal of Cardiac Surgery
- Vol. 33 (3) , 139-141
Ostial left main occlusion following surgical aortic valve replacement (SAVR)
- 22 July 2017
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 90 (6) , 996-999
Thrombolysis for pulmonary embolism using the superficial veins of the upper extremity
This report describes a novel approach of accessing the superficial veins of the upper extremity for the treatment of pulmonary emboli (PE) with an ultrasound enhanced thrombolytic infusion catheter. In a patient suffering from saddle PE and impending right heart failure, separate basilic and cephalic venous access sites in the right arm were utilized to insert EKOS EndoWave Infusion Catheter (EKOS Corporation, Bothell, WA) insertion in each pulmonary artery (PA). This technique could be advantageous, particularly for patients at high risk for access site complications and those unable to lie supine for prolonged duration of infusion therapy.
- 22 July 2017
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 90 (6) , 996-999
Thrombolysis for pulmonary embolism using the superficial veins of the upper extremity
This report describes a novel approach of accessing the superficial veins of the upper extremity for the treatment of pulmonary emboli (PE) with an ultrasound enhanced thrombolytic infusion catheter. In a patient suffering from saddle PE and impending right heart failure, separate basilic and cephalic venous access sites in the right arm were utilized to insert EKOS EndoWave Infusion Catheter (EKOS Corporation, Bothell, WA) insertion in each pulmonary artery (PA). This technique could be advantageous, particularly for patients at high risk for access site complications and those unable to lie supine for prolonged duration of infusion therapy.
- 1 December 2015
- Vol. 27 (12) , E308-11
Hemodynamic Assessment of Severe Aortic Stenosis via Transradial Approach is Safe.
Patients with a discrepancy between clinical presentation and echocardiographic severity of aortic stenosis require invasive hemodynamic assessment. The comparative safety and feasibility of transradial cardiac catheterization in comparison with the traditional transfemoral approach in this usually complex subset of patients is not known. We sought to evaluate the safety, feasibility, and time to cross severely stenosed aortic valves via radial approach. All patients who were successfully assessed for aortic stenosis with a dual-lumen catheter and found to have severe aortic stenosis (calculated aortic valve area <1.0 cm2) in the last 2 years at our institution were retrospectively evaluated. Demographic, clinical, and procedural data were compared between the TF group (femoral arterial and venous access) and TR group (radial artery and basilic or cephalic vein access). A total of 176 patients underwent left and right heart catheterization using femoral access, while 58 patients had their procedures performed via radial artery and arm vein access. Fluoroscopy time was comparable between TR and TF groups (14.97 ± 4.6 minutes vs 12.90 ± 3.9 minutes, respectively; P=.23), as was the time to cross the aortic valve (132 ± 209 seconds vs 128 ± 226 seconds, respectively; P=.39). Incidence of cerebrovascular events was not different between the two groups (2.3% vs 1.75%, respectively; P=.14). Access-site complications were significantly higher in the TF group vs the TR group (5.11% vs 0%, respectively; P<.01). Transradial retrograde crossing of severely stenosed aortic valve is feasible using ordinary equipment, with reduced access-site related complications.
- 1 December 2015
- Vol. 27 (12) , E308-11
Hemodynamic Assessment of Severe Aortic Stenosis via Transradial Approach is Safe.
Patients with a discrepancy between clinical presentation and echocardiographic severity of aortic stenosis require invasive hemodynamic assessment. The comparative safety and feasibility of transradial cardiac catheterization in comparison with the traditional transfemoral approach in this usually complex subset of patients is not known. We sought to evaluate the safety, feasibility, and time to cross severely stenosed aortic valves via radial approach. All patients who were successfully assessed for aortic stenosis with a dual-lumen catheter and found to have severe aortic stenosis (calculated aortic valve area <1.0 cm2) in the last 2 years at our institution were retrospectively evaluated. Demographic, clinical, and procedural data were compared between the TF group (femoral arterial and venous access) and TR group (radial artery and basilic or cephalic vein access). A total of 176 patients underwent left and right heart catheterization using femoral access, while 58 patients had their procedures performed via radial artery and arm vein access. Fluoroscopy time was comparable between TR and TF groups (14.97 ± 4.6 minutes vs 12.90 ± 3.9 minutes, respectively; P=.23), as was the time to cross the aortic valve (132 ± 209 seconds vs 128 ± 226 seconds, respectively; P=.39). Incidence of cerebrovascular events was not different between the two groups (2.3% vs 1.75%, respectively; P=.14). Access-site complications were significantly higher in the TF group vs the TR group (5.11% vs 0%, respectively; P<.01). Transradial retrograde crossing of severely stenosed aortic valve is feasible using ordinary equipment, with reduced access-site related complications.