Zhenli Zhu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Zhenli Zhu has a total of 194 co-authors. Here are the top co-authors by number of shared publications:
Hongtao Zheng
Faculty of Materials Science and Chemistry, China University of Geosciences, Wuhan 430074, China
43 shared publicationsShenghong Hu
State Key Laboratory of Biogeology and Environmental Geology, China University of Geosciences, Wuhan 430074, China
27 shared publicationsXing Liu
State Key Laboratory of Geomicrobiology and Environmental Changes, China University of Geosciences, Wuhan, Hubei 430074, China
17 shared publicationsChun Yang
State Key Laboratory of Biogeology and Environmental Geology, China University of Geosciences, Wuhan 430074, China
14 shared publicationsDong He
State Key Laboratory of Biogeology and Environmental Geology, China University of Geosciences, Wuhan, 430074, China
14 shared publications- Junhang Dong
State Key Laboratory of Geomicrobiology and Environmental Changes, China University of Geosciences, Wuhan, Hubei 430074, China
14 shared publications
Latest Publications
- 2 September 2026
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 41  (9) , 3266-3274
Reagent-free atomic fluorescence spectrometry determination of trace cadmium enabled by micro-ultrasonic nebulization
Reagent-free micro-ultrasonic nebulization enables efficient aerosol introduction for rapid cadmium determination by atomic fluorescence spectrometry.
- 2 September 2026
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 41  (9) , 3266-3274
Reagent-free atomic fluorescence spectrometry determination of trace cadmium enabled by micro-ultrasonic nebulization
Reagent-free micro-ultrasonic nebulization enables efficient aerosol introduction for rapid cadmium determination by atomic fluorescence spectrometry.
- 18 August 2026
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 98  (36) , 26603-26613
Augmenting ICP-OES Sensitivity for Trace Element Analysis in Crude Oil via High-Efficiency Micro-Ultrasonic Nebulization
Sensitive trace elements analysis in crude oil via inductively coupled plasma optical emission spectrometry (ICP-OES) is highly desirable for the petroleum industry. However, the conventional pneumatic nebulization (PN) sample introduction system suffers from extremely low nebulization efficiency (<5%), leading to inadequate sensitivity. Herein, a novel high-efficiency (∼85%) micro-ultrasonic nebulization (MUN) designed for ICP-OES was successfully developed. Under optimized conditions, MUN-ICP-OES achieved up to 17-fold sensitivity enhancements across 12 tested elements compared to conventional PN-ICP-OES, despite a 10-fold reduction in sample consumption. Notably, the MUN system permits independent adjustment of the carrier gas, lowering its flow rate extends aerosol residence time in the plasma, further boosting sensitivity without compromising nebulization efficiency. Furthermore, the MUN-ICP-OES demonstrated robust resistance to organic matrix interference and excellent long-term stability, achieving a relative standard deviation of 0.2% over 30 consecutive measurements using Ga as an internal standard. Compared to PN-ICP-OES, the limits of detection for the 12 elements in crude oils improved by 1–2 orders of magnitude. The accuracy of the proposed method was validated using a certified reference material, and results for actual crude oils showed excellent agreement with ICP–MS. Overall, this study validates that employing MUN as a high-efficiency sample introduction system significantly elevates the analytical capabilities of ICP-OES, thereby facilitating the precise quantification of trace elements in complex energy and environmental matrices.
- 18 August 2026
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 98  (36) , 26603-26613
Augmenting ICP-OES Sensitivity for Trace Element Analysis in Crude Oil via High-Efficiency Micro-Ultrasonic Nebulization
Sensitive trace elements analysis in crude oil via inductively coupled plasma optical emission spectrometry (ICP-OES) is highly desirable for the petroleum industry. However, the conventional pneumatic nebulization (PN) sample introduction system suffers from extremely low nebulization efficiency (<5%), leading to inadequate sensitivity. Herein, a novel high-efficiency (∼85%) micro-ultrasonic nebulization (MUN) designed for ICP-OES was successfully developed. Under optimized conditions, MUN-ICP-OES achieved up to 17-fold sensitivity enhancements across 12 tested elements compared to conventional PN-ICP-OES, despite a 10-fold reduction in sample consumption. Notably, the MUN system permits independent adjustment of the carrier gas, lowering its flow rate extends aerosol residence time in the plasma, further boosting sensitivity without compromising nebulization efficiency. Furthermore, the MUN-ICP-OES demonstrated robust resistance to organic matrix interference and excellent long-term stability, achieving a relative standard deviation of 0.2% over 30 consecutive measurements using Ga as an internal standard. Compared to PN-ICP-OES, the limits of detection for the 12 elements in crude oils improved by 1–2 orders of magnitude. The accuracy of the proposed method was validated using a certified reference material, and results for actual crude oils showed excellent agreement with ICP–MS. Overall, this study validates that employing MUN as a high-efficiency sample introduction system significantly elevates the analytical capabilities of ICP-OES, thereby facilitating the precise quantification of trace elements in complex energy and environmental matrices.
- 10 July 2026
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 98  (28) , 20768-20776
Development of a Hydraulic-Drive Automatic Column Chromatography System for High Precision Isotope Analysis
This study presents a high-throughput automated open-column chromatography system designed for high-precision isotope analysis based on a hydraulic remote-drive mechanism. The system operates by using pressurized fluid to indirectly control eluent delivery, resulting in a completely metal-free separation unit that fully isolates metal components (pump, sensor, and valve) from corrosive acid solutions and vapors. This design effectively eliminates the corrosion and contamination risks inherent to conventional systems. Coupled with pressure sensing and mass flow feedback control, the hydraulic drive enables multichannel parallel elution (currently 8 channels) with high accuracy (error <3%) and excellent interchannel consistency (variation <0.5%). Constructed primarily from low-cost polymers, the system offers an economical and scalable platform for automated sample preparation. Validation using Cd and Cu isotope separation protocols demonstrated high recoveries (Cd: 97.5 ± 1.6%; Cu: 98.3 ± 1.4%) and low procedural blanks (Cd: 0.17 ng; Cu: 0.72 ng). Analysis of geological reference materials (e.g., BHVO-2, BCR-2, NOD-P-1) yielded isotopic ratios consistent with published values, confirming method reliability. Overall, the system provides a scalable, cost-effective, and metal-free platform for high-throughput separations required for high-precision isotope analysis.
- 10 July 2026
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 98  (28) , 20768-20776
Development of a Hydraulic-Drive Automatic Column Chromatography System for High Precision Isotope Analysis
This study presents a high-throughput automated open-column chromatography system designed for high-precision isotope analysis based on a hydraulic remote-drive mechanism. The system operates by using pressurized fluid to indirectly control eluent delivery, resulting in a completely metal-free separation unit that fully isolates metal components (pump, sensor, and valve) from corrosive acid solutions and vapors. This design effectively eliminates the corrosion and contamination risks inherent to conventional systems. Coupled with pressure sensing and mass flow feedback control, the hydraulic drive enables multichannel parallel elution (currently 8 channels) with high accuracy (error <3%) and excellent interchannel consistency (variation <0.5%). Constructed primarily from low-cost polymers, the system offers an economical and scalable platform for automated sample preparation. Validation using Cd and Cu isotope separation protocols demonstrated high recoveries (Cd: 97.5 ± 1.6%; Cu: 98.3 ± 1.4%) and low procedural blanks (Cd: 0.17 ng; Cu: 0.72 ng). Analysis of geological reference materials (e.g., BHVO-2, BCR-2, NOD-P-1) yielded isotopic ratios consistent with published values, confirming method reliability. Overall, the system provides a scalable, cost-effective, and metal-free platform for high-throughput separations required for high-precision isotope analysis.
- Open Access
- 29 June 2026
- Published by Springer Nature in Nature Communications
- Vol. 17  (1)
Extreme mass-independent fractionation of mercury isotopes driven by atmospheric plasma-induced chemical process
Mass-independent fractionation (MIF) of mercury (Hg) provides a powerful tracer for reconstructing Hg cycling in the Earth system. Although generally attributed to photochemistry, many natural isotope signatures remain inconsistent with the established mechanisms. Here, we present experimental evidence that atmospheric plasma-induced reduction produces odd Hg-MIF with magnitudes and patterns distinct from photochemical processes. Plasma reactions yielded far larger odd-MIF signatures than photoreduction, with Δ199Hg spanning -78‰ to +28‰, the most negative Hg-MIF across all Hg-reduction experiments. The sign of Hg-MIF reverses with solution pH, yielding strongly negative Hg-MIF at pH ≥ 3.0 but positive Hg-MIF at pH ≤ 2.0. This reversal arises from competition between plasma-generated species, where solvated electrons drive negative magnetic isotope effects (MIE) at higher pH, while hydrogen radicals produce positive MIE at low pH. These findings reveal plasma chemistry as a fundamental but previously overlooked driver of Hg isotope fractionation. Given the ubiquity of natural plasmas such as lightning and aurora, plasma processes need to be integrated into models of Hg cycling in Earth's atmosphere and surface environments.
- 29 June 2026
- Published by Springer Nature in Nature Communications
- Vol. 17  (1)
Open AccessExtreme mass-independent fractionation of mercury isotopes driven by atmospheric plasma-induced chemical process
Mass-independent fractionation (MIF) of mercury (Hg) provides a powerful tracer for reconstructing Hg cycling in the Earth system. Although generally attributed to photochemistry, many natural isotope signatures remain inconsistent with the established mechanisms. Here, we present experimental evidence that atmospheric plasma-induced reduction produces odd Hg-MIF with magnitudes and patterns distinct from photochemical processes. Plasma reactions yielded far larger odd-MIF signatures than photoreduction, with Δ199Hg spanning -78‰ to +28‰, the most negative Hg-MIF across all Hg-reduction experiments. The sign of Hg-MIF reverses with solution pH, yielding strongly negative Hg-MIF at pH ≥ 3.0 but positive Hg-MIF at pH ≤ 2.0. This reversal arises from competition between plasma-generated species, where solvated electrons drive negative magnetic isotope effects (MIE) at higher pH, while hydrogen radicals produce positive MIE at low pH. These findings reveal plasma chemistry as a fundamental but previously overlooked driver of Hg isotope fractionation. Given the ubiquity of natural plasmas such as lightning and aurora, plasma processes need to be integrated into models of Hg cycling in Earth's atmosphere and surface environments.
- Open Access
- 18 April 2026
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 41  (5) , 1908-1916
Sensitive determination of biologically important transition metals by ICP-QMS using micro-ultrasonic single droplet nebulization
A MUSDN-ICP-QMS method allows direct analysis of trace elements in undigested serum using only 1–5 µL per test. It exhibits high TDS/organic tolerance and one order of magnitude higher sensitivity than conventional PN-ICP-QMS.
- 18 April 2026
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 41  (5) , 1908-1916
Open AccessSensitive determination of biologically important transition metals by ICP-QMS using micro-ultrasonic single droplet nebulization
A MUSDN-ICP-QMS method allows direct analysis of trace elements in undigested serum using only 1–5 µL per test. It exhibits high TDS/organic tolerance and one order of magnitude higher sensitivity than conventional PN-ICP-QMS.
- 10 April 2026
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 41  (5) , 1641-1650
Preparation of rutile reference materials for in situ elemental and Hf–Ti isotopic microanalysis using spark plasma sintering
The use of ultrafine powders combined with SPS techniques is proposed as an ideal protocol for preparing rutile reference materials for in situ elemental and isotopic analysis.
- 10 April 2026
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 41  (5) , 1641-1650
Preparation of rutile reference materials for in situ elemental and Hf–Ti isotopic microanalysis using spark plasma sintering
The use of ultrafine powders combined with SPS techniques is proposed as an ideal protocol for preparing rutile reference materials for in situ elemental and isotopic analysis.
- Top Cited Papers
- 3 April 2026
- Published by American Association for the Advancement of Science (AAAS) in Science Immunology
- Vol. 11  (118) , eaec2573
Copper supports regulatory T cell energetic state to sustain peripheral immune tolerance
Fine-tuning of energy metabolism is essential for the survival and suppressive function of regulatory T cells (T reg cells). Here, we show that T reg cells with a high energetic state display enhanced functional capacity. Using a screen of mitochondrial inhibitors, we identified copper chelators and ionophores as modulators of T reg cell energetic state. T cell receptor (TCR) stimulation in vitro and human autoimmune conditions increased the labile copper pool in T reg cells. In murine T reg cells, we characterized Slc31a1 as a major copper transporter that supports oxidative phosphorylation, sustains nicotinamide adenine dinucleotide/reduced NAD + (NAD + /NADH) homeostasis, and promotes histone acetylation at loci encoding core T reg cell functional molecules. These mechanisms collectively ensured energy production and T reg cell functionality, which were indispensable for peripheral immune tolerance but could be rescued by the copper ionophore elesclomol. Together, our findings identify copper metabolism as a critical regulator of T reg cell functionality and suggest potential therapeutic avenues for autoimmune diseases.
- 3 April 2026
- Published by American Association for the Advancement of Science (AAAS) in Science Immunology
- Vol. 11  (118) , eaec2573
Top Cited PapersCopper supports regulatory T cell energetic state to sustain peripheral immune tolerance
Fine-tuning of energy metabolism is essential for the survival and suppressive function of regulatory T cells (T reg cells). Here, we show that T reg cells with a high energetic state display enhanced functional capacity. Using a screen of mitochondrial inhibitors, we identified copper chelators and ionophores as modulators of T reg cell energetic state. T cell receptor (TCR) stimulation in vitro and human autoimmune conditions increased the labile copper pool in T reg cells. In murine T reg cells, we characterized Slc31a1 as a major copper transporter that supports oxidative phosphorylation, sustains nicotinamide adenine dinucleotide/reduced NAD + (NAD + /NADH) homeostasis, and promotes histone acetylation at loci encoding core T reg cell functional molecules. These mechanisms collectively ensured energy production and T reg cell functionality, which were indispensable for peripheral immune tolerance but could be rescued by the copper ionophore elesclomol. Together, our findings identify copper metabolism as a critical regulator of T reg cell functionality and suggest potential therapeutic avenues for autoimmune diseases.
- Open Access
- 25 March 2026
- Published by Royal Society of Chemistry (RSC) in Environmental Science: Nano
- Vol. 13  (5) , 2386-2395
Facet-dependent photo-Fenton degradation of p -arsanilic acid and arsenic redistribution on hematite
The photo-degradation of p -ASA on hematite HNC and HNP was investigated. Results demonstrated that the catalytic function of hematite is facet-dependent, governing both the transformation of pollutants and their associated environmental risks.
- 25 March 2026
- Published by Royal Society of Chemistry (RSC) in Environmental Science: Nano
- Vol. 13  (5) , 2386-2395
Open AccessFacet-dependent photo-Fenton degradation of p -arsanilic acid and arsenic redistribution on hematite
The photo-degradation of p -ASA on hematite HNC and HNP was investigated. Results demonstrated that the catalytic function of hematite is facet-dependent, governing both the transformation of pollutants and their associated environmental risks.
- Open Access
- 21 January 2026
- Published by OAE Publishing Inc. in Element
- Vol. 1  (1)
Lithium: from mood stabilizer to pivotal regulator of health - recent advances in lithium-based biomedicine
Highlights 1. Lithium isotopic enable psychiatric differentiation and reveal dysregulated Mg metabolism in pathological states. 2. Lithium broadens therapeutic horizons by mitigating Alzheimer's pathogenesis, reversing pulmonary fibrosis, and augmenting antitumor immunity. 3. Excessive lithium exposure triggers reproductive toxicity by inducing accumulation-dependent cuproptosis in placental trophoblasts. 4. As a multi-level regulator, lithium orchestrates neuro-immune-microbial systems by stabilizing essential trace element homeostasis (Mg, Fe, Cu). L Check for updates
- 21 January 2026
- Published by OAE Publishing Inc. in Element
- Vol. 1  (1)
Open AccessLithium: from mood stabilizer to pivotal regulator of health - recent advances in lithium-based biomedicine
Highlights 1. Lithium isotopic enable psychiatric differentiation and reveal dysregulated Mg metabolism in pathological states. 2. Lithium broadens therapeutic horizons by mitigating Alzheimer's pathogenesis, reversing pulmonary fibrosis, and augmenting antitumor immunity. 3. Excessive lithium exposure triggers reproductive toxicity by inducing accumulation-dependent cuproptosis in placental trophoblasts. 4. As a multi-level regulator, lithium orchestrates neuro-immune-microbial systems by stabilizing essential trace element homeostasis (Mg, Fe, Cu). L Check for updates
- Open Access
- 7 October 2025
- Published by Springer Nature in Translational Psychiatry
- Vol. 15  (1) , 1-10
Natural lithium isotope variations in serum after lithium administration as a novel biomarker for differentiating schizophrenia and bipolar disorder
Accurate differentiation of schizophrenia (SZ) and bipolar disorder (BD) is crucial for effective clinical management. However, current diagnostic methods, which rely heavily on subjective assessments, are prone to high rates of misdiagnosis. This study pioneers the investigation of natural variations in lithium (Li) isotopes as potential biomarkers for differentiating BD and SZ. We identified significant and distinct variations in the isotopic compositions of Li in serum (δ7Liserum) of SZ patients relative to BD patients and health controls. Furthermore, we established a machine learning model that achieved a remarkable 100% accuracy in distinguishing between SZ and BD patients based on δ7Liserum fingerprints and concentrations of biologically relevant elements (Ca, Mg, Zn, and Se) in serum. Our research reveals that δ7Liserum is notably lighter in both BD and SZ patients (approximately 11 and 5‰, respectively) compared to that of the ingested Li drugs and decreases over time, primarily due to renal excretion. Additionally, in induced pluripotent stem cell (iPSC) models, we observed substantially heavier intracellular δ7Li values (up to 10‰) compared to the culture medium (0‰), likely originating from specific intracellular biochemical processes associated with competitions between Li+ and Mg2+. These differences in intracellular processes may significantly contribute to the observed distinctions in δ7Liserum values between BD and SZ patients. Our findings demonstrate that the δ7Liserum fingerprints in homeostasis provide valuable insights into the differentiate biomarker and pathological mechanism research of mental diseases.
- 7 October 2025
- Published by Springer Nature in Translational Psychiatry
- Vol. 15  (1) , 1-10
Open AccessNatural lithium isotope variations in serum after lithium administration as a novel biomarker for differentiating schizophrenia and bipolar disorder
Accurate differentiation of schizophrenia (SZ) and bipolar disorder (BD) is crucial for effective clinical management. However, current diagnostic methods, which rely heavily on subjective assessments, are prone to high rates of misdiagnosis. This study pioneers the investigation of natural variations in lithium (Li) isotopes as potential biomarkers for differentiating BD and SZ. We identified significant and distinct variations in the isotopic compositions of Li in serum (δ7Liserum) of SZ patients relative to BD patients and health controls. Furthermore, we established a machine learning model that achieved a remarkable 100% accuracy in distinguishing between SZ and BD patients based on δ7Liserum fingerprints and concentrations of biologically relevant elements (Ca, Mg, Zn, and Se) in serum. Our research reveals that δ7Liserum is notably lighter in both BD and SZ patients (approximately 11 and 5‰, respectively) compared to that of the ingested Li drugs and decreases over time, primarily due to renal excretion. Additionally, in induced pluripotent stem cell (iPSC) models, we observed substantially heavier intracellular δ7Li values (up to 10‰) compared to the culture medium (0‰), likely originating from specific intracellular biochemical processes associated with competitions between Li+ and Mg2+. These differences in intracellular processes may significantly contribute to the observed distinctions in δ7Liserum values between BD and SZ patients. Our findings demonstrate that the δ7Liserum fingerprints in homeostasis provide valuable insights into the differentiate biomarker and pathological mechanism research of mental diseases.