Jerome Mertz
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Jerome Mertz has a total of 232 co-authors. Here are the top co-authors by number of shared publications:
- Sheng Xiao
Chan Zuckerberg Biohub, San Francisco, USA
13 shared publications - Timothy D. Weber
Department of Electrical Engineering and Computer Science and Research Laboratory of Electronics, Massachusetts Institute of Technology , Cambridge, MA
11 shared publications Kengyeh K. Chu
Boston University, Department of Biomedical Engineering, 44 Cummington Street, Boston, Massachusetts 02215, USA
9 shared publications- Bingying Zhao
Boston University
6 shared publications Daryl Lim
Boston University, Department of Biomedical Engineering, 44 Cummington Street, Boston, Massachusetts 02215, USA
6 shared publications- Michael Nicholas Economo
Department of Biomedical Engineering, Center for Systems Neuroscience, Neurophotonics Center, Boston University
6 shared publications
Latest Publications
- Open Access
- 20 October 2026
- Published by Springer Nature in Nature Communications
Three-photon population imaging of subcortical brain regions
- 20 October 2026
- Published by Springer Nature in Nature Communications
Open AccessThree-photon population imaging of subcortical brain regions
- Open Access
- 6 October 2026
- Published by National Academy of Sciences in Proceedings of the National Academy of Sciences
- Vol. 123 (41)
Tailored speckle illumination microscopy with enhanced sectioning and image quality
Optical speckle patterns have been widely used for illumination in computational imaging, optical sectioning microscopy, and superresolution imaging. However, commonly used speckles satisfy Rayleigh statistics, which are not ideal for diverse imaging applications. Here we tailor three-dimensional speckle intensity statistics for dynamic speckle illumination microscopy based on linear fluorescence. Optical sectioning is enhanced by axially varying speckle contrast, and image reconstruction noise is minimized with in-focus speckles of binary intensities. The customized speckle statistics are shown to tolerate sample-induced aberration and scattering. We apply tailored speckle illumination to mouse brain vascular imaging and demonstrate much improved image quality than optical-sectioning structured illumination. These results establish customization of speckle intensity statistics as a promising strategy for robust, high-throughput fluorescence imaging in thick, scattering biological specimens.
- 6 October 2026
- Published by National Academy of Sciences in Proceedings of the National Academy of Sciences
- Vol. 123 (41)
Open AccessTailored speckle illumination microscopy with enhanced sectioning and image quality
Optical speckle patterns have been widely used for illumination in computational imaging, optical sectioning microscopy, and superresolution imaging. However, commonly used speckles satisfy Rayleigh statistics, which are not ideal for diverse imaging applications. Here we tailor three-dimensional speckle intensity statistics for dynamic speckle illumination microscopy based on linear fluorescence. Optical sectioning is enhanced by axially varying speckle contrast, and image reconstruction noise is minimized with in-focus speckles of binary intensities. The customized speckle statistics are shown to tolerate sample-induced aberration and scattering. We apply tailored speckle illumination to mouse brain vascular imaging and demonstrate much improved image quality than optical-sectioning structured illumination. These results establish customization of speckle intensity statistics as a promising strategy for robust, high-throughput fluorescence imaging in thick, scattering biological specimens.
- 2 October 2026
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 12 (40)
A computational super-resolution framework for multidimensional fluorescence imaging
Fully capturing the heterogeneity of biological processes remains a central challenge, as conventional confocal microscopy typically surveys large ensembles of molecules within a small volume. The development of super-resolution imaging enables the capture of images with exceptional detail. When super-resolution is combined with functional imaging, such as fluorescence lifetime and spectral imaging, it provides better separation of image constituents and sensing of environmental properties at the nanoscale. These multidimensional imaging approaches often acquire functional and fluorescence images separately and then merge the resulting datasets, a post hoc approach that risks dynamic range mismatches and the loss of subtle molecular signals. Here, we introduce a computational super-resolution framework based on the deblurring by pixel reassignment (DPR) algorithm, which processes multidimensional data as high-dimensional tensors, integrating spatial axes with fluorescence lifetime or spectral information into a single dataset. Using DPR, high-resolution details can be extracted from conventional fluorescence microscopy images, even from a single capture. We show that this approach enhances the spatial resolution of multidimensional datasets without compromising quantitative fidelity. As a proof of concept, we demonstrate super-resolution multimodal imaging (intensity, lifetime, and spectra), revealing fine-scale details while preserving signals from rare or low-intensity molecular events. This accessible yet powerful method paves the way for quantitative, single-molecule–level insights into complex biological systems.
- 2 October 2026
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 12 (40)
A computational super-resolution framework for multidimensional fluorescence imaging
Fully capturing the heterogeneity of biological processes remains a central challenge, as conventional confocal microscopy typically surveys large ensembles of molecules within a small volume. The development of super-resolution imaging enables the capture of images with exceptional detail. When super-resolution is combined with functional imaging, such as fluorescence lifetime and spectral imaging, it provides better separation of image constituents and sensing of environmental properties at the nanoscale. These multidimensional imaging approaches often acquire functional and fluorescence images separately and then merge the resulting datasets, a post hoc approach that risks dynamic range mismatches and the loss of subtle molecular signals. Here, we introduce a computational super-resolution framework based on the deblurring by pixel reassignment (DPR) algorithm, which processes multidimensional data as high-dimensional tensors, integrating spatial axes with fluorescence lifetime or spectral information into a single dataset. Using DPR, high-resolution details can be extracted from conventional fluorescence microscopy images, even from a single capture. We show that this approach enhances the spatial resolution of multidimensional datasets without compromising quantitative fidelity. As a proof of concept, we demonstrate super-resolution multimodal imaging (intensity, lifetime, and spectra), revealing fine-scale details while preserving signals from rare or low-intensity molecular events. This accessible yet powerful method paves the way for quantitative, single-molecule–level insights into complex biological systems.
- 4 August 2026
- Published by Optica Publishing Group in Optics Express
- Vol. 34 (16) , 29928
Versatile 3D space-variant deconvolution with measurement-free point spread function models
Deconvolution is the most widely used aberration correction technique in microscopy, however most techniques assume that the aberrations are the same for each point in the image, which is rarely true. Methods for tracking spatially varying aberrations require burdensome calibration or computation, or require symmetries in the aberration patterns. Here, we expand on existing modal deconvolution methods and demonstrate 3D fluorescence deconvolution in imaging systems that exhibit no simple symmetry by utilizing measurement-free point spread function models. Our method is based on a space-variant generalization of Richardson-Lucy deconvolution that makes use of point spread functions derived entirely by ray-tracing based on the optical system design. This enables a hybrid combination of physics-based modal deconvolution and simulation-based PSF modeling. Importantly, it obviates any requirement for guide stars or measurements for PSF calibration. We validate the performance of our method by applying it to snapshot multiplane imaging of both bead samples and biological specimens, and show that modal decomposition is a practical solution for deconvolving spatially varying aberrations that do not display clear symmetries.
- 4 August 2026
- Published by Optica Publishing Group in Optics Express
- Vol. 34 (16) , 29928
Versatile 3D space-variant deconvolution with measurement-free point spread function models
Deconvolution is the most widely used aberration correction technique in microscopy, however most techniques assume that the aberrations are the same for each point in the image, which is rarely true. Methods for tracking spatially varying aberrations require burdensome calibration or computation, or require symmetries in the aberration patterns. Here, we expand on existing modal deconvolution methods and demonstrate 3D fluorescence deconvolution in imaging systems that exhibit no simple symmetry by utilizing measurement-free point spread function models. Our method is based on a space-variant generalization of Richardson-Lucy deconvolution that makes use of point spread functions derived entirely by ray-tracing based on the optical system design. This enables a hybrid combination of physics-based modal deconvolution and simulation-based PSF modeling. Importantly, it obviates any requirement for guide stars or measurements for PSF calibration. We validate the performance of our method by applying it to snapshot multiplane imaging of both bead samples and biological specimens, and show that modal decomposition is a practical solution for deconvolving spatially varying aberrations that do not display clear symmetries.
- 11 March 2026
- Published by Optica Publishing Group in Optics Express
- Vol. 34 (6) , 9871
Widefield pump-probe microscopy with coherent background subtraction by angle-compensated temporal shearing
Pump-probe microscopy enables label-free imaging of structural and chemical features of samples. However, signals in pump-probe microscopy are typically small and often must be measured in the presence of large backgrounds. As a result, achieving measurements with a high signal-to-noise ratio is challenging, particularly when using sensors that are easily saturated, such as CMOS cameras. We present a method for enhancing signal-to-noise ratio while avoiding detector saturation. In this approach, temporally separated (sheared) reference and probe pulses transmit through a sample before and after the arrival of a pump pulse. The probe and reference pulses are then temporally recombined with opposing phases and nearly matched amplitudes, resulting in interferometric background subtraction. This recombining operation is performed by a novel common-path interferometer. Unlike previous techniques for temporal shearing, this interferometer demonstrates negligible phase and group delay dispersion with angle of incidence, allowing convenient widefield imaging. To our knowledge, this is the first common-path interferometer with such a property. We demonstrate the technique by measuring transient absorption signals in gold nanorod films with a signal-to-background ratio enhanced by over 100% and a signal-to-noise ratio enhanced by about 70%.
- 11 March 2026
- Published by Optica Publishing Group in Optics Express
- Vol. 34 (6) , 9871
Widefield pump-probe microscopy with coherent background subtraction by angle-compensated temporal shearing
Pump-probe microscopy enables label-free imaging of structural and chemical features of samples. However, signals in pump-probe microscopy are typically small and often must be measured in the presence of large backgrounds. As a result, achieving measurements with a high signal-to-noise ratio is challenging, particularly when using sensors that are easily saturated, such as CMOS cameras. We present a method for enhancing signal-to-noise ratio while avoiding detector saturation. In this approach, temporally separated (sheared) reference and probe pulses transmit through a sample before and after the arrival of a pump pulse. The probe and reference pulses are then temporally recombined with opposing phases and nearly matched amplitudes, resulting in interferometric background subtraction. This recombining operation is performed by a novel common-path interferometer. Unlike previous techniques for temporal shearing, this interferometer demonstrates negligible phase and group delay dispersion with angle of incidence, allowing convenient widefield imaging. To our knowledge, this is the first common-path interferometer with such a property. We demonstrate the technique by measuring transient absorption signals in gold nanorod films with a signal-to-background ratio enhanced by over 100% and a signal-to-noise ratio enhanced by about 70%.
- Open Access
Subthreshold membrane depolarization powerfully engages intracellular calcium dynamics in the brain
Membrane voltage (Vm) regulates spike timing and intracellular signaling. While Vm is extensively modulated by behavior, it is unclear how subthreshold Vm dynamics engage intracellular signaling in the awake mammalian brain. We developed a bicistronic viral vector to express genetically encoded and color compatible voltage and calcium (Ca 2+ ) indicators in the same neuron, and simultaneously recorded cellular Vm and Ca 2+ dynamics in awake mice. We report that prolonged subthreshold Vm depolarization is closely accompanied by prominent large amplitude Ca 2+ elevation, whereas isolated spikes are coupled with weak Ca 2+ rise. Additionally, individual spikes differentially engage intracellular Ca 2+ dynamics depending on post-spiking Vm depolarization, consistent with a prominent role of slow Vm depolarization in regulating cellular signaling. While brief intracranial electrical stimulation consistently leads to Vm depolarization and Ca 2+ increase, longer stimulation disrupts Vm and Ca 2+ coupling, highlighting a tightly regulated cellular mechanism that relays slow Vm depolarization to intracellular signaling. One-Sentence Summary: Prolonged membrane depolarization engages cytosolic calcium.
Open AccessSubthreshold membrane depolarization powerfully engages intracellular calcium dynamics in the brain
Membrane voltage (Vm) regulates spike timing and intracellular signaling. While Vm is extensively modulated by behavior, it is unclear how subthreshold Vm dynamics engage intracellular signaling in the awake mammalian brain. We developed a bicistronic viral vector to express genetically encoded and color compatible voltage and calcium (Ca 2+ ) indicators in the same neuron, and simultaneously recorded cellular Vm and Ca 2+ dynamics in awake mice. We report that prolonged subthreshold Vm depolarization is closely accompanied by prominent large amplitude Ca 2+ elevation, whereas isolated spikes are coupled with weak Ca 2+ rise. Additionally, individual spikes differentially engage intracellular Ca 2+ dynamics depending on post-spiking Vm depolarization, consistent with a prominent role of slow Vm depolarization in regulating cellular signaling. While brief intracranial electrical stimulation consistently leads to Vm depolarization and Ca 2+ increase, longer stimulation disrupts Vm and Ca 2+ coupling, highlighting a tightly regulated cellular mechanism that relays slow Vm depolarization to intracellular signaling. One-Sentence Summary: Prolonged membrane depolarization engages cytosolic calcium.
- Open Access
- 20 November 2025
- Published by Optica Publishing Group in Optica
- Vol. 12 (12) , 1865
Back-illumination interference tomography for imaging weak scattering in thick tissues
Biological tissues are composed of discrete compartments of biochemical media that often exhibit subtle differences in refractive index. Light propagating through these compartments partially diffracts in a forward direction with a π /2 phase shift. We introduce a microscopy technique to image this scattering signal in thick tissues, called back-illumination interference tomography (BIT). An incoherent source is demagnified and imaged past the focal plane of a high-numerical aperture objective lens, producing a small, semicoherent source of backscattered light. This backscattered light undergoes a phase inversion over the narrow depth of field of the microscope, providing interference contrast to weakly scattering objects at the focal plane. BIT offers a different source of contrast to conventional illumination and oblique back-illumination microscopy. Compared to these techniques, we show that BIT improves contrast to blood cells in vitro in microfluidic chambers and in vivo in a human capillary. Finally, we apply BIT to unstained, unlabeled bulk human tissue ex vivo and compare side-by-side to adjacent frozen sections stained with hematoxylin and eosin. These results demonstrate the potential of BIT to provide high-resolution, high-speed, 3D imaging of unprocessed biological tissues.
- 20 November 2025
- Published by Optica Publishing Group in Optica
- Vol. 12 (12) , 1865
Open AccessBack-illumination interference tomography for imaging weak scattering in thick tissues
Biological tissues are composed of discrete compartments of biochemical media that often exhibit subtle differences in refractive index. Light propagating through these compartments partially diffracts in a forward direction with a π /2 phase shift. We introduce a microscopy technique to image this scattering signal in thick tissues, called back-illumination interference tomography (BIT). An incoherent source is demagnified and imaged past the focal plane of a high-numerical aperture objective lens, producing a small, semicoherent source of backscattered light. This backscattered light undergoes a phase inversion over the narrow depth of field of the microscope, providing interference contrast to weakly scattering objects at the focal plane. BIT offers a different source of contrast to conventional illumination and oblique back-illumination microscopy. Compared to these techniques, we show that BIT improves contrast to blood cells in vitro in microfluidic chambers and in vivo in a human capillary. Finally, we apply BIT to unstained, unlabeled bulk human tissue ex vivo and compare side-by-side to adjacent frozen sections stained with hematoxylin and eosin. These results demonstrate the potential of BIT to provide high-resolution, high-speed, 3D imaging of unprocessed biological tissues.
- Open Access
Relative phase of membrane potential theta oscillations between individual hippocampal neurons code space
The timing of spikes dictates a neuron’s impact on downstream circuits and behavior, and spike timing is determined by the membrane potential (Vm). However, due to technical challenges, it has been impossible to analyze the relative timing of Vm dynamics between neurons during behavior. Using large scale membrane voltage imaging, we simultaneously recorded Vm from many individual hippocampal neurons in animals engaged in a virtual spatial task. We found that relative phase of Vm theta oscillations across neurons exhibit gradual or discrete shifts depending on spatial position. This finding extends beyond previous studies showing Vm dynamics in single neurons or spiking activity in multiple neurons, revealing previously unknown evidence for consistent coding of space by spike-independent relative phase of Vm theta dynamics between neurons.
Open AccessRelative phase of membrane potential theta oscillations between individual hippocampal neurons code space
The timing of spikes dictates a neuron’s impact on downstream circuits and behavior, and spike timing is determined by the membrane potential (Vm). However, due to technical challenges, it has been impossible to analyze the relative timing of Vm dynamics between neurons during behavior. Using large scale membrane voltage imaging, we simultaneously recorded Vm from many individual hippocampal neurons in animals engaged in a virtual spatial task. We found that relative phase of Vm theta oscillations across neurons exhibit gradual or discrete shifts depending on spatial position. This finding extends beyond previous studies showing Vm dynamics in single neurons or spiking activity in multiple neurons, revealing previously unknown evidence for consistent coding of space by spike-independent relative phase of Vm theta dynamics between neurons.
- Open Access
Superresolution imaging of live samples by centroid reassignment microscopy
Superresolution imaging has become one of the most important recent advances in microscopy development. However, most superresolution methods are ill-adapted for live-sample imaging because they are unacceptably slow, susceptible to artifacts, or require the use of specialized fluorophores and labeling protocols. We introduce a superresolution method called centroid reassignment microscopy (CRM) that overcomes these limitations. CRM is a simple variation on confocal microscopy wherein the single-element detector and small pinhole are replaced by a centroid detector and larger pinhole. Superresolution is obtained by reassigning the centroid location of the detected fluorescence as a function of the scanning excitation focus location. Our method bears resemblance to the method of image scanning microscopy, which involves the use of an array detector, with the advantage that CRM provides improved resolution for the same number of detected photons while being simpler to implement. CRM is light-efficient, fast (single frame), robust to defocus aberrations, and requires no changes whatsoever in standard fluorescence imaging protocols, making it uniquely attractive for superresolution imaging of live, dynamic samples.
Open AccessSuperresolution imaging of live samples by centroid reassignment microscopy
Superresolution imaging has become one of the most important recent advances in microscopy development. However, most superresolution methods are ill-adapted for live-sample imaging because they are unacceptably slow, susceptible to artifacts, or require the use of specialized fluorophores and labeling protocols. We introduce a superresolution method called centroid reassignment microscopy (CRM) that overcomes these limitations. CRM is a simple variation on confocal microscopy wherein the single-element detector and small pinhole are replaced by a centroid detector and larger pinhole. Superresolution is obtained by reassigning the centroid location of the detected fluorescence as a function of the scanning excitation focus location. Our method bears resemblance to the method of image scanning microscopy, which involves the use of an array detector, with the advantage that CRM provides improved resolution for the same number of detected photons while being simpler to implement. CRM is light-efficient, fast (single frame), robust to defocus aberrations, and requires no changes whatsoever in standard fluorescence imaging protocols, making it uniquely attractive for superresolution imaging of live, dynamic samples.
- Open Access
- 2 July 2025
- Published by Springer Nature in Nature Communications
- Vol. 16 (1) , 1-15
Ultrasensitive in vivo infrared spectroscopic imaging via oblique photothermal microscopy
In vivo IR spectroscopy faces challenges due to poor sensitivity in reflection mode and low resolution at micrometer scale. To break this barrier, we report an oblique photothermal microscope (OPTM) to enable ultrasensitive IR spectroscopic imaging of live subjects at sub-micron resolution. Classic photothermal measurement captures only a small fraction of probe photons through an iris to extract the photothermal signal. Instead, OPTM uses a differential split detector placed on the sample surface to collect 500-fold more photons and suppress the laser noise by 12 fold via balanced detection. Leveraging its improved sensitivity, OPTM enables low-dose IR imaging of skin without photodamage. Depth-resolved in vivo OPTM imaging of metabolic markers beneath mouse and human skin is shown. Furthermore, we demonstrate in vivo OPTM tracking of topical drug contents within mouse and human skin. Collectively, OPTM presents a highly sensitive imaging platform for in vivo and in situ molecular analysis.
- 2 July 2025
- Published by Springer Nature in Nature Communications
- Vol. 16 (1) , 1-15
Open AccessUltrasensitive in vivo infrared spectroscopic imaging via oblique photothermal microscopy
In vivo IR spectroscopy faces challenges due to poor sensitivity in reflection mode and low resolution at micrometer scale. To break this barrier, we report an oblique photothermal microscope (OPTM) to enable ultrasensitive IR spectroscopic imaging of live subjects at sub-micron resolution. Classic photothermal measurement captures only a small fraction of probe photons through an iris to extract the photothermal signal. Instead, OPTM uses a differential split detector placed on the sample surface to collect 500-fold more photons and suppress the laser noise by 12 fold via balanced detection. Leveraging its improved sensitivity, OPTM enables low-dose IR imaging of skin without photodamage. Depth-resolved in vivo OPTM imaging of metabolic markers beneath mouse and human skin is shown. Furthermore, we demonstrate in vivo OPTM tracking of topical drug contents within mouse and human skin. Collectively, OPTM presents a highly sensitive imaging platform for in vivo and in situ molecular analysis.