Behrooz Fereidoonnezhad
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Behrooz Fereidoonnezhad has a total of 81 co-authors. Here are the top co-authors by number of shared publications:
- J. Patrick McGarry
National University of Ireland Galway
8 shared publications Patrick McGarry
Biomedical Engineering Department, National University of Ireland Galway, Galway, Ireland
8 shared publicationsRay McCarthy
Cerenovus Galway Neuro-Technology Centre, Johnson & Johnson, Galway, Ireland
4 shared publicationsAad van der Lugt
3 shared publications- Giulia Luraghi
Laboratory of Biological Structure Mechanics (LaBS), Department of Chemistry, Materials and Chemical Engineering "Giulio Natta", Politecnico di Milano, Milan, Italy
3 shared publications Kevin M. Moerman
3 shared publications
Latest Publications
- Open Access
A Continuum Fibre Network Model for the Anisotropic and Compressible Mechanics of Human Skin
We present a Continuum Fibre Network (CFN) formulation for modelling anisotropy, strain stiffening and volume change in fibrous soft tissues. The model combines a three-dimensional fibre orientation distribution, a tension-only fibre law and a separate phenomenological volumetric potential. We calibrated the model using published uniaxial tensile and volume-change data for excised human skin from separate studies. Changes in cross-sectional area affected the tensile stress estimates for models that predicted volume change. Simulations of indentation, shear and biaxial tension illustrate predictions of the calibrated formulation under additional loading conditions. The CFN formulation included a weak isotropic neo-Hookean ground matrix with a prescribed shear modulus of 0.1 MPa.
Open AccessA Continuum Fibre Network Model for the Anisotropic and Compressible Mechanics of Human Skin
We present a Continuum Fibre Network (CFN) formulation for modelling anisotropy, strain stiffening and volume change in fibrous soft tissues. The model combines a three-dimensional fibre orientation distribution, a tension-only fibre law and a separate phenomenological volumetric potential. We calibrated the model using published uniaxial tensile and volume-change data for excised human skin from separate studies. Changes in cross-sectional area affected the tensile stress estimates for models that predicted volume change. Simulations of indentation, shear and biaxial tension illustrate predictions of the calibrated formulation under additional loading conditions. The CFN formulation included a weak isotropic neo-Hookean ground matrix with a prescribed shear modulus of 0.1 MPa.
- Open Access
- 1 December 2025
- Published by IOP Publishing in Journal of Physics: Photonics
- Vol. 8 (1) , 015017
A multiscale framework for in silico thrombus generation and photoacoustic simulations
Thrombus composition and microstructure play a critical role in determining the treatment success for thrombus-related diseases such as ischemic stroke and deep vein thrombosis. However, no in vivo diagnostic method can fully capture thrombus microstructure yet, hindering personalized treatment. Photoacoustic imaging is uniquely positioned to provide information on thrombi composition as it relays optical absorption information from diffuse photons at acoustic propagation depths. Computational modeling enables systematic exploration of microstructural effects on imaging signals, offering insights into developing improved in vivo diagnostic techniques. However, no photoacoustic simulation platform can model microstructural features within centimeter-scale phantoms at reasonable computational cost. In this work, we present recursive iterative fibrin network emulation (REFINE), a topology-driven framework for generating in silico thrombi that replicate their key microstructural traits. Unlike existing methods, REFINE enables controlled, recursive optimization of thrombus topology, making it suitable for accurate photoacoustic modeling and potentially powerful for biomechanical analyses beyond this study. These digital thrombi are embedded into a multiscale photoacoustic simulation platform that bridges microscale acoustic modeling with macroscale thrombus geometries, enabling efficient and realistic simulation of photoacoustic signal responses. We created unique representation of thrombi microstructure for various compositions and porosities. Our simulation framework effectively links microstructural features to macroscale imaging outcomes, in agreement with previous empirical studies. Our simulation results demonstrate that thrombus microstructure significantly affects photoacoustic spectral responses and can be reliably modeled in silico. These findings highlight the potential of a multiscale photoacoustic simulation approach as a powerful tool for characterizing tissue microstructure and demonstrate the utility of our computational framework for in silico thrombi analysis and the development of diagnostic imaging strategies.
- 1 December 2025
- Published by IOP Publishing in Journal of Physics: Photonics
- Vol. 8 (1) , 015017
Open AccessA multiscale framework for in silico thrombus generation and photoacoustic simulations
Thrombus composition and microstructure play a critical role in determining the treatment success for thrombus-related diseases such as ischemic stroke and deep vein thrombosis. However, no in vivo diagnostic method can fully capture thrombus microstructure yet, hindering personalized treatment. Photoacoustic imaging is uniquely positioned to provide information on thrombi composition as it relays optical absorption information from diffuse photons at acoustic propagation depths. Computational modeling enables systematic exploration of microstructural effects on imaging signals, offering insights into developing improved in vivo diagnostic techniques. However, no photoacoustic simulation platform can model microstructural features within centimeter-scale phantoms at reasonable computational cost. In this work, we present recursive iterative fibrin network emulation (REFINE), a topology-driven framework for generating in silico thrombi that replicate their key microstructural traits. Unlike existing methods, REFINE enables controlled, recursive optimization of thrombus topology, making it suitable for accurate photoacoustic modeling and potentially powerful for biomechanical analyses beyond this study. These digital thrombi are embedded into a multiscale photoacoustic simulation platform that bridges microscale acoustic modeling with macroscale thrombus geometries, enabling efficient and realistic simulation of photoacoustic signal responses. We created unique representation of thrombi microstructure for various compositions and porosities. Our simulation framework effectively links microstructural features to macroscale imaging outcomes, in agreement with previous empirical studies. Our simulation results demonstrate that thrombus microstructure significantly affects photoacoustic spectral responses and can be reliably modeled in silico. These findings highlight the potential of a multiscale photoacoustic simulation approach as a powerful tool for characterizing tissue microstructure and demonstrate the utility of our computational framework for in silico thrombi analysis and the development of diagnostic imaging strategies.
- Open Access
A Multiscale Framework for In Silico Thrombus Generation and Photoacoustic Simulations
Thrombus microstructure plays a critical role in determining the treatment success for thrombus-related diseases such as stroke and deep vein thrombosis. However, no in vivo diagnostic method can fully capture thrombus microstructure yet. Photoacoustic imaging is uniquely positioned to provide information on thrombi composition as it relays optical absorption information from diffuse photons at acoustic propagation depths. Computational modeling enables systematic exploration of microstructural effects on imaging signals, offering insights into developing improved in vivo diagnostic techniques. However, no photoacoustic simulation platform can model microstructural features within centimeter-scale phantoms at reasonable computational cost. Here, we present REFINE, a topology-driven framework for generating in silico thrombi replicating its key replicating their key microstructural traits. REFINE enables controlled, recursive optimization of thrombus topology, making it suitable for accurate photoacoustic modeling and potentially powerful for biomechanical analyses. These digital thrombi are embedded into a multiscale photoacoustic simulation platform that bridges microscale acoustic modeling with macroscale thrombus geometries, enabling efficient and realistic simulation of photoacoustic signal responses. We created unique thrombi microstructure for various compositions and porosities. Our simulation framework effectively links microstructural features to macroscale imaging outcomes, in agreement with previous empirical studies. Our results demonstrate that thrombus microstructure significantly affects photoacoustic spectral responses and can be modeled in silico. These findings highlight that multiscale photoacoustic simulation is a powerful tool for characterizing tissue microstructure and that our framework enables in silico thrombi analysis and diagnostic imaging strategy development
Open AccessA Multiscale Framework for In Silico Thrombus Generation and Photoacoustic Simulations
Thrombus microstructure plays a critical role in determining the treatment success for thrombus-related diseases such as stroke and deep vein thrombosis. However, no in vivo diagnostic method can fully capture thrombus microstructure yet. Photoacoustic imaging is uniquely positioned to provide information on thrombi composition as it relays optical absorption information from diffuse photons at acoustic propagation depths. Computational modeling enables systematic exploration of microstructural effects on imaging signals, offering insights into developing improved in vivo diagnostic techniques. However, no photoacoustic simulation platform can model microstructural features within centimeter-scale phantoms at reasonable computational cost. Here, we present REFINE, a topology-driven framework for generating in silico thrombi replicating its key replicating their key microstructural traits. REFINE enables controlled, recursive optimization of thrombus topology, making it suitable for accurate photoacoustic modeling and potentially powerful for biomechanical analyses. These digital thrombi are embedded into a multiscale photoacoustic simulation platform that bridges microscale acoustic modeling with macroscale thrombus geometries, enabling efficient and realistic simulation of photoacoustic signal responses. We created unique thrombi microstructure for various compositions and porosities. Our simulation framework effectively links microstructural features to macroscale imaging outcomes, in agreement with previous empirical studies. Our results demonstrate that thrombus microstructure significantly affects photoacoustic spectral responses and can be modeled in silico. These findings highlight that multiscale photoacoustic simulation is a powerful tool for characterizing tissue microstructure and that our framework enables in silico thrombi analysis and diagnostic imaging strategy development
- Open Access
- 24 July 2025
- Published by Elsevier in Journal of the Mechanics and Physics of Solids
- Vol. 205
TopoGEN: Topology-driven microstructure generation for in silico modeling of fiber network mechanics
- 24 July 2025
- Published by Elsevier in Journal of the Mechanics and Physics of Solids
- Vol. 205
Open AccessTopoGEN: Topology-driven microstructure generation for in silico modeling of fiber network mechanics
- Open Access
- 26 September 2023
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 166, 107524
Development of in silico models to guide the experimental characterisation of penile tissue and inform surgical treatment of erectile dysfunction
- 26 September 2023
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 166, 107524
Open AccessDevelopment of in silico models to guide the experimental characterisation of penile tissue and inform surgical treatment of erectile dysfunction
- 6 January 2022
- Published by Elsevier in Journal of Biomechanics
- Vol. 133
Development of a patient-specific cerebral vasculature fluid–structure-interaction model
- 6 January 2022
- Published by Elsevier in Journal of Biomechanics
- Vol. 133
Development of a patient-specific cerebral vasculature fluid–structure-interaction model
- 1 January 2022
- Published by Elsevier in Journal of Biomechanics
- Vol. 130, 110865
A new constitutive model for permanent deformation of blood clots with application to simulation of aspiration thrombectomy
- 1 January 2022
- Published by Elsevier in Journal of Biomechanics
- Vol. 130, 110865
A new constitutive model for permanent deformation of blood clots with application to simulation of aspiration thrombectomy
- 1 December 2021
- Published by Elsevier in Journal of Biomechanics
- Vol. 129, 110731
Measuring the effect of thrombosis, thrombus maturation and thrombolysis on clot mechanical properties in an in-vitro model
- 1 December 2021
- Published by Elsevier in Journal of Biomechanics
- Vol. 129, 110731
Measuring the effect of thrombosis, thrombus maturation and thrombolysis on clot mechanical properties in an in-vitro model
- 1 September 2021
- Published by Elsevier in Journal of Biomechanics
- Vol. 126, 110622
The first virtual patient-specific thrombectomy procedure
- 1 September 2021
- Published by Elsevier in Journal of Biomechanics
- Vol. 126, 110622
The first virtual patient-specific thrombectomy procedure
- Top Cited PapersOpen Access
- 1 August 2021
- Published by Wolters Kluwer Health in Stroke
- Vol. 52 (8) , 2510-2517
Mechanical Characterization of Thrombi Retrieved With Endovascular Thrombectomy in Patients With Acute Ischemic Stroke
Background and Purpose: Mechanical properties of thromboemboli play an important role in the efficacy of endovascular thrombectomy (EVT) for acute ischemic stroke. However, very limited data on mechanical properties of human stroke thrombi are available. We aimed to mechanically characterize thrombi retrieved with EVT, and to assess the relationship between thrombus composition and thrombus stiffness. Methods: Forty-one thrombi from 19 patients with acute stroke who underwent EVT between July and October 2019 were mechanically analyzed, directly after EVT. We performed unconfined compression experiments and determined tangent modulus at 75% strain (E t75 ) as a measure for thrombus stiffness. Thrombi were histologically analyzed for fibrin/platelets, erythrocytes, leukocytes, and platelets, and we assessed the relationship between histological components and E t75 with univariable and multivariable linear mixed regression. Results: Median E t75 was 560 (interquartile range, 393–1161) kPa. In the multivariable analysis, fibrin/platelets were associated with increased E t75 (aβ, 9 [95% CI, 5 to 13]) kPa, erythrocytes were associated with decreased E t75% (aβ, −9 [95% CI, −5 to −13]) kPa. We found no association between leukocytes and E t75 . High platelet values were strongly associated with increased E t75 (aβ, 56 [95% CI, 38–73]). Conclusions: Fibrin/platelet content of thrombi retrieved with EVT for acute ischemic stroke is strongly associated with increased thrombus stiffness. For thrombi with high platelet values, there was a very strong relationship with thrombus stiffness. Our data provide a basis for future research on the development of next-generation EVT devices tailored to thrombus composition.
- 1 August 2021
- Published by Wolters Kluwer Health in Stroke
- Vol. 52 (8) , 2510-2517
Top Cited PapersOpen AccessMechanical Characterization of Thrombi Retrieved With Endovascular Thrombectomy in Patients With Acute Ischemic Stroke
Background and Purpose: Mechanical properties of thromboemboli play an important role in the efficacy of endovascular thrombectomy (EVT) for acute ischemic stroke. However, very limited data on mechanical properties of human stroke thrombi are available. We aimed to mechanically characterize thrombi retrieved with EVT, and to assess the relationship between thrombus composition and thrombus stiffness. Methods: Forty-one thrombi from 19 patients with acute stroke who underwent EVT between July and October 2019 were mechanically analyzed, directly after EVT. We performed unconfined compression experiments and determined tangent modulus at 75% strain (E t75 ) as a measure for thrombus stiffness. Thrombi were histologically analyzed for fibrin/platelets, erythrocytes, leukocytes, and platelets, and we assessed the relationship between histological components and E t75 with univariable and multivariable linear mixed regression. Results: Median E t75 was 560 (interquartile range, 393–1161) kPa. In the multivariable analysis, fibrin/platelets were associated with increased E t75 (aβ, 9 [95% CI, 5 to 13]) kPa, erythrocytes were associated with decreased E t75% (aβ, −9 [95% CI, −5 to −13]) kPa. We found no association between leukocytes and E t75 . High platelet values were strongly associated with increased E t75 (aβ, 56 [95% CI, 38–73]). Conclusions: Fibrin/platelet content of thrombi retrieved with EVT for acute ischemic stroke is strongly associated with increased thrombus stiffness. For thrombi with high platelet values, there was a very strong relationship with thrombus stiffness. Our data provide a basis for future research on the development of next-generation EVT devices tailored to thrombus composition.