SGSabahattin Gündüz

Sabahattin Gündüz

*This is an algorithmically generated author record based on publicly available information.

Sabahattin Gündüz has a total of 208 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Transcatheter Closure or Surgery for Symptomatic Paravalvular Leaks: The Multicenter KISS Registry

    by Ahmet Güner, Cevat Kırma, Mehmet Ertürk, Muhsin Türkmen, Gökhan Alıcı, Can Yücel Karabay, Fatih Uzun, Alev Kılıçgedik, Sabahattin Gündüz, Gamze Babur Güler, et al.

    Background: The optimal treatment of symptomatic paravalvular leak (PVL) remains controversial between transcatheter closure (TC) and surgery. This large‐scale study aimed to retrospectively evaluate the long‐term outcomes of the patients who underwent reoperation or TC of PVLs. Methods and Results: A total of 335 (men, 209 [62.4%]; mean age, 58.15±12.77 years) patients who underwent treatment of PVL at 3 tertiary centers between January 2002 and December 2021 were included. Echocardiographic features, procedure details, and in‐hospital or long‐term outcomes were assessed. The primary end point was defined as the all‐cause death during follow‐up. The regression models were adjusted by applying the inverse probability weighted approach to reduce treatment selection bias. The initial management strategy was TC in 171 (51%) patients and surgery in 164 (49%) cases. Three hundred cases (89.6%) had mitral PVL, and 35 (10.4%) had aortic PVL. The mean left ventricular ejection fraction was 52.03±10.79%. Technical (78.9 versus 76.2%; P =0.549) and procedural success (73.7 versus 65.2%; P =0.093) were similar between both groups. In both univariate and multivariable logistic regression analysis, the in‐hospital mortality rate in the overall population was significantly higher (15.9 versus 4.7%) in the surgery group compared with the TC group (unadjusted odds ratio, 3.13 [95% CI, 1.75–5.88]; P =0.001; and adjusted odds ratio (inverse probability‐weighted), 4.55 [95% CI, 2.27–10.0]; P P =0.435; and adjusted HR (inverse probability‐weighted), 1.11 [95% CI, 0.67–1.81]; P =0.679). Conclusions: The current data suggest that percutaneous closure of PVL was associated with lower early and comparable long‐term mortality rates compared with surgery.


  • Open Access

    Lessons Learned From Intermittent Dysfunction of Mechanical Heart Valve

    by Semih Kalkan, Ahmet Guner, Macit Kalcik, Mustafa Ozan Gursoy, Sabahattin Gunduz, Emrah Bayram, Mahmut Yesin, Suleyman Karakoyun, Mustafa Ferhat Keten, Mehmet Ozkan

    Prosthetic,valve disease,dysfunction,echocardiography


  • Open Access

    Management of antithrombotic therapy after prosthetic valve implantation

    by Macit Kalçık, Ahmet Güner, Sabahattin Gündüz, Mehmet Özkan

  • Characteristic localization patterns of thrombus on various brands of bileaflet mitral mechanical heart valves as assessed by three-dimensional transesophageal echocardiography and their relationship with thromboembolism

    by Munevver Sari, Zubeyde Bayram, Mehmet Ayturk, Emrah Bayam, Semih Kalkan, Ahmet Guner, Macit Kalcik, Mustafa Ozan Gursoy, Sabahattin Gunduz, Mehmet Ozkan

    Three-dimensional transesophageal echocardiography (3D-TEE) provides detailed images of prosthetic valve thrombosis (PVT). However, data regarding PVT localization patterns based on 3D-TEE and their association with clinical findings among various bileaflet mitral prosthetic valve brands is lacking. The locations of thrombi were classified into 4 groups according to hinge and annulus involvement based on 3D-TEE: ring-like PVT involving entire mitral annulus (type-1), PVT involving peri-hinge(s) region and extends through some part of the annulus (type-2), PVT involving mitral annulus without involving hinge(s) region (type-3), and PVT involving only (peri)hinge(s) area (type-4). This study was conducted in 265 patients (male: 71, mean age: 46.3 ± 12.7 years) with mitral PVT, including 150 St Jude Medical (SJM), 65 Carbomedics, 29 Medtronic ATS open-pivot, and 21 Sorin bileaflet mechanical valves. There was a significant difference in most common PVT localization patterns between different prosthetic valves (type-1 for Carbomedics and Sorin; type-2 for SJM and type-3 for ATS valves; p < 0.001). Additionally, PVT involving only (peri)hinge region(s) (type-4) was mostly observed in patients with SJM valves (18%). (Peri)hinge(s) area involvement was observed in the majority of study patients (78.1%). In patients who presented with thromboembolism, the most common PVT localization pattern was type-1 (53%). Increased age, low international normalized ratio on admission, PVT with a mobile part > 2 mm, type-1 and type-4 PVT were associated with thromboembolic events. In conclusion, thrombus can be displayed in distinct locations in several types of bileaflet mechanical valves due to different design, hinge and pivot mechanisms, which can be complicated with thromboembolic events.


  • Diagnosis, treatment & management of prosthetic valve thrombosis: the key considerations

    by Sabahattin Gündüz, Macit Kalçık, Mustafa Ozan Gürsoy, Ahmet Güner, Mehmet Özkan

    Introduction: Prosthetic heart valve thrombosis is a life-threatening complication after valve replacement surgery. Although subtherapeutic anticoagulation is the main cause, there are many other conventional and esoteric predisposing factors. Areas covered: The etiopathogenesis, diagnosis and management of prosthetic heart valve thrombosis with particular focus on conventional and esoteric predisposing factors, diagnosis with multimodality imaging and current therapeutic approaches were covered. Expert opinion: Subtherapeutic anticoagulation remains the key driving force for development of prosthetic valve thrombosis. However, cardiologists should be cognizant of other frequent or rare conventional and esoteric causes. The diagnosis is now more straightforward with the use of multimodality imaging. Transthoracic and transesophageal echocardiography with or without real-time three-dimensional imaging are the current gold standard modalities. Multidetector computed tomography is now a major complementary tool. The favorable clinical outcomes with recently introduced slow or ultra-slow infusions of alteplase, as compared to relatively poor surgical results, has rendered thrombolytic therapy the first-line treatment option in most eligible patients with prosthetic valve thrombosis. Surgical treatment could be reserved in whom thrombolytic therapy is contraindicated, or has already failed. The efficacy and safety of thrombolytic therapy as compared to surgery should be confirmed with large observational cohorts, and ideally randomized trials.


  • Open Access

    Pseudoaneurysm after carotid stenting: A case report and review of literature

    by Ahmet Güner, Selçuk Pala, Sabahattin Gündüz, Şeyhmus Külahçıoğlu, Ezgi Gültekin Güner

    Carotid artery stenting has been a widely used interventional treatment method for the last 3 decades in the treatment of carotid artery stenosis. In the current literature, unlike major cardiovascular complications, less emphasis has been placed on carotid pseudoaneurysm (PA). A carotid artery PA can be caused by trauma, spontaneous infection, vasculitis, or it may be iatrogenic. However, the incidence of PA secondary to carotid stenting is extremely rare. Although it may be completely asymptomatic in rare instances, it usually progresses symptomatically (neck swelling, nerve compression, respiratory distress, hoarseness, dysphagia, and ischemic cerebrovascular events). Doppler ultrasound, contrast-enhanced computed tomography, and conventional angiography are the main diagnostic tools. Primary closure, including graft interposition, has been described as a surgical therapeutic option. An endovascular approach with placement of a covered or bare metal stent is an alternative treatment method to surgery.


  • A rare complication of mechanical aortic valve replacement: Separation in the region of the mitral‐aortic intervalvular fibrosa

    by Mehmet Celik, Ahmet Güner, Alev Kılıçgedik, Sabahattin Gunduz, Abdulrahman Naser, Elif Eroglu Büyüköner, Muzaffer Kahyaoglu, Cagatay Onal, Gokhan Kahveci

    A 28‐year‐old man was admitted to our emergency service with a shortness of breath and palpitation. On admission, his blood pressure was high and he was in hypertensive pulmonary edema. His physical examination showed rales in both lungs and pansystolic murmur at mitral focus. His medical history included aortic valve replacement (AVR) because of native aortic valve infective endocarditis. Transthoracic echocardiography (TTE) showed normal functional aortic valve. Color flow imaging demonstrated severe mitral regurgitation with posterior eccentric jet. To examine in detail, transesophageal echocardiography (TEE) and three‐dimensional (3D) echocardiography were performed. TEE disclosed a separation in the subaortic curtain leading to severe mitral regurgitation from the left ventricle to the left atrium. In addition to severe mitral regurgitation with posterior eccentric jet, 26‐mm‐long pouch was seen in mitral‐aortic intervalvular fibrosa (MAIVF) at 120° TEE view. This pouch was separated from the mitral anterior leaflet junction releasing the mitral anterior leaflet and causing prolapse and chorda rupture in the A2 scallop of the mitral anterior leaflet. The MAIVF connects the anterior mitral leaflet to the posterior portion of the aortic annulus. The separation of the MAIVF represents a complication of the aortic valve replacement.


  • Pseudoaneurysm of the thyrocervical trunk after coronary intervention from the right radial approach

    by Emine Alpay, Ahmet Guner, Nuri Havan, Ozge Akgun, Muzaffer Kahyaoglu, Sabahattin Gunduz, Mehmet Celik, Ozkan Candan, Cetin Gecmen


  • Evaluation of the congenital supravalvular aortic stenosis by different imaging modalities

    by Ahmet Guner, Nuri Havan, Sabahattin Gunduz, Taylan Akgun, Busra Guvendi, Gokhan Kahveci

    A 36‐year‐old female was admitted to hospital exhibiting chest pain, dyspnea, and a heart murmur on the right upper sternal border, radiating to both carotid arteries. The blood pressure of the patient's right arm exceeded the pressure in the left by 25 mm Hg (Coanda effect). In spite of laboratory results that did not fall outside the expected range, the left ventricle was revealed to be hypertrophic following electrocardiography. Transthoracic echocardiography revealed a severe supravalvular aortic stenosis (SVAS) with a peak Doppler velocity of 6.04 cm/s and an estimated mean pressure gradient of 89 mm Hg, with moderate aortic and mitral regurgitation. Contrast‐enhanced computed tomography (CCT) indicated a partial hourglass‐shaped narrowing of the ascending aorta. Lesions associated with supravalvular stenosis of the pulmonary artery, patent ductus arteriosus, and aortic coarctation were ruled out by the CCT. Congenital SVAS is a rare heart condition, and three anatomically distinct forms have been described. The most common type is the “hourglass,” which produces a marked thickening and disorganization of the aortic tissue, producing a constricting annular ridge at the superior margin of the sinuses of Valsalva.