NANaser Alnusif

Naser Alnusif

*This is an algorithmically generated author record based on publicly available information.

Naser Alnusif has a total of 36 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Outcomes of arthroscopic assisted fixation of distal clavicle fractures using an adjustable button

    by Retaj Bahbahani, Ali Lari, Amr Elias Ibrahim, Khalaf Ebrahim, Naser Alnusif, Fahad Alkhalaf

  • Open Access

    The association between lower limb fractures and weight gain in adults: a prospective analysis of body mass index trends

    by Ali Lari, Abdullah Haidar, Hussain Mohammad, Mohammad Makhseed, Mejbel Alajmi, Retaj Bahbahani, Majed Almutairi, Naser Alnusif, Eisa Lari

    Purpose: Despite understanding the connection between obesity and fracture risk, there is limited research on the implications of lower limb fractures on subsequent changes in body mass index (BMI). Our study aimed to assess the impact of lower limb fractures on BMI alterations over an 18-month period. Methods: A multi-center, prospective cohort study was conducted between January 2021 to June 2023, involving 494 adults with lower limb fractures. Participants were recruited within 2 weeks post-injury and were assessed for demographics, injury details, and weight at seven distinct time points. By 18 months, the primary outcome was the mean weight gain. Results: The average age of the participants was 39 (± 12.7) with a baseline weight and BMI of 80.4 kg and 27.6, respectively. At the 18-month follow-up, 75% of patients experienced an average weight increase in 4 kg (± 5.39 kg), equating to a BMI rise of 1.39 (± 1.88). Most patients attributed weight changes to their injury, with nearly half expressing distress from their weight change. Only 37% believed that they had resumed their previous activity levels by the final follow-up. Approximately 31% of the patients sought some form of external weight management care in the form of nutritionist advice, training programs, medication and weight management procedures. Conclusions: Lower limb fractures significantly affect weight gain over an 18-month period, with substantial psychological and physical consequences. Healthcare providers should anticipate potential weight gain post-fracture and incorporate strategies addressing both physical and mental aspects of rehabilitation to enhance recovery outcomes. Early and even immediate weight bearing may play a pivotal role in mitigating weight changes and returning the patient to their previous level of activity. Further detailed studies focusing on different fractures and postoperative interventions are recommended.


  • Open Access

    Strength after the arthroscopic Latarjet procedure: Are shoulder internal rotation, elbow flexion & supination strength decreased?

    by Naser Alnusif, Ali Lari, Saad AlQahtani, George S Athwal

    Background: The Latarjet procedure is an effective shoulder stabilizing surgery, however, the procedure results in an alteration of anatomy that may result in shoulder and elbow weakness. Thus, the purpose of this study was to assess post-operative shoulder and elbow strength after the Latarjet procedure. We hypothesized that shoulder and elbow strength are not affected after the procedure. Methods: The study group consisted of patients that had undergone the arthroscopic Latarjet procedure. An isokinetic dynamometer was used to evaluate the strength of bilateral shoulder internal rotation, elbow flexion, forearm supination using peak torque (N/m), as well as grip strength (kilograms). Shoulder range of motion and the potential effects of hand dominance were further analysed. Results: Nineteen patients with a mean age of 29 years and an average follow up of 47 months were included. Shoulder internal rotation strength, elbow flexion and forearm supination strength and grip strength were not significantly different when compared to the non-operative side ( p > 0.13). The range of shoulder external rotation was significantly reduced ( p < 0.001) on the Latarjet side. Conclusion: The results from this study demonstrate no statistically significant differences in the strength of shoulder internal rotation, elbow flexion, forearm supination or grip strength despite the surgical alterations to the subscapularis and conjoint tendon.


  • Open Access

    Circumferential periosteal block versus hematoma block for the reduction of distal radius and ulna fractures: a randomized controlled trial

    by Ali Lari, Ali Jarragh, Mohammad Alherz, Abdullah Nouri, Mousa Behbehani, Naser Alnusif

    Purpose: To assess the analgesic efficacy of the circumferential periosteal block (CPB) and compare it with the conventional fracture hematoma block (HB). Methods: This study was a prospective single-center randomized controlled trial performed in a national orthopedic hospital. Fifty patients with displaced distal radius (with or without concomitant ulna) fractures requiring reduction were randomized to receive either CPB or HB prior to the reduction. Pain was sequentially measured using the visual analogue scale (VAS) across three stages; before administration of local anesthesia (baseline), during administration (injection) and during manipulation and immobilization (manipulation). Further, the effect of demographic factors on the severity of pain was analyzed in multivariate regression. Finally, complications and end outcomes were compared across both techniques. Results: Patients receiving CPB experienced significantly less pain scores during manipulation (VAS = 0.64) compared with HB (VAS = 2.44) (p = < 0.0001). There were no significant differences between groups at baseline (P = 0.55) and injection (P = 0.40) stages. Conclusion: The CPB provides a superior analgesic effect over the conventional HB with no documented complications in either technique. Level of evidence: Therapeutic Level II.


  • Open Access

    Comparison of pain and extent of anesthesia in digital blocks for isolated finger lacerations

    by Ali Jarragh, Ali Lari, Waleed Burhamah, Mohammed Alherz, Abdullah Nouri, Yahia Alshammari, Ameer Al-Jasim, Sulaiman AlRefai, Naser Alnusif

    OBJECTIVES: Digital injuries are among the most common presentations to the emergency department. In order to sufficiently examine and manage these injuries, adequate, prompt, and predictable anesthesia is essential. In this trial, we aim to primarily compare the degree of pain and anesthesia onset time between the two-injection dorsal block technique (TD) and the single-injection volar subcutaneous block (SV) technique. Further, we describe the temporal and anatomical effects of both techniques for an accurate delineation of the anesthetized regions. METHODS: This is a single-center prospective randomized controlled trial involving patients presenting with isolated wounds to the fingers requiring primary repair under local anesthesia. Patients were randomized to either the SV or TD blocks. The primary outcome was procedure-related pain (Numerical Rating Scale). Further, we assessed the extent of anesthesia along with the anesthesia onset time. RESULTS: A total of 100 patients were included in the final analysis, 50 on each arm of the study. The median pain score during injection was significantly higher in patients who received TD block than patients who received SV block (median [interquartile range] = 4 [2.25, 5.00] vs. 3.00 [2.00, 4.00], respectively, P = 0.006). However, anesthesia onset time was not statistically different among the groups (P = 0.39). The extent of anesthesia was more predictable in the dorsal block compared to the volar block. CONCLUSION: The single-injection volar subcutaneous blocks are less painful with a similar anesthesia onset time. Injuries presenting in the proximal dorsal region may benefit from the two-injection dorsal blocks, given the anatomical differences and timely anesthesia of the region.


  • Open Access

    Humeral head subluxation in Walch type B shoulders varies across imaging modalities

    by Bogdan A. Matache, Naser Alnusif, Jean Chaoui, Gilles Walch, George S. Athwal


  • Open Access

    Drill wobble – effect on femoral tunnel aperture during anterior cruciate ligament reconstruction

    by Naser Alnusif, Adam Hart, Maher Baroudi, Robert Marien, Mark Burman, Paul A. Martineau

    Background: In anterior cruciate ligament reconstruction performed using cortical button fixation on the femur, we have observed a “wobble” effect that can occur when a cannulated femoral drill is used over a guide pin that is not securely fixed in bone. Our study assessed the effect of drill “wobble” on femoral tunnel aperture in sawbones.Methods: Femoral tunnels were drilled in sawbones, which had been divided in two groups of 10 each, per drilling technique. The “wobble” technique group had the smaller cortical button drill passed before drilling the graft socket with the bigger diameter femoral drill. In contrast, in the “non‐wobble” technique group, the smaller cortical button drill was passed after drilling the graft socket. The aperture dimensions: antero‐posterior, proximo‐distal and oblique, as well as the length of each tunnel, were measured.Results: While the average dimensions of the tunnels were similar between the two techniques, there was significantly more variation in the antero‐posterior measurements for the wobble technique as compared to the non‐wobble technique (mean 7.3 mm, SD 0.28 mm, and mean 7.3 mm, SD 0.11 mm, respectively; Brown‐Forsythe test, p 0.02).Conclusion: We conclude that using the “socket first” “non‐wobble” technique is a single surgical technical step surgeons can employ to decrease variability in tunnel aperture and size.