TNThanh Cong Nguyen

Thanh Cong Nguyen

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Thanh Cong Nguyen has a total of 47 co-authors. Here are the top co-authors by number of shared publications:

  • Efstratios Skafidas

    Department of Electrical and Electronic Engineering Faculty of Engineering and Information Technology The University of Melbourne Parkville VIC 3010 Australia

    10 shared publications
  • Babak Nasr

    Centre for Neural Engineering, The University of Melbourne, Carlton, VIC 3053, Australia

    4 shared publications
  • Duc Hau Huynh

    University of Melbourne Department of Electrical and Electronic Engineering Parkville, VIC 3010, Australia and Centre for Neural Engineering Parkville, VIC 3010, Australia

    3 shared publications
  • Efstratios Skafidas

    Department of Electrical and Electronic Engineering and the Department PsychiatryCentre for Neural Engineering, University of Melbourne, Melbourne, VIC, Australia

    3 shared publications
  • Gursharan Chana

    Department of Psychiatry, Royal Melbourne HospitalCenter for Neural Engineering, University of Melbourne, Melbourne, VIC, Australia

    3 shared publications
  • Phuong Duc Nguyen

    University of Melbourne Department of Electrical and Electronic Engineering Parkville, VIC 3010, Australia and Centre for Neural Engineering Parkville, VIC 3010, Australia

    3 shared publications

Latest Publications

  • Open Access

    A Label-Free, Quantitative Fecal Hemoglobin Detection Platform for Colorectal Cancer Screening

    by Gita V. Soraya, Thanh C. Nguyen, Chathurika D. Abeyrathne, Duc H. Huynh, Jianxiong Chan, Phuong D. Nguyen, Babak Nasr, Gursharan Chana, Patrick Kwan, Efstratios Skafidas

    The early detection of colorectal cancer is vital for disease management and patient survival. Fecal hemoglobin detection is a widely-adopted method for screening and early diagnosis. Fecal Immunochemical Test (FIT) is favored over the older generation chemical based Fecal Occult Blood Test (FOBT) as it does not require dietary or drug restrictions, and is specific to human blood from the lower digestive tract. To date, no quantitative FIT platforms are available for use in the point-of-care setting. Here, we report proof of principle data of a novel low cost quantitative fecal immunochemical-based biosensor platform that may be further developed into a point-of-care test in low-resource settings. The label-free prototype has a lower limit of detection (LOD) of 10 µg hemoglobin per gram (Hb/g) of feces, comparable to that of conventional laboratory based quantitative FIT diagnostic systems.


  • Open Access

    Environmentally friendly power generator based on moving liquid dielectric and double layer effect

    by D. H. Huynh, T. C. Nguyen, P. D. Nguyen, C. D. Abeyrathne, S. Hossain, R. Evans, E. Skafidas

    An electrostatic power generator converts mechanical energy to electrical energy by utilising the principle of variable capacitance. This change in capacitance is usually achieved by varying the gap or overlap between two parallel metallic plates. This paper proposes a novel electrostatic micro power generator where the change in capacitance is achieved by the movement of an aqueous solution ofNaCl. A significant change in capacitance is achieved due to the higher than air dielectric constant of water and the Helmholtz double layer capacitor formed by ion separation at the electrode interfaces. The proposed device has significant advantages over traditional electrostatic devices which include low bias voltage and low mechanical frequency of operation. This is critical if the proposed device is to have utility in harvesting power from the environment. A figure of merit exceeding 10000(108μW)/(mm2HzV2) which is two orders of magnitude greater than previous devices, is demonstrated for a prototype operating at a bias voltage of 1.2 Vand a droplet frequency of 6 Hz. Concepts are presented for large scale power harvesting.


  • Enhanced thermoelectric performance of graphene nanoribbon-based devices

    by Sharafat Hossain, Duc Hau Huynh, Phuong Duc Nguyen, Liming Jiang, Thanh Cong Nguyen, Feras Al-Dirini, Faruque M. Hossain, Efstratios Skafidas

    There have been numerous theoretical studies on exciting thermoelectric properties of graphene nano-ribbons (GNRs); however, most of these studies are mainly based on simulations. In this work, we measure and characterize the thermoelectric properties of GNRs and compare the results with theoretical predictions. Our experimental results verify that nano-structuring and patterning graphene into nano-ribbons significantly enhance its thermoelectric power, confirming previous predictions. Although patterning results in lower conductance (G), the overall power factor (S2G) increases for nanoribbons. We demonstrate that edge roughness plays an important role in achieving such an enhanced performance and support it through first principles simulations. We show that uncontrolled edge roughness, which is considered detrimental in GNR-based electronic devices, leads to enhanced thermoelectric performance of GNR-based thermoelectric devices. The result validates previously reported theoretical studies of GNRs and demonstrates the potential of GNRs for the realization of highly efficient thermoelectric devices.


  • GFAP Antibody Detection Using Interdigital Coplanar Waveguide Immunosensor

    by Chathurika D. Abeyrathne, Duc Hau Huynh, Ting Ting Lee, Thanh Cong Nguyen, Babak Nasr, Gursharan Chana, Efstratios Skafidas

    Glioma is the most common primary brain tumor with its early detection remaining a challenge. Autoantibodies against glial fibrillary acidic protein (GFAP) have shown the highest differential expression compared with the other glioma expressed autoantibodies. In this paper, an immunosensor to detect GFAP antibody levels is developed using an interdigital coplanar waveguide (ID-CPW). The ID-CPW is fabricated on an SiO2/Si substrate with the CPW and inter-digital electrode conducting layers made using Cr/Au. The sensor is functionalized, and protein extracted from astrocytes is immobilized on the surface. Sensitivity and dynamic range are ascertained using varying the concentrations of a commercial, polyclonal antibody to GFAP. The electrical detection of antigen-antibody binding is performed in both dry and wet environments across the 1-25-GHz range. Our results show that the proposed sensor can detect antibodies to GFAP to a minimum concentration of 2.9 pg/ml with a turnaround time in less than 3 h. Our electrical measurements indicate an improved sensitivity compared with the state-of-the-art optical detection methods. The immunosensor, developed to detect antibody against GFAP, is the first to show the applicability in the detection of glioma using the GFAP autoantibodies.


  • Lab on a chip sensor for rapid detection and antibiotic resistance determination of Staphylococcus aureus

    by Chathurika D. Abeyrathne, Duc H. Huynh, Thomas W. Mcintire, Thanh C. Nguyen, Babak Nasr, Daniela Zantomio, Gursharan Chana, Iain Abbott, Peter Choong, Mike Catton, et al.

    The Gram-positive bacterium, Staphylococcus aureus (S. aureus), is a major pathogen responsible for a variety of infectious diseases ranging from cellulitis to more serious conditions such as septic arthritis and septicaemia. Timely treatment with appropriate antibiotic therapy is essential to ensure clinical defervescence and to prevent further complications such as infective endocarditis or organ impairment due to septic shock. To date, initial antibiotic choice is empirical, using a “best guess” of likely organism and sensitivity- an approach adopted due to the lack of rapid identification methods for bacteria. Current culture based methods take up to 5 days to identify the causative bacterial pathogen and its antibiotic sensitivity. This paper provides proof of concept for a biosensor, based on interdigitated electrodes, to detect the presence of S. aureus and ascertain its sensitivity to flucloxacillin rapidly (within 2 hours) in a cost effective manner. The proposed method is label-free and uses non-faradic measurements. This is the first study to successfully employ interdigitated electrodes for the rapid detection of antibiotic resistance. The method described has important potential outcomes of faster definitive antibiotic treatment and more rapid clinical response to treatment.


  • CMOS compatible fabrication process of MEMS resonator for timing reference and sensing application

    by Duc H. Huynh, Phuong D. Nguyen, Thanh C. Nguyen, Stan Skafidas, Robin Evans

  • Vertical Nanowire Electrode Arrays as Novel Electrochemical Label‐Free Immunosensors

    by Babak Nasr, Gursharan Chana, Ting Ting Lee, Thanh Nguyen, Chathurika Abeyrathne, Giovanna M. D'Abaco, Mirella Dottori, Efstratios Skafidas

    A new method for the fabrication of a label-free electrochemical immunosensor based on vertical nanowires (VNWs) is proposed. The VNWs are functionalized to detect antibodies against a major astrocytic structural protein component, glial fibrillary acidic protein (GFAP). It is revealed that the interaction of GFAP-antibody with functionalized VNWs leads to a clear change in device conductance and the corresponding capacitance.


  • Negative differential resistance effect in planar graphene nanoribbon break junctions

    by Phuong Duc Nguyen, Thanh Cong Nguyen, Faruque M. Hossain, Duc Hau Huynh, Robin Evans, Efstratios Skafidas

    Graphene is an interesting material with a number of desirable electrical properties. Graphene-based negative differential resistance (NDR) devices hold great potential for enabling the implementation of several elements required in electronic circuits and systems. In this article we propose a novel device structure that exhibits NDR using single layer graphene that is able to be fabricated using standard lithography techniques. Using theoretical simulation, we show that graphene nanoribbon (GNR) junctions exhibit NDR effect if a gap is introduced in the structure in the transport direction of the ribbon. Using standard lithography techniques, we produce a GNR and use electro-migration to create a nanogap by breaking the GNR device. Scanning electron microscopy images show the formation of a tunnel gap. The predicted NDR phenomenon is experimentally verified in the current–voltage characteristic of the device. The linear and non-linear characteristics of the I–V responses before and after breakdown confirm that the NDR effect arises from the tunnel gap.


  • High frequency characterization of graphene nanoribbon interconnects

    by Phuong Duc Nguyen, Thanh Cong Nguyen, Anh Trong Huynh, Efstratios Skafidas


  • Improvement of decay time in nematic-liquid-crystal-loaded coplanar-waveguide-type microwave phase shifter by polymer stabilizing method

    by Thanh Nguyen, Shuhei Umeno, Hiroki Higuchi, Hirotsugu Kikuchi, Hiroshi Moritake

    Polymer stabilization by UV light irradiation in nematic liquid crystals is proposed to improve the decay time of coplanar-waveguide-type microwave phase shifters. The effect of polymer concentration on the decay time of polymer-stabilized nematic liquid crystals is confirmed by a dielectric experiment on a liquid-crystal-sandwiched indium–tin-oxide (ITO) glass cell before loading into a coplanar-waveguide-type microwave phase shifter. The decay time, phase shift value, and insertion loss of microwave phase shifters with different polymer concentrations are measured. The decay time of polymer-stabilized nematic liquid crystals in the microwave phase shifter markedly decreases compared with that of pure nematic liquid crystals. It is confirmed that the use of polymer-stabilized nematic liquid crystals is effective to improve the response time of microwave phase shifters.