Axel Boese
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Axel Boese has a total of 260 co-authors. Here are the top co-authors by number of shared publications:
- Michael Friebe
Faculty of Computer Science, AGH University of Krakow, Krakow, Poland
39 shared publications Michael Friebe
AGH University of Science and Technology, Department of Biocybernetics and Biomedical Engineering, Krakow , Poland
36 shared publications- Alfredo Illanes
Faculty of Computer Science and Research Campus STIMULATE, Otto-von-Guericke University, Universitätsplatz 2, 39106 Magdeburg, Germany
27 shared publications Alfredo Illanes
SURAG Medical GmbH, Leipzig , Germany
22 shared publications- Nazila Esmaeili
University Medical Center Göttingen
18 shared publications - Christoph Arens
Department of Otorhinolaryngology, Head and Neck Surgery and Plastic Surgery, University Hospital Giessen & Marburg, Giessen Campus, 35392 Giessen, Germany
10 shared publications
Latest Publications
- Open Access
- 10 October 2026
- Published by MDPI AG in Diagnostics
- Vol. 16 (20) , 3297
Machine Learning Detection of Peritoneal Entry from Vibroacoustic Signals During Veress Needle Insertion
Background/Objectives: Establishing access is a hazardous step of laparoscopic surgery, and the widely used Veress needle offers only subjective tactile and auditory cues for peritoneal entry. Proximal vibroacoustic (VA) sensing captures needle–tissue interaction non-invasively and is known to contain a characteristic peritoneal puncture signature, which could help surgeons to precisely identify peritoneal entry. However, the VA signature has been evaluated only by retrospective, video-anchored and manual signal analysis. We investigate whether peritoneal entry can instead be detected automatically. Methods: Cavity entry is framed as a binary classification of VA signal segments, and four model families are benchmarked under a single unified protocol: a one-dimensional convolutional neural network (1D CNN), a multilayer perceptron, a bidirectional long short-term memory network (LSTM), and a support vector machine (SVM) with a radial basis function kernel. All models were trained, selected, and threshold-tuned on a synthetic abdominal phantom (996 segments) and tested once on an independent porcine cadaver dataset (154 cavity, 462 non-cavity signals) so that every test result measures generalisation across a phantom-to-porcine domain shift. Results: The 1D CNN performed the best (accuracy 0.869, AUROC 0.904, macro F1 0.833, cavity recall 0.818), closely followed by the SVM (AUROC 0.900, AUPRC 0.878). Conclusions: These results establish the feasibility of automatically detecting peritoneal entry across a phantom-to-porcine domain shift and extend the descriptive cadaveric characterisation of the puncture signature toward the automated machine learning-based detection of peritoneal entry in laparoscopic access with a Veress needle.
- 10 October 2026
- Published by MDPI AG in Diagnostics
- Vol. 16 (20) , 3297
Open AccessMachine Learning Detection of Peritoneal Entry from Vibroacoustic Signals During Veress Needle Insertion
Background/Objectives: Establishing access is a hazardous step of laparoscopic surgery, and the widely used Veress needle offers only subjective tactile and auditory cues for peritoneal entry. Proximal vibroacoustic (VA) sensing captures needle–tissue interaction non-invasively and is known to contain a characteristic peritoneal puncture signature, which could help surgeons to precisely identify peritoneal entry. However, the VA signature has been evaluated only by retrospective, video-anchored and manual signal analysis. We investigate whether peritoneal entry can instead be detected automatically. Methods: Cavity entry is framed as a binary classification of VA signal segments, and four model families are benchmarked under a single unified protocol: a one-dimensional convolutional neural network (1D CNN), a multilayer perceptron, a bidirectional long short-term memory network (LSTM), and a support vector machine (SVM) with a radial basis function kernel. All models were trained, selected, and threshold-tuned on a synthetic abdominal phantom (996 segments) and tested once on an independent porcine cadaver dataset (154 cavity, 462 non-cavity signals) so that every test result measures generalisation across a phantom-to-porcine domain shift. Results: The 1D CNN performed the best (accuracy 0.869, AUROC 0.904, macro F1 0.833, cavity recall 0.818), closely followed by the SVM (AUROC 0.900, AUPRC 0.878). Conclusions: These results establish the feasibility of automatically detecting peritoneal entry across a phantom-to-porcine domain shift and extend the descriptive cadaveric characterisation of the puncture signature toward the automated machine learning-based detection of peritoneal entry in laparoscopic access with a Veress needle.
- 26 September 2026
- Published by Springer Nature
- p. 616-625
Where Is the Needle Tip? VA Sensing Reveals Hidden Needle-Tissue Transitions During US Guidance
- 26 September 2026
- Published by Springer Nature
- p. 616-625
Where Is the Needle Tip? VA Sensing Reveals Hidden Needle-Tissue Transitions During US Guidance
- 26 September 2026
- Published by Springer Nature
- p. 606-615
When Tissue Speaks: Vibroacoustic Monitoring of Tissue Response During Electrosurgery
- 26 September 2026
- Published by Springer Nature
- p. 606-615
When Tissue Speaks: Vibroacoustic Monitoring of Tissue Response During Electrosurgery
- Open Access
Ex Vivo Differentiation of Cartilage Degeneration Severity and Subchondral Bone Using Vibroacoustic Signals from Instrument–Tissue Interaction
Osteoarthritis (OA) of the knee is characterized by cartilage matrix degeneration, which eventually leads to joint dysfunction and surgical replacement. Preoperative radiography, the standard for treatment decision making, provides limited information on the extent of degeneration, emphasizing the need for quantitative intraoperative techniques. This study evaluates the potential of vibroacoustic signals generated from instrument–tissue interactions to assess cartilage degeneration severity. A total of 136 ex vivo cartilage specimens of varying degeneration severity, histologically graded using the OARSI score, were collected from 41 patients undergoing arthroplasty. The specimens were classified into three groups: healthy cartilage (OARSI ), degenerated cartilage (OARSI ≥ 2.5), and subchondral bone. Vibroacoustic signals were captured during specimen palpation using a vibration measurement system affixed to a surgical probe. 26 characteristic signal features were extracted using Continuous-Wavelet Transformation, and their discriminative power was assessed using Support Vector Machine and k-Nearest-Neighbor classifiers under patient- and specimen-level grouped cross-validation with nested hyperparameter tuning. Bone was distinguished from cartilage with 84– recall. Healthy cartilage (OARSI ) was identifiable with 74– sensitivity, whereas the specificity for degenerated cartilage (OARSI ≥ 2.5) remained limited (40–), constituting the principal limitation of the approach. Interpreting the binary cartilage classification as a diagnostic test, a receiver-operating characteristic (ROC) analysis yielded an area under the curve (AUC) of up to ( CI [, ]). The study demonstrates that vibroacoustic signals from instrument–tissue interactions may provide complementary information for intraoperative cartilage evaluation and may contribute to decision making in arthroplasty, while the reliable grading of cartilage degeneration remains an open challenge.Open AccessEx Vivo Differentiation of Cartilage Degeneration Severity and Subchondral Bone Using Vibroacoustic Signals from Instrument–Tissue Interaction
Osteoarthritis (OA) of the knee is characterized by cartilage matrix degeneration, which eventually leads to joint dysfunction and surgical replacement. Preoperative radiography, the standard for treatment decision making, provides limited information on the extent of degeneration, emphasizing the need for quantitative intraoperative techniques. This study evaluates the potential of vibroacoustic signals generated from instrument–tissue interactions to assess cartilage degeneration severity. A total of 136 ex vivo cartilage specimens of varying degeneration severity, histologically graded using the OARSI score, were collected from 41 patients undergoing arthroplasty. The specimens were classified into three groups: healthy cartilage (OARSI ), degenerated cartilage (OARSI ≥ 2.5), and subchondral bone. Vibroacoustic signals were captured during specimen palpation using a vibration measurement system affixed to a surgical probe. 26 characteristic signal features were extracted using Continuous-Wavelet Transformation, and their discriminative power was assessed using Support Vector Machine and k-Nearest-Neighbor classifiers under patient- and specimen-level grouped cross-validation with nested hyperparameter tuning. Bone was distinguished from cartilage with 84– recall. Healthy cartilage (OARSI ) was identifiable with 74– sensitivity, whereas the specificity for degenerated cartilage (OARSI ≥ 2.5) remained limited (40–), constituting the principal limitation of the approach. Interpreting the binary cartilage classification as a diagnostic test, a receiver-operating characteristic (ROC) analysis yielded an area under the curve (AUC) of up to ( CI [, ]). The study demonstrates that vibroacoustic signals from instrument–tissue interactions may provide complementary information for intraoperative cartilage evaluation and may contribute to decision making in arthroplasty, while the reliable grading of cartilage degeneration remains an open challenge. - Open Access
- 9 June 2026
- Published by MDPI AG in Diagnostics
- Vol. 16 (12) , 1780
Feasibility of Vibroacoustic Sensing for Detection of Peritoneal Entry During Laparoscopic Access: A Pilot Study in a Human Body Donor
Background/Objectives: Establishing laparoscopic access remains a critical and complication-prone step in minimally invasive surgery. Previous work has shown that proximal vibroacoustic sensing can identify peritoneal puncture events in porcine cadavers. The present pilot study evaluated whether these findings translate to human anatomy under controlled, ex vivo conditions. Methods: A vibroacoustic sensing prototype was proximally attached to a standard Veress needle during 14 insertions into a fresh human body donor (within 48 h post-mortem). An endoscope was introduced laterally to provide visual ground truth of peritoneal entry. Vibroacoustic signals were recorded at the proximal end of the instrument. Time–frequency analyses, transient excitation detection, and statistical comparisons were performed to assess whether (1) peritoneal puncture can be identified in the vibroacoustic signal, (2) signal phases and dynamics correspond to those previously observed in porcine cadavers, and (3) peritoneal punctures can be statistically differentiated from non-peritoneal events. Results: All 14 peritoneal punctures were identifiable in the vibroacoustic signal under the experimental conditions. Characteristic signal phases previously described in porcine tissue, including transient excitation associated with cavity entry, were consistently reproduced with comparable temporal and spectral profiles. Statistical analyses demonstrated group-level differences between peritoneal and non-peritoneal events, and the peritoneal puncture was the highest-energy event of its insertion in 13 of 14 cases (92.9%). Conclusions: Under the controlled ex vivo conditions of this single-donor pilot study, vibroacoustic sensing was feasible for identifying peritoneal puncture in human tissue and reproduced signal dynamics observed in porcine models. To our knowledge, this is the first demonstration of the proximal vibroacoustic sensing concept on a human body donor and the first cross-species replication of the previously reported puncture phase structure, establishing an important translational stepping stone between animal cadaver studies and in vivo investigations. The study demonstrates feasibility rather than clinical reliability: the single-donor design and the retrospective annotation framework limit generalizability. Prospective validation in living patients, across multiple subjects and operators, is required before clinical deployment.
- 9 June 2026
- Published by MDPI AG in Diagnostics
- Vol. 16 (12) , 1780
Open AccessFeasibility of Vibroacoustic Sensing for Detection of Peritoneal Entry During Laparoscopic Access: A Pilot Study in a Human Body Donor
Background/Objectives: Establishing laparoscopic access remains a critical and complication-prone step in minimally invasive surgery. Previous work has shown that proximal vibroacoustic sensing can identify peritoneal puncture events in porcine cadavers. The present pilot study evaluated whether these findings translate to human anatomy under controlled, ex vivo conditions. Methods: A vibroacoustic sensing prototype was proximally attached to a standard Veress needle during 14 insertions into a fresh human body donor (within 48 h post-mortem). An endoscope was introduced laterally to provide visual ground truth of peritoneal entry. Vibroacoustic signals were recorded at the proximal end of the instrument. Time–frequency analyses, transient excitation detection, and statistical comparisons were performed to assess whether (1) peritoneal puncture can be identified in the vibroacoustic signal, (2) signal phases and dynamics correspond to those previously observed in porcine cadavers, and (3) peritoneal punctures can be statistically differentiated from non-peritoneal events. Results: All 14 peritoneal punctures were identifiable in the vibroacoustic signal under the experimental conditions. Characteristic signal phases previously described in porcine tissue, including transient excitation associated with cavity entry, were consistently reproduced with comparable temporal and spectral profiles. Statistical analyses demonstrated group-level differences between peritoneal and non-peritoneal events, and the peritoneal puncture was the highest-energy event of its insertion in 13 of 14 cases (92.9%). Conclusions: Under the controlled ex vivo conditions of this single-donor pilot study, vibroacoustic sensing was feasible for identifying peritoneal puncture in human tissue and reproduced signal dynamics observed in porcine models. To our knowledge, this is the first demonstration of the proximal vibroacoustic sensing concept on a human body donor and the first cross-species replication of the previously reported puncture phase structure, establishing an important translational stepping stone between animal cadaver studies and in vivo investigations. The study demonstrates feasibility rather than clinical reliability: the single-donor design and the retrospective annotation framework limit generalizability. Prospective validation in living patients, across multiple subjects and operators, is required before clinical deployment.
- Open Access
Machine Learning-Based Fluorescence Assessment for Augmented Imaging and Decision Support in Glioblastoma Resections
Background/Objectives: Glioblastoma is the most common and aggressive primary malignant brain tumor in adults, characterized by infiltrative growth and poor prognosis. Achieving maximal resection without inducing neurological deficits remains a challenge in glioblastoma surgery. While 5-aminolevulinic acid-based fluorescence-guided surgery supports intraoperative tumor visualization, its reliability is limited by patient variability and weak fluorescence signals. This study proposes a machine learning framework to enhance fluorescence-guided surgery sensitivity by analyzing surgical microscope images at the pixel level. Methods: Fluorescence-mode neurosurgical microscope images of synthetic samples with known Protoporphyrin IX (PPIX) concentrations were used to train three classifiers (Support Vector Machine, Naïve Bayes, Neural Network) for pixel-wise fluorescence detection. In parallel, three contrastive-learning-based Variational Autoencoders (VAE, = 1, 2, 3) were evaluated for detecting weak fluorescence beyond visual perception. Additionally, a regression model was trained to relate pixel features to PPIX concentration. The best-performing VAE ( = 1) was subsequently trained on real intraoperative data, and its detection sensitivity was compared to annotations from four experienced surgeons. Results: The proposed model achieved the highest detection rates on synthetic test data when calibrated for 99% specificity. Applied to real intraoperative images, the model revealed fluorescent areas substantially larger than those marked by experienced surgeons. In non-5-ALA control cases, minimal false positives were observed, indicating a specificity exceeding 99.9%. The regression model reliably quantified PPIX concentration in synthetic samples (). Conclusions: By enabling more sensitive and objective fluorescence detection, this approach offers a valuable tool for improving surgical decision-making and facilitating safer, more extensive tumor resections.Open AccessMachine Learning-Based Fluorescence Assessment for Augmented Imaging and Decision Support in Glioblastoma Resections
Background/Objectives: Glioblastoma is the most common and aggressive primary malignant brain tumor in adults, characterized by infiltrative growth and poor prognosis. Achieving maximal resection without inducing neurological deficits remains a challenge in glioblastoma surgery. While 5-aminolevulinic acid-based fluorescence-guided surgery supports intraoperative tumor visualization, its reliability is limited by patient variability and weak fluorescence signals. This study proposes a machine learning framework to enhance fluorescence-guided surgery sensitivity by analyzing surgical microscope images at the pixel level. Methods: Fluorescence-mode neurosurgical microscope images of synthetic samples with known Protoporphyrin IX (PPIX) concentrations were used to train three classifiers (Support Vector Machine, Naïve Bayes, Neural Network) for pixel-wise fluorescence detection. In parallel, three contrastive-learning-based Variational Autoencoders (VAE, = 1, 2, 3) were evaluated for detecting weak fluorescence beyond visual perception. Additionally, a regression model was trained to relate pixel features to PPIX concentration. The best-performing VAE ( = 1) was subsequently trained on real intraoperative data, and its detection sensitivity was compared to annotations from four experienced surgeons. Results: The proposed model achieved the highest detection rates on synthetic test data when calibrated for 99% specificity. Applied to real intraoperative images, the model revealed fluorescent areas substantially larger than those marked by experienced surgeons. In non-5-ALA control cases, minimal false positives were observed, indicating a specificity exceeding 99.9%. The regression model reliably quantified PPIX concentration in synthetic samples (). Conclusions: By enabling more sensitive and objective fluorescence detection, this approach offers a valuable tool for improving surgical decision-making and facilitating safer, more extensive tumor resections. - Open Access
- 1 December 2025
- Published by Walter de Gruyter GmbH in Current Directions in Biomedical Engineering
- Vol. 11 (2) , 112-115
Needle Puncture Detection Using Vibroacoustic Sensing in Layered Phantoms
This study evaluates the use of vibroacoustic (VA) sensing to detect material transitions during needle insertions into layered synthetic phantoms. Experiments were conducted using foams with different pore densities and configurations including internal cavities. Time-domain and wavelet analyses showed that denser foams produced more frequent vibrational events, while less dense foams resulted in sparser signals. In setups with elastic membranes and cavities, differences in time-frequency patterns were observed: high-frequency activity appeared after membrane rupture but was absent in cavity insertions. These results support the use of VA sensing to identify mechanical changes during minimally invasive procedures.
- 1 December 2025
- Published by Walter de Gruyter GmbH in Current Directions in Biomedical Engineering
- Vol. 11 (2) , 112-115
Open AccessNeedle Puncture Detection Using Vibroacoustic Sensing in Layered Phantoms
This study evaluates the use of vibroacoustic (VA) sensing to detect material transitions during needle insertions into layered synthetic phantoms. Experiments were conducted using foams with different pore densities and configurations including internal cavities. Time-domain and wavelet analyses showed that denser foams produced more frequent vibrational events, while less dense foams resulted in sparser signals. In setups with elastic membranes and cavities, differences in time-frequency patterns were observed: high-frequency activity appeared after membrane rupture but was absent in cavity insertions. These results support the use of VA sensing to identify mechanical changes during minimally invasive procedures.
- Open Access
- 29 November 2025
- Published by MDPI AG in Diagnostics
- Vol. 15 (23) , 3051
Perpendicular Vascular Changes in NBI-CE of Laryngeal Lesions: Diagnostic Accuracy, Reproducibility, and Common Pitfalls
Background/Objectives: Differentiating benign, premalignant, and early malignant vocal fold lesions is challenging. Perpendicular vascular changes (PVCs) per the European Laryngological Society (ELS) are key malignancy indicators. Enhanced contact endoscopy with narrow-band imaging (NBI-CE) visualizes intrapapillary capillary loops (IPCLs) at high magnification, independent of gross morphology. However, defining malignancy as any PVC increases sensitivity but lowers specificity—particularly in papillomas—whereas limiting malignancy to narrow-angle PVC improves specificity but risks false negatives and reduced reproducibility. Methods: We intraoperatively evaluated 146 histology-proven vocal fold lesions using NBI-CE. Six raters (three experienced otolaryngologists, three PhD students) classified vascular patterns. Two approaches were tested: (1) malignancy = narrow-angle PVC; (2) malignancy = any PVC. Outcomes were accuracy, sensitivity, specificity, and interrater agreement. Results: Approach (1) had higher specificity but lower sensitivity than (2) (~85% vs. ~70% specificity; ~50% vs. ~80% sensitivity). Accuracy did not differ significantly. Experienced raters showed higher interrater agreement and a more favorable sensitivity–specificity balance. Common errors were false positives in papillomas and false negatives in dysplasia/early carcinoma. Conclusions: PVC assessment with NBI-CE is feasible and informative. Choosing between “any PVC” and “narrow-angle only” entails a sensitivity–specificity trade-off and depends on lesion type and experience. Refined ELS descriptors and automated analysis may improve reproducibility and accuracy.
- 29 November 2025
- Published by MDPI AG in Diagnostics
- Vol. 15 (23) , 3051
Open AccessPerpendicular Vascular Changes in NBI-CE of Laryngeal Lesions: Diagnostic Accuracy, Reproducibility, and Common Pitfalls
Background/Objectives: Differentiating benign, premalignant, and early malignant vocal fold lesions is challenging. Perpendicular vascular changes (PVCs) per the European Laryngological Society (ELS) are key malignancy indicators. Enhanced contact endoscopy with narrow-band imaging (NBI-CE) visualizes intrapapillary capillary loops (IPCLs) at high magnification, independent of gross morphology. However, defining malignancy as any PVC increases sensitivity but lowers specificity—particularly in papillomas—whereas limiting malignancy to narrow-angle PVC improves specificity but risks false negatives and reduced reproducibility. Methods: We intraoperatively evaluated 146 histology-proven vocal fold lesions using NBI-CE. Six raters (three experienced otolaryngologists, three PhD students) classified vascular patterns. Two approaches were tested: (1) malignancy = narrow-angle PVC; (2) malignancy = any PVC. Outcomes were accuracy, sensitivity, specificity, and interrater agreement. Results: Approach (1) had higher specificity but lower sensitivity than (2) (~85% vs. ~70% specificity; ~50% vs. ~80% sensitivity). Accuracy did not differ significantly. Experienced raters showed higher interrater agreement and a more favorable sensitivity–specificity balance. Common errors were false positives in papillomas and false negatives in dysplasia/early carcinoma. Conclusions: PVC assessment with NBI-CE is feasible and informative. Choosing between “any PVC” and “narrow-angle only” entails a sensitivity–specificity trade-off and depends on lesion type and experience. Refined ELS descriptors and automated analysis may improve reproducibility and accuracy.
- Open Access
- 11 November 2025
- Published by Springer Nature in Clinical Neuroradiology
- Vol. 36 (2) , 359-367
Feasibility of Using Angioscopy to Visualize the Internal Vessel Wall of the Internal Carotid Artery
Background: Digital subtraction angiography lacks the ability to visualise intimal surface changes. Angioscopy, in contrast, enables direct imaging of the endoluminal surface, revealing luminal alterations, as established in cardiovascular imaging. Its application in the internal carotid artery (ICA) could allow assessment of pathological changes and the visualization of implant structures such as stents or flow diverters, including their apposition to the vessel wall. This study evaluates the feasibility of using a thin fibre-optic endoscope for angioscopy in the ICA anatomy. Methods: Five 3D DSA image sets of the ICA with varying anatomies were selected. Tube-based vessel models were fabricated to replicate the corresponding vascular segments, incorporating a measurement scale and, optionally, a stent or a flow diverter. The advancement of a fibre-optic endoscope and the related influence on vessel deformation were assessed in each model. Spatial and colour resolution were evaluated by applying coloured markings to the inner tube surface to simulate vessel wall discolouration. The visibility of structural details, including flow diverter meshes and stent struts, was assessed based on image contrast and sharpness within the angioscope’s defined field of view. Results: The endoscope was successfully advanced to the distal end in all models. Increased vascular curvature required greater mechanical force for navigation and positioning, leading to observable straightening of the vessel model. In all cases, endoscopic imaging produced clear visualizations of vessel wall markings and implant structures. Stent struts and flow diverter meshes were distinguishable, as were discolorations simulating pathological changes. Conclusion: Angioscopy of the ICA is technically feasible and enables endoluminal visualization, including implant structures. Feasibility was strongly dependent on vessel curvature and required substantial increases in delivery force in highly tortuous anatomies.
- 11 November 2025
- Published by Springer Nature in Clinical Neuroradiology
- Vol. 36 (2) , 359-367
Open AccessFeasibility of Using Angioscopy to Visualize the Internal Vessel Wall of the Internal Carotid Artery
Background: Digital subtraction angiography lacks the ability to visualise intimal surface changes. Angioscopy, in contrast, enables direct imaging of the endoluminal surface, revealing luminal alterations, as established in cardiovascular imaging. Its application in the internal carotid artery (ICA) could allow assessment of pathological changes and the visualization of implant structures such as stents or flow diverters, including their apposition to the vessel wall. This study evaluates the feasibility of using a thin fibre-optic endoscope for angioscopy in the ICA anatomy. Methods: Five 3D DSA image sets of the ICA with varying anatomies were selected. Tube-based vessel models were fabricated to replicate the corresponding vascular segments, incorporating a measurement scale and, optionally, a stent or a flow diverter. The advancement of a fibre-optic endoscope and the related influence on vessel deformation were assessed in each model. Spatial and colour resolution were evaluated by applying coloured markings to the inner tube surface to simulate vessel wall discolouration. The visibility of structural details, including flow diverter meshes and stent struts, was assessed based on image contrast and sharpness within the angioscope’s defined field of view. Results: The endoscope was successfully advanced to the distal end in all models. Increased vascular curvature required greater mechanical force for navigation and positioning, leading to observable straightening of the vessel model. In all cases, endoscopic imaging produced clear visualizations of vessel wall markings and implant structures. Stent struts and flow diverter meshes were distinguishable, as were discolorations simulating pathological changes. Conclusion: Angioscopy of the ICA is technically feasible and enables endoluminal visualization, including implant structures. Feasibility was strongly dependent on vessel curvature and required substantial increases in delivery force in highly tortuous anatomies.
- Open Access
- 4 November 2025
- Published by MDPI AG in Preprints.org
Perpendicular Vascular Changes in NBI-CE of Laryngeal Lesions: Diagnostic Accuracy, Reproducibility, and Common Pitfalls
Background/Objectives: Differentiating benign, premalignant, and early malignant vocal fold lesions is challenging. Perpendicular vascular changes (PVC) per the European Lar-yngological Society (ELS) are key malignancy indicators. Enhanced contact endoscopy with narrow-band imaging (NBI-CE) visualizes intrapapillary capillary loops (IPCLs) at high magnification, independent of gross morphology. However, defining malignancy as any PVC increases sensitivity but lowers specificity—particularly in papillo-mas—whereas limiting malignancy to narrow-angle PVC improves specificity but risks false negatives and reduced reproducibility. Methods: We intraoperatively evaluated 146 histology-proven vocal-fold lesions using NBI-CE. Six raters (three experienced otolaryn-gologists, three PhD students) classified vascular patterns. Two approaches were tested: (1) malignancy = narrow-angle PVC; (2) malignancy = any PVC. Outcomes were accuracy, sensitivity, specificity, and interrater agreement. Results: Approach (1) had higher speci-ficity but lower sensitivity than (2) (~85% vs ~70% specificity; ~50% vs ~80% sensitivity). Accuracy did not differ significantly. Experienced raters showed higher interrater agree-ment and a more favorable sensitivity–specificity balance. Common errors were false pos-itives in papillomas and false negatives in dysplasia/early carcinoma. Conclusions: PVC assessment with NBI-CE is feasible and informative. Choosing between “any PVC” and “narrow-angle only” entails a sensitivity–specificity trade-off and depends on lesion type and experience. Refined ELS descriptors and automated analysis may improve reproduc-ibility and accuracy.
- 4 November 2025
- Published by MDPI AG in Preprints.org
Open AccessPerpendicular Vascular Changes in NBI-CE of Laryngeal Lesions: Diagnostic Accuracy, Reproducibility, and Common Pitfalls
Background/Objectives: Differentiating benign, premalignant, and early malignant vocal fold lesions is challenging. Perpendicular vascular changes (PVC) per the European Lar-yngological Society (ELS) are key malignancy indicators. Enhanced contact endoscopy with narrow-band imaging (NBI-CE) visualizes intrapapillary capillary loops (IPCLs) at high magnification, independent of gross morphology. However, defining malignancy as any PVC increases sensitivity but lowers specificity—particularly in papillo-mas—whereas limiting malignancy to narrow-angle PVC improves specificity but risks false negatives and reduced reproducibility. Methods: We intraoperatively evaluated 146 histology-proven vocal-fold lesions using NBI-CE. Six raters (three experienced otolaryn-gologists, three PhD students) classified vascular patterns. Two approaches were tested: (1) malignancy = narrow-angle PVC; (2) malignancy = any PVC. Outcomes were accuracy, sensitivity, specificity, and interrater agreement. Results: Approach (1) had higher speci-ficity but lower sensitivity than (2) (~85% vs ~70% specificity; ~50% vs ~80% sensitivity). Accuracy did not differ significantly. Experienced raters showed higher interrater agree-ment and a more favorable sensitivity–specificity balance. Common errors were false pos-itives in papillomas and false negatives in dysplasia/early carcinoma. Conclusions: PVC assessment with NBI-CE is feasible and informative. Choosing between “any PVC” and “narrow-angle only” entails a sensitivity–specificity trade-off and depends on lesion type and experience. Refined ELS descriptors and automated analysis may improve reproduc-ibility and accuracy.