Calum Williams
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Calum Williams has a total of 121 co-authors. Here are the top co-authors by number of shared publications:
Timothy D. Wilkinson
Electrical Engineering Division Department of Engineering University of Cambridge 9 JJ Thomson Avenue Cambridge CB3 0FA UK
11 shared publications- Sarah Elizabeth Bohndiek
Cancer Research UK Cambridge Institute (United Kingdom)
9 shared publications - George Sinclair Dukoff Gordon
The University of Nottingham
6 shared publications - Hyun Jung Kim
NASA Langley Research Center, Hampton, USA
6 shared publications Matthew Julian
Booz Allen Hamilton, Arlington, USA
5 shared publications- Girish Rughoobur
MIT, Dept Elect Engn & Comp Sci, 77 Massachusetts Ave, Cambridge, MA 02139 USA
4 shared publications
Latest Publications
- Open Access
- 21 February 2025
- Published by Wiley in Advanced Optical Materials
- Vol. 13 (8)
High‐Transmission Mid‐Infrared Bandpass Filters using Hybrid Metal‐Dielectric Metasurfaces for CO 2 Sensing
Mid‐infrared (MIR) spectroscopy is widely applied in many applications such as gas sensing, industrial inspection, astronomy, and imaging. While thin‐film narrowband interference filters are cost‐effective for MIR sensing, their complex fabrication limits their suitability for miniaturized systems. Plasmonic nanostructures, though explored for MIR applications, suffer from broad spectral responses and low efficiencies due to the ohmic losses inherent in metals. All‐dielectric metasurfaces, with low intrinsic losses, have been proposed as alternatives for MIR spectroscopy. However, their operation is typically limited to reflection mode. In this work, a hybrid metal‐dielectric metasurface operating in transmission mode for MIR spectroscopy is introduced. Composed of germanium (Ge) atop aluminium (Al) cylinders on a calcium fluoride (CaF 2 ) substrate, the metasurface achieves high transmission efficiency (80%) at λ = 2.6 µm and a narrow full‐width‐half‐maximum of 0.4 µm. The transmission response arises due to the hybridization of modes between the Ge and Al structures. Numerical simulations are demonstrated, a straightforward fabrication method, and successful deployment as an in‐line optical filter for CO 2 gas detection, achieving a detection limit of ≈0.04% (≈400 ppm). This work highlights the potential of hybrid metasurfaces as in‐line gas sensing filters in MIR spectroscopy.
- 21 February 2025
- Published by Wiley in Advanced Optical Materials
- Vol. 13 (8)
Open AccessHigh‐Transmission Mid‐Infrared Bandpass Filters using Hybrid Metal‐Dielectric Metasurfaces for CO 2 Sensing
Mid‐infrared (MIR) spectroscopy is widely applied in many applications such as gas sensing, industrial inspection, astronomy, and imaging. While thin‐film narrowband interference filters are cost‐effective for MIR sensing, their complex fabrication limits their suitability for miniaturized systems. Plasmonic nanostructures, though explored for MIR applications, suffer from broad spectral responses and low efficiencies due to the ohmic losses inherent in metals. All‐dielectric metasurfaces, with low intrinsic losses, have been proposed as alternatives for MIR spectroscopy. However, their operation is typically limited to reflection mode. In this work, a hybrid metal‐dielectric metasurface operating in transmission mode for MIR spectroscopy is introduced. Composed of germanium (Ge) atop aluminium (Al) cylinders on a calcium fluoride (CaF 2 ) substrate, the metasurface achieves high transmission efficiency (80%) at λ = 2.6 µm and a narrow full‐width‐half‐maximum of 0.4 µm. The transmission response arises due to the hybridization of modes between the Ge and Al structures. Numerical simulations are demonstrated, a straightforward fabrication method, and successful deployment as an in‐line optical filter for CO 2 gas detection, achieving a detection limit of ≈0.04% (≈400 ppm). This work highlights the potential of hybrid metasurfaces as in‐line gas sensing filters in MIR spectroscopy.
- Open Access
- 26 March 2024
- Published by Springer Nature in npj Microgravity
- Vol. 10 (1) , 1
Author Correction: Versatile spaceborne photonics with chalcogenide phase-change materials
- 26 March 2024
- Published by Springer Nature in npj Microgravity
- Vol. 10 (1) , 1
Open AccessAuthor Correction: Versatile spaceborne photonics with chalcogenide phase-change materials
- 13 March 2024
- Published by SPIE-Intl Soc Optical Eng
- Vol. PC12900, PC1290001
Fast hyperspectral imaging via spectral undersampling using a digital micromirror device architecture
Hyperspectral imaging (HSI) captures spatial and spectral information from a scene. Conventional scanning HSI systems often yield low optical throughput, slow frame rates, large datasets and/or resolution trade-offs. One can exploit spectral compression in applications where spectral information is sparse in some representation and illumination is controllable, like optical endoscopy. This work experimentally demonstrates fast HSI using a compressed sensing architecture involving a programmable illuminator and a fast monochrome camera. We reconstruct the scene’s hypercube, showing high PSNR (up to 39 for 10 measurements). Our versatile implementation offers higher optical throughput, smaller acquisition times and data volumes compared to conventional HSI approaches.
- 13 March 2024
- Published by SPIE-Intl Soc Optical Eng
- Vol. PC12900, PC1290001
Fast hyperspectral imaging via spectral undersampling using a digital micromirror device architecture
Hyperspectral imaging (HSI) captures spatial and spectral information from a scene. Conventional scanning HSI systems often yield low optical throughput, slow frame rates, large datasets and/or resolution trade-offs. One can exploit spectral compression in applications where spectral information is sparse in some representation and illumination is controllable, like optical endoscopy. This work experimentally demonstrates fast HSI using a compressed sensing architecture involving a programmable illuminator and a fast monochrome camera. We reconstruct the scene’s hypercube, showing high PSNR (up to 39 for 10 measurements). Our versatile implementation offers higher optical throughput, smaller acquisition times and data volumes compared to conventional HSI approaches.
- Open Access
- 20 February 2024
- Published by Springer Nature in npj Microgravity
- Vol. 10 (1) , 1-9
Versatile spaceborne photonics with chalcogenide phase-change materials
Recent growth in space systems has seen increasing capabilities packed into smaller and lighter Earth observation and deep space mission spacecraft. Phase-change materials (PCMs) are nonvolatile, reconfigurable, fast-switching, and have recently shown a high degree of space radiation tolerance, thereby making them an attractive materials platform for spaceborne photonics applications. They promise robust, lightweight, and energy-efficient reconfigurable optical systems whose functions can be dynamically defined on-demand and on-orbit to deliver enhanced science or mission support in harsh environments on lean power budgets. This comment aims to discuss the recent advances in rapidly growing PCM research and its potential to transition from conventional terrestrial optoelectronics materials platforms to versatile spaceborne photonic materials platforms for current and next-generation space and science missions. Materials International Space Station Experiment-14 (MISSE-14) mission-flown PCMs outside of the International Space Station (ISS) and key results and NASA examples are highlighted to provide strong evidence of the applicability of spaceborne photonics.
- 20 February 2024
- Published by Springer Nature in npj Microgravity
- Vol. 10 (1) , 1-9
Open AccessVersatile spaceborne photonics with chalcogenide phase-change materials
Recent growth in space systems has seen increasing capabilities packed into smaller and lighter Earth observation and deep space mission spacecraft. Phase-change materials (PCMs) are nonvolatile, reconfigurable, fast-switching, and have recently shown a high degree of space radiation tolerance, thereby making them an attractive materials platform for spaceborne photonics applications. They promise robust, lightweight, and energy-efficient reconfigurable optical systems whose functions can be dynamically defined on-demand and on-orbit to deliver enhanced science or mission support in harsh environments on lean power budgets. This comment aims to discuss the recent advances in rapidly growing PCM research and its potential to transition from conventional terrestrial optoelectronics materials platforms to versatile spaceborne photonic materials platforms for current and next-generation space and science missions. Materials International Space Station Experiment-14 (MISSE-14) mission-flown PCMs outside of the International Space Station (ISS) and key results and NASA examples are highlighted to provide strong evidence of the applicability of spaceborne photonics.
- 15 June 2023
- Published by SPIE-Intl Soc Optical Eng
- Vol. PC12514, PC1251403
P-ACTIVE (PCM-based actively tunable filter) project at NASA
Phase change material (PCM)-based actively tunable mid-wave IR filters have broad imaging and sensing applications—from probing molecular vibrations in chemical species to detecting radiant thermal signatures. We introduce the Phase-change actively tunable filter (P-ACTIVE) project lead by NASA Langley Research Center with collaborators MIT and the University of Cambridge. It covers background science, experimental and theoretical device performance, as well as recent results obtained from a MISSE-14 mission for space qualification of active metasurface optics and constituent PCM. We conclude with a prospective view of the technology and discuss the potential for these filters to serve multiple NASA missions.
- 15 June 2023
- Published by SPIE-Intl Soc Optical Eng
- Vol. PC12514, PC1251403
P-ACTIVE (PCM-based actively tunable filter) project at NASA
Phase change material (PCM)-based actively tunable mid-wave IR filters have broad imaging and sensing applications—from probing molecular vibrations in chemical species to detecting radiant thermal signatures. We introduce the Phase-change actively tunable filter (P-ACTIVE) project lead by NASA Langley Research Center with collaborators MIT and the University of Cambridge. It covers background science, experimental and theoretical device performance, as well as recent results obtained from a MISSE-14 mission for space qualification of active metasurface optics and constituent PCM. We conclude with a prospective view of the technology and discuss the potential for these filters to serve multiple NASA missions.
- 15 June 2023
- Published by SPIE-Intl Soc Optical Eng
- Vol. PC12514, PC125140A
Dynamic light shaping using active optical metasurfaces
Optical metasurfaces are planar subwavelength nanoantenna arrays engineered to provide on-demand manipulation of light, thereby enabling ultra-compact flat optics with high performance, small form-factor and new functionalities. When integrated with active elements, the pixelated, thin device architecture further facilitates dynamic tuning of local and global optical responses. Leveraging advanced materials, designs and architectures, we develop novel active and passive meta-optics capable of transforming a variety of optical systems that are traditionally bulky and complicated.
- 15 June 2023
- Published by SPIE-Intl Soc Optical Eng
- Vol. PC12514, PC125140A
Dynamic light shaping using active optical metasurfaces
Optical metasurfaces are planar subwavelength nanoantenna arrays engineered to provide on-demand manipulation of light, thereby enabling ultra-compact flat optics with high performance, small form-factor and new functionalities. When integrated with active elements, the pixelated, thin device architecture further facilitates dynamic tuning of local and global optical responses. Leveraging advanced materials, designs and architectures, we develop novel active and passive meta-optics capable of transforming a variety of optical systems that are traditionally bulky and complicated.
- 6 March 2023
- Published by SPIE-Intl Soc Optical Eng
- Vol. PC12373, PC1237305
Broadband hyperspectral imaging across visible and infrared biological windows using a single camera (Conference Presentation)
Current broadband hyperspectral imaging systems typically require 2 or more camera types (e.g. Si, InGaAs) to achieve high sensitivity in the wavelength range of 400 – 1700 nm. Given the tissue contrast available in this range, creating a compact real-time imaging system that could be deployed in the clinic would be advantageous. Here, we used a state-of-the-art camera based on the Sony SenSWIR image sensor that displays high sensitivity across the VIS-NIR-SWIR to create a broadband hyperspectral imaging system. After camera calibration, we acquired broadband spectra from patient specimens, demonstrating the ability to collect high quality spectra from biological tissues.
- 6 March 2023
- Published by SPIE-Intl Soc Optical Eng
- Vol. PC12373, PC1237305
Broadband hyperspectral imaging across visible and infrared biological windows using a single camera (Conference Presentation)
Current broadband hyperspectral imaging systems typically require 2 or more camera types (e.g. Si, InGaAs) to achieve high sensitivity in the wavelength range of 400 – 1700 nm. Given the tissue contrast available in this range, creating a compact real-time imaging system that could be deployed in the clinic would be advantageous. Here, we used a state-of-the-art camera based on the Sony SenSWIR image sensor that displays high sensitivity across the VIS-NIR-SWIR to create a broadband hyperspectral imaging system. After camera calibration, we acquired broadband spectra from patient specimens, demonstrating the ability to collect high quality spectra from biological tissues.
- 30 December 2022
- Published by SPIE-Intl Soc Optical Eng
- Vol. 12316, 14-20
Resolution-enhanced imaging for endoscopy using diffractive optics
Optical endoscopy is indispensable for minimally-invasive medical diagnostics and therapeutics, whereby visualization of subtle changes in the structure of tissue can be used to identify disease. Adaptive real-time zoom functionality is highly desirable for resolving mucosal microvasculature, which when visualized can be used to improve diagnostic accuracy. Realizing this functionality in state-of-the-art miniaturized endoscopic imaging, such as chip-on-tip endoscopes, is challenging: conventional zoom objectives are bulky and existing chip-on-tip systems still have far from diffraction-limited performance. Point-scanning illumination approaches have been shown to improve imaging resolution by reducing the focused spot size. Typically, this higher resolution comes at the cost of low optical throughput (efficiency) and long acquisition times due to mechanical scanning requirements, thereby limiting applicability in clinical settings. In this work, we demonstrate an innovative Diffractive Optical Element (DOE) based optical imaging system for spatial resolution enhancement without mechanical scanning. Our imaging system is based on simultaneous utilization of a custom DOE and high-speed Digital Micromirror Device (DMD). The multi-level phase-only DOE produces a single super-resolution spot in the far-field while the DMD laterally scans the spot in the object plane at kHz rates. To demonstrate resolution enhancement with high-speed acquisition, we image a resolution test target and fluorescently labelled cells. In the future, through envisioned DOE-array integration in an endoscopic module, resolution enhancement (in an adaptive zoom-mode) can be achieved through illumination modulation alone without the need for separate systems.
- 30 December 2022
- Published by SPIE-Intl Soc Optical Eng
- Vol. 12316, 14-20
Resolution-enhanced imaging for endoscopy using diffractive optics
Optical endoscopy is indispensable for minimally-invasive medical diagnostics and therapeutics, whereby visualization of subtle changes in the structure of tissue can be used to identify disease. Adaptive real-time zoom functionality is highly desirable for resolving mucosal microvasculature, which when visualized can be used to improve diagnostic accuracy. Realizing this functionality in state-of-the-art miniaturized endoscopic imaging, such as chip-on-tip endoscopes, is challenging: conventional zoom objectives are bulky and existing chip-on-tip systems still have far from diffraction-limited performance. Point-scanning illumination approaches have been shown to improve imaging resolution by reducing the focused spot size. Typically, this higher resolution comes at the cost of low optical throughput (efficiency) and long acquisition times due to mechanical scanning requirements, thereby limiting applicability in clinical settings. In this work, we demonstrate an innovative Diffractive Optical Element (DOE) based optical imaging system for spatial resolution enhancement without mechanical scanning. Our imaging system is based on simultaneous utilization of a custom DOE and high-speed Digital Micromirror Device (DMD). The multi-level phase-only DOE produces a single super-resolution spot in the far-field while the DMD laterally scans the spot in the object plane at kHz rates. To demonstrate resolution enhancement with high-speed acquisition, we image a resolution test target and fluorescently labelled cells. In the future, through envisioned DOE-array integration in an endoscopic module, resolution enhancement (in an adaptive zoom-mode) can be achieved through illumination modulation alone without the need for separate systems.
- Open Access
- 12 December 2022
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 27 (12) , 126002-15
Multispectral imaging of nailfold capillaries using light-emitting diode illumination
Nailfold capillaroscopy is a noninvasive imaging modality used to evaluate nailfold capillary morphology and pathological changes of the finger.1 Capillaroscopy aids the clinical diagnosis and monitoring of rheumatological diseases, such as systemic sclerosis (SSc), also known as scleroderma.2 In particular, capillaroscopy forms part of the classification criteria used to diagnosis SSc.3 Video capillaroscopy, which is the gold standard in nailfold capillaroscopy, combines an optical microscope and digital camera to magnify the capillaries so that clinicians can accurately measure their morphology to assess abnormality (e.g., enlarged capillaries and decreased density),4 – 6 yet it fails to reveal the functional changes associated with capillary deformations.1,7 Microvascular deformation observed at the nailfold in SSc is hypothesized to arise due to hypoxia, but this has proven difficult to measure. Low oxygen is theorized to be a key element of the disease process; superficial skin changes are thought to mirror underlying changes occurring in internal organs.8 Understanding how blood oxygen saturation is related to microvascular deformation, and the role it plays in the development and progression of connective tissue disorders could improve disease diagnosis, monitoring, and treatment.9,10
- 12 December 2022
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 27 (12) , 126002-15
Open AccessMultispectral imaging of nailfold capillaries using light-emitting diode illumination
Nailfold capillaroscopy is a noninvasive imaging modality used to evaluate nailfold capillary morphology and pathological changes of the finger.1 Capillaroscopy aids the clinical diagnosis and monitoring of rheumatological diseases, such as systemic sclerosis (SSc), also known as scleroderma.2 In particular, capillaroscopy forms part of the classification criteria used to diagnosis SSc.3 Video capillaroscopy, which is the gold standard in nailfold capillaroscopy, combines an optical microscope and digital camera to magnify the capillaries so that clinicians can accurately measure their morphology to assess abnormality (e.g., enlarged capillaries and decreased density),4 – 6 yet it fails to reveal the functional changes associated with capillary deformations.1,7 Microvascular deformation observed at the nailfold in SSc is hypothesized to arise due to hypoxia, but this has proven difficult to measure. Low oxygen is theorized to be a key element of the disease process; superficial skin changes are thought to mirror underlying changes occurring in internal organs.8 Understanding how blood oxygen saturation is related to microvascular deformation, and the role it plays in the development and progression of connective tissue disorders could improve disease diagnosis, monitoring, and treatment.9,10
- Open Access
- 10 June 2022
- Published by Wiley in Nanophotonics
- Vol. 11 (17) , 4149-4158
Deep neural network enabled active metasurface embedded design
In this paper, we propose a deep learning approach for forward modeling and inverse design of photonic devices containing embedded active metasurface structures. In particular, we demonstrate that combining neural network design of metasurfaces with scattering matrix‐based optimization significantly simplifies the computational overhead while facilitating accurate objective‐driven design. As an example, we apply our approach to the design of a continuously tunable bandpass filter in the mid‐wave infrared, featuring narrow passband (∼10 nm), high quality factors ( Q ‐factors ∼ 10 2 ), and large out‐of‐band rejection (optical density ≥ 3). The design consists of an optical phase‐change material Ge 2 Sb 2 Se 4 Te (GSST) metasurface atop a silicon heater sandwiched between two distributed Bragg reflectors (DBRs). The proposed design approach can be generalized to the modeling and inverse design of arbitrary response photonic devices incorporating active metasurfaces.
- 10 June 2022
- Published by Wiley in Nanophotonics
- Vol. 11 (17) , 4149-4158
Open AccessDeep neural network enabled active metasurface embedded design
In this paper, we propose a deep learning approach for forward modeling and inverse design of photonic devices containing embedded active metasurface structures. In particular, we demonstrate that combining neural network design of metasurfaces with scattering matrix‐based optimization significantly simplifies the computational overhead while facilitating accurate objective‐driven design. As an example, we apply our approach to the design of a continuously tunable bandpass filter in the mid‐wave infrared, featuring narrow passband (∼10 nm), high quality factors ( Q ‐factors ∼ 10 2 ), and large out‐of‐band rejection (optical density ≥ 3). The design consists of an optical phase‐change material Ge 2 Sb 2 Se 4 Te (GSST) metasurface atop a silicon heater sandwiched between two distributed Bragg reflectors (DBRs). The proposed design approach can be generalized to the modeling and inverse design of arbitrary response photonic devices incorporating active metasurfaces.