Klaus Boening
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Klaus Boening has a total of 37 co-authors. Here are the top co-authors by number of shared publications:
- Mieszko Wieckiewicz
Department of Experimental Dentistry, Wroclaw Medical University, 50-425 Wroclaw, Poland
10 shared publications - Heike Meissner
Department of Prosthodontics, Carl Gustav Carus Faculty of Medicine, Dresden University of Technology, Germany
7 shared publications - Katarzyna Kresse-Walczak
Section for Prosthetic Dentistry, Department of Dentistry and Oral Health, Aarhus University, Denmark
4 shared publications - Katarzyna Walczak
Department of Prosthetic Dentistry, Carl Gustav Carus Faculty of Medicine, Technische Universität Dresden, Fetscherstr. 74, 01307 Dresden, Germany
3 shared publications - Anna Paradowska-Stolarz
Division of Dentofacial Anomalies, Department of Orthodontics and Dentofacial Orthopedics, Wroclaw Medical University, Krakowska 26, 50-425 Wroclaw, Poland
2 shared publications - Elisabeth Prause
Department of Prosthodontics, Geriatric Dentistry and Craniomandibular Disorders, Charité-Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt-Universität Zu Berlin, Berlin, Germany
2 shared publications
Latest Publications
- Open Access
- 27 February 2026
- Published by Wroclaw Medical University in Dental and Medical Problems
- Vol. 63 (1) , 179-187
Influence of thermal aging on surface roughness of conventional and 3D-printed materials used in intraoral appliance manufacturing
Intraoral appliances are widely used in dentistry. Their surface roughness may influence patient comfort, biofilm formation and durability. The aim of the study was to evaluate and compare the effect of thermocycling on the surface roughness (Ra) of different materials used for the fabrication of intraoral appliances. Seventy-two standardized specimens (40 mm × 10 mm × 2 mm) were fabricated from 3 materials: a self-curing poly(methyl methacrylate) (PMMA) resin (PMMA group); a light-cured urethane dimethacrylate (UDMA)-based resin (UDMA group); and a stereolithography (SLA) 3D-printed resin (SLA group). Surface roughness was measured before and after thermocycling (5,000 and 10,000 cycles between 5°C and 55°C) using a contact profilometer. Values were reported as mean (M) ±standard deviation (SD). The data was analyzed using repeated-measures or ordinary one-way analysis of variance (ANOVA), followed by Bonferroni-corrected post hoc tests (α = 0.0167). The UDMA group exhibited the lowest mean initial Ra values (0.078 ±0.020 μm). Thermocycling induced changes in surface roughness. In the PMMA group, a significant increase in mean Ra was observed after 5,000 cycles (0.103 ±0.028 μm before vs. 0.167 ±0.059 μm after; p = 0.0001) and after 10,000 cycles (0.107 ±0.024 μm before vs. 0.205 ±0.060 μm after; p < 0.0001). The increase in mean Ra following thermocycling was significantly greater in the PMMA group compared to the other groups (mean ΔRa after 5,000 cycles: 0.064 ±0.035 μm; after 10,000 cycles: 0.098 ±0.046 μm; all p < 0.0001). Materials used for the fabrication of intraoral appliances exhibit material-specific responses to thermal aging. The light-cured UDMA-based resin demonstrated superior surface integrity after aging, whereas conventional PMMA and the 3D-printed resin were more susceptible to surface alterations.
- 27 February 2026
- Published by Wroclaw Medical University in Dental and Medical Problems
- Vol. 63 (1) , 179-187
Open AccessInfluence of thermal aging on surface roughness of conventional and 3D-printed materials used in intraoral appliance manufacturing
Intraoral appliances are widely used in dentistry. Their surface roughness may influence patient comfort, biofilm formation and durability. The aim of the study was to evaluate and compare the effect of thermocycling on the surface roughness (Ra) of different materials used for the fabrication of intraoral appliances. Seventy-two standardized specimens (40 mm × 10 mm × 2 mm) were fabricated from 3 materials: a self-curing poly(methyl methacrylate) (PMMA) resin (PMMA group); a light-cured urethane dimethacrylate (UDMA)-based resin (UDMA group); and a stereolithography (SLA) 3D-printed resin (SLA group). Surface roughness was measured before and after thermocycling (5,000 and 10,000 cycles between 5°C and 55°C) using a contact profilometer. Values were reported as mean (M) ±standard deviation (SD). The data was analyzed using repeated-measures or ordinary one-way analysis of variance (ANOVA), followed by Bonferroni-corrected post hoc tests (α = 0.0167). The UDMA group exhibited the lowest mean initial Ra values (0.078 ±0.020 μm). Thermocycling induced changes in surface roughness. In the PMMA group, a significant increase in mean Ra was observed after 5,000 cycles (0.103 ±0.028 μm before vs. 0.167 ±0.059 μm after; p = 0.0001) and after 10,000 cycles (0.107 ±0.024 μm before vs. 0.205 ±0.060 μm after; p < 0.0001). The increase in mean Ra following thermocycling was significantly greater in the PMMA group compared to the other groups (mean ΔRa after 5,000 cycles: 0.064 ±0.035 μm; after 10,000 cycles: 0.098 ±0.046 μm; all p < 0.0001). Materials used for the fabrication of intraoral appliances exhibit material-specific responses to thermal aging. The light-cured UDMA-based resin demonstrated superior surface integrity after aging, whereas conventional PMMA and the 3D-printed resin were more susceptible to surface alterations.
- Open Access
The Influence of Thermal and Mechanical Aging on the Flexural Properties of Conventional and 3D-Printed Materials Used in Occlusal Splints Manufacturing
Occlusal splints are a type of intraoral appliance that are widely used for the management of temporomandibular disorders and bruxism, yet limited evidence exists regarding the comparative effects of combined aging on conventional and digitally manufactured materials. This in vitro study evaluated the influence of thermal and mechanical aging on the flexural properties of three materials commonly used for the manufacturing of occlusal devices: self-curing poly(methyl methacrylate) (PMMA, control), light-cured urethane dimethacrylate (UDMA)-based resin, and stereolithography (SLA)-printed photopolymer. Seventy-two standardized specimens (n = 24 per material; 64 × 10 × 3.3 mm) were fabricated, then randomly allocated to three groups (n = 8): control, thermocycling (10,000 cycles, 5 °C/55 °C), and combined thermocycling with mechanical loading (1000 cycles). Flexural strength and modulus were determined by three-point bending tests and analyzed using a two-way analysis of variance (ANOVA) with Tukey’s post hoc test (α = 0.05). Thermocycling significantly reduced flexural strength in PMMA (65.19 ± 6.68 to 57.94 ± 7.15 MPa) and SLA (67.67 ± 1.54 to 59.37 ± 8.80 MPa) groups (p < 0.05), while UDMA group (45.489 ± 3.905 to 43.123 ± 4.367 MPa) demonstrated no significant changes (p ≥ 0.05). UDMA exhibited substantially and significantly lower flexural properties compared to PMMA and SLA across all conditions (p < 0.0001). Thermal aging slightly compromises the mechanical properties of PMMA and SLA-printed materials, whereas UDMA-based resins exhibit good aging resistance but considerably lower initial values. While UDMA-based resin showed superior aging resistance, its lower baseline mechanical properties may limit its application in high-stress clinical scenarios compared to PMMA and SLA-printed materials. Material selection should consider both initial properties and long-term environmental changes.
Open AccessThe Influence of Thermal and Mechanical Aging on the Flexural Properties of Conventional and 3D-Printed Materials Used in Occlusal Splints Manufacturing
Occlusal splints are a type of intraoral appliance that are widely used for the management of temporomandibular disorders and bruxism, yet limited evidence exists regarding the comparative effects of combined aging on conventional and digitally manufactured materials. This in vitro study evaluated the influence of thermal and mechanical aging on the flexural properties of three materials commonly used for the manufacturing of occlusal devices: self-curing poly(methyl methacrylate) (PMMA, control), light-cured urethane dimethacrylate (UDMA)-based resin, and stereolithography (SLA)-printed photopolymer. Seventy-two standardized specimens (n = 24 per material; 64 × 10 × 3.3 mm) were fabricated, then randomly allocated to three groups (n = 8): control, thermocycling (10,000 cycles, 5 °C/55 °C), and combined thermocycling with mechanical loading (1000 cycles). Flexural strength and modulus were determined by three-point bending tests and analyzed using a two-way analysis of variance (ANOVA) with Tukey’s post hoc test (α = 0.05). Thermocycling significantly reduced flexural strength in PMMA (65.19 ± 6.68 to 57.94 ± 7.15 MPa) and SLA (67.67 ± 1.54 to 59.37 ± 8.80 MPa) groups (p < 0.05), while UDMA group (45.489 ± 3.905 to 43.123 ± 4.367 MPa) demonstrated no significant changes (p ≥ 0.05). UDMA exhibited substantially and significantly lower flexural properties compared to PMMA and SLA across all conditions (p < 0.0001). Thermal aging slightly compromises the mechanical properties of PMMA and SLA-printed materials, whereas UDMA-based resins exhibit good aging resistance but considerably lower initial values. While UDMA-based resin showed superior aging resistance, its lower baseline mechanical properties may limit its application in high-stress clinical scenarios compared to PMMA and SLA-printed materials. Material selection should consider both initial properties and long-term environmental changes.
- Open Access
- 31 October 2024
- Published by Wroclaw Medical University in Dental and Medical Problems
- Vol. 61 (5) , 729-738
Mechanical, optical and surface properties of 3D-printed and conventionally processed polyamide 12
Background. Polyamide-based materials are suitable for three-dimensional (3D) printing. Objectives. The aim of the study is to examine the impact of aging on the mechanical, surface and optical properties of polyamide 12. Material and methods. A total of 116 specimens were examined, comprising 58 conventionally processed polyamide 12 (PA12_C) specimens and 58 3D-printed polyamide 12 (PA12_3D) specimens. The modulus of elasticity was determined before and after mechanical and thermal aging with 1,000, 3,000, 9,000, and 1,000, 3,000 and 7,000 cycles, respectively. The surface roughness (Ra), Ra change (ARa) and color change (AE) were examined before and after chemical aging (1, 12 and 36 days, with artificial saliva, coffee and red wine) using surface profilometryand color spectroscopy. The Kruskal-Wallis test, Mann-Whitney U test and Bonferroni-Holm correction were employed, with a significance level of p < 0.05. Results. Before and after mechanical aging, the modulus of elasticity for PA12_3D showed significantly higher values (761 MPa and 747 MPa, respectively) in comparison to PA12_C (515 MPa and 455 MPa, respectively; adjusted p < 0.001). Additionally, before and after thermal aging, the modulus of elasticity for PA12_3D exhibited significantly higher values (833 MPa and 705 MPa, respectively) compared to PA12_C (516 MPa and 458 MPa, respectively; adjusted p < 0.001). The Ra of PA12_3D was higher than that of PA12_C at the baseline (0.41 m compared to 0.31 mu m, respectively), and remained higher during the aging process. The ARa values were small for both groups. The AE was significantly higher for PA12_3D compared to PA12_C after 12 days (6.2 (PA12_3D) compared to 4.8 (PA12_C), adjusted p = 0.003) and 36 days of storage in red wine (8.2 (PA12_3D) compared to 6.8 (PA12_C), adjusted p = 0.003). After 36 days of coffee storage, the observed changes were found to be statistically significant (8.6 (PA12_3D) compared to 6.7 (PA12_C), adjusted p < 0.001). Conclusions. The 3D-printed polyamide 12 demonstrated higher rigidity, Ra and discoloration compared to the conventionally processed polyamide 12. However, not all of the observed parameter differences were significant or clinically relevant. These differences may impact clasp retention, biofilm formation and aesthetic appearance. Nevertheless, the clinical efficacy of 3D printing may be significant.
- 31 October 2024
- Published by Wroclaw Medical University in Dental and Medical Problems
- Vol. 61 (5) , 729-738
Open AccessMechanical, optical and surface properties of 3D-printed and conventionally processed polyamide 12
Background. Polyamide-based materials are suitable for three-dimensional (3D) printing. Objectives. The aim of the study is to examine the impact of aging on the mechanical, surface and optical properties of polyamide 12. Material and methods. A total of 116 specimens were examined, comprising 58 conventionally processed polyamide 12 (PA12_C) specimens and 58 3D-printed polyamide 12 (PA12_3D) specimens. The modulus of elasticity was determined before and after mechanical and thermal aging with 1,000, 3,000, 9,000, and 1,000, 3,000 and 7,000 cycles, respectively. The surface roughness (Ra), Ra change (ARa) and color change (AE) were examined before and after chemical aging (1, 12 and 36 days, with artificial saliva, coffee and red wine) using surface profilometryand color spectroscopy. The Kruskal-Wallis test, Mann-Whitney U test and Bonferroni-Holm correction were employed, with a significance level of p < 0.05. Results. Before and after mechanical aging, the modulus of elasticity for PA12_3D showed significantly higher values (761 MPa and 747 MPa, respectively) in comparison to PA12_C (515 MPa and 455 MPa, respectively; adjusted p < 0.001). Additionally, before and after thermal aging, the modulus of elasticity for PA12_3D exhibited significantly higher values (833 MPa and 705 MPa, respectively) compared to PA12_C (516 MPa and 458 MPa, respectively; adjusted p < 0.001). The Ra of PA12_3D was higher than that of PA12_C at the baseline (0.41 m compared to 0.31 mu m, respectively), and remained higher during the aging process. The ARa values were small for both groups. The AE was significantly higher for PA12_3D compared to PA12_C after 12 days (6.2 (PA12_3D) compared to 4.8 (PA12_C), adjusted p = 0.003) and 36 days of storage in red wine (8.2 (PA12_3D) compared to 6.8 (PA12_C), adjusted p = 0.003). After 36 days of coffee storage, the observed changes were found to be statistically significant (8.6 (PA12_3D) compared to 6.7 (PA12_C), adjusted p < 0.001). Conclusions. The 3D-printed polyamide 12 demonstrated higher rigidity, Ra and discoloration compared to the conventionally processed polyamide 12. However, not all of the observed parameter differences were significant or clinically relevant. These differences may impact clasp retention, biofilm formation and aesthetic appearance. Nevertheless, the clinical efficacy of 3D printing may be significant.
- Open Access
- 26 January 2024
- Published by MDPI AG in Dentistry Journal
- Vol. 12 (2) , 24
Visual Versus Digital Color Determination of 3D-Printed Teeth as an Exercise in Dental Students’ Education
Visual color determination is part of the daily routine in dental practice. However, it is not a part of dental education so far. The aim of this study was to evaluate whether visual or digital tooth color determination of 3D-printed teeth is a reliable tool for inexperienced dentistry students. Preclinical dental students evaluated eleven 3D-printed, tooth-shaped samples (VarseoSmile Crown plus, BEGO, Bremen, Germany) of different color shades. Visual shade determination using a reference scale (3D-Master Toothguide (3DM_TG), VITA Zahnfabrik, Bad Säckingen, Germany), followed by a digital color determination using a spectrophotometer (VITA Easyshade V, (ES_V), VITA Zahnfabrik), was performed. Color deviation was calculated in the Lab* color space (ΔE00) and converted into CIELAB 2000. The results were evaluated using the Mann–Whitney U test and the Wilcoxon Rank Sum test (α = 0.05). Significant differences between visual and digital color determination were proven (p < 0.001). Visual color determination (3DM_TG) showed a mean deviation (ΔE00 ± 95%CI) of 6.49 ± 0.47. Digital color determination (ES_V) showed significantly lower mean deviations of ΔE00 of 1.44 ± 0.58. Digital tooth color measurement using a spectrophotometer was a more reliable tool for the color determination of 3D-printed teeth for inexperienced dentistry students.
- 26 January 2024
- Published by MDPI AG in Dentistry Journal
- Vol. 12 (2) , 24
Open AccessVisual Versus Digital Color Determination of 3D-Printed Teeth as an Exercise in Dental Students’ Education
Visual color determination is part of the daily routine in dental practice. However, it is not a part of dental education so far. The aim of this study was to evaluate whether visual or digital tooth color determination of 3D-printed teeth is a reliable tool for inexperienced dentistry students. Preclinical dental students evaluated eleven 3D-printed, tooth-shaped samples (VarseoSmile Crown plus, BEGO, Bremen, Germany) of different color shades. Visual shade determination using a reference scale (3D-Master Toothguide (3DM_TG), VITA Zahnfabrik, Bad Säckingen, Germany), followed by a digital color determination using a spectrophotometer (VITA Easyshade V, (ES_V), VITA Zahnfabrik), was performed. Color deviation was calculated in the Lab* color space (ΔE00) and converted into CIELAB 2000. The results were evaluated using the Mann–Whitney U test and the Wilcoxon Rank Sum test (α = 0.05). Significant differences between visual and digital color determination were proven (p < 0.001). Visual color determination (3DM_TG) showed a mean deviation (ΔE00 ± 95%CI) of 6.49 ± 0.47. Digital color determination (ES_V) showed significantly lower mean deviations of ΔE00 of 1.44 ± 0.58. Digital tooth color measurement using a spectrophotometer was a more reliable tool for the color determination of 3D-printed teeth for inexperienced dentistry students.
- Open Access
- 29 November 2023
- Published by MDPI AG in Dentistry Journal
- Vol. 11 (12) , 275
Visual Tooth Color Determination with Different Reference Scales as an Exercise in Dental Students’ Education
Visual color determination (VCD) requires color competence and individual training. The aim of this study was to evaluate the deviations in students’ VCD with two different reference scales. The research hypothesis was that none of the color references would provide a better result. Participants evaluated nine templates randomly using two reference scales (VITA-classical (VC) and 3D-Master-Toothguide (3DM_TG)). The color distance to the chosen color (ΔEab) was calculated in the CIELAB 2000. The sum’s changes in the parameters (LCh°) represented the target variable. Results were evaluated with non-parametric, rank-scaled methods, utilizing the median with a 25%-75% quartile. The significance level (α = 0.05) is determined using the Student’s t-test. The mean ± 95%CI (SD) was −1.27 ± −1.09 (3.18); the median ΔE00 was −1.49 (−1.97; 0.96) for dC3DM_TG. The determination with VC showed noticeable differences (dCVC), with a mean ΔE00 of 0.00 ± 0.00 (2.20) and a median ΔE00 of 0.00 (1.17; 1.71). The standard error was 0.19 for the dCVC and 0.27 for the dC3DM_TG. dC3DM_TG vs. dCVC showed significant differences at p < 0.001. The dental student’s VCD resulted in color deviations, regardless of the reference template used. The color deviations in hue and chroma were comparable, regardless of the reference scale. VCD’s early implementation in dental education is useful to avoid shade misjudgments and potentially expensive remakes of dentures.
- 29 November 2023
- Published by MDPI AG in Dentistry Journal
- Vol. 11 (12) , 275
Open AccessVisual Tooth Color Determination with Different Reference Scales as an Exercise in Dental Students’ Education
Visual color determination (VCD) requires color competence and individual training. The aim of this study was to evaluate the deviations in students’ VCD with two different reference scales. The research hypothesis was that none of the color references would provide a better result. Participants evaluated nine templates randomly using two reference scales (VITA-classical (VC) and 3D-Master-Toothguide (3DM_TG)). The color distance to the chosen color (ΔEab) was calculated in the CIELAB 2000. The sum’s changes in the parameters (LCh°) represented the target variable. Results were evaluated with non-parametric, rank-scaled methods, utilizing the median with a 25%-75% quartile. The significance level (α = 0.05) is determined using the Student’s t-test. The mean ± 95%CI (SD) was −1.27 ± −1.09 (3.18); the median ΔE00 was −1.49 (−1.97; 0.96) for dC3DM_TG. The determination with VC showed noticeable differences (dCVC), with a mean ΔE00 of 0.00 ± 0.00 (2.20) and a median ΔE00 of 0.00 (1.17; 1.71). The standard error was 0.19 for the dCVC and 0.27 for the dC3DM_TG. dC3DM_TG vs. dCVC showed significant differences at p < 0.001. The dental student’s VCD resulted in color deviations, regardless of the reference template used. The color deviations in hue and chroma were comparable, regardless of the reference scale. VCD’s early implementation in dental education is useful to avoid shade misjudgments and potentially expensive remakes of dentures.
- Open Access
- 4 September 2023
- Published by Wiley in Gerodontology
- Vol. 41 (3) , 368-375
Evaluation of a protocol to assess a novel artificial biofilm equivalent for dentures—A prospective clinical pilot study
Objectives: This pilot study aimed to carry out preliminary tests of the removability of an artificial biofilm equivalent (ABE) and to verify the reproducibility of the ABE testing protocol for a planned main study.Background: There is a lack of data to develop suitable artificial biofilm substitutes, which may be helpful to perform denture hygiene education and to carry out in vitro examinations of oral hygiene products.Materials and Methods: This single‐group, prospective, longitudinal, interventional pilot study was conducted in Dresden (Germany) from February until December 2020. Participants were recruited who wore fully functional upper complete dentures. Denture biofilm was grown on acrylic specimens by wearing dentures for 12 h and 36 h using intraoral appliances. Acrylic specimens were coated with ABEs of three compositions: chitosan (ChS) 0.3 g, methylcellulose (MC) 1.7 g; ChS 0.2 g, MC 1.8 g; ChS 0.1 g, MC 1.9 g (labelled 1.7MC, 1.8MC and 1.9MC, respectively). All specimens underwent standardised mechanical brushing. The percentages of remaining biofilm (POB) were measured.Results: Thirty‐one participants were prescreened, and eight (26%) were included. The appliances were well tolerated, and biofilm was collected. ABE was prepared and brushed as planned. Three and six brushing strokes were needed to remove 12‐h and 36‐h natural denture biofilm, respectively. Correspondingly, three brushing strokes were needed to remove 1.9MC ABE and six brushing strokes to remove 1.8MC and 1.7MC ABE. A reproducibility of ABE removal was indicated.Conclusion: The removability of ABE and the ABE testing protocol were feasible and reproducible for conducting the future main study.
- 4 September 2023
- Published by Wiley in Gerodontology
- Vol. 41 (3) , 368-375
Open AccessEvaluation of a protocol to assess a novel artificial biofilm equivalent for dentures—A prospective clinical pilot study
Objectives: This pilot study aimed to carry out preliminary tests of the removability of an artificial biofilm equivalent (ABE) and to verify the reproducibility of the ABE testing protocol for a planned main study.Background: There is a lack of data to develop suitable artificial biofilm substitutes, which may be helpful to perform denture hygiene education and to carry out in vitro examinations of oral hygiene products.Materials and Methods: This single‐group, prospective, longitudinal, interventional pilot study was conducted in Dresden (Germany) from February until December 2020. Participants were recruited who wore fully functional upper complete dentures. Denture biofilm was grown on acrylic specimens by wearing dentures for 12 h and 36 h using intraoral appliances. Acrylic specimens were coated with ABEs of three compositions: chitosan (ChS) 0.3 g, methylcellulose (MC) 1.7 g; ChS 0.2 g, MC 1.8 g; ChS 0.1 g, MC 1.9 g (labelled 1.7MC, 1.8MC and 1.9MC, respectively). All specimens underwent standardised mechanical brushing. The percentages of remaining biofilm (POB) were measured.Results: Thirty‐one participants were prescreened, and eight (26%) were included. The appliances were well tolerated, and biofilm was collected. ABE was prepared and brushed as planned. Three and six brushing strokes were needed to remove 12‐h and 36‐h natural denture biofilm, respectively. Correspondingly, three brushing strokes were needed to remove 1.9MC ABE and six brushing strokes to remove 1.8MC and 1.7MC ABE. A reproducibility of ABE removal was indicated.Conclusion: The removability of ABE and the ABE testing protocol were feasible and reproducible for conducting the future main study.
- Open Access
- 27 January 2022
- Published by Hindawi Limited in International Journal of Polymer Science
- Vol. 2022, 1-7
Novel Artificial Biofilm Equivalent for Denture Surfaces: A Pilot Study
The microbial population of the dental biofilm is embedded in an extracellular matrix that contains organic polymers such as polysaccharides. The extracellular matrix promotes biofilm adhesion on surfaces of dental prostheses and acts as a protective barrier. Thus, a breakdown of the extracellular matrix is crucial for an effective mechanical biofilm removal by brushing. The purpose of this study was to develop an artificial biofilm equivalent (ABE) that is able to mimic the mechanical properties of a natural biofilm concerning abrasion resistance. It contains the two polysaccharides chitosan (ChS) and methylcellulose (MC). Polymethylmethacrylate (PMMA) cylinders ( ) were manufactured and coated with the ABE with varying concentration ratios of ChS and MC. Eight test series ( each) with different mixing ratios of ChS/MC were tested for their abrasion resistance to brushing in a toothbrush simulator. For the ABE, a total of 2.0 g of polysaccharides were added to 100 ml of 2% acetic acid: 0.3–1.0 g ChS and 1.0–1.7 MC, respectively. Furthermore, two control series ( each) with 2.0 g of ChS only or 2.0 g of MC only were performed. Coated specimens were subjected to an increasing number of brushing strokes from 5 to 45 via abrasion test. The specimens were photographed, and a computerized planimetric method (CPM) was used to calculate the percentage of remaining ABE on the brushed areas of the PMMA cylinders. The abrasion resistance of the ABE to brushing decreased with an increasing ratio of MC in the mixture. The abrasion resistance of the ABE can be adjusted by changing the ratio of ChS and MC.
- 27 January 2022
- Published by Hindawi Limited in International Journal of Polymer Science
- Vol. 2022, 1-7
Open AccessNovel Artificial Biofilm Equivalent for Denture Surfaces: A Pilot Study
The microbial population of the dental biofilm is embedded in an extracellular matrix that contains organic polymers such as polysaccharides. The extracellular matrix promotes biofilm adhesion on surfaces of dental prostheses and acts as a protective barrier. Thus, a breakdown of the extracellular matrix is crucial for an effective mechanical biofilm removal by brushing. The purpose of this study was to develop an artificial biofilm equivalent (ABE) that is able to mimic the mechanical properties of a natural biofilm concerning abrasion resistance. It contains the two polysaccharides chitosan (ChS) and methylcellulose (MC). Polymethylmethacrylate (PMMA) cylinders ( ) were manufactured and coated with the ABE with varying concentration ratios of ChS and MC. Eight test series ( each) with different mixing ratios of ChS/MC were tested for their abrasion resistance to brushing in a toothbrush simulator. For the ABE, a total of 2.0 g of polysaccharides were added to 100 ml of 2% acetic acid: 0.3–1.0 g ChS and 1.0–1.7 MC, respectively. Furthermore, two control series ( each) with 2.0 g of ChS only or 2.0 g of MC only were performed. Coated specimens were subjected to an increasing number of brushing strokes from 5 to 45 via abrasion test. The specimens were photographed, and a computerized planimetric method (CPM) was used to calculate the percentage of remaining ABE on the brushed areas of the PMMA cylinders. The abrasion resistance of the ABE to brushing decreased with an increasing ratio of MC in the mixture. The abrasion resistance of the ABE can be adjusted by changing the ratio of ChS and MC.
- 1 December 2021
- Published by Georg Thieme Verlag KG in ZWR - Das Deutsche Zahnärzteblatt
- Vol. 130 (12) , 617-627
Gussklammerverankerte Teilprothesen – ein kleines Repetitorium
Die deutsche Mundgesundheitsstudie DMS V fordert, „geeignete zahnmedizinische Konzepte für die Lebensphase einer (…) zunehmenden Gebrechlichkeit bereitzuhalten“ [1]. Die gussklammerverankerte Teilprothese vereinigt minimale Invasivität mit Kosteneffizienz und hoher Funktionalität [2] [3] [4] [5]. Sie scheint im Kontext der DMS V das geeignete Therapiemittel. Dieses kleine Repetitorium greift noch einmal einzelne Aspekte des Designs gussklammerverankerter Teilprothesen auf. Publication Date: 04 January 2022 (online) © 2021. Thieme. All rights reserved. Georg Thieme Verlag KG Rüdigerstraße 14, 70469 Stuttgart, Germany
- 1 December 2021
- Published by Georg Thieme Verlag KG in ZWR - Das Deutsche Zahnärzteblatt
- Vol. 130 (12) , 617-627
Gussklammerverankerte Teilprothesen – ein kleines Repetitorium
Die deutsche Mundgesundheitsstudie DMS V fordert, „geeignete zahnmedizinische Konzepte für die Lebensphase einer (…) zunehmenden Gebrechlichkeit bereitzuhalten“ [1]. Die gussklammerverankerte Teilprothese vereinigt minimale Invasivität mit Kosteneffizienz und hoher Funktionalität [2] [3] [4] [5]. Sie scheint im Kontext der DMS V das geeignete Therapiemittel. Dieses kleine Repetitorium greift noch einmal einzelne Aspekte des Designs gussklammerverankerter Teilprothesen auf. Publication Date: 04 January 2022 (online) © 2021. Thieme. All rights reserved. Georg Thieme Verlag KG Rüdigerstraße 14, 70469 Stuttgart, Germany
- Open Access
Antifungal and Surface Properties of Chitosan-Salts Modified PMMA Denture Base Material
Chitosan (CS) and its derivatives show antimicrobial properties. This is of interest in preventing and treating denture stomatitis, which can be caused by fungi. Therefore, the aim of this study was the development of a novel antifungal denture base material by modifying polymethyl methacrylate (PMMA) with CS-salt and characterizing its antifungal and surface properties in vitro. For this purpose, the antifungal effect of chitosan-hydrochloride (CS-HCl) or chitosan-glutamate (CS-G) as solutions in different concentrations was determined. To obtain modified PMMA resin specimens, the CS-salts were added to the PMMA before polymerization. The roughness of these specimens was measured by contact profilometry. For the evaluation of the antifungal properties of the CS-salt modified resins, a C. albicans biofilm assay on the specimens was performed. As solutions, both the CS-G and CS-HCl-salt had an antifungal effect and inhibited C. albicans growth in a dose-dependent manner. In contrast, CS-salt modified PMMA resins showed no significant reduced C. albicans biofilm formation. Furthermore, the addition of CS-salts to PMMA significantly increased the surface roughness of the specimens. This study shows that despite the antifungal effect of CS-salts in solution, a modification of PMMA resin with these CS-salts does not improve the antifungal properties of PMMA denture base material.
Open AccessAntifungal and Surface Properties of Chitosan-Salts Modified PMMA Denture Base Material
Chitosan (CS) and its derivatives show antimicrobial properties. This is of interest in preventing and treating denture stomatitis, which can be caused by fungi. Therefore, the aim of this study was the development of a novel antifungal denture base material by modifying polymethyl methacrylate (PMMA) with CS-salt and characterizing its antifungal and surface properties in vitro. For this purpose, the antifungal effect of chitosan-hydrochloride (CS-HCl) or chitosan-glutamate (CS-G) as solutions in different concentrations was determined. To obtain modified PMMA resin specimens, the CS-salts were added to the PMMA before polymerization. The roughness of these specimens was measured by contact profilometry. For the evaluation of the antifungal properties of the CS-salt modified resins, a C. albicans biofilm assay on the specimens was performed. As solutions, both the CS-G and CS-HCl-salt had an antifungal effect and inhibited C. albicans growth in a dose-dependent manner. In contrast, CS-salt modified PMMA resins showed no significant reduced C. albicans biofilm formation. Furthermore, the addition of CS-salts to PMMA significantly increased the surface roughness of the specimens. This study shows that despite the antifungal effect of CS-salts in solution, a modification of PMMA resin with these CS-salts does not improve the antifungal properties of PMMA denture base material.
- Open Access
- 20 June 2018
- Published by Wiley in Pain Research and Management
- Vol. 2018, 1-2
Pain of Temporomandibular Disorders: From Etiology to Management
- 20 June 2018
- Published by Wiley in Pain Research and Management
- Vol. 2018, 1-2
Open AccessPain of Temporomandibular Disorders: From Etiology to Management