MKMatthew A. Koc

Matthew A. Koc

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Matthew A. Koc has a total of 105 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • CCAT: Silicon-Platelet Feedhorns for Submillimeter Wavelengths

    by Jason Austermann, James Beall, James R. Burgoyne, Scott Chapman, Steve Choi, Cody J. Duell, Anthony I. Huber, Johannes Hubmayr, Matthew A. Koc, Michael D. Niemack, et al.

    Silicon-platelet feedhorn arrays are an established technology at millimeter wavelengths that, for some applications, can provide significant advantages over traditional direct-machined metal feedhorns. The Prime-Cam focal planes operating in the 350 GHz ($\sim$860 $\mu$m) and 850 GHz ($\sim$350 $\mu$m) bands are anticipated to carry the first silicon-platelet feedhorn arrays to operate fully at submillimeter wavelengths, representing a significant step forward in the application of this technology. In particular, the feedhorns designed for operation in the 850 GHz band represent a 3x increase in frequency compared to previously demonstrated and deployed devices of this type. Here we present a demonstration of silicon-platelet feedhorns at these submillimeter wavelengths, including in-lab performance characterization. We present fabrication metrology, room-temperature beam maps, and cryogenic optical efficiency measurements where the feedhorns are coupled to prototype CCAT Prime-Cam detectors. We show that feedhorn performance measurements are well matched to simulation and compare that performance directly to traditional, direct-machined metal feedhorns.


  • Spectral Characterization of a 90 GHz CLASS Pixel

    by Gregory Jaehnig, John Appel, Sarah Marie Bruno, Jake Connors, Shannon M. Duff, Naina Gupta, Johannes Hubmayr, Matthew A. Koc, Tammy Lucas, Tobias Marriage, et al.

    The Cosmology Large Angular Scale Surveyor (CLASS) is an experiment designed to measure the polarization of the cosmic microwave background on large angular scales to probe cosmic reionization and search for the inflationary $B$-mode signal. CLASS is a multi-frequency ensemble of telescopes with bands centered at 40, 90, 150, and 220GHz. Each telescope has arrays of feedhorn-coupled transition edge sensor bolometers at the focal plane. The frequency response is primarily defined by the on-chip bandpass filter with additional contributions coming from the feedhorn, orthomode transducer, and 180-degree hybrid. In this study, we compare simulations and measurements of the frequency response of single pixel witness devices in the 90GHz band with and without the bandpass filter. For the first time, we can separate the effects of the bandpass filter from the other microwave components using Fourier transform spectroscopy and design splits of the pixel. The results show that the -3 dB band edges are 80GHz and 108 GHz. The measurements demonstrate a robust method for characterizing the spectral response of individual components, which is crucial for optimizing the performance of future detector arrays.


  • Development of Silicon Micromachined Waveguide Filter-Banks for On-Chip Spectrometers

    by Matthew A. Koc, Jason Austermann, James Beall, Johannes Hubmayr, Joel N. Ullom, Michael Vissers, Jordan Wheeler

    Development of high-speed, spatial-mapping spectrometers in the millimeter and far-infrared frequencies would enable entirely new research avenues in astronomy and cosmology. An “on-chip” spectrometer is one such technology that could enable Line Intensity Mapping. Recent work has shown the promise of high-speed imaging; however, a limiting factor is that many of these devices suffer from low optical efficiency. Here we present the fabrication of a metalized, Si waveguide filter-bank fabricated using deep reactive ion etching for use in millimeter spectroscopy. Our design simultaneously provides high-density pixel packing, high optical efficiency, high spectral resolution, and is readily compatible with simple and multiplexable MKID arrays. Gold plated test waveguide and filter show excellent match to simulations with a measured resolving power of 263 and a loss quality factor of 1116 at room temperature. The results show promise for extending the measurements to larger, multi-wavelength designs.


  • Open Access

    Simons Observatory: Characterization of the Large Aperture Telescope Receiver

    by Tanay Bhandarkar, Saianeesh K. Haridas, Jeff Iuliano, Anna Kofman, Alex Manduca, Karen Perez Sarmiento, John Orlowski-Scherer, Thomas P. Satterthwaite, Yuhan Wang, Zeeshan Ahmed, et al.

    The Simons Observatory (SO) is a ground-based cosmic microwave background (CMB) survey experiment that currently consists of three 0.42 m small-aperture telescopes and one 6 m large-aperture telescope (LAT), located at an elevation of 5200 m in the Atacama Desert in Chile. At the LAT’s focal plane, SO will install >62,000 transition-edge sensor detectors across 13 optics tubes (OTs) within the Large Aperture Telescope Receiver (LATR), the largest cryogenic camera ever built to observe the CMB. Here we report on the validation of the LATR in the laboratory and the subsequent dark testing and validation within the LAT. We show that the LATR meets cryogenic, optical, and detector specifications required for high-sensitivity measurements of the CMB. At the time of writing, the LATR is installed in the LAT with six OTs (corresponding to >31,000 detectors), and the LAT mirrors and remaining seven OTs are undergoing development.


  • Open Access

    Molecular and translational biology of the blood-based VeriStrat® proteomic test used in cancer immunotherapy treatment guidance

    by Matthew A. Koc, Timothy Aaron Wiles, Daniel C. Weinhold, Steven Rightmyer, Amanda L. Weaver, Colin T. McDowell, Joanna Roder, Senait Asmellash, Gary A. Pestano, Heinrich Roder, et al.

    The VeriStrat® test (VS) is a blood-based assay that predicts a patient's response to therapy by analyzing eight features in a spectrum obtained from matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) analysis of human serum and plasma. In a recent analysis of the INSIGHT clinical trial (NCT03289780), it was found that the VS labels, VS Good and VS Poor, can effectively predict the responsiveness of non-small cell lung cancer (NSCLC) patients to immune checkpoint inhibitor (ICI) therapy. However, while VS measures the intensities of spectral features using MALDI-TOF analysis, the specific proteoforms underlying these features have not been comprehensively identified. The objective of this study was to identify the proteoforms that are measured by VS. To resolve the features obtained from the low-resolution MALDI-TOF procedure used to acquire mass spectra for VS DeepMALDI® analysis of serum was employed. This technique allowed for the identification of finer peaks within these features. Additionally, a combination of reversed-phase fractionation and liquid chromatography-tandem mass spectrometry (LC-MS/MS) was then used to identify the proteoforms associated with these peaks. The analysis revealed that the primary constituents of the spectrum measured by VS are serum amyloid A1, serum amyloid A2, serum amyloid A4, C-reactive protein, and beta-2 microglobulin. Proteoforms involved in host immunity were identified as significant components of these features. This newly acquired information improves our understanding of how VS can accurately predict patient response to therapy. It opens up additional studies that can expand our understanding even further.


  • Open Access

    Semi-Quantitative MALDI Measurements of Blood-Based Samples for Molecular Diagnostics

    by Matthew A. Koc, Senait Asmellash, Patrick Norman, Steven Rightmyer, Joanna Roder, Robert W. Georgantas, Heinrich Roder

    Accurate and precise measurement of the relative protein content of blood-based samples using mass spectrometry is challenging due to the large number of circulating proteins and the dynamic range of their abundances. Traditional spectral processing methods often struggle with accurately detecting overlapping peaks that are observed in these samples. In this work, we develop a novel spectral processing algorithm that effectively detects over 1650 peaks with over 3.5 orders of magnitude in intensity in the 3 to 30 kD m/z range. The algorithm utilizes a convolution of the peak shape to enhance peak detection, and accurate peak fitting to provide highly reproducible relative abundance estimates for both isolated peaks and overlapping peaks. We demonstrate a substantial increase in the reproducibility of the measurements of relative protein abundance when comparing this processing method to a traditional processing method for sample sets run on multiple matrix-assisted laser desorption/ionization-time of flight (MALDI-TOF) instruments. By utilizing protein set enrichment analysis, we find a sizable increase in the number of features associated with biological processes compared to previously reported results. The new processing method could be very beneficial when developing high-performance molecular diagnostic tests in disease indications.


  • Top Cited Papers

    Design Principles for Trap-Free CsPbX3 Nanocrystals: Enumerating and Eliminating Surface Halide Vacancies with Softer Lewis Bases

    by David P. Nenon, Kimo Pressler, Jun Kang, Brent A. Koscher, Jacob H. Olshansky, Wojciech T. Osowiecki, Matthew A. Koc, Lin-Wang Wang, A. Paul Alivisatos

    We introduce a general surface passivation mechanism for cesium lead halide perovskite materials (CsPbX3, X = Cl, Br, I) that is supported by a combined experimental and theoretical study of the nanocrystal surface chemistry. A variety of spectroscopic methods are employed together with ab initio calculations to identify surface halide vacancies as the predominant source of charge trapping. The number of surface traps per nanocrystal is quantified by 1H NMR spectroscopy, and that number is consistent with a simple trapping model in which surface halide vacancies create deleterious under-coordinated lead atoms. These halide vacancies exhibit trapping behavior that differs between CsPbCl3, CsPbBr3, and CsPbI3. Ab initio calculations suggest that introduction of anionic X-type ligands can produce trap-free bandgaps by altering the energetics of lead-based defect levels. General rules for selecting effective passivating ligand pairs are introduced by considering established principles of coordination chemistry. Introducing softer, anionic, X-type Lewis bases that target under-coordinated lead atoms results in absolute quantum yields approaching unity and monoexponential luminescence decay kinetics, thereby indicating full trap passivation. This work provides a systematic framework for preparing highly luminescent CsPbX3 nanocrystals with variable compositions and dimensionalities, thereby improving fundamental understanding of these materials and informing future synthetic and post-synthetic efforts towards trap-free CsPbX3 nanocrystals.


  • Tunable Anisotropic Photon Emission from Self-Organized CsPbBr3 Perovskite Nanocrystals

    by Matthew J. Jurow, Thomas Lampe, Erika Penzo, Jun Kang, Matthew A. Koc, Thomas Zechel, Zachary Nett, Michael Brady, Lin-Wang Wang, A. Paul Alivisatos, et al.

    We report controllable anisotropic light emission of photons originating from vertically aligned transition dipole moments in spun-cast films of CsPbBr3 nanocubes. By depositing films of nanocrystals on precoated substrates we can control the packing density and resultant radiation pattern of the emitted photons. We develop a technical framework to calculate the average orientation of light emitters, i.e., the angle between the transition dipole moment vector (TDM) and the substrate. This model is applicable to any emissive material with a known refractive index. Theoretical modeling indicates that oriented emission originates from an anisotropic alignment of the valence band and conduction band edge states on the ionic crystal lattice and demonstrates a general path to model the experimentally less accessible internal electric field of a nanosystem from the photoluminescent anisotropy. The uniquely accessible surface of the perovskite nanoparticles allows for perturbation of the normally isotropic emissive transition. The reported sensitive and tunable TDM orientation and control of emitted light will allow for applications of perovskite nanocrystals in a wide range of photonic technologies inaccessible to traditional light emitters.


  • Characterizing Photon Reabsorption in Quantum Dot-Polymer Composites for Use as Displacement Sensors

    by Matthew A. Koc, Shilpa N. Raja, Lindsey A. Hanson, Son C. Nguyen, Nicholas J. Borys, Alexander S. Powers, Siva Wu, Kaori Takano, Joseph K. Swabeck, Jacob H. Olshansky, et al.

    The reabsorption of photoluminescence within a medium, an effect known as the inner filter effect (IFE), has been well studied in solutions, but has garnered less attention in regards to solid-state nanocomposites. Photoluminescence from a quantum dot (QD) can selectively excite larger QDs around it resulting in a net red-shift in the reemitted photon. In CdSe/CdS core/shell QD-polymer nanocomposites, we observe a large spectral red-shift of over a third of the line width of the photoluminescence of the nanocomposites over a distance of 100 μm resulting from the IFE. Unlike fluorescent dyes, which do not show a large IFE red-shift, QDs have a component of inhomogeneous broadening that originates from their size distribution and quantum confinement. By controlling the photoluminescence broadening as well as the sample dispersion and concentration, we show that the magnitude of the IFE within the nanocomposite can be tuned. We further demonstrate that this shift can be exploited in order to spectroscopically monitor the vertical displacement of a nanocomposite in a fluorescence microscope. Large energetic shifts in the measured emission with displacement can be maximized, resulting in a displacement sensor with submicrometer resolution. We further show that the composite can be easily attached to biological samples and is able to measure deformations with high temporal and spatial precision.


  • Encapsulation of Perovskite Nanocrystals into Macroscale Polymer Matrices: Enhanced Stability and Polarization

    by Shilpa N. Raja, Yehonadav Bekenstein, Matthew A. Koc, Stefan Fischer, Dandan Zhang, Liwei Lin, Robert O. Ritchie, Peidong Yang, A. Paul Alivisatos

    Lead halide perovskites hold promise for photonic devices, due to their superior optoelectronic properties. However, their use is limited by poor stability and toxicity. We demonstrate enhanced water and light stability of high-surface-area colloidal perovskite nanocrystals by encapsulation of colloidal CsPbBr3 quantum dots into matched hydrophobic macroscale polymeric matrices. This is achieved by mixing the quantum dots with presynthesized high-molecular-weight polymers. We monitor the photoluminescence quantum yield of the perovskite–polymer nanocomposite films under water-soaking for the first time, finding no change even after >4 months of continuous immersion in water. Furthermore, photostability is greatly enhanced in the macroscale polymer-encapsulated nanocrystal perovskites, which sustain >1010 absorption events per quantum dot prior to photodegradation, a significant threshold for potential device use. Control of the quantum dot shape in these thin-film polymer composite enables color tunability via strong quantum-confinement in nanoplates and significant room temperature polarized emission from perovskite nanowires. Not only does the high-molecular-weight polymer protect the perovskites from the environment but also no escaped lead was detected in water that was in contact with the encapsulated perovskites for months. Our ligand-passivated perovskite-macroscale polymer composites provide a robust platform for diverse photonic applications.