XLX. Allen Li

X. Allen Li

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


X. Allen Li has a total of 291 co-authors. Here are the top co-authors by number of shared publications:

  • Beth Erickson

    Department of Radiation Oncology Medical College of Wisconsin Milwaukee Wisconsin USA

    23 shared publications
  • An Tai

    Department of Radiation Oncology Medical College of Wisconsin Milwaukee Wisconsin USA

    16 shared publications
  • Eric Paulson

    Department of Radiation Oncology, Medical College of Wisconsin, Milwaukee, WI, United States

    14 shared publications
  • William Hall

    Department of Radiation Oncology Medical College of Wisconsin Milwaukee Wisconsin USA

    11 shared publications
  • Xinfeng Chen

    Department of Radiation Oncology Medical College of Wisconsin Milwaukee Wisconsin USA

    11 shared publications
  • Ergun Ahunbay

    Department of Radiation Oncology, Medical College of Wisconsin, Milwaukee, Wisconsin

    9 shared publications

Latest Publications

  • Concurrent Versus Sequential Radiation Dose Escalation to the Surgical Cavity for Conservative Treatment of High-Risk Early Breast Cancer: NRG/RTOG 1005 Phase III Trial

    by Frank A. Vicini, Kathryn Winter, Gary M. Freedman, Douglas W. Arthur, Barry S. Rosenstein, Soren M. Bentzen, X. Allen Li, Michele Y. Halyard, Wendy A. Woodward, Richard J. Bleicher, et al.

    PURPOSE: For patients with breast cancer undergoing breast conservation, escalating the dose (boost) of radiation to the lumpectomy cavity after whole-breast irradiation (WBI) reduces ipsilateral breast recurrence (IBR) but extends treatment duration. This phase III trial investigated whether boost delivery during WBI versus after WBI provides noninferior IBR and preserves cosmetic appearance. METHODS: NRG/RTOG 1005 randomly assigned patients at higher risk for IBR after lumpectomy and axillary surgery to either a sequential boost of 12 Gy in six fractions(F) or 14 Gy in 7F after WBI of 50 Gy in 25F or 42.7 Gy in 16F (sequential arm) or a concurrent boost of 8 Gy in 15F of 0.53 Gy per day with WBI of 40 Gy in 15F (concurrent arm) using 3-dimensional conformal radiation therapy (RT) or intensity-modulated RT. Based on 1.59% 5-year IBR for the sequential arm, defining the noninferiority margin as a hazard ratio upper limit on the 90% CI of 2.12, 2,312 patients provide 80% power for noninferiority of IBR as first recurrence for the concurrent arm. Secondary end points included disease-free survival and overall survival, adverse events (AEs), and cosmetic outcomes. RESULTS: Between May 24, 2011, and June 20, 2014, 2,354 patients were randomly assigned, with 2,255 eligible for analysis (sequential arm, n = 1,118; concurrent arm, n = 1,137). With median follow-up of 7.3 years, there were 56 IBR events; 5- and 7-year IBR were 2.1% and 2.2% on the sequential arm and 1.9% and 2.6% on the concurrent arm, respectively. The noninferiority criterion was met: HR (90% CI): 1.31 (0.84 to 2.04), P = .037. No differences were observed in AEs, cosmetic outcomes, or survival between arms. CONCLUSION: Concurrent boost during WBI results in noninferior IBR compared with sequential boost without worsening toxicity or cosmetic outcomes and reduces overall treatment time.


  • Open Access

    Organ‐specific equivalent uniform dose constraints and radiobiological parameters for radiation treatment planning of abdominal tumors

    by Samira Dabaghmanesh, X. Allen Li, Eric S. Paulson, Beth Erickson, William Hall, An Tai

    Background: Radiation therapy planning (RTP) for abdominal tumors often requires multiple dose‐volume constraints for each organ at risk (OAR), which vary with different fractionation schemes. This variability can complicate biologically optimized treatment planning. Purpose: This study aims to extract fractionation‐independent dose constraints based on the concept of equivalent uniform dose (EUD), utilizing published clinical data for a range of fractionation regimens. The goal is to derive organ‐specific radiobiological parameters as well as the EUD for each OAR that can be used in biologically optimized treatment planning for abdominal tumors, independent of the specific fractionation scheme applied. Methods: Clinical dose‐volume constraints for duodenum, stomach, and small bowel were compiled from available literature sources. These dose constraints were obtained for conventionally fractionated radiotherapy (CFRT), hypofractionated RT, and stereotactic body radiotherapy (SBRT) and were associated with less than a 10% risk of grade 3 toxicity as categorized by CTCAE v.3 or v.4, RTOG, and EORTC. For each OAR, an iso‐EUD fitting with EUD calculated based on the linear‐quadratic (LQ) model or linear‐quadratic‐linear (LQ‐L) model and a dose volume histogram generated from these dose volume constraints for each fractionation was applied to extract model parameters such as α / β ratio and ‘ n ’ (the volume effect of the OAR). Based on the obtained parameters, the dose constraint in EUD and the equivalent physical dose in 2Gy fraction (EQD2) were calculated. Results: The EUD constraints for LQ‐L (LQ) models are 52.62 (55.10) Gy, 48.22 (48.60) Gy, and 46.10 (45.06) Gy, α / β values are 5.42 (5.59) Gy, 7.67 (6.76) Gy, and 12.15 (8.20) Gy, and ‘ n ’ values are 0.06 (0.01), 0.03 (0.02), and 0.06 (0.08) for duodenum, small bowel, and stomach, respectively. Additional two parameters for the three OARs in LQ‐L are 5.15 Gy, 8.65 Gy, and 5.20 Gy for dt and 5.40, 4.72, and 3.33 for γ/α . The LQ‐L model fits the clinical data better than the LQ model. Conclusions: The obtained α / β values are comparable with those published previously. The extracted EUD constraints together with the volume effect parameter ‘ n ’ can be used for plan optimization and evaluation.

  • Open Access

    Enhancing pancreatic tumor delineation using dual-energy CT-derived extracellular volume fraction map

    by Silambarasan Anbumani, Garrett Godfrey, William A Hall, Jainil Shah, Paul Knechtges, Beth Erickson, X Allen Li, George Noid

    Purpose. Precise identification of pancreatic tumors is challenging for radiotherapy planning due to the tumor's anatomical variability and poor visualization on 3D cross-sectional imaging. Low extracellular volume fraction (ECVf) correlates with poor vasculature uptake and possible necrosis or hypoxia in pancreatic tumors. This work investigates the feasibility of delineating pancreatic tumors using ECVf spatial distribution maps derived from contrast enhanced dual-energy CT (DECT). Methods and Materials. Data acquired from radiotherapy simulation of 12 pancreatic cancer patients, using a dual source DECT scanner, were analyzed. For each patient, an ECVf distribution of the pancreas was computed from the simultaneously acquired low and high energy DECT series during the late arterial contrast phase combined with the patient’s hematocrit level. Volume of interest (VECVf) maps in ECVf distribution of pancreas were identified by applying an appropriate threshold condition and a connected components clustering algorithm. The obtained VECVf was compared with the clinical gross tumor volume (GTV) using the positive predictive value (PPV), Dice similarity coefficient (DSC), mean distance to agreement (MDA) and true positive rate (TPR). Results. As a proof of concept, our hypothetical threshold condition based on the first quartile separation of the ECVf distribution to find VECVf of the pancreas elucidates the tumor volume within the pancreas. Notably, 7 out of 12 cases studied for VECVf matched well with the GTV and the mean PPV of 0.83 ± 0.12. The mean MDA (2.83 ± 1.0) of the cases confirms that VECVf lies within the tolerance for comparing to the pancreatic GTV. For the remaining 5 cases, the VECVf is substantially affected by other compounding factors, e.g., large cysts, dilate ducts, and thus did not align with the GTVs. Conclusions. This work demonstrated the promising application of the ECVf map, derived from contrast enhanced DECT, to help delineate tumor target for RT planning of pancreatic cancer.


  • Obtaining organ-specific radiobiological parameters from clinical data for radiation therapy planning of head and neck cancers

    by Edwin E Quashie, X Allen Li, Phillip Prior, Musaddiq Awan, Christopher Schultz, An Tai

    Objective. Different radiation therapy (RT) strategies, e.g. conventional fractionation RT (CFRT), hypofractionation RT (HFRT), stereotactic body RT (SBRT), adaptive RT, and re-irradiation are often used to treat head and neck (HN) cancers. Combining and/or comparing these strategies requires calculating biological effective dose (BED). The purpose of this study is to develop a practical process to estimate organ-specific radiobiologic model parameters that may be used for BED calculations in individualized RT planning for HN cancers. Approach. Clinical dose constraint data for CFRT, HFRT and SBRT for 5 organs at risk (OARs) namely spinal cord, brainstem, brachial plexus, optic pathway, and esophagus obtained from literature were analyzed. These clinical data correspond to a particular endpoint. The linear-quadratic (LQ) and linear-quadratic-linear (LQ-L) models were used to fit these clinical data and extract relevant model parameters (alpha/beta ratio, gamma/alpha, d T and BED) from the iso-effective curve. The dose constraints in terms of equivalent physical dose in 2 Gy-fraction (EQD2) were calculated using the obtained parameters. Main results. The LQ-L and LQ models fitted clinical data well from the CFRT to SBRT with the LQ-L representing a better fit for most of the OARs. The alpha/beta values for LQ-L (LQ) were found to be 2.72 (2.11) Gy, 0.55 (0.30) Gy, 2.82 (2.90) Gy, 6.57 (3.86) Gy, 5.38 (4.71) Gy, and the dose constraint EQD2 were 55.91 (54.90) Gy, 57.35 (56.79) Gy, 57.54 (56.35) Gy, 60.13 (59.72) Gy and 65.66 (64.50) Gy for spinal cord, optic pathway, brainstem, brachial plexus, and esophagus, respectively. Additional two LQ-L parameters d T were 5.24 Gy, 5.09 Gy, 7.00 Gy, 5.23 Gy, and 6.16 Gy, and gamma/alpha were 7.91, 34.02, 8.67, 5.62 and 4.95. Significance. A practical process was developed to extract organ-specific radiobiological model parameters from clinical data. The obtained parameters can be used for biologically based radiation planning such as calculating dose constraints of different fractionation regimens.


  • Open Access

    Deep learning auto-segmentation on multi-sequence magnetic resonance images for upper abdominal organs

    by Asma Amjad, Jiaofeng Xu, Dan Thill, Ying Zhang, Jie Ding, Eric Paulson, William Hall, Beth A. Erickson, X. Allen Li

    Introduction: Multi-sequence multi-parameter MRIs are often used to define targets and/or organs at risk (OAR) in radiation therapy (RT) planning. Deep learning has so far focused on developing auto-segmentation models based on a single MRI sequence. The purpose of this work is to develop a multi-sequence deep learning based auto-segmentation (mS-DLAS) based on multi-sequence abdominal MRIs.Materials and methods: Using a previously developed 3DResUnet network, a mS-DLAS model using 4 T1 and T2 weighted MRI acquired during routine RT simulation for 71 cases with abdominal tumors was trained and tested. Strategies including data pre-processing, Z-normalization approach, and data augmentation were employed. Additional 2 sequence specific T1 weighted (T1-M) and T2 weighted (T2-M) models were trained to evaluate performance of sequence-specific DLAS. Performance of all models was quantitatively evaluated using 6 surface and volumetric accuracy metrics.Results: The developed DLAS models were able to generate reasonable contours of 12 upper abdomen organs within 21 seconds for each testing case. The 3D average values of dice similarity coefficient (DSC), mean distance to agreement (MDA mm), 95 percentile Hausdorff distance (HD95% mm), percent volume difference (PVD), surface DSC (sDSC), and relative added path length (rAPL mm/cc) over all organs were 0.87, 1.79, 7.43, -8.95, 0.82, and 12.25, respectively, for mS-DLAS model. Collectively, 71% of the auto-segmented contours by the three models had relatively high quality. Additionally, the obtained mS-DLAS successfully segmented 9 out of 16 MRI sequences that were not used in the model training.Conclusion: We have developed an MRI-based mS-DLAS model for auto-segmenting of upper abdominal organs on MRI. Multi-sequence segmentation is desirable in routine clinical practice of RT for accurate organ and target delineation, particularly for abdominal tumors. Our work will act as a stepping stone for acquiring fast and accurate segmentation on multi-contrast MRI and make way for MR only guided radiation therapy.


  • Automated deep learning auto-segmentation of air volumes for MRI-guided online adaptive radiation therapy of abdominal tumors

    by Ergun Ahunbay, Abdul K Parchur, Jiaofeng Xu, Dan Thill, Eric S Paulson, X Allen Li

    Objective . In the current MR-Linac online adaptive workflow, air regions on the MR images need to be manually delineated for abdominal targets, and then overridden by air density for dose calculation. Auto-delineation of these regions is desirable for speed purposes, but poses a challenge, since unlike computed tomography, they do not occupy all dark regions on the image. The purpose of this study is to develop an automated method to segment the air regions on MRI-guided adaptive radiation therapy (MRgART) of abdominal tumors. Approach . A modified ResUNet3D deep learning (DL)-based auto air delineation model was trained using 102 patients’ MR images. The MR images were acquired by a dedicated in-house sequence named ‘Air-Scan’, which is designed to generate air regions that are especially dark and accentuated. The air volumes generated by the newly developed DL model were compared with the manual air contours using geometric similarity (Dice Similarity Coefficient (DSC)), and dosimetric equivalence using Gamma index and dose-volume parameters. Main results . The average DSC agreement between the DL generated and manual air contours is 99% ± 1%. The gamma index between the dose calculations with overriding the DL versus manual air volumes with density of 0.01 is 97% ± 2% for a local gamma calculation with a tolerance of 2% and 2 mm. The dosimetric parameters from planning target volume—PTV and organs at risk—OARs were all within 1% between when DL versus manual contours were overridden by air density. The model runs in less than five seconds on a PC with 28 Core processor and NVIDIA Quadro ® P2000 GPU. Significance : a DL based automated segmentation method was developed to generate air volumes on specialized abdominal MR images and generate results that are practically equivalent to the manual contouring of air volumes.


  • Real‐time motion monitoring using orthogonal cine MRI during MR‐guided adaptive radiation therapy for abdominal tumors on 1.5T MR‐Linac

    by Hassan Jassar, An Tai, Xinfeng Chen, Timothy D. Keiper, Eric Paulson, Fabienne Lathuilière, Silvain Bériault, François Hébert, Laurence Savard, David T. Cooper, et al.

    Background: Real‐time motion monitoring (RTMM) is necessary for accurate motion management of intrafraction motions during radiation therapy (RT).Purpose: Building upon a previous study, this work develops and tests an improved RTMM technique based on real‐time orthogonal cine magnetic resonance imaging (MRI) acquired during magnetic resonance‐guided adaptive RT (MRgART) for abdominal tumors on MR‐Linac.Methods: A motion monitoring research package (MMRP) was developed and tested for RTMM based on template rigid registration between beam‐on real‐time orthogonal cine MRI and pre‐beam daily reference 3D‐MRI (baseline). The MRI data acquired under free‐breathing during the routine MRgART on a 1.5T MR‐Linac for 18 patients with abdominal malignancies of 8 liver, 4 adrenal glands (renal fossa), and 6 pancreas cases were used to evaluate the MMRP package. For each patient, a 3D mid‐position image derived from an in‐house daily 4D‐MRI was used to define a target mask or a surrogate sub‐region encompassing the target. Additionally, an exploratory case reviewed for an MRI dataset of a healthy volunteer acquired under both free‐breathing and deep inspiration breath‐hold (DIBH) was used to test how effectively the RTMM using the MMRP can address through‐plane motion (TPM). For all cases, the 2D T2/T1‐weighted cine MRIs were captured with a temporal resolution of 200 ms interleaved between coronal and sagittal orientations. Manually delineated contours on the cine frames were used as the ground‐truth motion. Common visible vessels and segments of target boundaries in proximity to the target were used as anatomical landmarks for reproducible delineations on both the 3D and the cine MRI images. Standard deviation of the error (SDE) between the ground‐truth and the measured target motion from the MMRP package were analyzed to evaluate the RTMM accuracy. The maximum target motion (MTM) was measured on the 4D‐MRI for all cases during free‐breathing.Results: The mean (range) centroid motions for the 13 abdominal tumor cases were 7.69 (4.71–11.15), 1.73 (0.81–3.05), and 2.71 (1.45–3.93) mm with an overall accuracy of <2 mm in the superior–inferior (SI), the left‐right (LR), and the anterior‐posterior (AP) directions, respectively. The mean (range) of the MTM from the 4D‐MRI was 7.38 (2–11) mm in the SI direction, smaller than the monitored motion of centroid, demonstrating the importance of the real‐time motion capture. For the remaining patient cases, the ground‐truth delineation was challenging under free‐breathing due to the target deformation and the large TPM in the AP direction, the implant‐induced image artifacts, and/or the suboptimal image plane selection. These cases were evaluated based on visual assessment. For the healthy volunteer, the TPM of the target was significant under free‐breathing which degraded the RTMM accuracy. RTMM accuracy of <2 mm was achieved under DIBH, indicating DIBH is an effective method to address large TPM.Conclusions: We have successfully developed and tested the use of a template‐based registration method for an accurate RTMM of abdominal targets during MRgART on a 1.5T MR‐Linac without using injected contrast agents or radio‐opaque implants. DIBH may be used to effectively reduce or eliminate TPM of abdominal targets during RTMM.


  • Deep learning based automatic contour refinement for inaccurate auto-segmentation in MR-guided adaptive radiotherapy

    by Jie Ding, Ying Zhang, Asma Amjad, Christina Sarosiek, Nguyen Phuong Dang, Mohammad Zarenia, X Allen Li

    Objective. Fast and accurate auto-segmentation is essential for magnetic resonance-guided adaptive radiation therapy (MRgART). Deep learning auto-segmentation (DLAS) is not always clinically acceptable, particularly for complex abdominal organs. We previously reported an automatic contour refinement (ACR) solution of using an active contour model (ACM) to partially correct the DLAS contours. This study aims to develop a DL-based ACR model to work in conjunction with ACM-ACR to further improve the contour accuracy. Approach. The DL-ACR model was trained and tested using bowel contours created by an in-house DLAS system from 160 MR sets (76 from MR-simulation and 84 from MR-Linac). The contours were classified into acceptable, minor-error and major-error groups using two approaches of contour quality classification (CQC), based on the AAPM TG-132 recommendation and an in-house classification model, respectively. For the major-error group, DL-ACR was applied subsequently after ACM-ACR to further refine the contours. For the minor-error group, contours were directly corrected by DL-ACR without applying an initial ACM-ACR. The ACR workflow was performed separately for the two CQC methods and was evaluated using contours from 25 image sets as independent testing data. Main results. The best ACR performance was observed in the MR-simulation testing set using CQC by TG-132: (1) for the major-error group, 44% (177/401) were improved to minor-error group and 5% (22/401) became acceptable by applying ACM-ACR; among these 177 contours that shifted from major-error to minor-error with ACM-ACR, DL-ACR further refined 49% (87/177) to acceptable; and overall, 36% (145/401) were improved to minor-error contours, and 30% (119/401) became acceptable after sequentially applying ACM-ACR and DL-ACR; (2) for the minor-error group, 43% (320/750) were improved to acceptable contours using DL-ACR. Significance. The obtained ACR workflow substantially improves the accuracy of DLAS bowel contours, minimizing the manual editing time and accelerating the segmentation process of MRgART.


  • Open Access

    Deep learning-based prediction of deliverable adaptive plans for MR-guided adaptive radiotherapy: A feasibility study

    by Laura Buchanan, Saleh Hamdan, Ying Zhang, Xinfeng Chen, X. Allen Li

    Purpose: Fast and automated plan generation is desirable in radiation therapy (RT), in particular, for MR-guided online adaptive RT (MRgOART) or real-time (intrafractional) adaptive RT (MRgRART), to reduce replanning time. The purpose of this study is to investigate the feasibility of using deep learning to quickly predict deliverable adaptive plans based on a target dose distribution for MRgOART/MRgRART.Methods: A conditional generative adversarial network (cGAN) was trained to predict the MLC leaf sequence corresponding to a target dose distribution based on reference plan created prior to MRgOART using a 1.5T MR-Linac. The training dataset included 50 ground truth dose distributions and corresponding beam parameters (aperture shapes and weights) created during MRgOART for 10 pancreatic cancer patients (each with five fractions). The model input was the dose distribution from each individual beam and the output was the predicted corresponding field segments with specific shape and weight. Patient-based leave-one-out-cross-validation was employed and for each model trained, four (44 training beams) out of five fractionated plans of the left-out patient were set aside for testing purposes. We deliberately kept a single fractionated plan in the training dataset so that the model could learn to replan the patient based on a prior plan. The model performance was evaluated by calculating the gamma passing rate of the ground truth dose vs. the dose from the predicted adaptive plan and calculating max and mean dose metrics.Results: The average gamma passing rate (95%, 3mm/3%) among 10 test cases was 88%. In general, we observed 95% of the prescription dose to PTV achieved with an average 7.6% increase of max and mean dose, respectively, to OARs for predicted replans. Complete adaptive plans were predicted in ≤20 s using a GTX 1660TI GPU.Conclusion: We have proposed and demonstrated a deep learning method to generate adaptive plans automatically and rapidly for MRgOART. With further developments using large datasets and the inclusion of patient contours, the method may be implemented to accelerate MRgOART process or even to facilitate MRgRART.


  • Auto‐detection of necessity for MRI‐guided online adaptive replanning using a machine learning classifier

    by Abdul K. Parchur, Sara Lim, Haidy G. Nasief, Eenas A. Omari, Ying Zhang, Eric S. Paulson, William A. Hall, Beth Erickson, X. Allen Li

    Purpose: MRI‐guided adaptive radiation therapy (MRgART), particularly daily online adaptive replanning (OLAR) can substantially improve radiation therapy delivery, however, it can be labor‐intensive and time‐consuming. Currently, the decision to perform OLAR for a treatment fraction is determined subjectively. In this work, we develop a machine learning algorithm based on structural similarity index measure (SSIM) and change in entropy to quickly and objectively determine whether OLAR is necessary for a daily MRI set.Methods: A total of 109 daily MRI sets acquired on a 1.5T MR‐Linac during MRgART for 22 pancreatic cancer patients each treated with five fractions were retrospectively analyzed. For each daily MRI set, OLAR and reposition (No‐OLAR) plans were created and the superior plan with the daily fraction determined per clinical dose‐volume criteria. SSIM and entropy maps were extracted from each daily MRI set, with respect to its reference (e.g., dry‐run) MRI in the region enclosed by 50‐100% isodose surfaces. A total of six common features were extracted from SSIM maps. Pearson's rank correlation coefficient was utilized to rule out redundant SSIM features. A t‐test was used to determine significant SSIM features which were combined with the change in entropy to develop anensemble machine classifier with fivefold cross validation. The performance of the classifier was evaluated using the area under the curve (AUC) of the receiver operating characteristic curve.Results: A machine learning classifier model using two SSIM features (mean and full width at half maximum) and change in entropy was determined to be able to significantly discriminate between No‐OLAR and OLAR groups. The obtained machine learning ensemble classifier can predict OLAR necessity with a cross validated AUC of 0.93. Misclassification was found primarily for No‐OLAR cases with dosimetric plan quality closely comparable to the corresponding OLAR plans, thus, are not a major practical concern.Conclusion: A machine learning classifier based on simple first‐order image features, that is, SSIM features and change in entropy, was developed to determine when OLAR is necessary for a daily MRI set with practical acceptable prediction accuracy. This classifier may be implemented in the MRgART process to automatically and objectively determine if OLAR is required following daily MRI.