Zhuo Jiang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Zhuo Jiang has a total of 91 co-authors. Here are the top co-authors by number of shared publications:
Sinan Zhang
College of Food Science, South China Agricultural University, Guangzhou 510640, China
6 shared publicationsXueshuang Yao
College of Food Science, South China Agricultural University, Guangzhou 510640, China
6 shared publicationsZhenhong Zheng
College of Food Science, South China Agricultural University, Guangzhou 510640, China
5 shared publicationsChao Fu
South China Agr Univ, Coll Food Sci, Guangzhou 510642, Peoples R China
4 shared publicationsBing Du
South China Agr Univ, Coll Food Sci, Guangzhou 510642, Peoples R China
3 shared publicationsChao Dai
South China Agr Univ, Coll Food Sci, Guangzhou 510642, Peoples R China
3 shared publications
Latest Publications
- 2 April 2026
- Published by American Chemical Society (ACS) in ACS Sensors
Ultrasensitive Cascade Enzyme Immunoassay Electrochemical Microfluidic Chip for Early Screening of Prostate Cancer
Immunosensors offer great promise for cancer diagnostics owing to their high sensitivity, specificity, and potential for miniaturization. However, conventional electrochemical immunosensors often rely on single-step enzyme reactions and single-biomarker detection, limiting their signal amplification capacity and diagnostic accuracy for complex diseases such as prostate cancer. Here, we presented an ultrasensitive cascade enzyme immunoassay electrochemical microfluidic chip (CEE-CHIP) for the simultaneous detection of multiple prostate cancer biomarkers. The system employed primary antibody-functionalized magnetic metal-organic frameworks (Fe3O4@MOF), followed by target antigens binding specifically and glucose oxidase-labeled secondary antibodies conjugating to form stable sandwich immunocomplexes. The functionalized Fe3O4@MOF were magnetically positioned within a microfluidic channel and a subsequent cascade reaction involving glucose oxidase generates H2O2. H2O2 was detected by a Co3O4/MXene-modified working electrode, resulting in amplified electrochemical signals. This system allowed for the simultaneous detection of multiple tumor markers, including prostate-specific antigen and Engrailed 2, with detection limits as low as 0.154 and 0.146 pg/mL, respectively. With a broad linear range (0.001-100 ng/mL), excellent sensitivity, and minimal sample consumption, the CEE-CHIP represented a promising non-invasive, point-of-care diagnostic platform for early prostate cancer detection and broader clinical applications.
- 2 April 2026
- Published by American Chemical Society (ACS) in ACS Sensors
Ultrasensitive Cascade Enzyme Immunoassay Electrochemical Microfluidic Chip for Early Screening of Prostate Cancer
Immunosensors offer great promise for cancer diagnostics owing to their high sensitivity, specificity, and potential for miniaturization. However, conventional electrochemical immunosensors often rely on single-step enzyme reactions and single-biomarker detection, limiting their signal amplification capacity and diagnostic accuracy for complex diseases such as prostate cancer. Here, we presented an ultrasensitive cascade enzyme immunoassay electrochemical microfluidic chip (CEE-CHIP) for the simultaneous detection of multiple prostate cancer biomarkers. The system employed primary antibody-functionalized magnetic metal-organic frameworks (Fe3O4@MOF), followed by target antigens binding specifically and glucose oxidase-labeled secondary antibodies conjugating to form stable sandwich immunocomplexes. The functionalized Fe3O4@MOF were magnetically positioned within a microfluidic channel and a subsequent cascade reaction involving glucose oxidase generates H2O2. H2O2 was detected by a Co3O4/MXene-modified working electrode, resulting in amplified electrochemical signals. This system allowed for the simultaneous detection of multiple tumor markers, including prostate-specific antigen and Engrailed 2, with detection limits as low as 0.154 and 0.146 pg/mL, respectively. With a broad linear range (0.001-100 ng/mL), excellent sensitivity, and minimal sample consumption, the CEE-CHIP represented a promising non-invasive, point-of-care diagnostic platform for early prostate cancer detection and broader clinical applications.
- Open Access
- 3 December 2025
- Published by MDPI AG in Micromachines
- Vol. 16  (12) , 1379
Small Object Localization with 90% Annotation Reduction by Positive-Unlabeled Learning
Small object localization is one of the most challenging tasks owing to the poor visual appearance and noisy representation caused by the intrinsic structure of small targets. Recent advances in localizing small objects are mainly dependent on regression-based counting approaches, which require considerable annotations for training. As a contrast, human learners can quickly master labeling skills from only a few annotation examples. In this paper, we attempt to simulate this training mechanism and propose a novel positive-unlabeled (PU) learning based approach that can localize small objects by learning from partial point annotations. We evaluate our approach on five typical datasets of small objects involving a single cell, an animal/insect, and human crowds. Quantitative experimental results show that our approach has achieved inspiring localization performance (F1 score > 0.75) even under the supervision of less than 10% of the overall point annotations. This approach paves the way for low-annotation-cost single-cell analysis within microfluidic droplets.
- 3 December 2025
- Published by MDPI AG in Micromachines
- Vol. 16  (12) , 1379
Open AccessSmall Object Localization with 90% Annotation Reduction by Positive-Unlabeled Learning
Small object localization is one of the most challenging tasks owing to the poor visual appearance and noisy representation caused by the intrinsic structure of small targets. Recent advances in localizing small objects are mainly dependent on regression-based counting approaches, which require considerable annotations for training. As a contrast, human learners can quickly master labeling skills from only a few annotation examples. In this paper, we attempt to simulate this training mechanism and propose a novel positive-unlabeled (PU) learning based approach that can localize small objects by learning from partial point annotations. We evaluate our approach on five typical datasets of small objects involving a single cell, an animal/insect, and human crowds. Quantitative experimental results show that our approach has achieved inspiring localization performance (F1 score > 0.75) even under the supervision of less than 10% of the overall point annotations. This approach paves the way for low-annotation-cost single-cell analysis within microfluidic droplets.
- 14 April 2025
- Published by Elsevier in Bioresource Technology
- Vol. 430, 132548
Deuterium stress Reprograms Chlorella sorokiniana Metabolism: Coupling photosynthetic suppression with carbon Reserve Surge
- 14 April 2025
- Published by Elsevier in Bioresource Technology
- Vol. 430, 132548
Deuterium stress Reprograms Chlorella sorokiniana Metabolism: Coupling photosynthetic suppression with carbon Reserve Surge
- Open Access
Research on the Asymmetric Phenomenon of Voltage Polarity Based on Dielectric Wetting
The present research investigated the voltage polarity asymmetry phenomenon based on dielectric wetting. In an ITO–hydrophobic layer–droplet setup, three reagents with different pH values (3.96, 7.0, and 10.18), two types of hydrophobic materials (AF1601 and 6%T6), and two different thicknesses (340 nm and 2.5 μm) of each material were systematically investigated. The results show that the thickness of the hydrophobic dielectric layer and the pH of the droplets had a significant impact on the droplet contact angle variation with the voltage. The contact angle on the thick hydrophobic dielectric layer followed the Lippmann–Young equation as the voltage changed. The angle of the thin hydrophobic dielectric layer was affected by its own properties and the type of droplet, which led to the occurrence of voltage polarity asymmetry of the electrowetting phenomenon. After further investigation of this phenomenon, it was found that it mainly accounted for the decrease in electric field strength at both ends of the droplet, which was caused by electrochemical reactions and changes in circuit resistance. The leakage current is an important indicator, and this phenomenon can be prevented by increasing the thickness of the hydrophobic dielectric layer.
Open AccessResearch on the Asymmetric Phenomenon of Voltage Polarity Based on Dielectric Wetting
The present research investigated the voltage polarity asymmetry phenomenon based on dielectric wetting. In an ITO–hydrophobic layer–droplet setup, three reagents with different pH values (3.96, 7.0, and 10.18), two types of hydrophobic materials (AF1601 and 6%T6), and two different thicknesses (340 nm and 2.5 μm) of each material were systematically investigated. The results show that the thickness of the hydrophobic dielectric layer and the pH of the droplets had a significant impact on the droplet contact angle variation with the voltage. The contact angle on the thick hydrophobic dielectric layer followed the Lippmann–Young equation as the voltage changed. The angle of the thin hydrophobic dielectric layer was affected by its own properties and the type of droplet, which led to the occurrence of voltage polarity asymmetry of the electrowetting phenomenon. After further investigation of this phenomenon, it was found that it mainly accounted for the decrease in electric field strength at both ends of the droplet, which was caused by electrochemical reactions and changes in circuit resistance. The leakage current is an important indicator, and this phenomenon can be prevented by increasing the thickness of the hydrophobic dielectric layer.
- 16 April 2024
- Published by Elsevier in Food Hydrocolloids
- Vol. 154
Preparation and evaluation of microcapsules of sodium alginate based on microfluidic technology
- 16 April 2024
- Published by Elsevier in Food Hydrocolloids
- Vol. 154
Preparation and evaluation of microcapsules of sodium alginate based on microfluidic technology
- 4 January 2024
- Published by Elsevier in Food Chemistry
- Vol. 442, 138359
Exploring the effect of high pressure in the denaturation of casein micelles by in-situ SERS
- 4 January 2024
- Published by Elsevier in Food Chemistry
- Vol. 442, 138359
Exploring the effect of high pressure in the denaturation of casein micelles by in-situ SERS
- 12 December 2023
- Published by Elsevier in Food Chemistry
- Vol. 440, 138159
Comprehensive investigation of pressure-induced gelatinization of starches using in situ and ex-situ technical analyses
- 12 December 2023
- Published by Elsevier in Food Chemistry
- Vol. 440, 138159
Comprehensive investigation of pressure-induced gelatinization of starches using in situ and ex-situ technical analyses
- 10 November 2022
- Published by Elsevier in Journal of Molecular Structure
- Vol. 1274
In-situ Raman study of α-D-glucose under different pressure and temperature
- 10 November 2022
- Published by Elsevier in Journal of Molecular Structure
- Vol. 1274
In-situ Raman study of α-D-glucose under different pressure and temperature
- 21 September 2022
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 94  (39) , 13463-13472
Facile Fabrication of Highly Quantum Dot/AuNP-Loaded Tags for a Dual-Modal Colorimetric/Reversed Ratiometric Fluorescence Immunochromatographic Assay
Developing an easily-prepared, sensitive, and accurate point-of-need immunochromatographic assay (ICA) is significant in food safety screening, clinical diagnosis, and environmental monitoring. However, the current single-modal ICAs are limited in certain instinct drawbacks that restrict analytical performances. Herein, we introduce an ultrasensitive dual-modal colorimetric/reversed ratiometric fluorescence ICA based on facilely prepared immunoprobes with a high loading capacity of red quantum dots and AuNPs. By smartly integrating these red-colored/fluorescent signal probes with an immobilized green quantum dot antigen on the test lines, discrete "turn-on" visual inspection and reversed ratiometric quantification via a portable smartphone-based analyzer were accomplished. As an application, this method was employed to detect 11 phosphodiesterase-5 inhibitors in health foods with ultralow detection limits (0.0028-0.045 ng/mL), high repeatability (coefficient of variations of 0.3-1.91%), and reasonable accuracy (recoveries of 86.6-107%). The proposed method was further validated by the authorized liquid chromatography with tandem mass spectrometry method in actual sample detection. This new assay format can be extended to ultrasensitive flexible detection of other food contaminants, environmental pollutants, or tumor biomarkers within minutes, and it just requires simply prepared signal reporters, easy-to-operate procedures, and a low-cost miniaturized analyzer.
- 21 September 2022
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 94  (39) , 13463-13472
Facile Fabrication of Highly Quantum Dot/AuNP-Loaded Tags for a Dual-Modal Colorimetric/Reversed Ratiometric Fluorescence Immunochromatographic Assay
Developing an easily-prepared, sensitive, and accurate point-of-need immunochromatographic assay (ICA) is significant in food safety screening, clinical diagnosis, and environmental monitoring. However, the current single-modal ICAs are limited in certain instinct drawbacks that restrict analytical performances. Herein, we introduce an ultrasensitive dual-modal colorimetric/reversed ratiometric fluorescence ICA based on facilely prepared immunoprobes with a high loading capacity of red quantum dots and AuNPs. By smartly integrating these red-colored/fluorescent signal probes with an immobilized green quantum dot antigen on the test lines, discrete "turn-on" visual inspection and reversed ratiometric quantification via a portable smartphone-based analyzer were accomplished. As an application, this method was employed to detect 11 phosphodiesterase-5 inhibitors in health foods with ultralow detection limits (0.0028-0.045 ng/mL), high repeatability (coefficient of variations of 0.3-1.91%), and reasonable accuracy (recoveries of 86.6-107%). The proposed method was further validated by the authorized liquid chromatography with tandem mass spectrometry method in actual sample detection. This new assay format can be extended to ultrasensitive flexible detection of other food contaminants, environmental pollutants, or tumor biomarkers within minutes, and it just requires simply prepared signal reporters, easy-to-operate procedures, and a low-cost miniaturized analyzer.