Cristina Canzi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Cristina Canzi has a total of 61 co-authors. Here are the top co-authors by number of shared publications:
Paolo Gerundini
Nuclear Medicine Department, Fondazione IRCCS Ca’ Granda Ospedale Maggiore Policlinico, via Francesco Sforza 35, 20122 Milan, Italy
8 shared publicationsFranco Voltini
Chair of the EANM Technologist Committee Chief Technologist, Radiation Safety Officer Service du Professeur F. Brunotte Centre Georges-François Leclerc Dijon, France
6 shared publicationsFelicia Zito
Nuclear Medicine Department, Fondazione IRCCS Ca' Granda Ospedale Maggiore Policlinico, Milan, Italy
5 shared publicationsEugenio Reschini
3 shared publications- Massimo Castellani
Nuclear Medicine Unit, Fondazione IRCCS Ca’ Granda Ospedale Maggiore Policlinico, 20122 Milan, Italy
3 shared publications Davide Soligo
2 shared publications
Latest Publications
- 11 April 2013
- Published by Springer Nature in European Journal of Nuclear Medicine and Molecular Imaging
- Vol. 40 (7) , 1126-1134
EANM Dosimetry Committee Series on Standard Operational Procedures for Pre-Therapeutic Dosimetry II. Dosimetry prior to radioiodine therapy of benign thyroid diseases
The EANM Dosimetry Committee Series “Standard Operational Procedures for Pre-Therapeutic Dosimetry” (SOP) provides advice to scientists and clinicians on how to perform patient-specific absorbed dose assessments. This particular SOP describes how to tailor the therapeutic activity to be administered for radioiodine therapy of benign thyroid diseases such as Graves’ disease or hyperthyroidism. Pretherapeutic dosimetry is based on the assessment of the individual 131I kinetics in the target tissue after the administration of a tracer activity. The present SOP makes proposals on the equipment to be used and guides the user through the measurements. Time schedules for the measurement of the fractional 131I uptake in the diseased tissue are recommended and it is shown how to calculate from these datasets the therapeutic activity necessary to administer a predefined target dose in the subsequent therapy. Potential sources of error are pointed out and the inherent uncertainties of the procedures depending on the number of measurements are discussed. The theoretical background and the derivation of the listed equations from compartment models of the iodine kinetics are explained in a supplementary file published online only.
- 11 April 2013
- Published by Springer Nature in European Journal of Nuclear Medicine and Molecular Imaging
- Vol. 40 (7) , 1126-1134
EANM Dosimetry Committee Series on Standard Operational Procedures for Pre-Therapeutic Dosimetry II. Dosimetry prior to radioiodine therapy of benign thyroid diseases
The EANM Dosimetry Committee Series “Standard Operational Procedures for Pre-Therapeutic Dosimetry” (SOP) provides advice to scientists and clinicians on how to perform patient-specific absorbed dose assessments. This particular SOP describes how to tailor the therapeutic activity to be administered for radioiodine therapy of benign thyroid diseases such as Graves’ disease or hyperthyroidism. Pretherapeutic dosimetry is based on the assessment of the individual 131I kinetics in the target tissue after the administration of a tracer activity. The present SOP makes proposals on the equipment to be used and guides the user through the measurements. Time schedules for the measurement of the fractional 131I uptake in the diseased tissue are recommended and it is shown how to calculate from these datasets the therapeutic activity necessary to administer a predefined target dose in the subsequent therapy. Potential sources of error are pointed out and the inherent uncertainties of the procedures depending on the number of measurements are discussed. The theoretical background and the derivation of the listed equations from compartment models of the iodine kinetics are explained in a supplementary file published online only.
- 10 August 2012
- Published by Wiley in Medical Physics
- Vol. 39 (9) , 5353-5361
The use of zeolites to generate PET phantoms for the validation of quantification strategies in oncology
Purpose: In recent years, segmentation algorithms and activity quantification methods have been proposed for oncological18F-fluorodeoxyglucose (FDG) PET. A full assessment of these algorithms, necessary for a clinical transfer, requires a validation on data sets provided with a reliable ground truth as to the imaged activity distribution, which must be as realistic as possible. The aim of this work is to propose a strategy to simulate lesions of uniform uptake and irregular shape in an anthropomorphic phantom, with the possibility to easily obtain a ground truth as to lesion activity and borders. Methods: Lesions were simulated with samples of clinoptilolite, a family of natural zeolites of irregular shape, able to absorb aqueous solutions of18F-FDG, available in a wide size range, and nontoxic. Zeolites were soaked in solutions of 18F-FDG for increasing times up to 120 min and their absorptive properties were characterized as function of soaking duration, solution concentration, and zeolite dry weight. Saturated zeolites were wrapped in Parafilm, positioned inside an Alderson thorax–abdomen phantom and imaged with a PET–CT scanner. The ground truth for the activity distribution of each zeolite was obtained by segmenting high-resolution finely aligned CTimages, on the basis of independently obtained volume measurements. The fine alignment between CT and PET was validated by comparing the CT-derived ground truth to a set of zeolites’ PET threshold segmentations in terms of Dice index and volume error. Results: The soaking time necessary to achieve saturation increases with zeolite dry weight, with a maximum of about 90 min for the largest sample. At saturation, a linear dependence of the uptake normalized to the solution concentration on zeolite dry weight (R 2 = 0.988), as well as a uniform distribution of the activity over the entire zeolite volume from PETimaging were demonstrated. These findings indicate that the 18F-FDG solution is able to saturate the zeolite pores and that the concentration does not influence the distribution uniformity of both solution and solute, at least at the trace concentrations used for zeolite activation. An additional proof of uniformity of zeolite saturation was obtained observing a correspondence between uptake and adsorbed volume of solution, corresponding to about 27.8% of zeolite volume. As to the ground truth for zeolites positioned inside the phantom, the segmentation of finely aligned CTimages provided reliable borders, as demonstrated by a mean absolute volume error of 2.8% with respect to the PET threshold segmentation corresponding to the maximum Dice. Conclusions: The proposed methodology allowed obtaining an experimental phantom data set that can be used as a feasible tool to test and validate quantification and segmentation algorithms for PET in oncology. The phantom is currently under consideration for being included in a benchmark designed by AAPM TG211, which will be available to the community to evaluate PET automatic segmentation methods.
- 10 August 2012
- Published by Wiley in Medical Physics
- Vol. 39 (9) , 5353-5361
The use of zeolites to generate PET phantoms for the validation of quantification strategies in oncology
Purpose: In recent years, segmentation algorithms and activity quantification methods have been proposed for oncological18F-fluorodeoxyglucose (FDG) PET. A full assessment of these algorithms, necessary for a clinical transfer, requires a validation on data sets provided with a reliable ground truth as to the imaged activity distribution, which must be as realistic as possible. The aim of this work is to propose a strategy to simulate lesions of uniform uptake and irregular shape in an anthropomorphic phantom, with the possibility to easily obtain a ground truth as to lesion activity and borders. Methods: Lesions were simulated with samples of clinoptilolite, a family of natural zeolites of irregular shape, able to absorb aqueous solutions of18F-FDG, available in a wide size range, and nontoxic. Zeolites were soaked in solutions of 18F-FDG for increasing times up to 120 min and their absorptive properties were characterized as function of soaking duration, solution concentration, and zeolite dry weight. Saturated zeolites were wrapped in Parafilm, positioned inside an Alderson thorax–abdomen phantom and imaged with a PET–CT scanner. The ground truth for the activity distribution of each zeolite was obtained by segmenting high-resolution finely aligned CTimages, on the basis of independently obtained volume measurements. The fine alignment between CT and PET was validated by comparing the CT-derived ground truth to a set of zeolites’ PET threshold segmentations in terms of Dice index and volume error. Results: The soaking time necessary to achieve saturation increases with zeolite dry weight, with a maximum of about 90 min for the largest sample. At saturation, a linear dependence of the uptake normalized to the solution concentration on zeolite dry weight (R 2 = 0.988), as well as a uniform distribution of the activity over the entire zeolite volume from PETimaging were demonstrated. These findings indicate that the 18F-FDG solution is able to saturate the zeolite pores and that the concentration does not influence the distribution uniformity of both solution and solute, at least at the trace concentrations used for zeolite activation. An additional proof of uniformity of zeolite saturation was obtained observing a correspondence between uptake and adsorbed volume of solution, corresponding to about 27.8% of zeolite volume. As to the ground truth for zeolites positioned inside the phantom, the segmentation of finely aligned CTimages provided reliable borders, as demonstrated by a mean absolute volume error of 2.8% with respect to the PET threshold segmentation corresponding to the maximum Dice. Conclusions: The proposed methodology allowed obtaining an experimental phantom data set that can be used as a feasible tool to test and validate quantification and segmentation algorithms for PET in oncology. The phantom is currently under consideration for being included in a benchmark designed by AAPM TG211, which will be available to the community to evaluate PET automatic segmentation methods.
- 1 April 2011
- Published by Wolters Kluwer Health in Journal of Cardiovascular Medicine
- Vol. 12 (4) , 239-248
Myocardial blood flow and infarct size after CD133+ cell injection in large myocardial infarction with good recanalization and poor reperfusion: results from a randomized controlled trial
Large acute ST-elevation myocardial infarction (STEMI) sometimes leaves extensive ischemic damage despite timely and successful primary angioplasty. This clinical picture of good recanalization with incomplete reperfusion represents a good model to assess the reparative potential of locally administered cell therapy. Thus, we conducted a randomized controlled trial aimed at evaluating the effect of intracoronary administration of CD133 stem cells on myocardial blood flow and function in this setting. Fifteen patients with large anterior STEMI, myocardial blush grade 0-1 and more than 50% ST-elevation recovery after optimal coronary recanalization (TIMI 3 flow) with stenting were randomly assigned to receive CD133 cells from either bone marrow (group A) or peripheral blood (group B), or to stay on drug therapy alone (group C). The cells were intracoronary injected within 10-14 days of STEMI. Infarct-related myocardial blood flow (MBF) was evaluated by NH positron emission tomography 2-5 days before cell administration and after 1 year. MBF increased in the infarct area from 0.419 (0.390-0.623) to 0.544 (0.371-0.729) ml/min per g in group A, decreased from 0.547 (0.505-0.683) to 0.295 (0.237-0.472) ml/min per g in group B and only slightly changed from 0.554 (0.413-0.662) to 0.491 (0.453-0.717) ml/min per g in group C (A vs. C: P = 0.023; B vs. C: P = 0.066). Left ventricular volume tended to increase more in groups B and C than in group A, ejection fraction and wall motion score index remained stable in the three groups. These findings support the hypothesis that intracoronary administration of bone marrow-derived, but not peripheral blood-derived CD133 cells 10-14 days after STEMI may improve long-term perfusion.
- 1 April 2011
- Published by Wolters Kluwer Health in Journal of Cardiovascular Medicine
- Vol. 12 (4) , 239-248
Myocardial blood flow and infarct size after CD133+ cell injection in large myocardial infarction with good recanalization and poor reperfusion: results from a randomized controlled trial
Large acute ST-elevation myocardial infarction (STEMI) sometimes leaves extensive ischemic damage despite timely and successful primary angioplasty. This clinical picture of good recanalization with incomplete reperfusion represents a good model to assess the reparative potential of locally administered cell therapy. Thus, we conducted a randomized controlled trial aimed at evaluating the effect of intracoronary administration of CD133 stem cells on myocardial blood flow and function in this setting. Fifteen patients with large anterior STEMI, myocardial blush grade 0-1 and more than 50% ST-elevation recovery after optimal coronary recanalization (TIMI 3 flow) with stenting were randomly assigned to receive CD133 cells from either bone marrow (group A) or peripheral blood (group B), or to stay on drug therapy alone (group C). The cells were intracoronary injected within 10-14 days of STEMI. Infarct-related myocardial blood flow (MBF) was evaluated by NH positron emission tomography 2-5 days before cell administration and after 1 year. MBF increased in the infarct area from 0.419 (0.390-0.623) to 0.544 (0.371-0.729) ml/min per g in group A, decreased from 0.547 (0.505-0.683) to 0.295 (0.237-0.472) ml/min per g in group B and only slightly changed from 0.554 (0.413-0.662) to 0.491 (0.453-0.717) ml/min per g in group C (A vs. C: P = 0.023; B vs. C: P = 0.066). Left ventricular volume tended to increase more in groups B and C than in group A, ejection fraction and wall motion score index remained stable in the three groups. These findings support the hypothesis that intracoronary administration of bone marrow-derived, but not peripheral blood-derived CD133 cells 10-14 days after STEMI may improve long-term perfusion.
- Open Access
- 15 November 2010
- Published by Society of Nuclear Medicine in Journal of Nuclear Medicine
- Vol. 51 (12) , 1908-1916
The Role of PET with 13N-Ammonia and 18F-FDG in the Assessment of Myocardial Perfusion and Metabolism in Patients with Recent AMI and Intracoronary Stem Cell Injection
Over the last decade, the effects of stem cell therapy on cardiac repair after acute myocardial infarction (AMI) have been investigated with different imaging techniques. We evaluated a new imaging approach using 13N-ammonia and 18F-FDG PET for a combined analysis of cardiac perfusion, metabolism, and function in patients treated with intracoronary injection of endothelial progenitors or with conventional therapy for AMI. Methods: A total of 15 patients were randomly assigned to 3 groups based on different treatments (group A: bone marrow–derived stem cells; group B: peripheral blood–derived stem cells; group C: standard therapy alone). The number of scarred and viable segments, along with the infarct size and the extent of the viable area, were determined on a 9-segment 13N-ammonia/18F-FDG PET polar map. Myocardial blood flow (MBF) was calculated for each segment on the ammonia polar map, whereas a global evaluation of left ventricular function was obtained by estimating left ventricular ejection fraction (LVEF) and end-diastolic volume, both derived from electrocardiography-gated 18F-FDG images. Both intragroup and intergroup comparative analyses of the mean values of each parameter were performed at baseline and 3, 6, and 12 mo after AMI. During follow-up, major cardiac events were also registered. Results: A significant decrease (P < 0.05) in the number of scarred segments and infarct size was observed in group A, along with an increase in MBF (P < 0.05) and a mild improvement in cardiac function. Lack of infarct size shrinkage in group B was associated with a marked impairment of MBF (P = 0.01) and cardiac dysfunction. Ambiguous changes in infarct size, MBF, and LVEF were found in group C. No differences in number of viable segments or in extent of viable area were found among the groups. At clinical follow-up, no major cardiac events occurred in group A patients, whereas 2 patients of group B experienced in-stent occlusion and one patient of group C received a transplant for heart failure. Conclusion: Our data suggest that a single nuclear imaging technique accurately analyzes changes in myocardial perfusion and metabolism occurring after stem cell transplantation.
- 15 November 2010
- Published by Society of Nuclear Medicine in Journal of Nuclear Medicine
- Vol. 51 (12) , 1908-1916
Open AccessThe Role of PET with 13N-Ammonia and 18F-FDG in the Assessment of Myocardial Perfusion and Metabolism in Patients with Recent AMI and Intracoronary Stem Cell Injection
Over the last decade, the effects of stem cell therapy on cardiac repair after acute myocardial infarction (AMI) have been investigated with different imaging techniques. We evaluated a new imaging approach using 13N-ammonia and 18F-FDG PET for a combined analysis of cardiac perfusion, metabolism, and function in patients treated with intracoronary injection of endothelial progenitors or with conventional therapy for AMI. Methods: A total of 15 patients were randomly assigned to 3 groups based on different treatments (group A: bone marrow–derived stem cells; group B: peripheral blood–derived stem cells; group C: standard therapy alone). The number of scarred and viable segments, along with the infarct size and the extent of the viable area, were determined on a 9-segment 13N-ammonia/18F-FDG PET polar map. Myocardial blood flow (MBF) was calculated for each segment on the ammonia polar map, whereas a global evaluation of left ventricular function was obtained by estimating left ventricular ejection fraction (LVEF) and end-diastolic volume, both derived from electrocardiography-gated 18F-FDG images. Both intragroup and intergroup comparative analyses of the mean values of each parameter were performed at baseline and 3, 6, and 12 mo after AMI. During follow-up, major cardiac events were also registered. Results: A significant decrease (P < 0.05) in the number of scarred segments and infarct size was observed in group A, along with an increase in MBF (P < 0.05) and a mild improvement in cardiac function. Lack of infarct size shrinkage in group B was associated with a marked impairment of MBF (P = 0.01) and cardiac dysfunction. Ambiguous changes in infarct size, MBF, and LVEF were found in group C. No differences in number of viable segments or in extent of viable area were found among the groups. At clinical follow-up, no major cardiac events occurred in group A patients, whereas 2 patients of group B experienced in-stent occlusion and one patient of group C received a transplant for heart failure. Conclusion: Our data suggest that a single nuclear imaging technique accurately analyzes changes in myocardial perfusion and metabolism occurring after stem cell transplantation.
- 19 February 2010
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 139 (1-3) , 232-235
Investigation of biokinetics of radioiodine with a population kinetics approach
The dosimetric studies required for planning individually tailored radioiodine therapy of benign thyroid pathologies may be too complex and time-demanding for many ordinary nuclear medicine departments. In this work, a preliminary population kinetics approach was applied to a model structure for iodine biokinetics in order to identify those model features that actually need to be individually investigated, in order to simplify the protocol for data collection in patients. Data from 29 patients undergoing radioiodine therapy for the treatment of the autonomous nodule syndrome were used in the analysis. The greatest inter-individual variations were observed in the parameters describing the transformation of iodide into organic iodine in the thyroid and in the kinetics of the organic form.
- 19 February 2010
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 139 (1-3) , 232-235
Investigation of biokinetics of radioiodine with a population kinetics approach
The dosimetric studies required for planning individually tailored radioiodine therapy of benign thyroid pathologies may be too complex and time-demanding for many ordinary nuclear medicine departments. In this work, a preliminary population kinetics approach was applied to a model structure for iodine biokinetics in order to identify those model features that actually need to be individually investigated, in order to simplify the protocol for data collection in patients. Data from 29 patients undergoing radioiodine therapy for the treatment of the autonomous nodule syndrome were used in the analysis. The greatest inter-individual variations were observed in the parameters describing the transformation of iodide into organic iodine in the thyroid and in the kinetics of the organic form.
- Open Access
- 1 October 2007
- Published by European Association of Nuclear Medicine
Best Practice in Nuclear Medicine 2
- 1 October 2007
- Published by European Association of Nuclear Medicine
Open AccessBest Practice in Nuclear Medicine 2
- 1 February 2007
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 571 (1-2) , 493-497
Analysis of different detector and electronics defects on F18-FDG images
- 1 February 2007
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 571 (1-2) , 493-497
Analysis of different detector and electronics defects on F18-FDG images
- 24 July 2006
- Published by Wiley in Medical Physics
- Vol. 33 (8) , 2860-2867
Verification of the agreement of two dosimetric methods with radioiodine therapy in hyperthyroid patients
The aim of this study was to verify the capability of an MIRD formula-based dosimetric method to predict radioiodine kinetics (fraction of administered iodine transferred to the thyroid, U0, and effective clearance rate, lambda(eff)) and absorbed dose after oral therapeutic 131I administration. The method is based on 123I intravenous administration and five subsequent gamma camera measured uptake values determined separately on different structures within the thyroid. Another dosimetric method based on only the 123I 24-h uptake and a fixed lambda(eff) value was also considered. Eighty-nine hyperthyroid patients (10 with Graves' disease and 79 with autonomously functioning nodules) were studied and 132 thyroidal structures were evaluated. The mean time interval between dosimetry and therapy was 20 +/- 10d. Uptake values were measured at 2, 4, 24, 48, and 120 h during dosimetry and at 2, 4, 24, 48, 96, and 168 h during therapy. The value 0.125d(-1) was chosen in the fixed-lambda(eff) method. The planned doses to the target ranged from 120 to 250 Gy depending on the type and severity of hyperthyroidism. The following significant correlations between therapeutic and dosimetric parameters were found: U0(ther)=0.88U0(dos) (r=0.97,p<0.01), lambda(eff)ther = 1.01 lambda(eff)dos (r=0.85,p<0.01), and D(estimated)= 0.85D(planned) (r=0.88, p<0.01). The percent difference between U0(ther) and U0(dos) ranged from -44 to 32% and between lambda(eff)ther and lambda(eff)dos from -32 to 48%. U0(ther) was lower than U0(dos) in 74% of cases: this can be explained by the self-stunning effect of 131I therapeutic activity that produced a dose of about 20 Gy with a maximum dose rate of 0.6 Gy/h over the initial 24-48 h. The differences, deltaD, between the estimated and the planned doses ranged from -42% (-87 Gy) to 32% (59 Gy); in 73% of cases the difference was within +/- 35 Gy. Greater discrepancies were found with the fixed-lambda(eff) method, in which deltaD ranged from -69 to 95% (-202 to 88 Gy, respectively). In hyperthyroid patients, the five uptake value dosimetric method is able to predict with a good agreement the radioiodine kinetics and the dose after the therapeutic administration in about 73% of the analyzed thyroid structures. The fixed-lambda(eff) method is less reliable.
- 24 July 2006
- Published by Wiley in Medical Physics
- Vol. 33 (8) , 2860-2867
Verification of the agreement of two dosimetric methods with radioiodine therapy in hyperthyroid patients
The aim of this study was to verify the capability of an MIRD formula-based dosimetric method to predict radioiodine kinetics (fraction of administered iodine transferred to the thyroid, U0, and effective clearance rate, lambda(eff)) and absorbed dose after oral therapeutic 131I administration. The method is based on 123I intravenous administration and five subsequent gamma camera measured uptake values determined separately on different structures within the thyroid. Another dosimetric method based on only the 123I 24-h uptake and a fixed lambda(eff) value was also considered. Eighty-nine hyperthyroid patients (10 with Graves' disease and 79 with autonomously functioning nodules) were studied and 132 thyroidal structures were evaluated. The mean time interval between dosimetry and therapy was 20 +/- 10d. Uptake values were measured at 2, 4, 24, 48, and 120 h during dosimetry and at 2, 4, 24, 48, 96, and 168 h during therapy. The value 0.125d(-1) was chosen in the fixed-lambda(eff) method. The planned doses to the target ranged from 120 to 250 Gy depending on the type and severity of hyperthyroidism. The following significant correlations between therapeutic and dosimetric parameters were found: U0(ther)=0.88U0(dos) (r=0.97,p<0.01), lambda(eff)ther = 1.01 lambda(eff)dos (r=0.85,p<0.01), and D(estimated)= 0.85D(planned) (r=0.88, p<0.01). The percent difference between U0(ther) and U0(dos) ranged from -44 to 32% and between lambda(eff)ther and lambda(eff)dos from -32 to 48%. U0(ther) was lower than U0(dos) in 74% of cases: this can be explained by the self-stunning effect of 131I therapeutic activity that produced a dose of about 20 Gy with a maximum dose rate of 0.6 Gy/h over the initial 24-48 h. The differences, deltaD, between the estimated and the planned doses ranged from -42% (-87 Gy) to 32% (59 Gy); in 73% of cases the difference was within +/- 35 Gy. Greater discrepancies were found with the fixed-lambda(eff) method, in which deltaD ranged from -69 to 95% (-202 to 88 Gy, respectively). In hyperthyroid patients, the five uptake value dosimetric method is able to predict with a good agreement the radioiodine kinetics and the dose after the therapeutic administration in about 73% of the analyzed thyroid structures. The fixed-lambda(eff) method is less reliable.
- 10 November 2004
- Published by Wiley in Medical Physics
- Vol. 31 (12) , 3194-3200
Potential third‐party radiation exposure from outpatients treated with for hyperthyroidism
Thirty‐three hyperthyroid patients treated with radioiodine (mean administered activity 414 MBq, range 163–555) were studied to determine if pretreatment dosimetry could be used to give radiation protection advice that could assure compliance with the effective dose constraints suggested by the European Commission. Effective doses to travelers, co‐workers, and sleeping partners were estimated by integrating the effective dose rate‐versus‐time curve obtained by fitting the dose rates measured several times after radioiodine administration to a biexponential function. The mean estimated effective doses to travelers, co‐workers, and sleeping partners were 0.11 mSv (0.05–0.24), 0.24 mSv (0.07–0.52), and 1.8 mSv (0.6–4.1), respectively. The best correlation was found between effective dose in mSv and maximum activity in MBq taken up in the thyroid: ; ; . Private/public transports are always allowed. For the co‐workers the effective dose constraint of 0.3 mSv is met without restrictions and with 3 days off work if is lower or higher than 185 MBq, respectively. For the sleeping partners the effective dose constraint of 3 mSv is met without restriction and with 4 nights separate sleeping arrangements if is lower or higher than 185 MBq, respectively. The potential for contamination by the patients was determined from perspiration samples taken from the patient's hands, forehead, and neck and in saliva at 4, 24, and 48 h after radioiodine treatment. The mean highest activity levels for hands, forehead, neck, and saliva were , and , respectively. The results indicate that there is minimal risk of contamination from these patients.
- 10 November 2004
- Published by Wiley in Medical Physics
- Vol. 31 (12) , 3194-3200
Potential third‐party radiation exposure from outpatients treated with for hyperthyroidism
Thirty‐three hyperthyroid patients treated with radioiodine (mean administered activity 414 MBq, range 163–555) were studied to determine if pretreatment dosimetry could be used to give radiation protection advice that could assure compliance with the effective dose constraints suggested by the European Commission. Effective doses to travelers, co‐workers, and sleeping partners were estimated by integrating the effective dose rate‐versus‐time curve obtained by fitting the dose rates measured several times after radioiodine administration to a biexponential function. The mean estimated effective doses to travelers, co‐workers, and sleeping partners were 0.11 mSv (0.05–0.24), 0.24 mSv (0.07–0.52), and 1.8 mSv (0.6–4.1), respectively. The best correlation was found between effective dose in mSv and maximum activity in MBq taken up in the thyroid: ; ; . Private/public transports are always allowed. For the co‐workers the effective dose constraint of 0.3 mSv is met without restrictions and with 3 days off work if is lower or higher than 185 MBq, respectively. For the sleeping partners the effective dose constraint of 3 mSv is met without restriction and with 4 nights separate sleeping arrangements if is lower or higher than 185 MBq, respectively. The potential for contamination by the patients was determined from perspiration samples taken from the patient's hands, forehead, and neck and in saliva at 4, 24, and 48 h after radioiodine treatment. The mean highest activity levels for hands, forehead, neck, and saliva were , and , respectively. The results indicate that there is minimal risk of contamination from these patients.
- 21 April 2003
- Published by Wiley in Medical Physics
- Vol. 30 (5) , 791-798
Tissue-specific dosimetry for radioiodine therapy of the autonomous thyroid nodule
A tissue-specific dosimetric method based on gamma camera acquisitions was developed to determine the 131I activity to administer to patients with autonomous thyroid nodules (ATN) to deliver 200 Gy to the nodule and to evaluate the correspondent dose to extranodular tissue. Twenty patients with ATN were given 111 MBq of 123I i.v. and their neck was imaged 2, 4, 24, 48, and 120 hours after administration to evaluate separate iodine kinetics for nodule and contralateral lobe. The volumes of nodule and lobe were measured on the 4 hour scintigraphic image, after optimization of the method on a thyroid phantom. Three simplified dosimetric methods were then considered and compared to the reference method in terms of 131I activity: (a) three point method, based on 4, 24, and 120 h acquisitions, (b) fixed T1/2 method, that measures only the 24 h uptake and assumes an effective half-life of 5 days for the nodule, (c) fixed activity method, based on the administration of 413 MBq of 131I. The mean 131I activity to administer to the 20 patients was 413 MBq (range 65-1327) and the mean dose to the contralateral lobe was 43 Gy (range 11-121). The percentage differences in 131I activity between the reference method and the simplified methods were in the ranges: (a) -14%, 13%, (b) -42%, 74%, (c) -69%, 533%. The relevant dose to extranodular tissue and the great interpatient variability of the radioiodine activity required to give a predetermined dose to ATN suggest that a tissue specific dosimetric approach based on gamma camera acquisitions is fundamental. A simple method based on only three uptake measurements is a reliable alternative to the five point method when the clinical workload of a Nuclear Medicine department is particularly heavy.
- 21 April 2003
- Published by Wiley in Medical Physics
- Vol. 30 (5) , 791-798
Tissue-specific dosimetry for radioiodine therapy of the autonomous thyroid nodule
A tissue-specific dosimetric method based on gamma camera acquisitions was developed to determine the 131I activity to administer to patients with autonomous thyroid nodules (ATN) to deliver 200 Gy to the nodule and to evaluate the correspondent dose to extranodular tissue. Twenty patients with ATN were given 111 MBq of 123I i.v. and their neck was imaged 2, 4, 24, 48, and 120 hours after administration to evaluate separate iodine kinetics for nodule and contralateral lobe. The volumes of nodule and lobe were measured on the 4 hour scintigraphic image, after optimization of the method on a thyroid phantom. Three simplified dosimetric methods were then considered and compared to the reference method in terms of 131I activity: (a) three point method, based on 4, 24, and 120 h acquisitions, (b) fixed T1/2 method, that measures only the 24 h uptake and assumes an effective half-life of 5 days for the nodule, (c) fixed activity method, based on the administration of 413 MBq of 131I. The mean 131I activity to administer to the 20 patients was 413 MBq (range 65-1327) and the mean dose to the contralateral lobe was 43 Gy (range 11-121). The percentage differences in 131I activity between the reference method and the simplified methods were in the ranges: (a) -14%, 13%, (b) -42%, 74%, (c) -69%, 533%. The relevant dose to extranodular tissue and the great interpatient variability of the radioiodine activity required to give a predetermined dose to ATN suggest that a tissue specific dosimetric approach based on gamma camera acquisitions is fundamental. A simple method based on only three uptake measurements is a reliable alternative to the five point method when the clinical workload of a Nuclear Medicine department is particularly heavy.