Qingen Meng
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Qingen Meng has a total of 47 co-authors. Here are the top co-authors by number of shared publications:
Zhongmin Jin
9 shared publicationsJohn Fisher
Institute of Medical and Biological Engineering, School of Mechanical Engineering, University of Leeds, Leeds, UK
8 shared publications- Zhongmin Jin
School of Mechanical Engineering Southwest Jiaotong University 610031 Chengdu China
5 shared publications Feng Liu
4 shared publications- Ruth K. Wilcox
Institute of Medical and Biological Engineering, University of Leeds, Leeds LS2 9JT, UK
4 shared publications F Liu
Institute of Medical and Biological Engineering, School of Mechanical Engineering, University of Leeds, Leeds, UK
3 shared publications
Latest Publications
- 31 December 2025
- Published by Elsevier in Tribology International
- Vol. 217
Effects of solid viscoelasticity and loading rates on the squeeze film lubrication towards polymer-based materials: A numerical study
- 31 December 2025
- Published by Elsevier in Tribology International
- Vol. 217
Effects of solid viscoelasticity and loading rates on the squeeze film lubrication towards polymer-based materials: A numerical study
- Open Access
- 18 March 2025
- Published by MDPI AG in Lubricants
- Vol. 13 (3) , 131
Effects of Gait Patterns on the Viscoelastic Squeeze-Film Lubrication of Hip Replacements
The present study investigated the influence of various gait patterns on the viscoelastic squeeze-film lubrication characteristics of UHMWPE-based artificial hip replacements. Different gait loads (slow walking, normal walking, slow running) measured by Bergmann et al. were adopted in the present lubrication simulation. A comprehensive squeeze-film lubrication model for UHMWPE hip replacement was developed and numerically solved to determine the spatial distributions of film thickness and pressure profiles. The results showed that physiological loads had a negligible impact on the minimum film thicknesses during the stand phases. However, they significantly enhanced the minimum film thicknesses in both the elastic (1.16–1.31 times) and viscoelastic models (1.43–2.85 times) during the swing phases when compared to constant loads. This improvement was notably more pronounced in the viscoelastic model than in the elastic model. The slow-running gait, characterized by its higher frequency, demonstrated a more pronounced enhancement in squeeze-film lubrication of UHMWPE artificial hip joints compared to both normal-walking and slow-walking gaits. Specifically, the minimum film thicknesses during slow running were found to be 1.15 to 1.35 times greater than those observed during normal walking and 1.33 to 1.66 times greater than those during slow walking, highlighting the superior lubrication performance in the slow running case.
- 18 March 2025
- Published by MDPI AG in Lubricants
- Vol. 13 (3) , 131
Open AccessEffects of Gait Patterns on the Viscoelastic Squeeze-Film Lubrication of Hip Replacements
The present study investigated the influence of various gait patterns on the viscoelastic squeeze-film lubrication characteristics of UHMWPE-based artificial hip replacements. Different gait loads (slow walking, normal walking, slow running) measured by Bergmann et al. were adopted in the present lubrication simulation. A comprehensive squeeze-film lubrication model for UHMWPE hip replacement was developed and numerically solved to determine the spatial distributions of film thickness and pressure profiles. The results showed that physiological loads had a negligible impact on the minimum film thicknesses during the stand phases. However, they significantly enhanced the minimum film thicknesses in both the elastic (1.16–1.31 times) and viscoelastic models (1.43–2.85 times) during the swing phases when compared to constant loads. This improvement was notably more pronounced in the viscoelastic model than in the elastic model. The slow-running gait, characterized by its higher frequency, demonstrated a more pronounced enhancement in squeeze-film lubrication of UHMWPE artificial hip joints compared to both normal-walking and slow-walking gaits. Specifically, the minimum film thicknesses during slow running were found to be 1.15 to 1.35 times greater than those observed during normal walking and 1.33 to 1.66 times greater than those during slow walking, highlighting the superior lubrication performance in the slow running case.
- Open Access
- 19 October 2023
- Published by MDPI AG in Lubricants
- Vol. 11 (10) , 451
Effects of Oil Supply Condition on Spinning–Sliding EHL
An optical interference test rig with spinning elastohydrodynamic lubrication (EHL) was established to investigate the spinning lubrication performance under different oil-supply conditions. Variations in the shape and thickness of the film versus the velocity, the load, and the spinning factor under fully flooded lubrication were discussed, and the effects of the inlet-starvation position and oil-supply quantity were analyzed. The results show that the symmetry for the classical horseshoe shape does not exist under both spinning–rolling and spinning–sliding EHL conditions. Different from spinning–rolling, a dimple is generated more easily under the spinning–sliding condition. The dimple is related to the load and the speed. The effects of the inlet-starvation position on spinning EHL are different. When the inlet starvation is on the low-speed side of the contact, that is, proximal to the center of rotation, the inlet-starvation position extends from the proximal side to the center of rotation to the distal side to the center of rotation, i.e., the high-speed side of the contact, which is starved easily. When the starvation happens on the high-speed side, i.e., distal to the center of rotation, the starvation at this position becomes much more severe, and lubrication failure and a risk of wear will occur. In addition, the effects of oil-supply quantity on spinning EHL are important.
- 19 October 2023
- Published by MDPI AG in Lubricants
- Vol. 11 (10) , 451
Open AccessEffects of Oil Supply Condition on Spinning–Sliding EHL
An optical interference test rig with spinning elastohydrodynamic lubrication (EHL) was established to investigate the spinning lubrication performance under different oil-supply conditions. Variations in the shape and thickness of the film versus the velocity, the load, and the spinning factor under fully flooded lubrication were discussed, and the effects of the inlet-starvation position and oil-supply quantity were analyzed. The results show that the symmetry for the classical horseshoe shape does not exist under both spinning–rolling and spinning–sliding EHL conditions. Different from spinning–rolling, a dimple is generated more easily under the spinning–sliding condition. The dimple is related to the load and the speed. The effects of the inlet-starvation position on spinning EHL are different. When the inlet starvation is on the low-speed side of the contact, that is, proximal to the center of rotation, the inlet-starvation position extends from the proximal side to the center of rotation to the distal side to the center of rotation, i.e., the high-speed side of the contact, which is starved easily. When the starvation happens on the high-speed side, i.e., distal to the center of rotation, the starvation at this position becomes much more severe, and lubrication failure and a risk of wear will occur. In addition, the effects of oil-supply quantity on spinning EHL are important.
- Open Access
- 27 September 2022
- Published by MDPI AG in Lubricants
- Vol. 10 (10) , 238
Lubrication Modelling of Artificial Joint Replacements: Current Status and Future Challenges
This paper reviews the recent advancements in computational modelling of the lubrication of hip and knee joint replacements, especially those concerning Professor Duncan Dowson’s contribution. The review starts with the development of modelling the five key parameters that appeared in the pioneered Hamrock–Dowson formula. Then, the theory and approaches for the mixed lubrication in which the artificial hip and knee joint replacements operate are reviewed. We also discuss the current challenges in modelling the lubrication behaviour of joint replacements and how these challenges could be addressed in future studies. These challenges include the mixed lubrication theory, the numerical complexities due to complicated realistic geometry, material and rheology, and individual physiological diversities.
- 27 September 2022
- Published by MDPI AG in Lubricants
- Vol. 10 (10) , 238
Open AccessLubrication Modelling of Artificial Joint Replacements: Current Status and Future Challenges
This paper reviews the recent advancements in computational modelling of the lubrication of hip and knee joint replacements, especially those concerning Professor Duncan Dowson’s contribution. The review starts with the development of modelling the five key parameters that appeared in the pioneered Hamrock–Dowson formula. Then, the theory and approaches for the mixed lubrication in which the artificial hip and knee joint replacements operate are reviewed. We also discuss the current challenges in modelling the lubrication behaviour of joint replacements and how these challenges could be addressed in future studies. These challenges include the mixed lubrication theory, the numerical complexities due to complicated realistic geometry, material and rheology, and individual physiological diversities.
- 1 July 2021
- Published by Elsevier in Computer Methods and Programs in Biomedicine
- Vol. 206, 106122
The effect of highly inhomogeneous biphasic properties on mechanical behaviour of articular cartilage
- 1 July 2021
- Published by Elsevier in Computer Methods and Programs in Biomedicine
- Vol. 206, 106122
The effect of highly inhomogeneous biphasic properties on mechanical behaviour of articular cartilage
- Open Access
- 1 December 2018
- Published by Elsevier in Tribology International
- Vol. 128, 271-278
Transient viscoelastic lubrication analyses of UHMWPE hip replacements
- 1 December 2018
- Published by Elsevier in Tribology International
- Vol. 128, 271-278
Open AccessTransient viscoelastic lubrication analyses of UHMWPE hip replacements
- Open Access
- 9 August 2017
- Published by The Royal Society in Royal Society Open Science
- Vol. 4 (8) , 170670
The effects of geometric uncertainties on computational modelling of knee biomechanics
The geometry of the articular components of the knee is an important factor in predicting joint mechanics in computational models. There are a number of uncertainties in the definition of the geometry of cartilage and meniscus, and evaluating the effects of these uncertainties is fundamental to understanding the level of reliability of the models. In this study, the sensitivity of knee mechanics to geometric uncertainties was investigated by comparing polynomial-based and image-based knee models and varying the size of meniscus. The results suggested that the geometric uncertainties in cartilage and meniscus resulting from the resolution of MRI and the accuracy of segmentation caused considerable effects on the predicted knee mechanics. Moreover, even if the mathematical geometric descriptors can be very close to the imaged-based articular surfaces, the detailed contact pressure distribution produced by the mathematical geometric descriptors was not the same as that of the image-based model. However, the trends predicted by the models based on mathematical geometric descriptors were similar to those of the imaged-based models.
- 9 August 2017
- Published by The Royal Society in Royal Society Open Science
- Vol. 4 (8) , 170670
Open AccessThe effects of geometric uncertainties on computational modelling of knee biomechanics
The geometry of the articular components of the knee is an important factor in predicting joint mechanics in computational models. There are a number of uncertainties in the definition of the geometry of cartilage and meniscus, and evaluating the effects of these uncertainties is fundamental to understanding the level of reliability of the models. In this study, the sensitivity of knee mechanics to geometric uncertainties was investigated by comparing polynomial-based and image-based knee models and varying the size of meniscus. The results suggested that the geometric uncertainties in cartilage and meniscus resulting from the resolution of MRI and the accuracy of segmentation caused considerable effects on the predicted knee mechanics. Moreover, even if the mathematical geometric descriptors can be very close to the imaged-based articular surfaces, the detailed contact pressure distribution produced by the mathematical geometric descriptors was not the same as that of the image-based model. However, the trends predicted by the models based on mathematical geometric descriptors were similar to those of the imaged-based models.
- Open Access
- 1 January 2017
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 65, 439-453
The effect of collagen fibril orientation on the biphasic mechanics of articular cartilage
- 1 January 2017
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 65, 439-453
Open AccessThe effect of collagen fibril orientation on the biphasic mechanics of articular cartilage
- Open Access
- 1 October 2015
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 50, 70-76
The lubrication performance of the ceramic-on-ceramic hip implant under starved conditions
- 1 October 2015
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 50, 70-76
Open AccessThe lubrication performance of the ceramic-on-ceramic hip implant under starved conditions
- Open Access
- 1 January 2015
- Published by Japan Institute of Metals in MATERIALS TRANSACTIONS
- Vol. 56 (6) , 826-834
Analysis of Run-in-Stage Wear Behavior and Contact Mechanics of Metal-on-Metal Hip Joint Bearings with Different Radial Clearances
Japan's largest platform for academic e-journals: J-STAGE is a full text database for reviewed academic papers published by Japanese societies
- 1 January 2015
- Published by Japan Institute of Metals in MATERIALS TRANSACTIONS
- Vol. 56 (6) , 826-834
Open AccessAnalysis of Run-in-Stage Wear Behavior and Contact Mechanics of Metal-on-Metal Hip Joint Bearings with Different Radial Clearances
Japan's largest platform for academic e-journals: J-STAGE is a full text database for reviewed academic papers published by Japanese societies