Muhaimin Mohd Fadzil
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Muhaimin Mohd Fadzil has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Dyah Ekashanti Octorina Dewi
Universiti Teknologi Malaysia
2 shared publications - Eko Supriyanto
Universiti Teknologi Malaysia
2 shared publications Mohamad Amir Shamsudin
2 shared publicationsA. A. M. Faudzi
Control and Mechatronics Engineering Department, Faculty of Electrical Engineering, Universiti Teknologi Malaysia:Center for Artificial Intelligence and Robotics (CAIRO), Universiti Teknologi Malaysia
1 shared publicationAbdul Aziz Abdul Satar
Control and Mechatronics Engineering Department, Faculty of Electrical Engineering, Universiti Teknologi Malaysia, 81310 UTM Johor Bahru, Johor, Malaysia
1 shared publicationAhmad 'Athif Mohd Faudzi
Centre for Artificial Intelligent and Robotics, Universiti Teknologi Malaysia, 81310 UTM Johor Bahru, Johor, Malaysia
1 shared publication
Latest Publications
- 1 October 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 55-59
Design, simulation, and kinematic analysis of a manipulator-based 3D position tracking system
In recent decades, the use of three-dimensional ultrasound (3DUS) imaging of organs has been growing rapidly compared to its two-dimensional ultrasound (2DUS) type. The use of freehand technique in 3DUS system may help to improve the natural flexibility performance. To realize a 3DUS freehand imaging, a position tracking system which measures the US probe position in real time is added. The design, simulation, and analysis of a new 6 degree-of-freedom (6DOF) manipulator-based position tracking system for 3DUS probe are presented in this paper. The forward kinematics of the manipulator was calculated using the Denavit-Hartenberg (D-H) convention. The position of end-effector, which represented the US probe position, was then measured using the joint parameters. The mathematical equations were then verified using Robotic Toolbox in MATLAB as the simulation software. The results of both simulation and equation verified the validity of the kinematic equations.
- 1 October 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 55-59
Design, simulation, and kinematic analysis of a manipulator-based 3D position tracking system
In recent decades, the use of three-dimensional ultrasound (3DUS) imaging of organs has been growing rapidly compared to its two-dimensional ultrasound (2DUS) type. The use of freehand technique in 3DUS system may help to improve the natural flexibility performance. To realize a 3DUS freehand imaging, a position tracking system which measures the US probe position in real time is added. The design, simulation, and analysis of a new 6 degree-of-freedom (6DOF) manipulator-based position tracking system for 3DUS probe are presented in this paper. The forward kinematics of the manipulator was calculated using the Denavit-Hartenberg (D-H) convention. The position of end-effector, which represented the US probe position, was then measured using the joint parameters. The mathematical equations were then verified using Robotic Toolbox in MATLAB as the simulation software. The results of both simulation and equation verified the validity of the kinematic equations.
- 7 May 2015
- Published by Springer Nature
- p. 57-89
Position Tracking Systems for Ultrasound Imaging: A Survey
- 7 May 2015
- Published by Springer Nature
- p. 57-89
Position Tracking Systems for Ultrasound Imaging: A Survey
- 5 January 2015
- Published by Penerbit UTM Press in Jurnal Teknologi (Sciences & Engineering)
- Vol. 72 (2)
Structural Analysis of Portable Repositioning Equipment for Bedridden Patients
A new approach of preventing bedsore risk for bedridden patients is presented. The design is proposed by transferring the conventional method into a portable mechanism that was derived from popular nurses’ practice using bed sheet to relieve patient skin pressure by repositioning or rolling them every 2 hours. The portable equipment is installed in between the bed to reposition the patient. In this paper, the development of prototype design is addressed, followed by the simulation of structure stress analysis and software development. This study will match the proposed design with the behavior of its user.
- 5 January 2015
- Published by Penerbit UTM Press in Jurnal Teknologi (Sciences & Engineering)
- Vol. 72 (2)
Structural Analysis of Portable Repositioning Equipment for Bedridden Patients
A new approach of preventing bedsore risk for bedridden patients is presented. The design is proposed by transferring the conventional method into a portable mechanism that was derived from popular nurses’ practice using bed sheet to relieve patient skin pressure by repositioning or rolling them every 2 hours. The portable equipment is installed in between the bed to reposition the patient. In this paper, the development of prototype design is addressed, followed by the simulation of structure stress analysis and software development. This study will match the proposed design with the behavior of its user.
- 1 January 2015
- Published by Japan Society of Mechanical Engineers in The Abstracts of the international conference on advanced mechatronics : toward evolutionary fusion of IT and mechatronics : ICAM
- Vol. 2015.6, 108-109
Manipulator-based Position Tracking System for Freehand 3D Ultrasound Imaging : IMU Sensor Analysis and Experiment
- 1 January 2015
- Published by Japan Society of Mechanical Engineers in The Abstracts of the international conference on advanced mechatronics : toward evolutionary fusion of IT and mechatronics : ICAM
- Vol. 2015.6, 108-109
Manipulator-based Position Tracking System for Freehand 3D Ultrasound Imaging : IMU Sensor Analysis and Experiment