AJAlexander Jönsson

Alexander Jönsson

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Alexander Jönsson has a total of 34 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    ChipNMR: Hyperpolarized NMR for non-invasive metabolic flux analysis in perfused microfluidic chips

    by Thomas B. Wareham-Mathiassen, Juan D. Sánchez-Heredia, Ke-Chuan Wang, Cajsa R. Haupt, Magnus Karlsson, Alexander Jönsson, Martin Dufva, Roland Thuenauer, Pernille Rose Jensen

    Dissolution dynamic nuclear polarization NMR Spectroscopy (dDNP-NMR) has become a transformative tool for metabolic studies by significantly enhancing signal sensitivity more than three orders of magnitude compared to traditional NMR. However, NMR detection probes are optimized for round narrow glass tubes typically 5 mm in diameter, which impose constraints on their utility for metabolic studies of adhernt cells. Here, we present a novel NMR probe head integrated with a custom microfluidic chip that facilitates real-time monitoring of hyperpolarized substrate conversion from adhernt cells. This system enables metabolic flux analysis in a controlled, in vitro environment, as demonstrated by tracking the conversion of [1- 13 C] pyruvate to [1- 13 C] lactate in HeLa cells over 48 hours. To the best of our knowledge, this is the first demonstration of cell metabolism from an adhering monolayer of mammalian cells in combination with hyperpolarized NMR. The custom microfluidic chip design is modular and adaptable allowing expansion to dual-chamber chips, demonstrating its potential in applications for more complex cellular environments, such as Organ-on-a-Chip systems.


  • Open Access

    Enhanced biocompatibility of 3D printed resin parts via wet autoclave postprocessing: implications for stem cell organ-on-a-chip culture

    by Alexander Jönsson, Antonia Iatrou, Louise Wildfang, Dana J. Neumann, Hakan Gürbüz, Carina A. A. Schoenmaker, Marlene Danner Dalgaard, Pernille Rose Jensen, Martin Dufva

    Water autoclaved resin 3D prints leach less material, which correlates with improved biocompatibility. Differential gene expression indicates the suppression of extracellular matrix proteins.


  • Open Access

    Tissue Like Density Sheets of Hepatoblastoma Cultures Obtained with Thin Suspended Hydrogels Mimicking In Vivo Inter‐Capillary Distances

    by Alexander Jönsson, Hakan Gürbüz, Louise Wildfang, Pernille Rose Jensen, Martin Dufva

    Here a fabrication method is demonstrated that allows for the production of hydrogels in the ranges of 50–500 µm, suspended in polystyrene (PS) inserts, to mimic various inter‐capillary in vivo distances. The inherent thinning properties of vacuum forming, together with liquid pinning in apertures, are utilized to reproducibly obtain suspended gels with controlled thicknesses down to ≈50 µm. Transport through the gels is simulated for two model compounds and 50 µm gels are shown to allow for up to three times higher basolateral concentration than for 500 µm gels, after 1 h. HepG2 cells, encased in 50 µm gels, grow to cell densities of 1000 ± 400 million cells mL−1, that is, close to in vivo tissue densities. By contrast, 200 and 500 µm gels support cell densities of 180 and 50 million cells mL−1, respectively. The observed maximum cell densities correlate with expected cell densities, estimated by simulation of O2 diffusion and metabolism. In conclusion, thin suspended hydrogels provide means to mimic a variety of inter‐capillary distances and enable the development of high‐density cell cultures.


  • Open Access

    Standalone single- and bi-layered human skin 3D models supported by recombinant silk feature native spatial organization

    by Savvini Gkouma, Nayanika Bhalla, Solène Frapard, Alexander Jönsson, Hakan Gürbüz, Asli Aybike Dogan, Stefania Giacomello, Martin Duvfa, Patrik L Ståhl, Mona Widhe, et al.

    Physiologically relevant human skin models that include key skin cell types can be used for in vitro drug testing, skin pathology studies, or clinical applications such as skin grafts. However, there is still no golden standard for such a model. We investigated the potential of a recombinant functionalized spider silk protein, FN-silk, for the construction of a dermal, an epidermal, and a bilayered skin equivalent (BSE). Specifically, two formats of FN-silk (i.e. 3D network and nanomembrane) were evaluated. The 3D network was used as an elastic ECM-like support for the dermis, and the thin, permeable nanomembrane was used as a basement membrane to support the epidermal epithelium. Immunofluorescence microscopy and spatially resolved transcriptomics analysis demonstrated the secretion of key ECM components and the formation of microvascular-like structures. Furthermore, the epidermal layer exhibited clear stratification and the formation of a cornified layer, resulting in a tight physiologic epithelial barrier. Our findings indicate that the presented FN-silk-based skin models can be proposed as physiologically relevant standalone epidermal or dermal models, as well as a combined BSE.


  • An all thiol–ene microchip for solid phase extraction featuring an in situ polymerized monolith and integrated 3D replica-molded emitter for direct electrospray mass spectrometry

    by Alexander Jönsson, Josiane P. Lafleur, Drago Sticker, Jörg P. Kutter

    Pre-concentration and clean-up are essential sample preparation steps in environmental, forensics and bio-analytical assays. Here, we present work towards a fully integrated, replica molded all thiol–ene lab-on-a-chip solution for sample enrichment and mass spectrometry. A microfluidic chip based column, for solid phase extraction (SPE), was fabricated using thiol–ene as both bulk material and an in situ polymerized monolith. C11-alkyl chains, in the form of undecanethiol, could be directly immobilized at the monolith surface, through the thiol–ene click reaction. Capacity of the produced SPE columns, for the test compound anthracene, was investigated by UV/Vis absorbance by connecting the chips to the detector of a commercial CE instrument with the help of a 3D-printed chip holder. The column capacity for anthracene was found to be ca. 14 μg m−2, which is consistent with the surface density of functional groups present at the monolith surface. The SPE column was further integrated with a unique on-chip electrospray ionization (ESI) emitter and hyphenated to an ion trap mass spectrometer. The emitter is directly replica molded in the process of chip fabrication, without any additional post-processing, and features a three-dimensional taper. The produced electrospray was investigated in the range of 250–370 m/z and found to be stable with a relative standard deviation of 8 ± 3%. Using the endogenous steroid progesterone, on-line extraction was also investigated on the SPE-ESI chip by direct infusion. Recoveries ranging from 40–50% indicated that further work is required to improve performance. However, the potential of an all-polymer, inexpensive device for sample clean-up featuring an integrated ESI emitter opens up an array of possibilities for applications in fields where single-use devices are mandatory, such as medical, biological, and pharmaceutical applications.


  • Fabrication of Biomolecule Microarrays Using Rapid Photochemical Surface Patterning in Thiol–Ene-Based Microfluidic Devices

    by Alexander Jönsson, Josiane P. Lafleur

    In many biochip applications, it is advantageous to be able to immobilize biomolecules at specific locations on the surface of solid supports. In this protocol, we describe a photochemical surface patterning procedure based on thiol–ene/yne photochemistry which allows for the simple and rapid selective patterning of biomolecules on thiol–ene solid supports. We describe the preparation of solid supports which are required for the immobilization, including porous monoliths, as well as two different immobilization schemes based on biotin–streptavidin interactions and covalent linkage via free amino groups respectively.


  • Open Access

    Thiol-ene Monolithic Pepsin Microreactor with a 3D-Printed Interface for Efficient UPLC-MS Peptide Mapping Analyses

    by Alexander Jönsson, Rasmus R. Svejdal, Nanna Bøgelund, Tam T. T. N. Nguyen, Henrik Flindt, Jörg P. Kutter, Kasper D. Rand, Josiane P. Lafleur

    To improve the sample handling, and reduce cost and preparation time, of peptide mapping LC-MS workflows in protein analytical research, we here investigate the possibility of replacing conventional enzymatic digestion methods with a polymer microfluidic chip based enzyme reactor. Off-stoichiometric thiol-ene is utilized as both bulk material and as a monolithic stationary phase for immobilization of the proteolytic enzyme pepsin. The digestion efficiency of the, thiol-ene based, immobilized enzyme reactor (IMER) is compared to that of a conventional, agarose packed bed, pepsin IMER column commonly used in LC-MS based protein analyses. The chip IMER is found to rival the conventional column in terms of digestion efficiency at comparable residence time and, using a 3D-printed interface, be directly interfaceable with LC-MS.


  • Recent advances in lab-on-a-chip for biosensing applications

    by Josiane P. Lafleur, Alexander Jönsson, Silja Senkbeil, Jörg P. Kutter