Pengfei Cui
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Pengfei Cui has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
Jiarui Lin
State Key Laboratory of Precision Measurement Technology and Instruments, Tianjin University, Tianjin 300072, China
1 shared publicationJigui Zhu
State Key Laboratory of Precision Measurement Technology and Instruments, Tianjin University, Tianjin 300072, China
1 shared publicationLinghui Yang
State Key Laboratory of Precision Measurement Technology and Instruments, Tianjin University, Tianjin 300072, China
1 shared publicationMeina Song
School of Physics and Information Technology, Shaanxi Normal University, Xi'an 710062, People's Republic of China
1 shared publication- Qian He
School of Physics and Information Technology, Shaanxi Normal University, Xi'an 710062, People's Republic of China
1 shared publication - Qiqiang Niu
School of Physics and Information Technology, Shaanxi Normal University, Xi'an 710062, People's Republic of China
1 shared publication
Latest Publications
- 10 May 2021
- Published by IOP Publishing in Physica Scripta
- Vol. 96 (7) , 075505
Multiple plasmon-induced transparency with extra-high FOM based on a MIM waveguide composed of stubs
A plasmon structure based on a metal-insulator-metal (MIM) waveguide composed of three stubs (TSs) is proposed, and its transmission characteristics are studied numerically by the finite element method (FEM). The simulation results show that multiple plasmon-induced transparencies (PITs) with high transmission can be produced in the structure and can be tuned effectively. By adjusting the structure parameters, more high-order PITs with narrower window are generated. Furthermore, the proposed MIM waveguide is sensitive to the environment and the maximum values of refractive index sensitivity and figure of merit (FOM) are 1340 nm R −1 IU −1 and 251/RIU, respectively. Multiple, adjustable and narrow PITs with high FOM can be induced in the proposed structure, which can be used in the fields of multi-channel filters, optical switches, storages, sensors, and so on.
- 10 May 2021
- Published by IOP Publishing in Physica Scripta
- Vol. 96 (7) , 075505
Multiple plasmon-induced transparency with extra-high FOM based on a MIM waveguide composed of stubs
A plasmon structure based on a metal-insulator-metal (MIM) waveguide composed of three stubs (TSs) is proposed, and its transmission characteristics are studied numerically by the finite element method (FEM). The simulation results show that multiple plasmon-induced transparencies (PITs) with high transmission can be produced in the structure and can be tuned effectively. By adjusting the structure parameters, more high-order PITs with narrower window are generated. Furthermore, the proposed MIM waveguide is sensitive to the environment and the maximum values of refractive index sensitivity and figure of merit (FOM) are 1340 nm R −1 IU −1 and 251/RIU, respectively. Multiple, adjustable and narrow PITs with high FOM can be induced in the proposed structure, which can be used in the fields of multi-channel filters, optical switches, storages, sensors, and so on.
- Open Access
- 8 May 2015
- Published by Optica Publishing Group in Optics Express
- Vol. 23 (10) , 13069-13081
Pulse-to-pulse alignment based on interference fringes and the second-order temporal coherence function of optical frequency combs for distance measurement
A pulse-to-pulse alignment method based on interference fringes and the second-order temporal coherence function of optical frequency combs is proposed for absolute distance measurement. The second-order temporal coherence function of the pulse train emitted from optical frequency combs is studied. A numerical model of the function is developed with an assumption of Gaussian pulse and has good agreement with experimental measurements taken by an ordinary Michelson interferometer. The experimental results show an improvement of standard deviation of peak finding results from 27.3 nm to 8.5 nm by the method in ordinary laboratory conditions. The absolute distance measurement with the pulse-to-pulse alignment method is also proposed and experimentally proved.
- 8 May 2015
- Published by Optica Publishing Group in Optics Express
- Vol. 23 (10) , 13069-13081
Open AccessPulse-to-pulse alignment based on interference fringes and the second-order temporal coherence function of optical frequency combs for distance measurement
A pulse-to-pulse alignment method based on interference fringes and the second-order temporal coherence function of optical frequency combs is proposed for absolute distance measurement. The second-order temporal coherence function of the pulse train emitted from optical frequency combs is studied. A numerical model of the function is developed with an assumption of Gaussian pulse and has good agreement with experimental measurements taken by an ordinary Michelson interferometer. The experimental results show an improvement of standard deviation of peak finding results from 27.3 nm to 8.5 nm by the method in ordinary laboratory conditions. The absolute distance measurement with the pulse-to-pulse alignment method is also proposed and experimentally proved.