Bablesh Kumar Jha
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Bablesh Kumar Jha has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
Devender Singh
Electrical Engineering Department IIT(BHU) Varanasi Uttar Pradesh India
8 shared publications- Abhishek Kumar
Department of Artificial Intelligence Kyungpook National University Daegu South Korea
7 shared publications Rakesh Kumar Misra
Electrical Engineering Department IIT(BHU) Varanasi Uttar Pradesh India
6 shared publicationsDharmendra Kumar Dheer
Electrical Engineering Department NIT Patna Bihar India
2 shared publicationsRakesh K. Misra
Department of Electrical Engineering IIT (BHU) Varanasi India
2 shared publicationsAmit Singh
Electrical Engineering Department IIT(BHU) Varanasi Uttar Pradesh India
1 shared publication
Latest Publications
- Open Access
- 1 June 2020
- Published by Institution of Engineering and Technology (IET) in IET Electrical Systems in Transportation
- Vol. 10 (2) , 170-184
Day ahead scheduling of PHEVs and D‐BESSs in the presence of DGs in the distribution system
The rapid growth of plug‐in hybrid electric vehicles (PHEVs)/electric vehicles (EVs) and their capability of providing a vehicle to grid power support in distribution network needs in‐depth studies for the effective operation of the distribution system. Charging/discharging of EV from/to the distribution system has significant impacts on the load demand, network congestion, voltage rise/dip, and other operational issues. Power supply from distributed generators (DGs) is utilised during the peak demand hour to avoid the need for upgradation of the distribution systems. In this study, 24‐hour day ahead power scheduling of PHEVs (in between arrival and departure time), distributed‐battery energy storage system (D‐BESS) and DGs is proposed to mitigate its effect on the distribution system. Four objective functions including system operating cost, CO 2 emission, energy losses, and load flattening are considered to examine the effect of distributed sources on the 38‐bus distribution system. An effective butterfly optimiser is implemented to minimise single weighted objective function. To understand individual as well as combined effect of unscheduled PHEVs charging, scheduled charging/discharging of PHEVs, D‐BESS, and DGs various case studies is performed. On the basis of these case studies, optimal scheduling of PHEVs, D‐BESS, and DGs are proposed to improve the overall system performance.
- 1 June 2020
- Published by Institution of Engineering and Technology (IET) in IET Electrical Systems in Transportation
- Vol. 10 (2) , 170-184
Open AccessDay ahead scheduling of PHEVs and D‐BESSs in the presence of DGs in the distribution system
The rapid growth of plug‐in hybrid electric vehicles (PHEVs)/electric vehicles (EVs) and their capability of providing a vehicle to grid power support in distribution network needs in‐depth studies for the effective operation of the distribution system. Charging/discharging of EV from/to the distribution system has significant impacts on the load demand, network congestion, voltage rise/dip, and other operational issues. Power supply from distributed generators (DGs) is utilised during the peak demand hour to avoid the need for upgradation of the distribution systems. In this study, 24‐hour day ahead power scheduling of PHEVs (in between arrival and departure time), distributed‐battery energy storage system (D‐BESS) and DGs is proposed to mitigate its effect on the distribution system. Four objective functions including system operating cost, CO 2 emission, energy losses, and load flattening are considered to examine the effect of distributed sources on the 38‐bus distribution system. An effective butterfly optimiser is implemented to minimise single weighted objective function. To understand individual as well as combined effect of unscheduled PHEVs charging, scheduled charging/discharging of PHEVs, D‐BESS, and DGs various case studies is performed. On the basis of these case studies, optimal scheduling of PHEVs, D‐BESS, and DGs are proposed to improve the overall system performance.
- 1 March 2020
- Published by Elsevier in Electric Power Systems Research
- Vol. 180
A Nested-Iterative Newton-Raphson based Power Flow Formulation for Droop-based Islanded Microgrids
- 1 March 2020
- Published by Elsevier in Electric Power Systems Research
- Vol. 180
A Nested-Iterative Newton-Raphson based Power Flow Formulation for Droop-based Islanded Microgrids
- 7 February 2020
- Published by Taylor & Francis in Electric Power Components and Systems
- Vol. 48 (3) , 268-280
A New Current Injection Based Power Flow Formulation
This paper presents a novel current injection-based Newton-Raphson power flow algorithm with new PV bus representation for improving the convergence characteristics. In this proposed algorithm, rectangular coordinates are used to represent all non-linear current injection equations. Test results are produced to discuss the reasons behind the non-convergence of different PV bus representation schemes, also their performance comparison was done on the unbalanced 3-phase radial (18-Bus, 28-Bus, 84- Bus and 140-Bus) and meshed (6-Bus, 14-Bus, 24-Bus, 30-Bus, 57-Bus, 118-Bus and 300-bus, and 1354-Bus) test systems. Experimental results show that the proposed power flow method provides better convergence property for distribution system with a large number of PV buses. Also, the modification leads to a smaller Jacobian matrix and therefore reduces computational time.- 7 February 2020
- Published by Taylor & Francis in Electric Power Components and Systems
- Vol. 48 (3) , 268-280
A New Current Injection Based Power Flow Formulation
This paper presents a novel current injection-based Newton-Raphson power flow algorithm with new PV bus representation for improving the convergence characteristics. In this proposed algorithm, rectangular coordinates are used to represent all non-linear current injection equations. Test results are produced to discuss the reasons behind the non-convergence of different PV bus representation schemes, also their performance comparison was done on the unbalanced 3-phase radial (18-Bus, 28-Bus, 84- Bus and 140-Bus) and meshed (6-Bus, 14-Bus, 24-Bus, 30-Bus, 57-Bus, 118-Bus and 300-bus, and 1354-Bus) test systems. Experimental results show that the proposed power flow method provides better convergence property for distribution system with a large number of PV buses. Also, the modification leads to a smaller Jacobian matrix and therefore reduces computational time.- 17 December 2019
- Published by Wiley in International Transactions on Electrical Energy Systems
- Vol. 30 (4)
A modified current injection load flow method under different load model of EV for distribution system
- 17 December 2019
- Published by Wiley in International Transactions on Electrical Energy Systems
- Vol. 30 (4)
A modified current injection load flow method under different load model of EV for distribution system
- Open Access
- 7 November 2019
- Published by Institution of Engineering and Technology (IET) in IET Generation, Transmission & Distribution
- Vol. 13 (23) , 5271-5283
Current injection‐based Newton–Raphson power‐flow algorithm for droop‐based islanded microgrids
The power‐flow analysis of droop‐based islanded microgrid (DBIMG) is a growing research area. The conventional power‐flow techniques have been difficult to employ in DBIMG due to the non‐existence of reference bus (slack bus). To address this issue, a current injection Newton–Raphson based novel algorithm is proposed. The proposed algorithm chooses system frequency and voltage magnitude of the reference bus as additional variables in power‐flow formulation. The proposed algorithm takes into account three operating modes of distributed generators viz. Droop control, PQ and PV . The linear equations cover the droop characteristics of the DGs, while non‐linear equations cover power‐flow equations of the system. The proposed algorithm has been executed on two test systems viz. 6‐bus system and 38‐bus system. To show the effectiveness and robustness of the proposed algorithm, the performance of the proposed algorithm is also examined for the different loading conditions and different R/X ratios of the line of the test systems. The obtained solutions have also been compared with the solutions obtained by other Newton–Raphson based algorithms reported in the literature and PSCAD. The comparative analysis shows better efficiency and superior convergence of the proposed algorithm.
- 7 November 2019
- Published by Institution of Engineering and Technology (IET) in IET Generation, Transmission & Distribution
- Vol. 13 (23) , 5271-5283
Open AccessCurrent injection‐based Newton–Raphson power‐flow algorithm for droop‐based islanded microgrids
The power‐flow analysis of droop‐based islanded microgrid (DBIMG) is a growing research area. The conventional power‐flow techniques have been difficult to employ in DBIMG due to the non‐existence of reference bus (slack bus). To address this issue, a current injection Newton–Raphson based novel algorithm is proposed. The proposed algorithm chooses system frequency and voltage magnitude of the reference bus as additional variables in power‐flow formulation. The proposed algorithm takes into account three operating modes of distributed generators viz. Droop control, PQ and PV . The linear equations cover the droop characteristics of the DGs, while non‐linear equations cover power‐flow equations of the system. The proposed algorithm has been executed on two test systems viz. 6‐bus system and 38‐bus system. To show the effectiveness and robustness of the proposed algorithm, the performance of the proposed algorithm is also examined for the different loading conditions and different R/X ratios of the line of the test systems. The obtained solutions have also been compared with the solutions obtained by other Newton–Raphson based algorithms reported in the literature and PSCAD. The comparative analysis shows better efficiency and superior convergence of the proposed algorithm.
- Open Access
- 21 October 2019
- Published by Institution of Engineering and Technology (IET) in IET Generation, Transmission & Distribution
- Vol. 13 (22) , 5019-5032
Optimal scheduling of PHEVs and D‐BESSs in the presence of DGs in a distribution system
Optimisation of cost and load flattening for a distribution network is attempted in this work. The objective function is described in terms of energy cost, emissions, real power losses, and load flattening. The solution is envisaged in terms of hourly scheduling of distributed generations (DGs), distributed battery energy storage systems (D‐BESSs), and plug‐in hybrid electric vehicles (PHEVs). An investigation in the reformulation of the cost of energy is carried out to eliminate the solutions involving excessive charging and discharging of BESSs/D‐BESSs and PHEVs. It is demonstrated that simultaneous optimisation of cost, emissions, real power losses, and load flattening cannot be effectively solved as a weighted sum objective function. An ‐constraint method is applied to obtain the optimal scheduling to achieve cost optimisation, load flattening, and minimisation of emissions from the utility point of view. A case of decentralised multi‐agent optimisation problem is also formulated and compared. It is observed that the combination of the scheduling of DGs, BESSs/D‐BESSs, grid‐to‐vehicle/vehicle‐to‐grid can successfully be used to significantly reduce the system peak demand along with system cost, losses and emissions.
- 21 October 2019
- Published by Institution of Engineering and Technology (IET) in IET Generation, Transmission & Distribution
- Vol. 13 (22) , 5019-5032
Open AccessOptimal scheduling of PHEVs and D‐BESSs in the presence of DGs in a distribution system
Optimisation of cost and load flattening for a distribution network is attempted in this work. The objective function is described in terms of energy cost, emissions, real power losses, and load flattening. The solution is envisaged in terms of hourly scheduling of distributed generations (DGs), distributed battery energy storage systems (D‐BESSs), and plug‐in hybrid electric vehicles (PHEVs). An investigation in the reformulation of the cost of energy is carried out to eliminate the solutions involving excessive charging and discharging of BESSs/D‐BESSs and PHEVs. It is demonstrated that simultaneous optimisation of cost, emissions, real power losses, and load flattening cannot be effectively solved as a weighted sum objective function. An ‐constraint method is applied to obtain the optimal scheduling to achieve cost optimisation, load flattening, and minimisation of emissions from the utility point of view. A case of decentralised multi‐agent optimisation problem is also formulated and compared. It is observed that the combination of the scheduling of DGs, BESSs/D‐BESSs, grid‐to‐vehicle/vehicle‐to‐grid can successfully be used to significantly reduce the system peak demand along with system cost, losses and emissions.
- Open Access
- 27 June 2019
- Published by Institution of Engineering and Technology (IET) in IET Generation, Transmission & Distribution
- Vol. 13 (14) , 3086-3095
Nested backward/forward sweep algorithm for power flow analysis of droop regulated islanded microgrids
In this study, nested backward/forward sweep (NBFS) algorithm, is proposed to solve the load flow problem of islanded microgrids. The proposed algorithm is designed in such a way that the voltage magnitude of the angle reference bus and the system frequency become additional variables in the power flow analysis. In the absence of the slack bus, new loops and equations are introduced in the proposed backward/forward sweep (BFS) method to fulfil the requirement of droop characteristics in the power flow analysis. In each loop of the proposed algorithm, modified equations of BFS are employed to update the voltages of every bus except angle reference bus (slack bus). The voltage of angle reference bus and the system frequency are updated at the end of each loop operation. The proposed NBFS method is applied on several test systems including IEEE 22‐bus, 38‐bus, 69‐bus, and 160‐bus and the obtained results are compared with the result obtained from other BFS‐based algorithms including direct BFS and modified BFS, Jacobian‐based algorithms including Newton trust region (NTR) algorithm and modified Newton ‐Raphson (MNR) algorithm, and time‐domain simulation in PSCAD/EMTDC. The proposed algorithm for droop‐regulated AC microgrid exhibits faster convergence with better accuracy as compare to other algorithms.
- 27 June 2019
- Published by Institution of Engineering and Technology (IET) in IET Generation, Transmission & Distribution
- Vol. 13 (14) , 3086-3095
Open AccessNested backward/forward sweep algorithm for power flow analysis of droop regulated islanded microgrids
In this study, nested backward/forward sweep (NBFS) algorithm, is proposed to solve the load flow problem of islanded microgrids. The proposed algorithm is designed in such a way that the voltage magnitude of the angle reference bus and the system frequency become additional variables in the power flow analysis. In the absence of the slack bus, new loops and equations are introduced in the proposed backward/forward sweep (BFS) method to fulfil the requirement of droop characteristics in the power flow analysis. In each loop of the proposed algorithm, modified equations of BFS are employed to update the voltages of every bus except angle reference bus (slack bus). The voltage of angle reference bus and the system frequency are updated at the end of each loop operation. The proposed NBFS method is applied on several test systems including IEEE 22‐bus, 38‐bus, 69‐bus, and 160‐bus and the obtained results are compared with the result obtained from other BFS‐based algorithms including direct BFS and modified BFS, Jacobian‐based algorithms including Newton trust region (NTR) algorithm and modified Newton ‐Raphson (MNR) algorithm, and time‐domain simulation in PSCAD/EMTDC. The proposed algorithm for droop‐regulated AC microgrid exhibits faster convergence with better accuracy as compare to other algorithms.
- 26 December 2018
- Published by Wiley in International Transactions on Electrical Energy Systems
- Vol. 29 (4) , e2800
Coordinated effect of PHEVs with DGs on distribution network
- 26 December 2018
- Published by Wiley in International Transactions on Electrical Energy Systems
- Vol. 29 (4) , e2800
Coordinated effect of PHEVs with DGs on distribution network
- 1 January 2014
- Published by Science Publishing Group in American Journal of Electrical Power and Energy Systems
- Vol. 3 (1) , 7-14
Combined Operation of SVC, PSS and Increasing Inertia of Machine for Power System Transient Stability Enhancement
In this paper improvement of transient stability by coordination of PSS (Power System Stabilizer) and SVC (Static var Compensator) and increasing inertia of synchronous machine has been observed. Because single method is not sufficient for improving stability. For this purpose a 9 bus multi machine system has been considered. Transient stability improvement has been tested subjected to three phase fault at bus 3 after 0.5 second and fault has been cleared after 1 second. By the use of PSS, SVC and by increasing inertia method for the test system the electromechanical oscillation for generator electrical power has been reduced and the steady state power transfer has been enhanced. In this paper the Inertia of the machine is not so much increased. Because after increasing inertia of the machine rotor will be havier.so that it is kept always within limit as considering its reliability and economy. And field voltage is also kept limited.
- 1 January 2014
- Published by Science Publishing Group in American Journal of Electrical Power and Energy Systems
- Vol. 3 (1) , 7-14
Combined Operation of SVC, PSS and Increasing Inertia of Machine for Power System Transient Stability Enhancement
In this paper improvement of transient stability by coordination of PSS (Power System Stabilizer) and SVC (Static var Compensator) and increasing inertia of synchronous machine has been observed. Because single method is not sufficient for improving stability. For this purpose a 9 bus multi machine system has been considered. Transient stability improvement has been tested subjected to three phase fault at bus 3 after 0.5 second and fault has been cleared after 1 second. By the use of PSS, SVC and by increasing inertia method for the test system the electromechanical oscillation for generator electrical power has been reduced and the steady state power transfer has been enhanced. In this paper the Inertia of the machine is not so much increased. Because after increasing inertia of the machine rotor will be havier.so that it is kept always within limit as considering its reliability and economy. And field voltage is also kept limited.