Takeshi Yokoyama
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Takeshi Yokoyama has a total of 76 co-authors. Here are the top co-authors by number of shared publications:
- Masanori Tsukamoto
Department of Dental Anesthesiology, Kyushu University Hospital, Fukuoka, Japan
15 shared publications - Koichi Yamashita
Department of Anesthesiology and Intensive Care Medicine, Kochi Medical School
14 shared publications Masanobu Manabe
10 shared publications- Takashi Hitosugi
Kyushu University
8 shared publications - Tomoaki Yatabe
Department of Anesthesiology and Intensive Care Medicine, Nishichita General Hospital, Tokai, Japan
5 shared publications Tomoki Nishiyama
5 shared publications
Latest Publications
- Open Access
Preliminary Quantitative Evaluation of the Optimal Colour System for the Assessment of Peripheral Circulation from Applied Pressure Using Machine Learning
Peripheral circulatory failure refers to a condition in which the blood flow through superficial capillaries is markedly reduced or completely occluded. In clinical practice, nurses strictly adhere to regular repositioning protocols to prevent peripheral circulatory failure, during which the skin condition is evaluated visually. In this study, skin colour changes resulting from pressure application were continuously captured using a camera, and supervised machine learning was employed to classify the data into two categories: before and after pressure. The evaluation of practical colour space components revealed that the h component of the JCh colour space demonstrated the highest discriminative performance (Area Under the Curve (AUC) = 0.88), followed by the a* component of the CIELAB colour space (AUC = 0.84) and the H component of the HSV colour space (AUC = 0.83). These findings demonstrate that it is feasible to quantitatively evaluate skin colour changes associated with pressure, suggesting that this approach can serve as a valuable indicator for dimensionality reduction in feature extraction for machine learning and is potentially an effective method for preventing pressure-induced skin injuries.
Open AccessPreliminary Quantitative Evaluation of the Optimal Colour System for the Assessment of Peripheral Circulation from Applied Pressure Using Machine Learning
Peripheral circulatory failure refers to a condition in which the blood flow through superficial capillaries is markedly reduced or completely occluded. In clinical practice, nurses strictly adhere to regular repositioning protocols to prevent peripheral circulatory failure, during which the skin condition is evaluated visually. In this study, skin colour changes resulting from pressure application were continuously captured using a camera, and supervised machine learning was employed to classify the data into two categories: before and after pressure. The evaluation of practical colour space components revealed that the h component of the JCh colour space demonstrated the highest discriminative performance (Area Under the Curve (AUC) = 0.88), followed by the a* component of the CIELAB colour space (AUC = 0.84) and the H component of the HSV colour space (AUC = 0.83). These findings demonstrate that it is feasible to quantitatively evaluate skin colour changes associated with pressure, suggesting that this approach can serve as a valuable indicator for dimensionality reduction in feature extraction for machine learning and is potentially an effective method for preventing pressure-induced skin injuries.
- Open Access
Reliable Stenosis Detection Based on Thrill Waveform Analysis Using Non-Contact Arteriovenous Fistula Imaging
Hemodialysis therapy is an extracorporeal circulation treatment that serves as a substitute for renal function. In Japan, patients receive this efficient four-hour treatment, three times per week, allowing them to maintain a social life nearly equivalent to that of healthy individuals. Before the treatment, two punctures are performed to establish extracorporeal circulation, and a high blood flow rate is essential to ensure efficient therapy. Specialized blood vessels created through arteriovenous fistula (AVF) surgery are utilized to achieve high blood flow rates. Although the AVF allows safe and efficient dialysis treatment, AVF stenosis leads to a serious problem in dialysis. To early detect this abnormal blood flow, auscultation and palpation methods are widely used in hospitals. However, these methods can only provide qualitative judgment of the AVF condition, so the results cannot be shared among other doctors and staff. Additionally, since the conventional methods require contact with the skin, some issues require consideration regarding infection and low reproducibility. In our previous study, we proposed an alternative method for auscultation using non-contact optical imaging technology. This study aims to construct a reliable AVF stenosis detection method using Thrill waveform analysis based on the developed non-contact device to solve the problem with the contact palpation method. This paper demonstrates the performance validation of the non-contact imaging in the normal AVF group (206 total data, 75 patients, mean age: 69.1 years) and in the treatable stenosis group (107 total data, 17 patients, mean age: 70.1 years). The experimental results of the Mann–Whitney U test showed a significant difference () between the normal and abnormal groups, which indicated the effectiveness of the proposed method as a new possible alternative to palpation.Open AccessReliable Stenosis Detection Based on Thrill Waveform Analysis Using Non-Contact Arteriovenous Fistula Imaging
Hemodialysis therapy is an extracorporeal circulation treatment that serves as a substitute for renal function. In Japan, patients receive this efficient four-hour treatment, three times per week, allowing them to maintain a social life nearly equivalent to that of healthy individuals. Before the treatment, two punctures are performed to establish extracorporeal circulation, and a high blood flow rate is essential to ensure efficient therapy. Specialized blood vessels created through arteriovenous fistula (AVF) surgery are utilized to achieve high blood flow rates. Although the AVF allows safe and efficient dialysis treatment, AVF stenosis leads to a serious problem in dialysis. To early detect this abnormal blood flow, auscultation and palpation methods are widely used in hospitals. However, these methods can only provide qualitative judgment of the AVF condition, so the results cannot be shared among other doctors and staff. Additionally, since the conventional methods require contact with the skin, some issues require consideration regarding infection and low reproducibility. In our previous study, we proposed an alternative method for auscultation using non-contact optical imaging technology. This study aims to construct a reliable AVF stenosis detection method using Thrill waveform analysis based on the developed non-contact device to solve the problem with the contact palpation method. This paper demonstrates the performance validation of the non-contact imaging in the normal AVF group (206 total data, 75 patients, mean age: 69.1 years) and in the treatable stenosis group (107 total data, 17 patients, mean age: 70.1 years). The experimental results of the Mann–Whitney U test showed a significant difference () between the normal and abnormal groups, which indicated the effectiveness of the proposed method as a new possible alternative to palpation. - 10 May 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
A Study on Stenosis Detection Based on Non-contact Thrill Wave Imaging and Gradient-Boosting Decision Tree
Hemodialysis therapy generally requires a special blood vessel called an arteriovenous fistula (AVF), which is surgically anastomosed between an artery and a vein. Since an AVF often becomes stenosis, palpation is used to palpate the vessel wall vibrations, which is called thrill wave, before and after hemodialysis treatment. This method is widely used, especially in Japan, because of its simplicity. However, several problems in the palpation has been pointed out in terms of reliability because the palpation requires contact diagnosis. In order to solve the problems in the conventional contact palpation, we developed a thrill wave measurement device using non-contact imaging based on an optical technology. Then, we introduced a gradient-boosting decision tree algorithm to detect stenosis in AVFs. The experimental results showed that true positive rate (TPR) = 92.3%, true negative rate (TNR) = 76.7%, false positive rate (FPR) = 7.7% and false negative rate (FNR) = 23.3% to identify normal and stenotic AVFs.
- 10 May 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
A Study on Stenosis Detection Based on Non-contact Thrill Wave Imaging and Gradient-Boosting Decision Tree
Hemodialysis therapy generally requires a special blood vessel called an arteriovenous fistula (AVF), which is surgically anastomosed between an artery and a vein. Since an AVF often becomes stenosis, palpation is used to palpate the vessel wall vibrations, which is called thrill wave, before and after hemodialysis treatment. This method is widely used, especially in Japan, because of its simplicity. However, several problems in the palpation has been pointed out in terms of reliability because the palpation requires contact diagnosis. In order to solve the problems in the conventional contact palpation, we developed a thrill wave measurement device using non-contact imaging based on an optical technology. Then, we introduced a gradient-boosting decision tree algorithm to detect stenosis in AVFs. The experimental results showed that true positive rate (TPR) = 92.3%, true negative rate (TNR) = 76.7%, false positive rate (FPR) = 7.7% and false negative rate (FNR) = 23.3% to identify normal and stenotic AVFs.
- Open Access
- 16 May 2022
- Published by Springer Nature in BMC Anesthesiology
- Vol. 22  (1) , 1-5
Sevoflurane concentration for cannulation in developmental disabilities
Objective: The goal of this study was to compare the end-tidal sevoflurane concentration and time for intravenous cannulation at induction of anesthesia using sevoflurane with or without nitrous oxide in healthy children and in those with developmental disabilities.Methods: Normal and developmentally disabled children were anesthetized by inhalation of sevoflurane with nitrous oxide or with nitrous oxide-free oxygen, and intravenous cannulae were introduced. Nitrous oxide was stopped after loss of consciousness. The following parameters were recorded for each patient: age, gender, height, weight, BMI, duration of intravenous cannulation, end-tidal concentration of sevoflurane at the completion of intravenous cannulation, and use of nitrous oxide.For each parameter except gender,p-value were calculated by one-way analysis of variance (ANOVA). For gender,p-value were calculated using the Fisher method. Two-way ANOVA was performed to evaluate the effect of patient health status and nitrous oxide use on the end-tidal concentrations of sevoflurane and the time required for intravenous cannulation.Results: The end-tidal sevoflurane concentrations at the completion of the intravenous cannulation had received a significant main effect of the factor "the use of nitrous oxide" (F(1,166) = 25.8,p < 0.001, η2 = 0.13) and a small effect of the factor "the patient health status" (F(1,166) = 0.259,p = 0.611, η2 = 0.001). However, the time required for intravenous cannulation was not significantly affected by either of the two factors, "the use of nitrous oxide" (F(1,166) = 0.454,p = 0.501, η2 = 0.003) and "the patient health status" (F(1,166) = 0.308,p = 0.579, η2 = 0.002).Conclusions: Between the healthy children and the children with developmental disabilities, no significant differences in the time required for the intravenous cannulation from the beginning of anesthetic induction. However, the end-tidal sevoflurane concentrations at the completion of the intravenous cannulation was significantly different. Sevoflurane in alveoli might be diluted by nitrous oxide.
- 16 May 2022
- Published by Springer Nature in BMC Anesthesiology
- Vol. 22  (1) , 1-5
Open AccessSevoflurane concentration for cannulation in developmental disabilities
Objective: The goal of this study was to compare the end-tidal sevoflurane concentration and time for intravenous cannulation at induction of anesthesia using sevoflurane with or without nitrous oxide in healthy children and in those with developmental disabilities.Methods: Normal and developmentally disabled children were anesthetized by inhalation of sevoflurane with nitrous oxide or with nitrous oxide-free oxygen, and intravenous cannulae were introduced. Nitrous oxide was stopped after loss of consciousness. The following parameters were recorded for each patient: age, gender, height, weight, BMI, duration of intravenous cannulation, end-tidal concentration of sevoflurane at the completion of intravenous cannulation, and use of nitrous oxide.For each parameter except gender,p-value were calculated by one-way analysis of variance (ANOVA). For gender,p-value were calculated using the Fisher method. Two-way ANOVA was performed to evaluate the effect of patient health status and nitrous oxide use on the end-tidal concentrations of sevoflurane and the time required for intravenous cannulation.Results: The end-tidal sevoflurane concentrations at the completion of the intravenous cannulation had received a significant main effect of the factor "the use of nitrous oxide" (F(1,166) = 25.8,p < 0.001, η2 = 0.13) and a small effect of the factor "the patient health status" (F(1,166) = 0.259,p = 0.611, η2 = 0.001). However, the time required for intravenous cannulation was not significantly affected by either of the two factors, "the use of nitrous oxide" (F(1,166) = 0.454,p = 0.501, η2 = 0.003) and "the patient health status" (F(1,166) = 0.308,p = 0.579, η2 = 0.002).Conclusions: Between the healthy children and the children with developmental disabilities, no significant differences in the time required for the intravenous cannulation from the beginning of anesthetic induction. However, the end-tidal sevoflurane concentrations at the completion of the intravenous cannulation was significantly different. Sevoflurane in alveoli might be diluted by nitrous oxide.
- Open Access
Quantification and Visualization of Reliable Hemodynamics Evaluation Based on Non-Contact Arteriovenous Fistula Measurement
The condition of arteriovenous fistula (AVF) blood flow is typically checked by using auscultation; however, auscultation should require a qualitative judgment dependent on the skills of doctors, and further attention to contact infection is required. For these reasons, this study developed a non-contact and non-invasive medical device to measure the pulse wave of AVFs by applying optical imaging technology. As a first step toward realization of the quantification judgment based on non-contact AVF measurement, we experimentally validated the developed system, whereby the hemodynamics of 168 subjects were visually and quantitatively evaluated based on clinical tests. Based on the evaluation results, the fundamental statistical characteristics of the non-contact measurement, including the average and median values, and distribution of measured signal-to-noise power ratio, were demonstrated. The clinical test results contributed to the future construction of quantified criteria for the AVF condition with the non-contact measurement.
Open AccessQuantification and Visualization of Reliable Hemodynamics Evaluation Based on Non-Contact Arteriovenous Fistula Measurement
The condition of arteriovenous fistula (AVF) blood flow is typically checked by using auscultation; however, auscultation should require a qualitative judgment dependent on the skills of doctors, and further attention to contact infection is required. For these reasons, this study developed a non-contact and non-invasive medical device to measure the pulse wave of AVFs by applying optical imaging technology. As a first step toward realization of the quantification judgment based on non-contact AVF measurement, we experimentally validated the developed system, whereby the hemodynamics of 168 subjects were visually and quantitatively evaluated based on clinical tests. Based on the evaluation results, the fundamental statistical characteristics of the non-contact measurement, including the average and median values, and distribution of measured signal-to-noise power ratio, were demonstrated. The clinical test results contributed to the future construction of quantified criteria for the AVF condition with the non-contact measurement.
- Open Access
- 1 December 2020
- Published by Elsevier in JPRAS Open
- Vol. 26, 60-68
Cleft-lip-plate patient with tracheobronchomalacia: A case report and review of the literature in Japan
- 1 December 2020
- Published by Elsevier in JPRAS Open
- Vol. 26, 60-68
Open AccessCleft-lip-plate patient with tracheobronchomalacia: A case report and review of the literature in Japan
- 17 August 2020
- Published by Springer Nature in Clinical Oral Investigations
- Vol. 25  (4) , 2077-2080
Prediction of appropriate formula for nasotracheal tube size in developmental disability children
Objectives Developmental disability children have differences in growth. Therefore, tube size selection is important for nasotracheal intubation. In our previous study for healthy children undergoing dental surgery, height was the most suitable factor to predict nasotracheal tube size. The aim of this study was to find the most suitable formula for selection of nasotracheal tube size for them, retrospectively. Material and methods Developmental disability children aged 2 to 10 years were included in this study. They were intubated nasotracheally from April 2012 until May 2017. Their actually intubated tube sizes were checked. The predicted tube sizes were calculated according to the formulas by the backgrounds: the diameter of the trachea at the 6th cervical (C6), 7th cervical (C7), and 2nd thoracic vertebrae (T2) in X-ray. The actually intubated tube sizes were compared with predicted sizes. Data were analyzed using Spearman’s regression analysis. Results The tube sizes with 5.0, 5.5, and 6.0 mm ID were intubated in 75 patients. The age-based formula was the most suitable; the correlation coefficients (r2) were 0.9027 (vs age), 0.5434 (vs height), 0.3779 (vs weight), 0.0785 (vs C6), 0.2279 (vs C7), and 0.3065 (Th2) (p < 0.01). However, 0.5-mm smaller size tubes were more frequently intubated actually. Their correspondence rate to the predicted size was 48% (5.0 mm), 52% (5.5 mm), and 39% (6.0 mm), respectively. Conclusion The age-based formula could be the most suitable for predicting nasotracheal tube size in developmental disability children aged 2 to 10 years. One smaller size by the age formula was most suitable at first trial tube. Clinical relevance The present data indicate that the selection of nasotracheal tube using one smaller size by the age formula (ID = 4 + age [years]/4) might be useful for developmental disability children.
- 17 August 2020
- Published by Springer Nature in Clinical Oral Investigations
- Vol. 25  (4) , 2077-2080
Prediction of appropriate formula for nasotracheal tube size in developmental disability children
Objectives Developmental disability children have differences in growth. Therefore, tube size selection is important for nasotracheal intubation. In our previous study for healthy children undergoing dental surgery, height was the most suitable factor to predict nasotracheal tube size. The aim of this study was to find the most suitable formula for selection of nasotracheal tube size for them, retrospectively. Material and methods Developmental disability children aged 2 to 10 years were included in this study. They were intubated nasotracheally from April 2012 until May 2017. Their actually intubated tube sizes were checked. The predicted tube sizes were calculated according to the formulas by the backgrounds: the diameter of the trachea at the 6th cervical (C6), 7th cervical (C7), and 2nd thoracic vertebrae (T2) in X-ray. The actually intubated tube sizes were compared with predicted sizes. Data were analyzed using Spearman’s regression analysis. Results The tube sizes with 5.0, 5.5, and 6.0 mm ID were intubated in 75 patients. The age-based formula was the most suitable; the correlation coefficients (r2) were 0.9027 (vs age), 0.5434 (vs height), 0.3779 (vs weight), 0.0785 (vs C6), 0.2279 (vs C7), and 0.3065 (Th2) (p < 0.01). However, 0.5-mm smaller size tubes were more frequently intubated actually. Their correspondence rate to the predicted size was 48% (5.0 mm), 52% (5.5 mm), and 39% (6.0 mm), respectively. Conclusion The age-based formula could be the most suitable for predicting nasotracheal tube size in developmental disability children aged 2 to 10 years. One smaller size by the age formula was most suitable at first trial tube. Clinical relevance The present data indicate that the selection of nasotracheal tube using one smaller size by the age formula (ID = 4 + age [years]/4) might be useful for developmental disability children.
- 1 November 2019
- Published by Springer Nature in Oral and Maxillofacial Surgery
- Vol. 23  (4) , 507-511
Pneumonia due to aspiration of povidine iodine after preoperative disinfection of the oral cavity
Povidone-iodine (PI) is thought to be an effective disinfectant and safe for many surgeons. Aspiration pneumonia is usually caused by gastric contents, but if PI solution will be aspirated, pneumonia or other complications may occur.
- 1 November 2019
- Published by Springer Nature in Oral and Maxillofacial Surgery
- Vol. 23  (4) , 507-511
Pneumonia due to aspiration of povidine iodine after preoperative disinfection of the oral cavity
Povidone-iodine (PI) is thought to be an effective disinfectant and safe for many surgeons. Aspiration pneumonia is usually caused by gastric contents, but if PI solution will be aspirated, pneumonia or other complications may occur.
- 4 July 2019
- Published by Springer Nature in Clinical Oral Investigations
- Vol. 23  (9) , 3653-3656
Comparison of recovery in pediatric patients: a retrospective study
The recovery after general anesthesia is influenced by the choice of inhalational agent. Stimulations might make patient’s agitate. However, the recovery using no touch technique might be safer. In this study, we compared the recovery time, awakening end-tidal concentration, and respiratory complications among inhalational anesthetics in pediatric patients using no touch technique, retrospectively.
- 4 July 2019
- Published by Springer Nature in Clinical Oral Investigations
- Vol. 23  (9) , 3653-3656
Comparison of recovery in pediatric patients: a retrospective study
The recovery after general anesthesia is influenced by the choice of inhalational agent. Stimulations might make patient’s agitate. However, the recovery using no touch technique might be safer. In this study, we compared the recovery time, awakening end-tidal concentration, and respiratory complications among inhalational anesthetics in pediatric patients using no touch technique, retrospectively.
- 1 May 2019
- Published by Elsevier in Journal of Clinical Anesthesia
- Vol. 54, 162-163
ECMO circuit embolism: A potentially hazardous complication during ECMO therapy
- 1 May 2019
- Published by Elsevier in Journal of Clinical Anesthesia
- Vol. 54, 162-163
ECMO circuit embolism: A potentially hazardous complication during ECMO therapy